Garofalo S, Morano C, Bruno L, Pagnotta L. A Comprehensive Literature Review for Total Hip Arthroplasty (THA): Part 2-Material Selection Criteria and Methods. J Funct Biomater 2025; 16:184. [PMID: 40422848 DOI: 10.3390/jfb16050184] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2025] [Revised: 05/05/2025] [Accepted: 05/15/2025] [Indexed: 05/28/2025] Open
Abstract
Total Hip Arthroplasty (THA) is a widely used surgical procedure to restore mobility and reduce pain in patients with hip joint disorders. Implant success and longevity are influenced by the selection of appropriate materials. This study presents a comprehensive literature review based on structured searches in Scopus and Web of Science, focusing on material selection criteria and methods in THA. The inclusion criteria targeted original studies and reviews addressing material properties, selection techniques, and clinical performance. A bibliometric analysis and keyword co-occurrence network were used to highlight major research themes. The review examines traditional materials such as Metal-on-Polyethylene (MoP), as well as advanced options like ceramics, composites, and Functionally Graded Materials (FGMs). Key challenges discussed include aseptic loosening, wear resistance, and stress shielding. Selection methodologies such as Multi-Criteria Decision-Making (MCDM), Weighted Properties Methods (WPM), and computational tools like Ashby charts and CES Selector are analyzed. The findings from international arthroplasty registries show that more than half of implant failures are linked to material-related factors. This study therefore aims to guide material selection processes in THA by aligning clinical performance with biomechanical and biological requirements, supporting improved implant outcomes and long-term surgical success. Future developments should focus on patient-specific solutions and continuous innovation.
Collapse
Affiliation(s)
- Salvatore Garofalo
- Department of Mechanical, Energy and Management Engineering, University of Calabria, Via P. Bucci 44C, 87036 Rende, Italy
| | - Chiara Morano
- Department of Mechanical, Energy and Management Engineering, University of Calabria, Via P. Bucci 44C, 87036 Rende, Italy
| | - Luigi Bruno
- Department of Mechanical, Energy and Management Engineering, University of Calabria, Via P. Bucci 44C, 87036 Rende, Italy
| | - Leonardo Pagnotta
- Department of Mechanical, Energy and Management Engineering, University of Calabria, Via P. Bucci 44C, 87036 Rende, Italy
| |
Collapse
|
2
|
Baba K, Mori Y, Tanaka H, Kanabuchi R, Kuriyama Y, Kurishima H, Ito K, Kamimura M, Chiba D, Aizawa T. Effectiveness of Stress Shielding Prevention Using a Low Young's Modulus Ti-33.6Nb-4Sn Stem: A 7-Year Follow-Up Study. Med Sci (Basel) 2025; 13:51. [PMID: 40407546 PMCID: PMC12101376 DOI: 10.3390/medsci13020051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2025] [Revised: 04/29/2025] [Accepted: 04/29/2025] [Indexed: 05/26/2025] Open
Abstract
BACKGROUND Stress shielding (SS) after total hip arthroplasty (THA) leads to proximal femoral bone loss and increases the risk of complications such as implant loosening and periprosthetic fracture. While various low-stiffness stems have been developed to prevent SS, they often compromise mechanical stability. A novel femoral stem composed of Ti-33.6Nb-4Sn (TNS) alloy offers a gradually decreasing Young's modulus from proximal to distal regions, potentially improving load distribution and reducing SS. This study aimed to evaluate the mid-term clinical and radiographic outcomes of the TNS stem, with a particular focus on its effectiveness in suppressing SS. METHODS A prospective clinical study was conducted involving 35 patients who underwent THA using the TNS stem, with a minimum follow-up of 7 years. Twenty-one patients with Ti6Al4V metaphyseal-filling stems served as controls. Clinical outcomes were assessed using Japanese Orthopaedic Association (JOA) scores, and radiographic SS was graded using Engh's classification and analyzed in Gruen zones. Inter-examiner reliability and statistical comparisons between groups were performed using appropriate tests. RESULTS The TNS group showed significantly higher preoperative JOA scores than the control group, but no significant difference in final scores. Both groups demonstrated significant improvement postoperatively. Third-degree SS occurred in the TNS group, although the overall SS grade distribution was significantly lower than in the control group (p = 0.03). SS frequency was significantly reduced in Gruen Zones 2, 3, and 6 in the TNS group. CONCLUSIONS The TNS stem demonstrated a significant reduction in SS progression compared to conventional titanium stems over a 7-year period, with comparable clinical outcomes. However, the occurrence of third-degree SS indicates that material optimization alone may be insufficient, highlighting the need for further design improvements.
Collapse
Affiliation(s)
| | - Yu Mori
- Department of Orthopaedic Surgery, Tohoku University Graduate School of Medicine, Sendai 980-8574, Japan; (K.B.); (H.T.); (R.K.); (Y.K.); (H.K.); (K.I.); (M.K.); (D.C.)
| | | | | | | | | | | | | | | | | |
Collapse
|
3
|
Koyama T, Mori Y, Kamimura M, Tanaka H, Tome R, Ito K, Koguchi M, Mori N, Aizawa T. TiNbSn alloy plates with low Young's modulus modulates interfragmentary movement and promote osteosynthesis in rat femur. J Mech Behav Biomed Mater 2025; 161:106820. [PMID: 39566162 DOI: 10.1016/j.jmbbm.2024.106820] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2024] [Revised: 10/28/2024] [Accepted: 11/15/2024] [Indexed: 11/22/2024]
Abstract
Orthopedic implants such as arthroplasty prostheses, fracture plates, and intramedullary nails often use materials like Ti6Al4V alloy and commercially pure titanium (CP-Ti), which have Young's modulus significantly higher than that of human cortical bone, potentially causing stress shielding and inhibiting effective fracture healing. TiNbSn alloy, a β-type titanium alloy with a lower Young's modulus (40-49 GPa), has shown promise in reducing stress shielding and enhancing bone healing by promoting effective load sharing with bone. This study used 5-hole plates made from TiNbSn alloy and CP-Ti to investigate their effects on bone healing in a rat femoral fracture model. Micro-CT analysis and mechanical testing were performed six weeks postoperatively to assess bone healing. Additionally, Finite element method (FEM) analysis was employed to evaluate stress shielding and interfragmentary movement (IFM) at the fracture site. Micro-CT analysis revealed significantly higher bone volume and mineral density in the TiNbSn group than in the CP-Ti group. Mechanical testing showed increased maximum load and stiffness in the TiNbSn group (77.2 ± 10.0 N for the TiNbSn alloy plate group versus 53.3 ± 8.5 N for the CP-Ti group (p = 0.002)). FEM analysis indicated that TiNbSn plates reduced stress shielding and allowed for greater displacement and strain, promoting IFM conducive to bone healing. The findings suggest that TiNbSn alloy plates are more effective than CP-Ti plates in promoting bone healing by reducing stress shielding and enhancing IFM. The lower Young's modulus of TiNbSn allows better load distribution, facilitating bone regeneration and strengthening at the fracture site.
Collapse
Affiliation(s)
- Tomoki Koyama
- Department of Orthopaedic Surgery, Tohoku University Graduate School of Medicine, Sendai, 980-8574, Japan.
| | - Yu Mori
- Department of Orthopaedic Surgery, Tohoku University Graduate School of Medicine, Sendai, 980-8574, Japan.
| | - Masayuki Kamimura
- Department of Orthopaedic Surgery, Tohoku University Graduate School of Medicine, Sendai, 980-8574, Japan.
| | - Hidetatsu Tanaka
- Department of Orthopaedic Surgery, Tohoku University Graduate School of Medicine, Sendai, 980-8574, Japan.
| | - Rui Tome
- Mechanical Engineering Program, Faculty of Engineering, Niigata University, Niigata, 950-2181, Japan.
| | - Ketaro Ito
- Department of Orthopaedic Surgery, Tohoku University Graduate School of Medicine, Sendai, 980-8574, Japan.
| | - Masashi Koguchi
- Department of Orthopaedic Surgery, Tohoku University Graduate School of Medicine, Sendai, 980-8574, Japan.
| | - Naoko Mori
- Department of Radiology, Akita University Graduate School of Medicine, Akita, 010-8543, Japan.
| | - Toshimi Aizawa
- Department of Orthopaedic Surgery, Tohoku University Graduate School of Medicine, Sendai, 980-8574, Japan.
| |
Collapse
|
4
|
Ceddia M, Solarino G, Dramisino P, De Giosa G, Rizzo S, Trentadue B. Comparison of Stress between Three Different Functionally Graded Hip Stem Implants Made of Different Titanium Alloys and Composite Materials. JOURNAL OF COMPOSITES SCIENCE 2024; 8:449. [DOI: 10.3390/jcs8110449] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/23/2025]
Abstract
This study aims to evaluate the mechanical behavior, by ways of the FEM, of three femoral stems made of a Ti-6Al-4V titanium alloy with transverse holes in the proximal zone and a stem made of a β-type titanium alloy with a stiffness varying from 65 GPa in the proximal zone to 110 GPa in the distal zone and the CFRP composite material. The purpose of the study was to evaluate the effect of stress shielding on an intact femoral bone. A three-dimensional model of the intact femur was created, and the three prostheses were inserted with perfect stem bone fit. Applying constraint conditions such as fixation in all directions of the distal part of the femur and the application of a static load simulating standing still during a gait cycle allowed the stresses of both the implants and the bone to be compared. Evaluating the stress shielding for the three proposed materials was possible by identifying the seven Gruen zones. We can see from the results obtained that the metal alloys produced observable stress shielding in all the Gruen zones. There was a difference for the β-type alloy which, as a result of its stiffness variation from the proximal to the distal zone, did not show any level of stress shielding in Gruen zones 1 and 2. The CFRP composite, in contrast, showed no stress shielding in all of the Gruen zones and is an excellent material for the fabrication of total hip replacements. Further in vitro and in vivo validation studies are needed to make the modeling more accurate and understand the biological effects of the use of the three materials.
Collapse
Affiliation(s)
- Mario Ceddia
- Department of Mechanics, Mathematics and Management, Polytechnic of Bari, 70125 Bari, Italy
| | - Giuseppe Solarino
- Department of Translational Biomedicine and Neuroscience, University of Bari “Aldo Moro”, Policlinic Piazza G. Cesare, 11, 70124 Bari, Italy
| | - Pasquale Dramisino
- Department of Translational Biomedicine and Neuroscience, University of Bari “Aldo Moro”, Policlinic Piazza G. Cesare, 11, 70124 Bari, Italy
| | - Giuseppe De Giosa
- Department of Translational Biomedicine and Neuroscience, University of Bari “Aldo Moro”, Policlinic Piazza G. Cesare, 11, 70124 Bari, Italy
| | - Stefano Rizzo
- Department of Translational Biomedicine and Neuroscience, University of Bari “Aldo Moro”, Policlinic Piazza G. Cesare, 11, 70124 Bari, Italy
| | - Bartolomeo Trentadue
- Department of Mechanics, Mathematics and Management, Polytechnic of Bari, 70125 Bari, Italy
| |
Collapse
|
5
|
Jia T, Guines D, Gordin DM, Leotoing L, Gloriant T. Finite element analysis of a low modulus Ti-20Zr-3Mo-3Sn alloy designed to reduce the stress shielding effect of a hip prosthesis. J Mech Behav Biomed Mater 2024; 157:106640. [PMID: 38917558 DOI: 10.1016/j.jmbbm.2024.106640] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2024] [Revised: 06/17/2024] [Accepted: 06/19/2024] [Indexed: 06/27/2024]
Abstract
After total hip arthroplasty, the stress shielding effect can occur due to the difference of stiffness between the metallic alloy of the stems and the host bone, which may cause a proximal bone loss. To overcome this problem, a low-modulus metastable β Ti-20Zr-3Mo-3Sn alloy composition has recently been designed to be potentially used for the cementless femoral hip stems. After having verified experimentally that the β alloy has a low modulus of around 50 GPa, a finite element analysis was performed on a Ti-20Zr-3Mo-3Sn alloy hip prosthesis model to evaluate the influence of a reduced modulus on stress shielding and stress fields in both stem and bone compared with the medical grade Ti-6Al-4V alloy whose elastic modulus reached 110 GPa. Our results show that the Ti-20Zr-3Mo-3Sn stem with low elastic modulus can effectively reduce the total stress shielding by 45.5% compared to the common Ti-6Al-4V prosthesis. Moreover, it is highlighted that the material elasticity affects the stress distribution in the implant, especially near the bone-stem interfaces.
Collapse
Affiliation(s)
- Tianyu Jia
- University of Rennes, INSA Rennes, CNRS UMR 6226 ISCR, 35000, Rennes, France
| | - Dominique Guines
- University of Rennes, INSA Rennes, LGCGM, EA 3913, 35000, Rennes, France
| | | | - Lionel Leotoing
- University of Rennes, INSA Rennes, LGCGM, EA 3913, 35000, Rennes, France
| | - Thierry Gloriant
- University of Rennes, INSA Rennes, CNRS UMR 6226 ISCR, 35000, Rennes, France.
| |
Collapse
|
6
|
Sunavala-Dossabhoy G, Saba BM, McCarthy KJ. Debulking of the Femoral Stem in a Primary Total Hip Joint Replacement: A Novel Method to Reduce Stress Shielding. Bioengineering (Basel) 2024; 11:393. [PMID: 38671814 PMCID: PMC11047840 DOI: 10.3390/bioengineering11040393] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2024] [Revised: 04/12/2024] [Accepted: 04/15/2024] [Indexed: 04/28/2024] Open
Abstract
In current-generation designs of total primary hip joint replacement, the prostheses are fabricated from alloys. The modulus of elasticity of the alloy is substantially higher than that of the surrounding bone. This discrepancy plays a role in a phenomenon known as stress shielding, in which the bone bears a reduced proportion of the applied load. Stress shielding has been implicated in aseptic loosening of the implant which, in turn, results in reduction in the in vivo life of the implant. Rigid implants shield surrounding bone from mechanical loading, and the reduction in skeletal stress necessary to maintain bone mass and density results in accelerated bone loss, the forerunner to implant loosening. Femoral stems of various geometries and surface modifications, materials and material distributions, and porous structures have been investigated to achieve mechanical properties of stems closer to those of bone to mitigate stress shielding. For improved load transfer from implant to femur, the proposed study investigated a strategic debulking effort to impart controlled flexibility while retaining sufficient strength and endurance properties. Using an iterative design process, debulked configurations based on an internal skeletal truss framework were evaluated using finite element analysis. The implant models analyzed were solid; hollow, with a proximal hollowed stem; FB-2A, with thin, curved trusses extending from the central spine; and FB-3B and FB-3C, with thick, flat trusses extending from the central spine in a balanced-truss and a hemi-truss configuration, respectively. As outlined in the International Organization for Standardization (ISO) 7206 standards, implants were offset in natural femur for evaluation of load distribution or potted in testing cylinders for fatigue testing. The commonality across all debulked designs was the minimization of proximal stress shielding compared to conventional solid implants. Stem topography can influence performance, and the truss implants with or without the calcar collar were evaluated. Load sharing was equally effective irrespective of the collar; however, the collar was critical to reducing the stresses in the implant. Whether bonded directly to bone or cemented in the femur, the truss stem was effective at limiting stress shielding. However, a localized increase in maximum principal stress at the proximal lateral junction could adversely affect cement integrity. The controlled accommodation of deformation of the implant wall contributes to the load sharing capability of the truss implant, and for a superior biomechanical performance, the collared stem should be implanted in interference fit. Considering the results of all implant designs, the truss implant model FB-3C was the best model.
Collapse
Affiliation(s)
- Gulshan Sunavala-Dossabhoy
- Department of Biochemistry and Molecular Biology, LSU Health Science Center in Shreveport and Feist Weiller Cancer Center, Shreveport, LA 71130, USA
| | - Brent M. Saba
- Saba Metallurgical and Plant Engineering Services, LLC, Madisonville, LA 70447, USA;
| | - Kevin J. McCarthy
- Department of Cellular Biology and Anatomy, LSU Health Science Center in Shreveport and Feist Weiller Cancer Center, Shreveport, LA 71130, USA;
| |
Collapse
|
7
|
Koguchi M, Mori Y, Kamimura M, Ito K, Tanaka H, Kurishima H, Koyama T, Mori N, Masahashi N, Aizawa T. Low Young's Modulus TiNbSn Alloy Locking Plates Accelerate Osteosynthesis in Rabbit Tibiae. TOHOKU J EXP MED 2023; 261:199-209. [PMID: 37704419 DOI: 10.1620/tjem.2023.j075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/15/2023]
Abstract
A new beta TiNbSn alloy with a low Young's modulus of approximately 40 GPa has been developed to resolve the stress shielding by Young's modulus divergence. In this study, the efficacy of TiNbSn alloy locking plates on bone repair is compared to that of commercially pure titanium (CP-Ti). The TiNbSn alloy and CP-Ti, which have Young's moduli of 49.1 GPa and 107 GPa, respectively, were compared. Male Japanese white rabbits were anesthetized, and osteotomy and osteosynthesis with locking plates were performed on the right tibia. The bone repair was assessed using micro-computed tomography (CT), histomorphometry, immunohistochemistry, and mechanical testing. Micro-CT, histomorphometry, immunohistochemistry, and mechanical testing were performed four weeks after osteotomy. Six weeks after surgery, micro-CT and mechanical testing were performed. Micro-CT analysis at four weeks after surgery showed that the intramedullary fracture callus in the TiNbSn alloy group had more bone volume and numerous bridging structures compared to the CP-Ti group (CP-Ti vs. TiNbSn alloy, 34.3 ± 13.1 mm3 vs. 61.3 ± 19.6 mm3, p = 0.02; mean ± standard deviation). At four weeks post-osteotomy, the healed tibia showed significantly higher strength in the TiNbSn alloy group compared with CP-Ti (CP-Ti vs. TiNbSn alloy, 81.3 ± 31.2 N vs. 133.7 ± 46.6 N, p = 0.04). TiNbSn alloy locking plates had a more positive impact on bone formation and bone strength restoration than the CP-Ti locking plates during the early phase of bone healing.
Collapse
Affiliation(s)
- Masashi Koguchi
- Department of Orthopaedic Surgery, Tohoku University Graduate School of Medicine
| | - Yu Mori
- Department of Orthopaedic Surgery, Tohoku University Graduate School of Medicine
| | - Masayuki Kamimura
- Department of Orthopaedic Surgery, Tohoku University Graduate School of Medicine
| | - Kentaro Ito
- Department of Orthopaedic Surgery, Tohoku University Graduate School of Medicine
| | - Hidetatsu Tanaka
- Department of Orthopaedic Surgery, Tohoku University Graduate School of Medicine
| | - Hiroaki Kurishima
- Department of Orthopaedic Surgery, Tohoku University Graduate School of Medicine
| | - Tomoki Koyama
- Department of Orthopaedic Surgery, Tohoku University Graduate School of Medicine
| | - Naoko Mori
- Department of Radiology, Akita University Graduate School of Medicine
| | | | - Toshimi Aizawa
- Department of Orthopaedic Surgery, Tohoku University Graduate School of Medicine
| |
Collapse
|
8
|
Soliman MM, Islam MT, Chowdhury MEH, Alqahtani A, Musharavati F, Alam T, Alshammari AS, Misran N, Soliman MS, Mahmud S, Khandakar A. Advancement in total hip implant: a comprehensive review of mechanics and performance parameters across diverse novelties. J Mater Chem B 2023; 11:10507-10537. [PMID: 37873807 DOI: 10.1039/d3tb01469j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2023]
Abstract
The UK's National Joint Registry (NJR) and the American Joint Replacement Registry (AJRR) of 2022 revealed that total hip replacement (THR) is the most common orthopaedic joint procedure. The NJR also noted that 10-20% of hip implants require revision within 1 to 10 years. Most of these revisions are a result of aseptic loosening, dislocation, implant wear, implant fracture, and joint incompatibility, which are all caused by implant geometry disparity. The primary purpose of this review article is to analyze and evaluate the mechanics and performance factors of advancement in hip implants with novel geometries. The existing hip implants can be categorized based on two parts: the hip stem and the joint of the implant. Insufficient stress distribution from implants to the femur can cause stress shielding, bone loss, excessive micromotion, and ultimately, implant aseptic loosening due to inflammation. Researchers are designing hip implants with a porous lattice and functionally graded material (FGM) stems, femur resurfacing, short-stem, and collared stems, all aimed at achieving uniform stress distribution and promoting adequate bone remodeling. Designing hip implants with a porous lattice FGM structure requires maintaining stiffness, strength, isotropy, and bone development potential. Mechanical stability is still an issue with hip implants, femur resurfacing, collared stems, and short stems. Hip implants are being developed with a variety of joint geometries to decrease wear, improve an angular range of motion, and strengthen mechanical stability at the joint interface. Dual mobility and reverse femoral head-liner hip implants reduce the hip joint's dislocation limits. In addition, researchers reveal that femoral headliner joints with unidirectional motion have a lower wear rate than traditional ball-and-socket joints. Based on research findings and gaps, a hypothesis is formulated by the authors proposing a hip implant with a collared stem and porous lattice FGM structure to address stress shielding and micromotion issues. A hypothesis is also formulated by the authors suggesting that the utilization of a spiral or gear-shaped thread with a matched contact point at the tapered joint of a hip implant could be a viable option for reducing wear and enhancing stability. The literature analysis underscores substantial research opportunities in developing a hip implant joint that addresses both dislocation and increased wear rates. Finally, this review explores potential solutions to existing obstacles in developing a better hip implant system.
Collapse
Affiliation(s)
- Md Mohiuddin Soliman
- Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering & Built Environment, Universiti Kebangsaan Malaysia (UKM), Bangi 43600, Malaysia.
| | - Mohammad Tariqul Islam
- Centre for Advanced Electronic and Communication Engineering, Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering & Built Environment, Universiti Kebangsaan Malaysia (UKM), Bangi 43600, Malaysia.
| | - Muhammad E H Chowdhury
- Department of Electrical Engineering, College of Engineering, Qatar University, Doha 2713, Qatar.
| | - Abdulrahman Alqahtani
- Department of Medical Equipment Technology, College of Applied, Medical Science, Majmaah University, Majmaah City 11952, Saudi Arabia
- Department of Biomedical Technology, College of Applied Medical Sciences in Al-Kharj, Prince Sattam Bin Abdulaziz University, Al-Kharj 11942, Saudi Arabia.
| | - Farayi Musharavati
- Department of Mechanical & Industrial Engineering, Qatar University, Doha 2713, Qatar.
| | - Touhidul Alam
- Pusat Sains Ankasa (ANGKASA), Institut Perubahan Iklim, Universiti Kebangsaan Malaysia (UKM), Bangi 43600, Selangor, Malaysia.
| | - Ahmed S Alshammari
- Department of Electrical Engineering, College of Engineering, University Hail, Hail 81481, Saudi Arabia.
- Department of Electrical Engineering, College of Engineering, Taif University, P.O. Box 11099, Taif 21944, Saudi Arabia.
| | - Norbahiah Misran
- Centre for Advanced Electronic and Communication Engineering, Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering & Built Environment, Universiti Kebangsaan Malaysia (UKM), Bangi 43600, Malaysia.
| | - Mohamed S Soliman
- Department of Electrical Engineering, College of Engineering, Taif University, P.O. Box 11099, Taif 21944, Saudi Arabia.
- Department of Electrical Engineering, Faculty of Energy Engineering, Aswan University, Aswan, 81528, Egypt
| | - Sakib Mahmud
- Department of Electrical Engineering, College of Engineering, Qatar University, Doha 2713, Qatar.
| | - Amith Khandakar
- Department of Electrical Engineering, College of Engineering, Qatar University, Doha 2713, Qatar.
| |
Collapse
|
9
|
Baba K, Mori Y, Chiba D, Kuwahara Y, Kurishima H, Tanaka H, Kogure A, Kamimura M, Yamada N, Ohtsu S, Oyama M, Masahashi N, Hanada S, Itoi E, Aizawa T. TiNbSn stems with gradient changes of Young's modulus and stiffness reduce stress shielding compared to the standard fit-and-fill stems. Eur J Med Res 2023; 28:214. [PMID: 37400903 DOI: 10.1186/s40001-023-01199-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Accepted: 06/26/2023] [Indexed: 07/05/2023] Open
Abstract
BACKGROUND The difference between Young's moduli of the femur and the stem causes stress shielding (SS). TiNbSn (TNS) stem has a low Young's modulus and strength with gradient functional properties during the change in elastic modulus with heat treatment. The aim of this study was to investigate the inhibitory effect of TNS stems on SS and their clinical outcomes compared to conventional stems. METHODS This study was a clinical trial. Primary THA was performed using a TNS stem from April 2016 to September 2017 for patients in the TNS group. Unilateral THA was performed using a Ti6Al4V alloy stem from January 2007 to February 2011 for patients in the control group. The TNS and Ti6Al4V stems were matched in shape. Radiographs were obtained at the 1- and 3-year follow-ups. Two surgeons independently checked the SS grade and appearance of cortical hypertrophy (CH). The Japanese Orthopaedic Association (JOA) scores before and 1 year after surgery were assessed as clinical scores. RESULTS None of the patients in the TNS group had grade 3 or 4 SS. In contrast, in the control group, 24% and 40% of patients had grade 3 and 4 SS at the 1- and 3-year follow-ups, respectively. The SS grade was lower in the TNS group than in the control group at the 1- and 3-year follow-ups (p < 0.001). The frequencies of CH in both groups were no significant difference at the 1- and 3-year follow-ups. The JOA scores of the TNS group significantly improved at 1 year after surgery and were comparable to control group. CONCLUSION The TNS stem reduced SS at 1 and 3 years after THA compared to the proximal-engaging cementless stem, although the shapes of the stems matched. The TNS stem could reduce SS, stem loosening, and periprosthetic fractures. TRIAL REGISTRATION Current Controlled Trials. ISRCTN21241251. https://www.isrctn.com/search?q=21241251 . The date of registration was October 26, 2021. Retrospectively registered.
Collapse
Affiliation(s)
- Kazuyoshi Baba
- Department of Orthopaedic Surgery, Tohoku University School of Medicine, 1-1 Seiryo-Machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| | - Yu Mori
- Department of Orthopaedic Surgery, Tohoku University School of Medicine, 1-1 Seiryo-Machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan.
| | - Daisuke Chiba
- Department of Orthopaedic Surgery, Tohoku University School of Medicine, 1-1 Seiryo-Machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| | - Yoshiyuki Kuwahara
- Department of Orthopaedic Surgery, Tohoku University School of Medicine, 1-1 Seiryo-Machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| | - Hiroaki Kurishima
- Department of Orthopaedic Surgery, Tohoku University School of Medicine, 1-1 Seiryo-Machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| | - Hidetatsu Tanaka
- Department of Orthopaedic Surgery, Tohoku University School of Medicine, 1-1 Seiryo-Machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| | - Atsushi Kogure
- Department of Orthopaedic Surgery, Tohoku University School of Medicine, 1-1 Seiryo-Machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| | - Masayuki Kamimura
- Department of Orthopaedic Surgery, Tohoku University School of Medicine, 1-1 Seiryo-Machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| | - Norikazu Yamada
- Department of Orthopaedic Surgery, Sendai Red Cross Hospital, 2‑43‑3 Yagiyamahoncho, Taihaku‑ku, Sendai, Miyagi, 982-8501, Japan
| | - Susumu Ohtsu
- Department of Orthopaedic Surgery, Osaki Citizen Hospital, 3-8-1 Furukawahonami, Osaki, Miyagi, 989-6183, Japan
| | - Masamizu Oyama
- Department of Orthopaedic Surgery, Sendai Red Cross Hospital, 2‑43‑3 Yagiyamahoncho, Taihaku‑ku, Sendai, Miyagi, 982-8501, Japan
| | - Naoya Masahashi
- Institute for Materials Research, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai, Miyagi, 980-8577, Japan
| | - Shuji Hanada
- Institute for Materials Research, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai, Miyagi, 980-8577, Japan
| | - Eiji Itoi
- Department of Orthopaedic Surgery, Tohoku Rosai Hospital, 4-3-21 Dainohara, Aoba-ku, Sendai, Miyagi, 981-0911, Japan
| | - Toshimi Aizawa
- Department of Orthopaedic Surgery, Tohoku University School of Medicine, 1-1 Seiryo-Machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| |
Collapse
|
10
|
Johnston A, Callanan A. Recent Methods for Modifying Mechanical Properties of Tissue-Engineered Scaffolds for Clinical Applications. Biomimetics (Basel) 2023; 8:205. [PMID: 37218791 PMCID: PMC10204517 DOI: 10.3390/biomimetics8020205] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Revised: 05/03/2023] [Accepted: 05/12/2023] [Indexed: 05/24/2023] Open
Abstract
The limited regenerative capacity of the human body, in conjunction with a shortage of healthy autologous tissue, has created an urgent need for alternative grafting materials. A potential solution is a tissue-engineered graft, a construct which supports and integrates with host tissue. One of the key challenges in fabricating a tissue-engineered graft is achieving mechanical compatibility with the graft site; a disparity in these properties can shape the behaviour of the surrounding native tissue, contributing to the likelihood of graft failure. The purpose of this review is to examine the means by which researchers have altered the mechanical properties of tissue-engineered constructs via hybrid material usage, multi-layer scaffold designs, and surface modifications. A subset of these studies which has investigated the function of their constructs in vivo is also presented, followed by an examination of various tissue-engineered designs which have been clinically translated.
Collapse
Affiliation(s)
| | - Anthony Callanan
- Institute for Bioengineering, School of Engineering, University of Edinburgh, Edinburgh EH9 3DW, UK;
| |
Collapse
|
11
|
Mechanical properties and biocompatibility of a novel miniscrew made of Zr 70Ni 16Cu 6Al 8 bulk metallic glass for orthodontic anchorage. Sci Rep 2023; 13:3038. [PMID: 36810765 PMCID: PMC9943840 DOI: 10.1038/s41598-023-30102-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Accepted: 02/15/2023] [Indexed: 02/23/2023] Open
Abstract
The purpose of the present study was to fabricate a miniscrew possible for clinical application using Zr70Ni16Cu6Al8 bulk metallic glass (BMG), which has high mechanical strength, low elastic modulus, and high biocompatibility. First, the elastic moduli of Zr-based metallic glass rods made of Zr55Ni5Cu30Al10, Zr60Ni10Cu20Al10, Zr65Ni10Cu17.5Al7.5, Zr68Ni12Cu12Al8, and Zr70Ni16Cu6Al8 were measured. Zr70Ni16Cu6Al8 had the lowest elastic modulus among them. Then, we fabricated Zr70Ni16Cu6Al8 BMG miniscrews with diameters from 0.9 to 1.3 mm, conducted a torsion test, and implanted them into the alveolar bone of beagle dogs to compare insertion torque, removal torque, Periotest, new bone formation around the miniscrew, and failure rate compared with 1.3 mm diameter Ti-6Al-4 V miniscrew. The Zr70Ni16Cu6Al8 BMG miniscrew exhibited a high torsion torque even if the miniscrew had a small diameter. Zr70Ni16Cu6Al8 BMG miniscrews with a diameter of 1.1 mm or less had higher stability and lower failure rate than 1.3 mm diameter Ti-6Al-4 V miniscrews. Furthermore, the smaller diameter Zr70Ni16Cu6Al8 BMG miniscrew was shown, for the first time, to have a higher success rate and to form more new bone around the miniscrew. These findings suggested the usefulness of our novel small miniscrew made of Zr70Ni16Cu6Al8 BMG for orthodontic anchorage.
Collapse
|
12
|
Vio War AS, Kumar N, Chanda S. Does preclinical analysis based on static loading underestimate post-surgery stem micromotion in THA as opposed to dynamic gait loading? Med Biol Eng Comput 2023; 61:1473-1488. [PMID: 36763232 DOI: 10.1007/s11517-023-02801-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Accepted: 01/31/2023] [Indexed: 02/11/2023]
Abstract
The success of cementless hip stems depends on the primary stability of the implant quantified by the amount of micromotion at the bone-stem interface. Most finite element (FE)-based preclinical studies on post-surgery stem stability rely on static analysis. Hence, the effect of dynamic gait loading on bone-stem relative micromotion remains virtually unexplored. Furthermore, there is a paucity of research on the primary stability of grooved stems as opposed to plain stem design. The primary aim of this FE study was to understand whether transient dynamic gait had any incremental effect on the net micromotion results and to further draw insights into the effects of grooved texture vis-à-vis a plain model on micromotion and proximal load transfer in host bone. Two musculoskeletal loading regimes corresponding to normal walking (NW) and stair climbing (SC) were considered. Although marginally improved load transfer was predicted proximally for the grooved construct under static loading, the micromotion values (max: NW ~ 7 μm; SC ~ 10 μm) were found to be considerably less in comparison to plain stem (max: NW ~ 50 μm; SC ~ 20 μm). For both physiological load cases, a significant surge in micromotion values was predicted in dynamic analyses as opposed to static analyses for the grooved stem (~ 390% greater). For the plain model, the increase in these values from static to dynamic loading is relatively moderate yet clinically significant (~ 230% greater). This suggests that the qualitative similarities notwithstanding, there were significant dissimilarities in the quantitative trends of micromotion for different cases under both analyses.
Collapse
Affiliation(s)
- Adeline S Vio War
- Department of Biosciences and Bioengineering, Indian Institute of Technology Guwahati, Guwahati, 781 039, Assam, India
| | - Neeraj Kumar
- Department of Biosciences and Bioengineering, Indian Institute of Technology Guwahati, Guwahati, 781 039, Assam, India
| | - Souptick Chanda
- Department of Biosciences and Bioengineering, Indian Institute of Technology Guwahati, Guwahati, 781 039, Assam, India.
| |
Collapse
|
13
|
Carobolante JPA, Pereira Júnior A, Bortolini Junior C, Barboza da Silva K, Sabino RM, Popat KC, Claro APRA. Processing and Characterization of a New Quaternary Alloy Ti 10Mo 8Nb 6Zr for Potential Biomedical Applications. MATERIALS (BASEL, SWITZERLAND) 2022; 15:ma15238636. [PMID: 36500131 PMCID: PMC9737621 DOI: 10.3390/ma15238636] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Revised: 11/25/2022] [Accepted: 11/27/2022] [Indexed: 05/14/2023]
Abstract
The study of new metallic biomaterials for application in bone tissue repair has improved due to the increase in life expectancy and the aging of the world population. Titanium alloys are one of the main groups of biomaterials for these applications, and beta-type titanium alloys are more suitable for long-term bone implants. The objective of this work was to process and characterize a new Ti10Mo8Nb6Zr beta alloy. Alloy processing involves arc melting, heat treatment, and cold forging. The characterization techniques used in this study were X-ray fluorescence spectroscopy, X-ray diffraction, differential scanning calorimetry, optical microscopy, microhardness measurements, and pulse excitation technique. In vitro studies using adipose-derived stem cells (ADSC) were performed to evaluate the cytotoxicity and cell viability after 1, 4, and 7 days. The results showed that the main phase during the processing route was the beta phase. At the end of processing, the alloy showed beta phase, equiaxed grains with an average size of 228.7 µm, and low Young's modulus (83 GPa). In vitro studies revealed non-cytotoxicity and superior cell viability compared to CP Ti. The addition of zirconium led to a decrease in the beta-transus temperature and Young's modulus and improved the biocompatibility of the alloy. Therefore, the Ti10Mo8Nb6Zr alloy is a promising candidate for application in the biomedical field.
Collapse
Affiliation(s)
- João Pedro Aquiles Carobolante
- School of Engineering and Sciences, Guaratinguetá Campus, São Paulo State University (Unesp), Guaratinguetá 12516-410, Brazil
| | - Adelvam Pereira Júnior
- School of Engineering and Sciences, Guaratinguetá Campus, São Paulo State University (Unesp), Guaratinguetá 12516-410, Brazil
| | - Celso Bortolini Junior
- School of Engineering and Sciences, Guaratinguetá Campus, São Paulo State University (Unesp), Guaratinguetá 12516-410, Brazil
| | - Kerolene Barboza da Silva
- School of Engineering and Sciences, Guaratinguetá Campus, São Paulo State University (Unesp), Guaratinguetá 12516-410, Brazil
| | - Roberta Maia Sabino
- School of Advanced Materials Discovery, Colorado State University, Fort Collins, CO 80523, USA
| | - Ketul C. Popat
- School of Advanced Materials Discovery, Colorado State University, Fort Collins, CO 80523, USA
- Department of Mechanical Engineering, Colorado State University, Fort Collins, CO 80523, USA
- School of Biomedical Engineering, Colorado State University, Fort Collins, CO 80523, USA
| | - Ana Paula Rosifini Alves Claro
- School of Engineering and Sciences, Guaratinguetá Campus, São Paulo State University (Unesp), Guaratinguetá 12516-410, Brazil
- Correspondence:
| |
Collapse
|
14
|
A Review of Biomaterials and Associated Performance Metrics Analysis in Pre-Clinical Finite Element Model and in Implementation Stages for Total Hip Implant System. Polymers (Basel) 2022; 14:polym14204308. [PMID: 36297885 PMCID: PMC9607025 DOI: 10.3390/polym14204308] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Revised: 10/01/2022] [Accepted: 10/06/2022] [Indexed: 11/30/2022] Open
Abstract
Total hip replacement (THR) is a common orthopedic surgery technique that helps thousands of individuals to live normal lives each year. A hip replacement replaces the shattered cartilage and bone with an implant. Most hip implants fail after 10–15 years. The material selection for the total hip implant systems is a major research field since it affects the mechanical and clinical performance of it. Stress shielding due to excessive contact stress, implant dislocation due to a large deformation, aseptic implant loosening due to the particle propagation of wear debris, decreased bone remodeling density due to the stress shielding, and adverse tissue responses due to material wear debris all contribute to the failure of hip implants. Recent research shows that pre-clinical computational finite element analysis (FEA) can be used to estimate four mechanical performance parameters of hip implants which are connected with distinct biomaterials: von Mises stress and deformation, micromotion, wear estimates, and implant fatigue. In vitro, in vivo, and clinical stages are utilized to determine the hip implant biocompatibility and the unfavorable local tissue reactions to different biomaterials during the implementation phase. This research summarizes and analyses the performance of the different biomaterials that are employed in total hip implant systems in the pre-clinical stage using FEA, as well as their performances in in vitro, in vivo, and in clinical studies, which will help researchers in gaining a better understanding of the prospects and challenges in this field.
Collapse
|
15
|
Mechanical micromodeling of stress-shielding at the bone-implant interphase under shear loading. Med Biol Eng Comput 2022; 60:3281-3293. [DOI: 10.1007/s11517-022-02657-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Accepted: 08/22/2022] [Indexed: 10/14/2022]
|
16
|
Fujii T, Murakami R, Kobayashi N, Tohgo K, Shimamura Y. Uniform porous and functionally graded porous titanium fabricated via space holder technique with spark plasma sintering for biomedical applications. ADV POWDER TECHNOL 2022. [DOI: 10.1016/j.apt.2022.103598] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|
17
|
Improved Tribocorrosion Behavior Obtained by In-Situ Precipitation of Ti2C in Ti-Nb Alloy. METALS 2022. [DOI: 10.3390/met12060908] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Novel in-situ Ti-based matrix composites (TMCs) were developed through the reactive hot pressing of Ti + NbC powder blends. Due to the chemical reaction that occurred in the solid-state during processing, the produced samples were composed of an Nb-rich β-Ti phase that formed a metallic matrix along with Ti2C as a reinforcing phase. By employing different proportions of Ti:NbC, the phase composition of the alloys was designed to contain different ratios of α-Ti and β-Ti. The present work investigated the corrosion and tribocorrosion behavior of the composites, compared to unreinforced Ti, in a phosphate-buffered solution (PBS) at body temperature. Corrosion tests included potentiodynamic polarization and electrochemical impedance spectroscopy (EIS). Tribocorrosion tests were carried out using a ball-on-plate tribometer with sliding performed at open circuit potential (OCP) and under anodic potentiostatic conditions. Results showed that the stabilization of the β phase in the matrix led to a decrease in the hardness. However, the formation of the in-situ reinforcing phase significantly improved the tribocorrosion behavior of the composites due to a load-carrying effect, lowering the corrosion tendency and kinetics under sliding. Furthermore, localized corrosion was not observed at the interface between the reinforcing phase and the matrix.
Collapse
|
18
|
Self-organized TiO2 nanotubes on Ti-Nb-Fe alloys for biomedical applications: Synthesis and characterization. Electrochem commun 2022. [DOI: 10.1016/j.elecom.2022.107280] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
|
19
|
Abstract
Total hip arthroplasty is one of the most common and successful orthopedic surgeries. Sometimes, periprosthetic osteolysis occurs associated with the stress-shielding effect: it results in the reduction of bone density, where the femur is not correctly loaded, and in the formation of denser bone, where stresses are confined. This paper illustrates the stress shielding effect as a cause of the failing replacement of the hip joint. An extensive literature survey has been accomplished to describe the phenomenon and identify solutions. The latter refer to the design criteria and the choice of innovative materials/treatments for prosthetic device production. Experimental studies and numerical simulations have been reviewed. The paper includes an introduction to explain the scope; a section illustrating the causes of the stress shielding effect; a section focusing on recent attempts to redefine prosthetic device design criteria, current strategies to improve the osteointegration process, and a number of innovative biomaterials; functionally graded materials are presented in a dedicated section: they allow customizing prosthesis features with respect to the host bone. Conclusions recommend an integrated approach for the production of new prosthetic devices: the “engineering community” has to support the “medical community” to assure an effective translation of research results into clinical practice.
Collapse
|
20
|
Wang N, Meenashisundaram GK, Chang S, Fuh JYH, Dheen ST, Senthil Kumar A. A comparative investigation on the mechanical properties and cytotoxicity of Cubic, Octet, and TPMS gyroid structures fabricated by selective laser melting of stainless steel 316L. J Mech Behav Biomed Mater 2022; 129:105151. [DOI: 10.1016/j.jmbbm.2022.105151] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Revised: 12/08/2021] [Accepted: 02/27/2022] [Indexed: 01/10/2023]
|
21
|
He S, Zhao Y, Wang L, Bao Y, Xu R. Finite element analysis of optimal design of distal geometry of cementless femoral prosthesis. Niger J Clin Pract 2022; 25:1476-1483. [DOI: 10.4103/njcp.njcp_1888_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|
22
|
Chatzigeorgiou C, Piotrowski B, Chemisky Y, Laheurte P, Meraghni F. Numerical investigation of the effective mechanical properties and local stress distributions of TPMS-based and strut-based lattices for biomedical applications. J Mech Behav Biomed Mater 2021; 126:105025. [PMID: 34920324 DOI: 10.1016/j.jmbbm.2021.105025] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Revised: 10/15/2021] [Accepted: 12/02/2021] [Indexed: 12/22/2022]
Abstract
Porous structures, including those with lattice geometries, have been shown to mimic the mechanical properties of the human bone. Apart from the widely known strut-based lattices, the Triply Periodic Minimal Surfaces (TPMS) concept has been introduced recently to create surface-based lattices and to tailor their mechanical behaviors. In this study, the numerical investigation of the effective elastic properties, the anisotropic behavior, and the local stress distributions of a broad range of topologies provide us with a complete numerical tool to assist bone implant design. The comparison database of the lattices includes TPMS-based lattices, both sheet, and skeletal, as well as strut-based lattices. The lattices are subjected to periodic boundary conditions and also, a homogenization method is deployed to simulate the response of the lattice unit cells determining their apparent equivalent stiffness. A correlation among the lattice topologies, their effective mechanical properties, and the local Von Mises stress concentrations in them is observed. The stress distribution of various topologies with the same elastic modulus is examined to combine all the investigations. Finally, a large variety of numerical results are presented to allow the comparison of the lattice structures and the selection of the optimal configuration that mimics the elastic properties of the bone.
Collapse
Affiliation(s)
- Chrysoula Chatzigeorgiou
- Arts et Métiers Institute of Technology, CNRS, Université de Lorraine, LEM3-UMR 7239 CNRS, 4 rue Augustin Fresnel, 57078, Metz, France
| | - Boris Piotrowski
- Arts et Métiers Institute of Technology, CNRS, Université de Lorraine, LEM3-UMR 7239 CNRS, 4 rue Augustin Fresnel, 57078, Metz, France
| | - Yves Chemisky
- Université de Bordeaux, I2M UMR CNRS 5295, Bordeaux, France
| | - Pascal Laheurte
- Arts et Métiers Institute of Technology, CNRS, Université de Lorraine, LEM3-UMR 7239 CNRS, 4 rue Augustin Fresnel, 57078, Metz, France
| | - Fodil Meraghni
- Arts et Métiers Institute of Technology, CNRS, Université de Lorraine, LEM3-UMR 7239 CNRS, 4 rue Augustin Fresnel, 57078, Metz, France.
| |
Collapse
|
23
|
Chiba D, Yamada N, Mori Y, Oyama M, Ohtsu S, Kuwahara Y, Baba K, Tanaka H, Aizawa T, Hanada S, Itoi E. Mid-term results of a new femoral prosthesis using Ti-Nb-Sn alloy with low Young's modulus. BMC Musculoskelet Disord 2021; 22:987. [PMID: 34836525 PMCID: PMC8620944 DOI: 10.1186/s12891-021-04879-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/19/2021] [Accepted: 11/17/2021] [Indexed: 11/24/2022] Open
Abstract
Background This study was performed to investigate the mid-term results of Ti-Nb-Sn (TNS) alloy stem with a low Young’s modulus. Methods This study was a multicenter prospective cohort study. A total of 40 primary total hip arthroplasties performed between April 2016 and September 2017 was enrolled in this study. With the unique functional gradient properties by heating treatment, the strength of the proximal portion was enhanced, while the distal portion maintained a low Young’s modulus. The surgeries were performed through the posterolateral approach using the TNS alloy stems. Radiographs were taken from immediately after surgeries until 3 years, and stress shielding and subsidence of the stems were evaluated. The incidences of the stem breakage were also assessed. Clinical assessments were performed using Japanese Orthopaedic Association (JOA) and Japanese Orthopaedic Association Hip Disease Evaluation Questionnaire (JHEQ) scores. Results Among the 40 enrolled patients, 36 patients were female and 4 were male. At 3 years after surgery, there were no radiologic signs of loosening, subsidence, or breakage of the stem. Stress shielding was observed in 26 hips (65%). Of 26 hips, 16 hips (40%) were grade 1 and 10 hips (25%) were grade 2. There was no advanced stress shielding. The JOA and JHEQ scores significantly improved compared with the preoperative scores. Conclusion The current study using a new TNS alloy femoral stem showed good clinical outcomes at 3-year follow-up. Radiologically, there was no loosening or subsidence of the stem. The mild stress shielding was observed in 65% of patients. Trial registration Current Controlled Trials ISRCTN21241251. The date of registration was October 26, 2021. Retrospectively registered.
Collapse
Affiliation(s)
- Daisuke Chiba
- Department of Orthopaedic Surgery, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| | - Norikazu Yamada
- Department of Orthopaedic Surgery, Sendai Red Cross Hospital, 2-43-3 Yagiyamahoncho, Taihaku-ku, Sendai, Miyagi, 982-8501, Japan
| | - Yu Mori
- Department of Orthopaedic Surgery, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan.
| | - Masamizu Oyama
- Department of Orthopaedic Surgery, Sendai Red Cross Hospital, 2-43-3 Yagiyamahoncho, Taihaku-ku, Sendai, Miyagi, 982-8501, Japan
| | - Susumu Ohtsu
- Department of Orthopaedic Surgery, Osaki Citizen Hospital, 3-8-1 Furukawahonami, Osaki, Miyagi, 989-6183, Japan
| | - Yoshiyuki Kuwahara
- Department of Orthopaedic Surgery, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| | - Kazuyoshi Baba
- Department of Orthopaedic Surgery, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| | - Hidetatsu Tanaka
- Department of Orthopaedic Surgery, Sendai Red Cross Hospital, 2-43-3 Yagiyamahoncho, Taihaku-ku, Sendai, Miyagi, 982-8501, Japan
| | - Toshimi Aizawa
- Department of Orthopaedic Surgery, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| | - Shuji Hanada
- Institute for Materials Research, Tohoku University, 2-1-1 Katahira, Aoba-ku, Miyagi, 980-8577, Japan
| | - Eiji Itoi
- Department of Orthopaedic Surgery, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| |
Collapse
|
24
|
Zhang Y, Chen X, Li Y, Bai T, Li C, Jiang L, Liu Y, Sun C, Zhou W. Biomimetic Inorganic Nanoparticle-Loaded Silk Fibroin-Based Coating with Enhanced Antibacterial and Osteogenic Abilities. ACS OMEGA 2021; 6:30027-30039. [PMID: 34778674 PMCID: PMC8582041 DOI: 10.1021/acsomega.1c04734] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/30/2021] [Accepted: 10/15/2021] [Indexed: 06/13/2023]
Abstract
Poor osseointegration and infection are the main reasons leading to the failure of hard tissue implants; especially, in recent years, the failure rate has been increasing every year owing to the continuously increasing conditions such as injury, trauma, diseases, or infections. Therefore, the development of a biomimetic surface coating of bone tissues with antibacterial function is an effective means to improve bone healing and inhibit bacterial infection. Mimicking the natural bone, in this study, we have designed a silk fibroin (collagen-like structure)-based coating inlaid with nanohydroxyapatite (nHA) and silver nanoparticles (AgNPs) for promoting antibacterial ability and osteogenesis, especially focusing on the bone mimetic structure for enhancing bone health. Observing the morphology and size of the composite nanoparticles by transmission electron microscope (TEM), nHA provided nucleation sites for the formation of AgNPs, forming an nHA/AgNP complex with a size of about 100-200 nm. Characterization of the nHA/Ag-loaded silk fibroin biomimetic coating showed an increased surface roughness with good density and compact performances. The silk fibroin-based coating loaded with uniformly distributed AgNPs and nHA could effectively inhibit the adhesion of Staphylococcus aureus on the surface and, at the same time, quickly kill planktonic bacteria, indicating their good antibacterial ability. In vitro cell experiments revealed that the biomimetic silk fibroin-based coating was beneficial to the adhesion, spreading, and proliferation of osteoblasts (MC3T3-E1). In addition, by characterizing LDH and ROS, it was found that the nHA/Ag complex could significantly reduce the cytotoxicity of AgNPs, and the osteoblasts on the coating surface maintained the structure intact.
Collapse
Affiliation(s)
- Yunpeng Zhang
- Heping
Hospital Affiliated to Changzhi Medical College, Changzhi 046000, Shanxi, China
| | - Xiaorong Chen
- Changzhi
Medical College, Changzhi 046000, Shanxi, China
| | - Yuan Li
- Heping
Hospital Affiliated to Changzhi Medical College, Changzhi 046000, Shanxi, China
| | - Tian Bai
- Shaanxi
Key Laboratory of Biomedical Metal Materials, Northwest Institute for Non-ferrous Metal Research, Xi’an 710016, China
| | - Chen Li
- Changzhi
Medical College, Changzhi 046000, Shanxi, China
| | - Lingyan Jiang
- Heping
Hospital Affiliated to Changzhi Medical College, Changzhi 046000, Shanxi, China
| | - Yu Liu
- Heping
Hospital Affiliated to Changzhi Medical College, Changzhi 046000, Shanxi, China
| | - Changying Sun
- Heping
Hospital Affiliated to Changzhi Medical College, Changzhi 046000, Shanxi, China
| | - Wenhao Zhou
- Shaanxi
Key Laboratory of Biomedical Metal Materials, Northwest Institute for Non-ferrous Metal Research, Xi’an 710016, China
| |
Collapse
|
25
|
Li JJ, Tian DM, Yang L, Zhang JY, Hu YC. Influence of a metaphyseal sleeve on the stress-strain state of a bone-tumor implant system in the distal femur: an experimental and finite element analysis. J Orthop Surg Res 2020; 15:589. [PMID: 33298115 PMCID: PMC7724731 DOI: 10.1186/s13018-020-02025-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/24/2020] [Accepted: 10/14/2020] [Indexed: 12/03/2022] Open
Abstract
Background Aseptic loosening of distal femoral tumor implants significantly correlates with the resection length. We designed a new “sleeve” that is specially engaged in the metaphysis at least 5 cm proximal to the knee joint line to preserve as much bone stock as possible. This study investigates the influence of a metaphyseal sleeve on the stress-strain state of a bone tumor implant system in the distal femur. Methods Cortex strains in intact and implanted femurs were predicted with finite element (FE) models. Moreover strains were experimentally measured in a cadaveric femur with and without a sleeve and stem under an axial compressive load of 1000 N. The FE models, which were validated by linear regression, were used to investigate the maximal von Mises stress and the implanted-to-intact (ITI) ratios of strain in the femur with single-legged stance loading under immediate postoperative and osseointegration conditions. Results Good agreement was noted between the experimental measurements and numerical predictions of the femoral strains (coefficient of determination (R2) ≥ 0.95; root-mean-square error (RMSE%) ≈ 10%). The ITI ratios for the metaphysis were between 13 and 28% and between 10 and 21% under the immediate postoperative and osseointegration conditions, respectively, while the ITI ratios for the posterior and lateral cortices around the tip of the stem were 110% and 119% under the immediate-postoperative condition, respectively, and 114% and 101% under the osseointegration condition, respectively. The maximal von Mises stresses for the implanted femur were 113.8 MPa and 43.41 MPa under the immediate postoperative and osseointegration conditions, which were 284% and 47% higher than those in the intact femur (29.6 MPa), respectively. Conclusions This study reveals that a metaphyseal sleeve may cause stress shielding relative to the intact femur, especially in the distal metaphysis. Stress concentrations might mainly occur in the posterior cortex around the tip of the stem. However, stress concentrations may not be accompanied by periprosthetic fracture under the single-legged stance condition.
