1
|
Gilliam JR, Song A, Sahu PK, Silfies SP. Test-retest reliability and construct validity of trunk extensor muscle force modulation accuracy. PLoS One 2023; 18:e0289531. [PMID: 37590280 PMCID: PMC10434934 DOI: 10.1371/journal.pone.0289531] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2023] [Accepted: 07/20/2023] [Indexed: 08/19/2023] Open
Abstract
Low back pain is associated with changes in trunk muscle structure and function and motor control impairments. Voluntary force modulation (FM) of trunk muscles is a unique and under-investigated motor control characteristic. One of the reasons for this paucity of evidence is the lack of exploration and publication on the reliability and validity of trunk FM protocols. The purpose of this study was to determine the within- and between-day test-retest reliability and construct validity for trunk extensor muscle FM. Twenty-nine healthy participants were tested under three FM conditions with different modulation rates. Testing was performed on a custom-built apparatus designed for trunk isometric force testing. FM accuracy relative to a fluctuating target force (20-50%MVF) was quantified using the root mean square error of the participant's generated force relative to the target force. Reliability and precision of measurement were assessed using the Intraclass Correlation Coefficient (ICC), standard error of measurement (SEM), minimal detectable difference (MDD95), and Bland-Altman plots. In a subset of participants, we collected surface electromyography of trunk and hip muscles. We used non-negative matrix factorization (NNMF) to identify the underlying motor control strategies. Within- and between-day test-retest reliability was excellent for FM accuracy across the three conditions (ICC range: 0.865 to 0.979). SEM values ranged 0.9-1.8 Newtons(N) and MDD95 ranged from 2.4-4.9N. Conditions with faster rates of FM had higher ICCs. NNMF analysis revealed two muscle synergies that were consistent across participants and conditions. These synergies demonstrate that the muscles primarily involved in this FM task were indeed the trunk extensor muscles. This protocol can consistently measure FM accuracy within and between testing sessions. Trunk extensor FM, as measured by this protocol, is not specific to any trunk muscle group but is the result of modulation by all the trunk extensor muscles.
Collapse
Affiliation(s)
- John R. Gilliam
- Department of Exercise Science, University of South Carolina, Columbia, South Carolina, United States of America
| | - Ahyoung Song
- Department of Exercise Science, University of South Carolina, Columbia, South Carolina, United States of America
| | - Pradeep K. Sahu
- Department of Exercise Science, University of South Carolina, Columbia, South Carolina, United States of America
| | - Sheri P. Silfies
- Department of Exercise Science, University of South Carolina, Columbia, South Carolina, United States of America
- Physical Therapy Program, University of South Carolina, Columbia, South Carolina, United States of America
| |
Collapse
|
2
|
Luna J, Y Rosas DS, Elias D. A low-cost portable measurement system for a clinical test of balance. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2020:4038-4041. [PMID: 33018885 DOI: 10.1109/embc44109.2020.9175609] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The current work presents the development and technical validation, in terms of accuracy and latency, of a low-cost portable device that allows identifying possible risks of falling in people when they realize spinal trunk lateral movements. The device is comprised of an Inertial Measurement Unit (IMU) located on the lower back. Measurements are processed to get meaningful parameters such as rotation angles of the back when realizing lateral movements. In order to give performance feedback while doing the test, this device includes a Microcontroller as Raspberry Pi to return visual feedback to the person. The critical system feature is the latency of the system since getting the data of a movement until showing that on the feedback screen. For that reason, before to start assessing people, we propose a technical method using the Mikrolar Hexapod Robot R3000 for validating the system developed by simulating the movement of the back and recording it with a video camera to apply an offline Motion-to-Photon Latency analysis.
Collapse
|
3
|
Validation and Application of Two New Core Stability Tests in Professional Football. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10165495] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The purpose of the first study was to validate two newly proposed core stability tests; Prone Plank test (PPT) and Closed Kinetic Chain test (CCT), for evaluating the strength of the body core. Subsequently, these tests were employed in a longitudinal prospective study implementing a core stability training program with a professional Spanish football team. For the validation study, 22 physically active men (Tegner Scale 6–7) performed three trials of the PPT and CCT tests in two different testing sessions separated by one week. In the longitudinal study, 13 male professional football players were equally evaluated (PPT and CCT) before and after the competitive session in which they completed a core training program. Intra-/intersession, and intertester, reliability was analyzed. PPT and CCT demonstrated excellent to good test–retest reliability and acceptable error measurement (ICCs for intratester and intrasession reliability ranged from 0.77 to 0.94 for the PPT, and 0.8–0.9 for the CCT) in all but one of the testing conditions (female tester for CCT test; ICC = 0.38). Significant improvements on core strength were found from pre to post evaluation in both the PPT (p < 0.01) and CCT (p < 0.01) after the implementation of a core training program in professional football players.
Collapse
|
4
|
Abstract
Individuals with back pain are often diagnosed with spine instability, even though it is unclear whether the spine is susceptible to unstable behavior. The spine is a complex system with many elements that cannot be directly observed, which makes the study of spine function and direct assessment of spine instability difficult. What is known is that trunk muscle activation is adjusted to meet stability demands, which highlights that the central nervous system closely monitors threats to spine stability. The spine appears to be protected by neural coupling and mechanical coupling that prevent erroneous motor control from producing segmental instability; however, this neural and mechanical coupling could be problematic in an injured spine. Finally, instability traditionally contemplated from a mechanical and control perspective could potentially be applied to study processes involved in pain sensitization, and possibly back pain that is iatrogenic in nature. This commentary argues for a more contemporary and broadened view of stability that integrates interdisciplinary knowledge in order to capture the complexity of back pain. J Orthop Sports Phys Ther 2019;49(6):415-424. Epub 25 Apr 2019. doi:10.2519/jospt.2019.8144.
Collapse
|
5
|
Reeves NP, Luis A, Chan EC, Sal Y Rosas VG, Tanaka ML. Assessing delay and lag in sagittal trunk control using a tracking task. J Biomech 2018; 73:33-39. [PMID: 29599042 DOI: 10.1016/j.jbiomech.2018.03.029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2017] [Revised: 03/08/2018] [Accepted: 03/09/2018] [Indexed: 10/17/2022]
Abstract
Slower trunk muscle responses are linked to back pain and injury. Unfortunately, clinical assessments of spine function do not objectively evaluate this important attribute, which reflects speed of trunk control. Speed of trunk control can be parsed into two components: (1) delay, the time it takes to initiate a movement, and (2) lag, the time it takes to execute a movement once initiated. The goal of this study is to demonstrate a new approach to assess delay and lag in trunk control using a simple tracking task. Ten healthy subjects performed four blocks of six trials of trunk tracking in the sagittal plane. Delay and lag were estimated by modeling trunk control for predictable and unpredictable (control mode) trunk movements in flexion and extension (control direction) at movement amplitudes of 2°, 4°, and 6° (control amplitude). The main effect of control mode, direction, and amplitude of movement were compared between trial blocks to assess secondary influencers (e.g., fatigue). Only control mode was consistent across trial blocks with predictable movements being faster than unpredictable for both delay and lag. Control direction and amplitude effects on delay and lag were consistent across the first two trial blocks and less consistent in later blocks. Given the heterogeneity in the presentation of back pain, clinical assessment of trunk control should include different control modes, directions, and amplitudes. To reduce testing time and the influence of fatigue, we recommend six trials to assess trunk control.
Collapse
Affiliation(s)
| | - Abraham Luis
- Laboratorio de Investigacion en Biomecanica y Robotica Aplicada, Peru; Seccion de Ingenieria Mecanica, Pontificia Universidad Católica del Perú, Peru
| | - Elizabeth C Chan
- Department of Physical Medicine and Rehabilitation, New York University School of Medicine, USA
| | - Victor G Sal Y Rosas
- Sección de Matemáticas, Departamento de Ciencias, Pontificia Universidad Católica del Perú, Peru
| | - Martin L Tanaka
- School of Engineering and Technology, Western Carolina University, USA
| |
Collapse
|
6
|
Goodworth AD, Tetreault K, Lanman J, Klidonas T, Kim S, Saavedra S. Sensorimotor control of the trunk in sitting sway referencing. J Neurophysiol 2018; 120:37-52. [PMID: 29488840 DOI: 10.1152/jn.00330.2017] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
We developed a sway-referenced system for sitting to highlight the role of vestibular and visual contributions to trunk control. Motor control was investigated by measuring trunk kinematics in the frontal plane while manipulating visual availability and introducing a concurrent cognitive task. We examined motor learning on three timescales (within the same trial, minutes), within the same test session (1 h), and between sessions (1 wk). Posture sway was analyzed through time-based measures [root mean square (RMS) sway and RMS velocity], frequency-based measures (amplitude spectra), and parameterized feedback modeling. We found that posture differed in both magnitude and frequency distribution during sway referencing compared with quiet sitting. Modeling indicated that sway referencing caused greater uncertainty/noise in sensory feedback and motor outputs. Sway referencing was also associated with lower active stiffness and damping model parameters. The influence of vision and a cognitive task was more apparent during sway referencing compared with quiet sitting. Short-term learning was reflected by reduced RMS velocity in quiet sitting immediately following sway referencing. Longer term learning was evident from one week to the next, with a 23% decrease in RMS sway and 9% decrease in RMS velocity. These changes occurred predominantly during cognitive tests at lower frequencies and were associated with lower sensory noise and higher stiffness and integral gains in the model. With the findings taken together, the sitting sway-referenced test elicited neural changes consistent with optimal integration and sensory reweighting, similar to standing, and should be a valuable tool to closely examine sensorimotor control of the trunk. NEW & NOTEWORTHY We developed the first sway-referenced system for sitting to highlight the role of vestibular and visual contributions to trunk control. A parametric feedback model explained sensorimotor control and motor learning in the task with and between two test sessions. The sitting sway-referenced test elicited neural changes consistent with optimal integration and sensory reweighting, similar to standing, and should be a valuable tool to closely examine sensorimotor control of the trunk.
Collapse
Affiliation(s)
| | | | | | | | - Seyoung Kim
- Korea Institute of Machinery & Materials, Daejeon, Republic of Korea
| | | |
Collapse
|
7
|
Du W, Li H, Omisore OM, Wang L, Chen W, Sun X. Co-contraction characteristics of lumbar muscles in patients with lumbar disc herniation during different types of movement. Biomed Eng Online 2018; 17:8. [PMID: 29361944 PMCID: PMC5781330 DOI: 10.1186/s12938-018-0443-2] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2017] [Accepted: 01/16/2018] [Indexed: 01/24/2023] Open
Abstract
Background Muscular performance is an important factor for the mechanical stability of lumbar spine in humans, in which, the co-contraction of lumbar muscles plays a key role. We hypothesized that when executing different daily living motions, the performance of the lumbar muscle co-contraction stabilization mechanism varies between patients with lumbar disc herniation (LDH) and healthy controls. Hence, in this study, co-contraction performance of lumbar muscles between patients with LDH and healthy subjects was explored to check if there are significant differences between the two groups when performing four representative movements. Methods Twenty-six LDH patients (15 females, 11 males) and a control group of twenty-eight subjects (16 females, 12 males) were recruited. Surface electromyography (EMG) signals were recorded from the external oblique, lumbar multifidus, and internal oblique/transversus abdominis muscles during the execution of four types of movement, namely: forward bending, backward bending, left lateral flexion and right lateral flexion. The acquired EMG signals were segmented, and wavelet decomposition was performed followed by reconstruction of the low-frequency components of the signal. Then, the reconstructed signals were used for further analysis. Co-contraction ratio was employed to assess muscle coordination and compare it between the LDH patients and healthy controls. The corresponding signals of the subjects in the two groups were compared to evaluate the differences in agonistic and antagonistic muscle performance during the different motions. Also, sample entropy was applied to evaluate complexity changes in lumbar muscle recruitment during the movements. Results Significant differences between the LDH and control groups were found in the studied situations (p < 0.05). During the four movements considered in this study, the participants of the LDH group exhibited a higher level of co-contraction ratio, lower agonistic, and higher antagonistic lumbar muscle activity (p < 0.01) than those of the control group. Furthermore, the co-contraction ratio of LDH patients was dominated by the antagonistic muscle activity during the movements, except for the forward bending motion. However, in the healthy control group, the agonistic muscle activity contributed more to the co-contraction ratio with an exception for the backward bending motion. Conversely, the sample entropy value was significantly lower for agonistic muscles of LDH group compared to the control group (p < 0.01) while the entropy value was significantly greater in antagonistic muscles (p < 0.01) during the four types of movement, respectively. Conclusions Lumbar disc herniation patients exhibited numerous variations in the evaluated parameters that reflect the co-contraction of lumbar muscles, the agonistic and antagonistic muscle activities, and their respective sample entropy values when compared with the healthy control group. These variations could be due to the compensation mechanism that was required to stabilize the spine. The results of this study could facilitate the design of efficient rehabilitation methods for treatment of lumbar muscle dysfunctions.
Collapse
Affiliation(s)
- Wenjing Du
- Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, 1068 Xueyuan Boulevard, University Town of Shenzhen, Xili Nanshan, Shenzhen, 518055, China
| | - Huihui Li
- Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, 1068 Xueyuan Boulevard, University Town of Shenzhen, Xili Nanshan, Shenzhen, 518055, China
| | - Olatunji Mumini Omisore
- Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, 1068 Xueyuan Boulevard, University Town of Shenzhen, Xili Nanshan, Shenzhen, 518055, China.,Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen, 518055, China
| | - Lei Wang
- Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, 1068 Xueyuan Boulevard, University Town of Shenzhen, Xili Nanshan, Shenzhen, 518055, China.
| | - Wenmin Chen
- Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, 1068 Xueyuan Boulevard, University Town of Shenzhen, Xili Nanshan, Shenzhen, 518055, China.,Jiangxi University of Science and Technology, Jiangxi, China
| | - Xiangjun Sun
- Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, 1068 Xueyuan Boulevard, University Town of Shenzhen, Xili Nanshan, Shenzhen, 518055, China.,Jiangxi University of Science and Technology, Jiangxi, China
| |
Collapse
|
8
|
Ramadan A, Cholewicki J, Radcliffe CJ, Popovich JM, Reeves NP, Choi J. Reliability of assessing postural control during seated balancing using a physical human-robot interaction. J Biomech 2017; 64:198-205. [PMID: 29066244 DOI: 10.1016/j.jbiomech.2017.09.036] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2017] [Revised: 09/21/2017] [Accepted: 09/25/2017] [Indexed: 10/18/2022]
Abstract
This study evaluated the within- and between-visit reliability of a seated balance test for quantifying trunk motor control using input-output data. Thirty healthy subjects performed a seated balance test under three conditions: eyes open (EO), eyes closed (EC), and eyes closed with vibration to the lumbar muscles (VIB). Each subject performed three trials of each condition on three different visits. The seated balance test utilized a torque-controlled robotic seat, which together with a sitting subject resulted in a physical human-robot interaction (pHRI) (two degrees-of-freedom with upper and lower body rotations). Subjects balanced the pHRI by controlling trunk rotation in response to pseudorandom torque perturbations applied to the seat in the coronal plane. Performance error was expressed as the root mean square (RMSE) of deviations from the upright position in the time domain and as the mean bandpass signal energy (Emb) in the frequency domain. Intra-class correlation coefficients (ICC) quantified the between-visit reliability of both RMSE and Emb. The empirical transfer function estimates (ETFE) from the perturbation input to each of the two rotational outputs were calculated. Coefficients of multiple correlation (CMC) quantified the within- and between-visit reliability of the averaged ETFE. ICCs of RMSE and Emb for all conditions were ≥0.84. The mean within- and between-visit CMCs were all ≥0.96 for the lower body rotation and ≥0.89 for the upper body rotation. Therefore, our seated balance test consisting of pHRI to assess coronal plane trunk motor control is reliable.
Collapse
Affiliation(s)
- Ahmed Ramadan
- Department of Mechanical Engineering, College of Engineering, Michigan State University, East Lansing, MI, USA; MSU Center for Orthopedic Research, College of Osteopathic Medicine, Michigan State University, Lansing, MI, USA
| | - Jacek Cholewicki
- MSU Center for Orthopedic Research, College of Osteopathic Medicine, Michigan State University, Lansing, MI, USA; Department of Osteopathic Surgical Specialties, College of Osteopathic Medicine, Michigan State University, East Lansing, MI, USA
| | - Clark J Radcliffe
- Department of Mechanical Engineering, College of Engineering, Michigan State University, East Lansing, MI, USA; MSU Center for Orthopedic Research, College of Osteopathic Medicine, Michigan State University, Lansing, MI, USA; Department of Osteopathic Surgical Specialties, College of Osteopathic Medicine, Michigan State University, East Lansing, MI, USA
| | - John M Popovich
- MSU Center for Orthopedic Research, College of Osteopathic Medicine, Michigan State University, Lansing, MI, USA; Department of Osteopathic Surgical Specialties, College of Osteopathic Medicine, Michigan State University, East Lansing, MI, USA
| | - N Peter Reeves
- MSU Center for Orthopedic Research, College of Osteopathic Medicine, Michigan State University, Lansing, MI, USA; Department of Osteopathic Surgical Specialties, College of Osteopathic Medicine, Michigan State University, East Lansing, MI, USA
| | - Jongeun Choi
- MSU Center for Orthopedic Research, College of Osteopathic Medicine, Michigan State University, Lansing, MI, USA; School of Mechanical Engineering, Yonsei University, Seoul, Republic of Korea.
| |
Collapse
|
9
|
Pasma JH, Engelhart D, Maier AB, Aarts RGKM, van Gerven JMA, Arendzen JH, Schouten AC, Meskers CGM, van der Kooij H. Reliability of System Identification Techniques to Assess Standing Balance in Healthy Elderly. PLoS One 2016; 11:e0151012. [PMID: 26953694 PMCID: PMC4783059 DOI: 10.1371/journal.pone.0151012] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2015] [Accepted: 02/23/2016] [Indexed: 11/30/2022] Open
Abstract
Objectives System identification techniques have the potential to assess the contribution of the underlying systems involved in standing balance by applying well-known disturbances. We investigated the reliability of standing balance parameters obtained with multivariate closed loop system identification techniques. Methods In twelve healthy elderly balance tests were performed twice a day during three days. Body sway was measured during two minutes of standing with eyes closed and the Balance test Room (BalRoom) was used to apply four disturbances simultaneously: two sensory disturbances, to the proprioceptive and the visual system, and two mechanical disturbances applied at the leg and trunk segment. Using system identification techniques, sensitivity functions of the sensory disturbances and the neuromuscular controller were estimated. Based on the generalizability theory (G theory), systematic errors and sources of variability were assessed using linear mixed models and reliability was assessed by computing indexes of dependability (ID), standard error of measurement (SEM) and minimal detectable change (MDC). Results A systematic error was found between the first and second trial in the sensitivity functions. No systematic error was found in the neuromuscular controller and body sway. The reliability of 15 of 25 parameters and body sway were moderate to excellent when the results of two trials on three days were averaged. To reach an excellent reliability on one day in 7 out of 25 parameters, it was predicted that at least seven trials must be averaged. Conclusion This study shows that system identification techniques are a promising method to assess the underlying systems involved in standing balance in elderly. However, most of the parameters do not appear to be reliable unless a large number of trials are collected across multiple days. To reach an excellent reliability in one third of the parameters, a training session for participants is needed and at least seven trials of two minutes must be performed on one day.
