• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4593696)   Today's Articles (1104)   Subscriber (49324)
For: Moghadas P, Mahomed A, Hukins DW, Shepherd DE. Friction in metal-on-metal total disc arthroplasty: Effect of ball radius. J Biomech 2012;45:504-9. [DOI: 10.1016/j.jbiomech.2011.11.045] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2011] [Revised: 11/21/2011] [Accepted: 11/22/2011] [Indexed: 11/26/2022]
Number Cited by Other Article(s)
1
Mahmood H, Shepherd DE, Espino DM. A technique for measuring the frictional torque of articular cartilage and replacement biomaterials. Med Eng Phys 2020;83:1-6. [DOI: 10.1016/j.medengphy.2020.07.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2019] [Revised: 04/28/2020] [Accepted: 07/02/2020] [Indexed: 10/23/2022]
2
Coric D, Guyer RD, Nunley PD, Musante D, Carmody C, Gordon C, Lauryssen C, Boltes MO, Ohnmeiss DD. Prospective, randomized multicenter study of cervical arthroplasty versus anterior cervical discectomy and fusion: 5-year results with a metal-on-metal artificial disc. J Neurosurg Spine 2018;28:252-261. [DOI: 10.3171/2017.5.spine16824] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
3
Moghadas P, Mahomed A, Shepherd DET, Hukins DWL. Wear of the Charité® lumbar intervertebral disc replacement investigated using an electro-mechanical spine simulator. Proc Inst Mech Eng H 2016;229:264-8. [PMID: 25834002 PMCID: PMC4456431 DOI: 10.1177/0954411915576537] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
4
Five-Year Follow-Up of a Prospective, Randomized Trial Comparing Two Lumbar Total Disc Replacements. Spine (Phila Pa 1976) 2016;41:3-8. [PMID: 26335669 DOI: 10.1097/brs.0000000000001168] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
5
Moghadas P, Mahomed A, Hukins DWL, Shepherd DET. Effect of lubricants on friction in laboratory tests of a total disc replacement device. Proc Inst Mech Eng H 2013;227:988-93. [PMID: 23804950 DOI: 10.1177/0954411913485059] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
6
Moghadas P, Mahomed A, Hukins DWL, Shepherd DET. Wear in metal-on-metal total disc arthroplasty. Proc Inst Mech Eng H 2013;227:356-61. [DOI: 10.1177/0954411912471768] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
7
Bibliography Current World Literature. CURRENT ORTHOPAEDIC PRACTICE 2012. [DOI: 10.1097/bco.0b013e31827525d3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
8
Polymer-on-metal or metal-on-polymer total disc arthroplasty: does it make a difference? Spine (Phila Pa 1976) 2012;37:1834-8. [PMID: 22498992 DOI: 10.1097/brs.0b013e318257fdd3] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
9
Xin H, Shepherd DET, Dearn KD. PEEK (Polyether-ether-ketone) Based Cervical Total Disc Arthroplasty: Contact Stress and Lubrication Analysis. Open Biomed Eng J 2012. [DOI: 10.2174/1874120701206010073] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]  Open
10
Xin H, Shepherd D, Dearn K. PEEK (Polyether-ether-ketone) Based Cervical Total Disc Arthroplasty: Contact Stress and Lubrication Analysis. Open Biomed Eng J 2012;6:73-9. [PMID: 22670159 PMCID: PMC3367298 DOI: 10.2174/1874230001206010073] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2012] [Revised: 03/29/2012] [Accepted: 03/29/2012] [Indexed: 11/22/2022]  Open
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA