1
|
Arshad R, Moglo K, El-Rich M, Schmidt H. Spinal loads during dynamic full flexion and return to standing posture in different age and sex groups: A musculoskeletal model study. J Biomech 2024; 172:112223. [PMID: 38986275 DOI: 10.1016/j.jbiomech.2024.112223] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Revised: 06/28/2024] [Accepted: 07/01/2024] [Indexed: 07/12/2024]
Abstract
During forward flexion, spine motion varies due to age and sex differences. Previous studies showed that lumbar/pelvis range of flexion (RoF) and lumbo-pelvic ratio (L/P) are age/sex dependent. How variation of these parameters affects lumbar loading in a normal population requires further assessment. We aimed to estimate lumbar loads during dynamic flexion-return cycle and the differences in peak loads (compression) and corresponding trunk inclinations due to variation in lumbar/pelvis RoF and L/P. Based on in vivo L/P (0.11-3.44), temporal phases of flexion (early, middle, and later), the lumbar (45-55°) and hip (60-79°) RoF; full flexion-return cycles of six seconds were reconstructed for three age groups (20-35, 36-50 and 50+ yrs.) in both sexes. Six inverse dynamic analyses were performed with a 50th percentile model, and differences in peak loads and corresponding trunk inclinations were calculated. Peak loads at L4-L5 were 179 N higher in younger males versus females, but 228 N and 210 N lower in middle-aged and older males, respectively, compared to females. Females exhibited higher trunk inclinations (6°-20°) than males across all age groups. Age related differences in L4-L5 peak loads and corresponding trunk inclinations were found up to 415 N and 19° in males and 152 N and 13° in females. With aging, peak loads were reduced in males but were found non-monotonic in females, whereas trunk inclinations at peak loads were reduced in both sexes from young to middle/old age groups. In conclusion, lumbar loading and corresponding trunk inclinations varied notably due to age/sex differences. Such data may help distinguishing normal or pathological condition of the lumbar spine.
Collapse
Affiliation(s)
- Rizwan Arshad
- Biomechanics Laboratory, Department of Mechanical and Aerospace Engineering, Royal Military College of Canada, Kingston, Ontario K7K7B4, Canada; Julius Wolff Institute, Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Augustenburger Platz 1 13353, Berlin, Germany
| | - Kodjo Moglo
- Biomechanics Laboratory, Department of Mechanical and Aerospace Engineering, Royal Military College of Canada, Kingston, Ontario K7K7B4, Canada
| | - Marwan El-Rich
- Healthcare Engineering Innovation Center (HEIC), Department of Mechanical Engineering, Khalifa University, Abu Dhabi, United Arab Emirates
| | - Hendrik Schmidt
- Julius Wolff Institute, Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Augustenburger Platz 1 13353, Berlin, Germany.
| |
Collapse
|
2
|
Remus R, Selkmann S, Lipphaus A, Neumann M, Bender B. Muscle-driven forward dynamic active hybrid model of the lumbosacral spine: combined FEM and multibody simulation. Front Bioeng Biotechnol 2023; 11:1223007. [PMID: 37829567 PMCID: PMC10565495 DOI: 10.3389/fbioe.2023.1223007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Accepted: 09/05/2023] [Indexed: 10/14/2023] Open
Abstract
Most spine models belong to either the musculoskeletal multibody (MB) or finite element (FE) method. Recently, coupling of MB and FE models has increasingly been used to combine advantages of both methods. Active hybrid FE-MB models, still rarely used in spine research, avoid the interface and convergence problems associated with model coupling. They provide the inherent ability to account for the full interplay of passive and active mechanisms for spinal stability. In this paper, we developed and validated a novel muscle-driven forward dynamic active hybrid FE-MB model of the lumbosacral spine (LSS) in ArtiSynth to simultaneously calculate muscle activation patterns, vertebral movements, and internal mechanical loads. The model consisted of the rigid vertebrae L1-S1 interconnected with hyperelastic fiber-reinforced FE intervertebral discs, ligaments, facet joints, and force actuators representing the muscles. Morphological muscle data were implemented via a semi-automated registration procedure. Four auxiliary bodies were utilized to describe non-linear muscle paths by wrapping and attaching the anterior abdominal muscles. This included an abdominal plate whose kinematics was optimized using motion capture data from upper body movements. Intra-abdominal pressure was calculated from the forces of the abdominal muscles compressing the abdominal cavity. For the muscle-driven approach, forward dynamics assisted data tracking was used to predict muscle activation patterns that generate spinal postures and balance the spine without prescribing accurate spinal kinematics. During calibration, the maximum specific muscle tension and spinal rhythms resulting from the model dynamics were evaluated. To validate the model, load cases were simulated from -10° extension to +30° flexion with weights up to 20 kg in both hands. The biomechanical model responses were compared with in vivo literature data of intradiscal pressures, intra-abdominal pressures, and muscle activities. The results demonstrated high agreement with this data and highlight the advantages of active hybrid modeling for the LSS. Overall, this new self-contained tool provides a robust and efficient estimation of LSS biomechanical responses under in vivo similar loads, for example, to improve pain treatment by spinal stabilization therapies.
Collapse
Affiliation(s)
- Robin Remus
- Chair of Product Development, Department of Mechanical Engineering, Ruhr-University Bochum, Bochum, Germany
| | - Sascha Selkmann
- Chair of Product Development, Department of Mechanical Engineering, Ruhr-University Bochum, Bochum, Germany
| | - Andreas Lipphaus
- Biomechanics Research Group, Chair of Product Development, Department of Mechanical Engineering, Ruhr-University Bochum, Bochum, Germany
| | - Marc Neumann
- Chair of Product Development, Department of Mechanical Engineering, Ruhr-University Bochum, Bochum, Germany
| | - Beate Bender
- Chair of Product Development, Department of Mechanical Engineering, Ruhr-University Bochum, Bochum, Germany
| |
Collapse
|
3
|
Zadoń H, Michnik R, Nowakowska-Lipiec K. Exploring the impact of body mass change on fatigue and activity of the muscular system during daily routine. Technol Health Care 2023; 31:2487-2498. [PMID: 37955073 DOI: 10.3233/thc-235014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2023]
Abstract
BACKGROUND Correct body weight is one of the factors that allows you to maintain a properly functioning body. Abnormal body weight can cause muscle tissue remodelling, affecting activity and muscle fatigue. Changes in the muscular system can cause occurrence of functional limitations. OBJECTIVE To determine the effect of weight change on fatigue and activity of the muscular system during daily activities. METHODS The evaluation of musculoskeletal functioning was based on the results of computer simulations conducted in the AnyBody Modeling System. The following activities were analysed: standing, sitting down and getting up from a chair, holding and lifting an object, and walking. The simulations of the activities were carried out using averaged kinematic data, and by changing body mass in the range of 50 kg to 100 kg by increments of 2 kg, to map different nutritional status from excessive thinness to extreme obesity. Identification of loads in the musculoskeletal system was based on solving an inverse dynamics problem and then the estimation of muscle force values using static optimization. The simulation results allowed to determine the value of muscle fatigue and the level of muscle activity. RESULTS For activities (i.e., standing, walking, sitting down and getting up from a chair) it was observed that the value of muscle fatigue increases with increasing body mass. However, for activities that cause more load on the musculoskeletal system, i.e. lifting and holding an object, the highest value of muscle fatigue was observed in underweight individuals. CONCLUSION The change in body weight alters the functioning of the muscular system and thus the ability to perform activities. It was shown that in case of underweight, overweight or obese people, abnormal body weight can be the reason for occurrence of difficulties in performing the activities of lifting and holding a 20 kg object, as well as walking.
Collapse
|
4
|
Kim SJ, Wang T, Pelletier MH, Walsh WR. 'SMART' implantable devices for spinal implants: a systematic review on current and future trends. JOURNAL OF SPINE SURGERY (HONG KONG) 2022; 8:117-131. [PMID: 35441100 DOI: 10.21037/jss-21-100] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Accepted: 02/28/2022] [Indexed: 01/18/2023]
Abstract
Background 'SMART' implants refer to modified orthopedic implants that combine the biomechanical safety and efficacy of traditional devices with the intelligence of data-logging sensors. This review aims to systematically assess the available literature on SMART spinal implants and present these findings in a clinically relevant manner. Methods A search of PubMed, Scopus, and Google Scholar databases was conducted by two separate reviewers. Information including sensor type, intended application, and sample size, was extracted from included studies. Risk of bias assessment was conducted using the Office of Health Assessment and Translation (OHAT) risk of bias tool. Results Eighteen studies were included for analysis. Eight studies involved SMART rods and ten studies used SMART vertebral body replacements (VBR). No more than 20 patients are reported to have received a SMART spinal implant. Including non-primary evidence, seven unique designs for SMART spinal implants were found. The majority of these used strain gauges with recent designs including thermometers and accelerometers. Discussion At present, SMART spinal implants have primarily focused on utilising strain gauges to report loading on the implant itself. This is a logical first step as it allows quantification of real-world requirements of an implant, detection of catastrophic failure, while also allowing researchers and clinicians to estimate changes in load sharing between newly forming bone and the implant itself, providing real-time information on the progression of healing and fusion. Future work includes documenting the correlation between data provided by these SMART implants and clinical findings, including complications such as pedicle screw loosening and interbody cage subsidence.
Collapse
Affiliation(s)
- Sihyong J Kim
- Faculty of Medicine, University of New South Wales (UNSW), Sydney, Australia.,Surgical and Orthopaedics Research Laboratory, Prince of Wales Hospital, Randwick, NSW, Australia
| | - Tian Wang
- Surgical and Orthopaedics Research Laboratory, Prince of Wales Hospital, Randwick, NSW, Australia
| | - Matthew H Pelletier
- Surgical and Orthopaedics Research Laboratory, Prince of Wales Hospital, Randwick, NSW, Australia
| | - William R Walsh
- Surgical and Orthopaedics Research Laboratory, Prince of Wales Hospital, Randwick, NSW, Australia
| |
Collapse
|
5
|
Remus R, Lipphaus A, Neumann M, Bender B. Calibration and validation of a novel hybrid model of the lumbosacral spine in ArtiSynth-The passive structures. PLoS One 2021; 16:e0250456. [PMID: 33901222 PMCID: PMC8075237 DOI: 10.1371/journal.pone.0250456] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2020] [Accepted: 04/07/2021] [Indexed: 12/04/2022] Open
Abstract
In computational biomechanics, two separate types of models have been used predominantly to enhance the understanding of the mechanisms of action of the lumbosacral spine (LSS): Finite element (FE) and musculoskeletal multibody (MB) models. To combine advantages of both models, hybrid FE-MB models are an increasingly used alternative. The aim of this paper is to develop, calibrate, and validate a novel passive hybrid FE-MB open-access simulation model of a ligamentous LSS using ArtiSynth. Based on anatomical data from the Male Visible Human Project, the LSS model is constructed from the L1-S1 rigid vertebrae interconnected with hyperelastic fiber-reinforced FE intervertebral discs, ligaments, and facet joints. A mesh convergence study, sensitivity analyses, and systematic calibration were conducted with the hybrid functional spinal unit (FSU) L4/5. The predicted mechanical responses of the FSU L4/5, the lumbar spine (L1-L5), and the LSS were validated against literature data from in vivo and in vitro measurements and in silico models. Spinal mechanical responses considered when loaded with pure moments and combined loading modes were total and intervertebral range of motions, instantaneous axes and centers of rotation, facet joint contact forces, intradiscal pressures, disc bulges, and stiffnesses. Undesirable correlations with the FE mesh were minimized, the number of crisscrossed collagen fiber rings was reduced to five, and the individual influences of specific anatomical structures were adjusted to in vitro range of motions. Including intervertebral motion couplings for axial rotation and nonlinear stiffening under increasing axial compression, the predicted kinematic and structural mechanics responses were consistent with the comparative data. The results demonstrate that the hybrid simulation model is robust and efficient in reproducing valid mechanical responses to provide a starting point for upcoming optimizations and extensions, such as with active skeletal muscles.
Collapse
Affiliation(s)
- Robin Remus
- Chair of Product Development, Department of Mechanical Engineering, Ruhr-University Bochum, Bochum, Germany
- * E-mail:
| | - Andreas Lipphaus
- Biomechanics Research Group, Chair of Product Development, Department of Mechanical Engineering, Ruhr-University Bochum, Bochum, Germany
| | - Marc Neumann
- Chair of Product Development, Department of Mechanical Engineering, Ruhr-University Bochum, Bochum, Germany
| | - Beate Bender
- Chair of Product Development, Department of Mechanical Engineering, Ruhr-University Bochum, Bochum, Germany
| |
Collapse
|
6
|
Nowakowska-Lipiec K, Michnik R, Linek P, Myśliwiec A, Jochymczyk-Woźniak K, Gzik M. A numerical study to determine the effect of strengthening and weakening of the transversus abdominis muscle on lumbar spine loads. Comput Methods Biomech Biomed Engin 2020; 23:1287-1296. [DOI: 10.1080/10255842.2020.1795840] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Affiliation(s)
- Katarzyna Nowakowska-Lipiec
- Department of Biomechatronics, Faculty of Biomedical Engineering, Silesian University of Technology, Gliwice, Poland
| | - Robert Michnik
- Department of Biomechatronics, Faculty of Biomedical Engineering, Silesian University of Technology, Gliwice, Poland
| | - Paweł Linek
- Institute of Physiotherapy and Health Sciences, Musculoskeletal Elastography and Ultrasonography Laboratory, The Jerzy Kukuczka Academy of Physical Education, Katowice, Poland
| | - Andrzej Myśliwiec
- Institute of Physiotherapy and Health Sciences, Laboratory of Physiotherapy and Physioprevention, The Jerzy Kukuczka Academy of Physical Education, Katowice, Poland
| | - Katarzyna Jochymczyk-Woźniak
- Department of Biomechatronics, Faculty of Biomedical Engineering, Silesian University of Technology, Gliwice, Poland
| | - Marek Gzik
- Department of Biomechatronics, Faculty of Biomedical Engineering, Silesian University of Technology, Gliwice, Poland
| |
Collapse
|
7
|
Which is the best-suited landmark to assess the thoracic orientation? J Biomech 2020; 102:109545. [PMID: 31787259 DOI: 10.1016/j.jbiomech.2019.109545] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2019] [Revised: 10/29/2019] [Accepted: 11/20/2019] [Indexed: 11/22/2022]
Abstract
Several skin surface-based techniques exist to non-invasively determine the spinal kinematics. However, the accuracy of these techniques is limited by soft-tissue artefacts. Furthermore, structures like the thorax are frequently assumed to be rigid but display considerable mobility within itself. This study aimed to quantify the accuracy at different thoracic landmarks for measuring mobility in healthy individuals during different activities to provide a recommendation for the best suited measurement location. The locations of 29 landmarks were continuously captured on 19 individuals (age: 25-59 years) during sitting, standing, walking, jumping, intra-thoracic motions, and different breathing depths using reflective markers. Marker triplets were used at every landmark to calculate their orientations by first backtracking the rigid-body motion (RBM) of the thorax in general, and subsequently calculating the RBM of each rigid marker triplet. Of the latter, the maximum axis angle for each exercise was statistically evaluated. Landmarks at the middle of the clavicles displayed the largest overall errors (approximately 90° during worst case scenario). However, the variability of errors among the investigated exercises was large. Landmarks at the cranial sternal region (particularly at the "Louis angle") and at the T3 spinous process showed the smallest errors for all subjects and tasks (e.g., <5° and <11°, respectively, during normal breathing). When only one sensor is to be used, it is recommended to use the cranial sternal region to assess the thoracic orientation. Study results highly sensitive to thoracic orientation should be considered with care or performed using more appropriate methods.
Collapse
|
8
|
Ghezelbash F, Shirazi-Adl A, El Ouaaid Z, Plamondon A, Arjmand N. Subject-specific regression equations to estimate lower spinal loads during symmetric and asymmetric static lifting. J Biomech 2020; 102:109550. [DOI: 10.1016/j.jbiomech.2019.109550] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2019] [Revised: 11/26/2019] [Accepted: 11/29/2019] [Indexed: 01/11/2023]
|
9
|
Zhang H, Zhu W. The Path to Deliver the Most Realistic Follower Load for a Lumbar Spine in Standing Posture: A Finite Element Study. J Biomech Eng 2019; 141:2720655. [DOI: 10.1115/1.4042438] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2018] [Indexed: 11/08/2022]
Abstract
A spine is proven to be subjected to a follower load which is a compressive load of physiologic magnitude acting on the whole spine. The path of the follower load approximates the tangent to the curve of the spine in in vivo neutral standing posture. However, the specific path location of the follower load is still unclear. The aim of this study is to find out the most realistic location of the follower load path (FLP) for a lumbar spine in standing. A three-dimensional (3D) nonlinear finite element model (FEM) of lumbosacral vertebrae (L1-S1) with consideration of the calibrated material properties was established and validated by comparing with the experimental data. We show that the shape of the lumbosacral spine is strongly affected by the location of FLP. An evident nonlinear relationship between the FLP location and the kinematic response of the L1-S1 lumbosacral spine exists. The FLP at about 4 and 3 mm posterior to the curve connecting the center of the vertebral bodies delivers the most realistic location in standing for healthy people and patients having low back pains (LPBs), respectively. Moreover, the “sweeping” method introduced in this study can be applicable to all individualized FEM to determine the location of FLP.
Collapse
Affiliation(s)
- Han Zhang
- Shanghai Institute of Applied Mathematics and Mechanics, Shanghai University, Shanghai, 200072, China
| | - Weiping Zhu
- Shanghai Institute of Applied Mathematics and Mechanics, Shanghai University, Shanghai, 200072, China e-mail:
| |
Collapse
|
10
|
Karipott SS, Nelson BD, Guldberg RE, Ong KG. Clinical potential of implantable wireless sensors for orthopedic treatments. Expert Rev Med Devices 2018; 15:255-264. [PMID: 29558820 DOI: 10.1080/17434440.2018.1454310] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION Implantable wireless sensors have been used for real-time monitoring of chemicals and physical conditions of bones, tendons and muscles to diagnose and study orthopedic diseases and injuries. Due to the importance of these sensors in orthopedic care, a critical review, which not only analyzes the underlying technologies but also their clinical implementations and challenges, will provide a landscape view on their current state and their future clinical role. AREAS COVERED By conducting an extensive literature search and following the leaders of orthopedic implantable wireless sensors, this review covers the battery-powered and battery-free wireless implantable sensor technologies, and describes their implementation for hips, knees, spine, and shoulder stress/strain monitoring. Their advantages, limitations, and clinical challenges are also described. EXPERT COMMENTARY Currently, implantable wireless sensors are mostly limited for scientific investigations and demonstrative experiments. Although rapid advancement in sensors and wireless technologies will push the reliability and practicality of these sensors for clinical realization, regulatory constraints and financial viability in medical device industry may curtail their continuous adoption for clinical orthopedic applications. In the next five years, these sensors are expected to gain increased interest from researchers, but wide clinical adoption is still unlikely.
Collapse
Affiliation(s)
| | - Bradley D Nelson
- a Biomedical Engineering , Michigan Technological University , Houghton , MI , USA
| | - Robert E Guldberg
- b George W. Woodruff School of Mechanical Engineering , Georgia Institute of Technology , Atlanta , GA , USA
| | - Keat Ghee Ong
- a Biomedical Engineering , Michigan Technological University , Houghton , MI , USA
| |
Collapse
|
11
|
Mueller J, Engel T, Mueller S, Stoll J, Baur H, Mayer F. Effects of sudden walking perturbations on neuromuscular reflex activity and three-dimensional motion of the trunk in healthy controls and back pain symptomatic subjects. PLoS One 2017; 12:e0174034. [PMID: 28319133 PMCID: PMC5358879 DOI: 10.1371/journal.pone.0174034] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2016] [Accepted: 03/02/2017] [Indexed: 12/19/2022] Open
Abstract
Background Back pain patients (BPP) show delayed muscle onset, increased co-contractions, and variability as response to quasi-static sudden trunk loading in comparison to healthy controls (H). However, it is unclear whether these results can validly be transferred to suddenly applied walking perturbations, an automated but more functional and complex movement pattern. There is an evident need to develop research-based strategies for the rehabilitation of back pain. Therefore, the investigation of differences in trunk stability between H and BPP in functional movements is of primary interest in order to define suitable intervention regimes. The purpose of this study was to analyse neuromuscular reflex activity as well as three-dimensional trunk kinematics between H and BPP during walking perturbations. Methods Eighty H (31m/49f;29±9yrs;174±10cm;71±13kg) and 14 BPP (6m/8f;30±8yrs;171±10cm;67±14kg) walked (1m/s) on a split-belt treadmill while 15 right-sided perturbations (belt decelerating, 40m/s2, 50ms duration; 200ms after heel contact) were randomly applied. Trunk muscle activity was assessed using a 12-lead EMG set-up. Trunk kinematics were measured using a 3-segment-model consisting of 12 markers (upper thoracic (UTA), lower thoracic (LTA), lumbar area (LA)). EMG-RMS ([%],0-200ms after perturbation) was calculated and normalized to the RMS of unperturbed gait. Latency (TON;ms) and time to maximum activity (TMAX;ms) were analysed. Total motion amplitude (ROM;[°]) and mean angle (Amean;[°]) for extension-flexion, lateral flexion and rotation were calculated (whole stride cycle; 0-200ms after perturbation) for each of the three segments during unperturbed and perturbed gait. For ROM only, perturbed was normalized to unperturbed step [%] for the whole stride as well as the 200ms after perturbation. Data were analysed descriptively followed by a student´s t-test to account for group differences. Co-contraction was analyzed between ventral and dorsal muscles (V:R) as well as side right:side left ratio (Sright:Sleft). The coefficient of variation (CV;%) was calculated (EMG-RMS;ROM) to evaluate variability between the 15 perturbations for all groups. With respect to unequal distribution of participants to groups, an additional matched-group analysis was conducted. Fourteen healthy controls out of group H were sex-, age- and anthropometrically matched (group Hmatched) to the BPP. Results No group differences were observed for EMG-RMS or CV analysis (EMG/ROM) (p>0.025). Co-contraction analysis revealed no differences for V:R and Srigth:Sleft between the groups (p>0.025). BPP showed an increased TON and TMAX, being significant for Mm. rectus abdominus (p = 0.019) and erector spinae T9/L3 (p = 0.005/p = 0.015). ROM analysis over the unperturbed stride cycle revealed no differences between groups (p>0.025). Normalization of perturbed to unperturbed step lead to significant differences for the lumbar segment (LA) in lateral flexion with BPP showing higher normalized ROM compared to Hmatched (p = 0.02). BPP showed a significant higher flexed posture (UTA (p = 0.02); LTA (p = 0.004)) during normal walking (Amean). Trunk posture (Amean) during perturbation showed higher trunk extension values in LTA segments for H/Hmatched compared to BPP (p = 0.003). Matched group (BPP vs. Hmatched) analysis did not show any systematic changes of all results between groups. Conclusion BPP present impaired muscle response times and trunk posture, especially in the sagittal and transversal planes, compared to H. This could indicate reduced trunk stability and higher loading during gait perturbations.
Collapse
Affiliation(s)
- Juliane Mueller
- University Outpatient Clinic, Sports Medicine & Sports Orthopaedics, University of Potsdam, Germany
- * E-mail:
| | - Tilman Engel
- University Outpatient Clinic, Sports Medicine & Sports Orthopaedics, University of Potsdam, Germany
| | - Steffen Mueller
- University Outpatient Clinic, Sports Medicine & Sports Orthopaedics, University of Potsdam, Germany
| | - Josefine Stoll
- University Outpatient Clinic, Sports Medicine & Sports Orthopaedics, University of Potsdam, Germany
| | - Heiner Baur
- Bern University of Applied Sciences, Health, Physiotherapy, Bern, Switzerland
| | - Frank Mayer
- University Outpatient Clinic, Sports Medicine & Sports Orthopaedics, University of Potsdam, Germany
| |
Collapse
|
12
|
Naserkhaki S, El-Rich M. Sensitivity of lumbar spine response to follower load and flexion moment: finite element study. Comput Methods Biomech Biomed Engin 2016; 20:550-557. [PMID: 27848266 DOI: 10.1080/10255842.2016.1257707] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
The follower load (FL) combined with moments is commonly used to approximate flexed/extended posture of the lumbar spine in absence of muscles in biomechanical studies. There is a lack of consensus as to what magnitudes simulate better the physiological conditions. Considering the in-vivo measured values of the intradiscal pressure (IDP), intervertebral rotations (IVRs) and the disc loads, sensitivity of these spinal responses to different FL and flexion moment magnitudes was investigated using a 3D nonlinear finite element (FE) model of ligamentous lumbosacral spine. Optimal magnitudes of FL and moment that minimize deviation of the model predictions from in-vivo data were determined. Results revealed that the spinal parameters i.e. the IVRs, disc moment, and the increase in disc force and moment from neutral to flexed posture were more sensitive to moment magnitude than FL magnitude in case of flexion. The disc force and IDP were more sensitive to the FL magnitude than moment magnitude. The optimal ranges of FL and flexion moment magnitudes were 900-1100 N and 9.9-11.2 Nm, respectively. The FL magnitude had reverse effect on the IDP and disc force. Thus, magnitude for FL or flexion that minimizes the deviation of all the spinal parameters together from the in-vivo data can vary. To obtain reasonable compromise between the IDP and disc force, our findings recommend that FL of low magnitude must be combined with flexion moment of high intensity and vice versa.