Collapse
Affiliation(s)
- Jantsje H. Pasma
- Department of Rehabilitation Medicine, Leiden University Medical Center, Leiden, the Netherlands
- Department of Biomechanical Engineering, Delft University of Technology, Delft, the Netherlands
- * E-mail:
| | - Denise Engelhart
- Department of Biomechanical Engineering, Institute for Biomedical Technology and Technical Medicine (MIRA), University of Twente, Enschede, the Netherlands
| | - Andrea B. Maier
- Department of Medicine and Aged Care, Royal Melbourne Hospital, University of Melbourne, Melbourne, Australia
- Department of Human Movement Sciences, MOVE Research Institute Amsterdam, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Ronald G. K. M. Aarts
- Department of Mechanical Automation and Mechatronics, University of Twente, Enschede, the Netherlands
| | | | - J. Hans Arendzen
- Department of Rehabilitation Medicine, Leiden University Medical Center, Leiden, the Netherlands
| | - Alfred C. Schouten
- Department of Biomechanical Engineering, Delft University of Technology, Delft, the Netherlands
- Department of Biomechanical Engineering, Institute for Biomedical Technology and Technical Medicine (MIRA), University of Twente, Enschede, the Netherlands
| | - Carel G. M. Meskers
- Department of Rehabilitation Medicine, VU University Medical Center, Amsterdam, the Netherlands
| | - Herman van der Kooij
- Department of Biomechanical Engineering, Delft University of Technology, Delft, the Netherlands
- Department of Biomechanical Engineering, Institute for Biomedical Technology and Technical Medicine (MIRA), University of Twente, Enschede, the Netherlands
| |
Collapse
|
10
|
Trunk stabilization estimated using pseudorandom force perturbations, a reliability study. J Biomech 2015; 49:244-51. [PMID: 26708964 DOI: 10.1016/j.jbiomech.2015.12.007] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2015] [Revised: 11/25/2015] [Accepted: 12/03/2015] [Indexed: 11/23/2022]
Abstract
Measurement of the quality of trunk stabilization is of great interest to identify its role in first occurrence, recurrence or persistence of low-back pain (LBP). Our research group has developed and validated a method to quantify intrinsic and reflex contributions to trunk stabilization from the frequency response function (FRF) of thorax movement and trunk extensor EMG to perturbations applied by a linear actuator. However, the reliability of this method is still unknown. Therefore, the purpose of this study was to investigate the between-day reliability of trunk FRFs in healthy subjects and LBP patients. The test-retest ICC׳s in patients were substantial for both admittance and reflex gains (ICC3,1>0.73 and 0.67). In healthy subjects, the reliability of admittance gain was also substantial (ICC3,1 0.66), but the reliability of the reflexive gain was only moderate (ICC3,1 0.44). Although sample sizes were limited (13 healthy subjects and 18 LBP patients), these results show that trunk stabilization can be measured reliably, and represent a promising step towards using this method in further research in LBP patients.
Collapse
|
11
|
Popovich JM, Reeves NP, Priess MC, Cholewicki J, Choi J, Radcliffe CJ. Quantitative measures of sagittal plane head-neck control: a test-retest reliability study. J Biomech 2015; 48:549-54. [PMID: 25553673 DOI: 10.1016/j.jbiomech.2014.11.023] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2014] [Revised: 11/01/2014] [Accepted: 11/17/2014] [Indexed: 10/24/2022]
Abstract
Determining the reliability of measurements used to quantify head-neck motor control is necessary before they can be used to study the effects of injury or treatment interventions. Thus, the purpose of this study was to determine the within- and between-day reliability of position tracking, position stabilization and force tracking tasks to quantify head-neck motor control. Ten asymptomatic subjects performed these tasks on two separate days. Position and force tracking tasks required subjects to track a pseudorandom square wave input signal by controlling their head-neck angular position (position tracking) or the magnitude of isometric force generated against a force sensor by the neck musculature (force tracking) in the sagittal plane. Position stabilization required subjects to maintain an upright head position while pseudorandom perturbations were applied to the upper body using a robotic platform. Within-day and between-day reliability of the frequency response curves were assessed using coefficients of multiple correlations (CMC). Root mean square error (RMSE) and mean bandpass signal energy, were computed for each task and between-day reliability was calculated using intra-class correlation coefficients (ICC). Within- and between-day CMCs for the position and force tracking tasks were all ≥0.96, while CMCs for position stabilization ranged from 0.72 to 0.82. ICCs for the position and force tracking tasks were all ≥0.93. For position stabilization, ICCs for RMSE and mean bandpass signal energy were 0.66 and 0.72, respectively. Measures of sagittal plane head-neck motor control using position tracking, position stabilization and force tracking tasks were demonstrated to be reliable.
Collapse
Affiliation(s)
- John M Popovich
- MSU Center for Orthopedic Research, College of Osteopathic Medicine, Michigan State University, Lansing, MI, USA; Department of Osteopathic Surgical Specialties, College of Osteopathic Medicine, Michigan State University, East Lansing, MI, USA.
| | - N Peter Reeves
- MSU Center for Orthopedic Research, College of Osteopathic Medicine, Michigan State University, Lansing, MI, USA; Department of Osteopathic Surgical Specialties, College of Osteopathic Medicine, Michigan State University, East Lansing, MI, USA
| | - M Cody Priess
- MSU Center for Orthopedic Research, College of Osteopathic Medicine, Michigan State University, Lansing, MI, USA; Department of Mechanical Engineering, College of Engineering, Michigan State University, East Lansing, MI, USA
| | - Jacek Cholewicki
- MSU Center for Orthopedic Research, College of Osteopathic Medicine, Michigan State University, Lansing, MI, USA; Department of Osteopathic Surgical Specialties, College of Osteopathic Medicine, Michigan State University, East Lansing, MI, USA
| | - Jongeun Choi
- MSU Center for Orthopedic Research, College of Osteopathic Medicine, Michigan State University, Lansing, MI, USA; Department of Mechanical Engineering, College of Engineering, Michigan State University, East Lansing, MI, USA; Department of Electrical and Computer Engineering, College of Engineering, Michigan State University, East Lansing, MI, USA
| | - Clark J Radcliffe
- MSU Center for Orthopedic Research, College of Osteopathic Medicine, Michigan State University, Lansing, MI, USA; Department of Osteopathic Surgical Specialties, College of Osteopathic Medicine, Michigan State University, East Lansing, MI, USA; Department of Mechanical Engineering, College of Engineering, Michigan State University, East Lansing, MI, USA
| |
Collapse
|
12
|
Schinkel-Ivy A, DiMonte S, Drake JDM. Repeatability of kinematic and electromyographical measures during standing and trunk motion: how many trials are sufficient? J Electromyogr Kinesiol 2015; 25:232-8. [PMID: 25661241 DOI: 10.1016/j.jelekin.2014.12.007] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2014] [Revised: 11/26/2014] [Accepted: 12/26/2014] [Indexed: 11/19/2022] Open
Abstract
Previous studies have recommended a minimum of five trials to produce repeatable kinematic and electromyography (EMG) measures during target postures or contraction levels. This study aimed to evaluate the repeatability and reliability of kinematic and EMG measures that are of primary interest in the investigation of trunk movement, and to determine the number of trials required to achieve repeatability and reliability for these measures. Thirty participants performed ten trials of upright standing and maximum trunk ranges-of-motion. Mean (upright standing) and maximum (movement tasks) kinematic and EMG measures were assessed using intraclass correlation coefficients and standard error of measurement, which were used to identify the minimum number of trials for each measure. The repeatability and reliability of the measures were generally high, with 64%, 77%, 85%, and 92% of measures producing repeatable and reliable values with two, three, four, and five trials, respectively. Ten trials were not sufficient for several upright standing angle measures and maximum twist lumbar angles. Further, several abdominal muscles during maximum flexion, as well as the left lower-thoracic erector spinae during maximum twist, required as many as five trials. These measures were typically those with very small amounts of motion, or muscles that did not act in the role of prime mover. These results suggest that as few as two trials may be sufficient for many of the kinematic and EMG measures of primary interest in the investigation of trunk movement, while the collection of four trials should produce repeatable and reliable values for over 80% of measures. These recommendations are intended to provide an acceptable trade-off between repeatable and reliable values and feasibility of the collection protocol.
Collapse
Affiliation(s)
- Alison Schinkel-Ivy
- School of Kinesiology & Health Science, York University, 4700 Keele Street, Toronto, ON M3J 1P3, Canada
| | - Stephen DiMonte
- School of Kinesiology & Health Science, York University, 4700 Keele Street, Toronto, ON M3J 1P3, Canada
| | - Janessa D M Drake
- School of Kinesiology & Health Science, York University, 4700 Keele Street, Toronto, ON M3J 1P3, Canada.
| |
Collapse
|
13
|
Voglar M, Sarabon N. Reflex delays of the trunk muscles in response to postural perturbations: A reliability study. J Biomech 2014; 47:2807-12. [DOI: 10.1016/j.jbiomech.2014.05.024] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2013] [Revised: 05/29/2014] [Accepted: 05/30/2014] [Indexed: 10/25/2022]
|