Collapse
Affiliation(s)
- Sadegh Naserkhaki
- a Department of Civil and Environmental Engineering , University of Alberta , Edmonton , Canada
| | - Marwan El-Rich
- a Department of Civil and Environmental Engineering , University of Alberta , Edmonton , Canada
| |
Collapse
|
13
|
Ghezelbash F, Shirazi-Adl A, Arjmand N, El-Ouaaid Z, Plamondon A, Meakin J. Effects of sex, age, body height and body weight on spinal loads: Sensitivity analyses in a subject-specific trunk musculoskeletal model. J Biomech 2016; 49:3492-3501. [DOI: 10.1016/j.jbiomech.2016.09.026] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2016] [Revised: 09/15/2016] [Accepted: 09/16/2016] [Indexed: 02/02/2023]
|
14
|
Subject-specific biomechanics of trunk: musculoskeletal scaling, internal loads and intradiscal pressure estimation. Biomech Model Mechanobiol 2016; 15:1699-1712. [DOI: 10.1007/s10237-016-0792-3] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2015] [Accepted: 04/25/2016] [Indexed: 10/21/2022]
|
15
|
Naserkhaki S, Jaremko JL, Adeeb S, El-Rich M. On the load-sharing along the ligamentous lumbosacral spine in flexed and extended postures: Finite element study. J Biomech 2015; 49:974-982. [PMID: 26493346 DOI: 10.1016/j.jbiomech.2015.09.050] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2015] [Revised: 09/11/2015] [Accepted: 09/27/2015] [Indexed: 10/22/2022]
Abstract
A harmonic synergy between the load-bearing and stabilizing components of the spine is necessary to maintain its normal function. This study aimed to investigate the load-sharing along the ligamentous lumbosacral spine under sagittal loading. A 3D nonlinear detailed Finite Element (FE) model of lumbosacral spine with realistic geometry was developed and validated using wide range of numerical and experimental (in-vivo and in-vitro) data. The model was subjected to 500 N compressive Follower Load (FL) combined with 7.5 Nm flexion (FLX) or extension (EXT) moments. Load-sharing was expressed as percentage of total internal force/moment developed along the spine that each spinal component carried. These internal forces and moments were determined at the discs centres and included the applied load and the resisting forces in the ligaments and facet joints. The contribution of the facet joints and ligaments in supporting bending moments produced additional forces and moments in the discs. The intervertebral discs carried up to 81% and 68% of the total internal force in case of FL combined with FLX and EXT, respectively. The ligaments withstood up to 67% and 81% of the total internal moment in cases of FL combined with EXT and FLX, respectively. Contribution of the facet joints in resisting internal force and moment was noticeable at levels L4-S1 only particularly in case of FL combined with EXT and reached up 29% and 52% of the internal moment and force, respectively. This study demonstrated that spinal load-sharing depended on applied load and varied along the spine.
Collapse
Affiliation(s)
- Sadegh Naserkhaki
- Department of Civil and Environmental Engineering, University of Alberta, Canada
| | - Jacob L Jaremko
- Department of Radiology and Diagnostic Imaging, University of Alberta, Canada
| | - Samer Adeeb
- Department of Civil and Environmental Engineering, University of Alberta, Canada
| | - Marwan El-Rich
- Department of Civil and Environmental Engineering, University of Alberta, Canada.
| |
Collapse
|
16
|
The effects of age and gender on the lumbopelvic rhythm in the sagittal plane in 309 subjects. J Biomech 2015; 48:3080-7. [DOI: 10.1016/j.jbiomech.2015.07.030] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2015] [Revised: 07/07/2015] [Accepted: 07/19/2015] [Indexed: 11/30/2022]
|