Collapse
Affiliation(s)
- Jian-Jun Li
- Tianjin Medical University, 22 Qixiangtai Road, Tianjin, People's Republic of China.,Department of Bone Oncology, Tianjin Hospital, 406 Jiefang Southern Road, Tianjin, People's Republic of China.,Department of Bone Trauma, Second Hospital of Tangshan, 22 Jianshe North Road, Tangshan, Hebei, People's Republic of China
| | - Dong-Mu Tian
- Beijing Weigao Yahua Artificial Joint Development Company, 7 Niuhui Street, Shunyi, Beijing, People's Republic of China
| | - Li Yang
- Tianjin Medical University, 22 Qixiangtai Road, Tianjin, People's Republic of China
| | - Jing-Yu Zhang
- Department of Bone Oncology, Second Hospital of Tangshan, 22 Jianshe North Road, Tangshan, Hebei, People's Republic of China
| | - Yong-Cheng Hu
- Department of Bone Oncology, Tianjin Hospital, 406 Jiefang Southern Road, Tianjin, People's Republic of China.
| |
Collapse
|
26
|
Quinn J, McFadden R, Chan CW, Carson L. Titanium for Orthopedic Applications: An Overview of Surface Modification to Improve Biocompatibility and Prevent Bacterial Biofilm Formation. iScience 2020; 23:101745. [PMID: 33235984 PMCID: PMC7670191 DOI: 10.1016/j.isci.2020.101745] [Citation(s) in RCA: 79] [Impact Index Per Article: 15.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Titanium and its alloys have emerged as excellent candidates for use as orthopedic biomaterials. Nevertheless, there are often complications arising after implantation of orthopedic devices, most notably prosthetic joint infection and aseptic loosening. To ensure that implanted devices remain functional in situ, innovation in surface modification has attracted much attention in the effort to develop orthopedic materials with optimal characteristics at the biomaterial-tissue interface. This review will draw together metallurgy, surface engineering, biofilm microbiology, and biomaterial science. It will serve to appreciate why titanium and its alloys are frequently used orthopedic biomaterials and address some of the challenges facing these biomaterials currently, including the significant problem of device-associated infection. Finally, the authors shall consolidate and evaluate surface modification techniques employed to overcome some of these issues by offering a unique perspective as to the direction in which research is headed from a broad, interdisciplinary point of view.
Collapse
Affiliation(s)
- James Quinn
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast BT9 7BL, UK
| | - Ryan McFadden
- School of Mechanical and Aerospace Engineering, Queen's University Belfast, Ashby Building, Stranmillis Road, Belfast BT9 5AH, UK
| | - Chi-Wai Chan
- School of Mechanical and Aerospace Engineering, Queen's University Belfast, Ashby Building, Stranmillis Road, Belfast BT9 5AH, UK
| | - Louise Carson
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast BT9 7BL, UK
| |
Collapse
|
27
|
Gislason MK, Lupidio F, Jónsson H, Cristofolini L, Esposito L, Bifulco P, Fraldi M, Gargiulo P. Three dimensional bone mineral density changes in the femur over 1 year in primary total hip arthroplasty patients. Clin Biomech (Bristol, Avon) 2020; 78:105092. [PMID: 32590143 DOI: 10.1016/j.clinbiomech.2020.105092] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/16/2020] [Revised: 05/19/2020] [Accepted: 06/09/2020] [Indexed: 02/07/2023]
Abstract
BACKGROUND The aim of the study was to compare the bone mineral density changes between unmatched patients undergoing total hip arthroplasty receiving uncemented and cemented type of implants. Previous studies have used DEXA or a two dimensional analysis to estimate the bone quality following total joint replacement, whereas this study presents the changes in three dimensions. METHODS Fifty subjects both male and females receiving both cemented and uncemented type of implant were recruited. Two CT scans were taken of each subject, the first at 24 h post surgery and the second one 1 year after surgery. The scans were calibrated using a phantom converting the Hounsfield units to bone mineral density values in g/cm3. The two scans were registered together using anatomical landmarks and resliced to compare the two femurs in the identical frame of reference. The bone density gain and loss was calculated by comparing density values between the two sets of scans. FINDINGS The results showed that most of the bone loss was located around the Lesser Trochanter and some bone density gain at the distal tip of the implant. The three dimensional density changes occur differently between individuals and the study showed no correlation of bone loss with age. INTERPRETATION The bone loss occurred mostly at the proximal femur, which is in agreement with previously presented studies. By carrying out three dimensional analysis on the bone gain and loss on the femur, it is possible to identify the patients that are showing high degree of bone loss.
Collapse
Affiliation(s)
| | - Francesca Lupidio
- Institute for Biomedical and Neural Engineering, Reykjavik University, Iceland; University of Bologna, Department of Industrial Engineering, Italy
| | - Halldór Jónsson
- Landspitali University Hospital, Department of Orthopaedics, Iceland
| | | | - Luca Esposito
- University of Naples Federico II, Department of Structures for Engineering and Architecture, Italy
| | - Paolo Bifulco
- University of Naples Federico II, Department of Electrical Engineering and Information Technologies, Italy
| | - Massimiliano Fraldi
- University of Naples Federico II, Department of Structures for Engineering and Architecture, Italy
| | - Paolo Gargiulo
- Institute for Biomedical and Neural Engineering, Reykjavik University, Iceland; Department of Science, Landspitali University Hospital, Iceland
| |
Collapse
|
28
|
Zhang T, Xu H, Li Z, She H, Du D, Dong A, Xing H, Wang D, Zhu G, Sun B. Microstructure and properties of TC4/TNTZO multi-layered composite by direct laser deposition. J Mech Behav Biomed Mater 2020; 109:103842. [PMID: 32543409 DOI: 10.1016/j.jmbbm.2020.103842] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2020] [Revised: 04/17/2020] [Accepted: 04/28/2020] [Indexed: 10/24/2022]
Abstract
In this work, TC4/TNTZO multi-layered composite as well as TNTZO and TC4 alloys were prepared by direct laser deposition (DLD) to investigate the microstructure, mechanical properties and in vitro bioactivity. The microstructure characterization shows that the multi-layered material is free of cracks and intermetallics while the interface is metallurgically bonded. The fine microstructure was observed in TC4 layer of the TC4/TNTZO multi-layered material, and a large amount of α' martensite exists in the transition zone. Different from the single β phase cellular arrays in the DLD-ed TNTZO alloy, α″ martensite with high volume content formed at the cellular grain boundary in TNTZO zone of DLD-ed TC4/TNTZO. The elastic modulus of the DLD-ed TC4/TNTZO is 64 GPa, decreased about 45% compared to the DLD-ed TC4. The tensile yield strength and elongation along the printing direction are up to 789 MPa and 7%, which are 12% higher than the tensile yield strength of DLD-ed TNTZO and 61% higher than the elongation of DLD-ed TC4 respectively. Moreover, the DLD-ed TC4/TNTZO shows good in vitro bioactivity. The TC4/TNTZO multi-layered composite fabricated by DLD can be regarded as a potential candidate to integrate the advantages of the two Ti-base alloys for application in the biomedical field.
Collapse
Affiliation(s)
- Ting Zhang
- Shanghai Key Lab of Advanced High-temperature Materials and Precision Forming, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, 200240, PR China
| | - Hao Xu
- Shanghai Key Lab of Advanced High-temperature Materials and Precision Forming, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, 200240, PR China
| | - Zhongjie Li
- Shanghai Key Lab of Advanced High-temperature Materials and Precision Forming, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, 200240, PR China
| | - Huan She
- School of Mechanical Engineering, Shanghai Institute of Technology, Shanghai, 201418, PR China
| | - Dafan Du
- Shanghai Key Lab of Advanced High-temperature Materials and Precision Forming, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, 200240, PR China
| | - Anping Dong
- Shanghai Key Lab of Advanced High-temperature Materials and Precision Forming, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, 200240, PR China.
| | - Hui Xing
- Shanghai Key Lab of Advanced High-temperature Materials and Precision Forming, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, 200240, PR China.
| | - Donghong Wang
- Shanghai Key Lab of Advanced High-temperature Materials and Precision Forming, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, 200240, PR China
| | - Guoliang Zhu
- Shanghai Key Lab of Advanced High-temperature Materials and Precision Forming, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, 200240, PR China
| | - Baode Sun
- Shanghai Key Lab of Advanced High-temperature Materials and Precision Forming, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, 200240, PR China
| |
Collapse
|
29
|
Li Z, Arioka M, Liu Y, Aghvami M, Tulu S, Brunski JB, Helms JA. Effects of condensation and compressive strain on implant primary stability: A longitudinal, in vivo, multiscale study in mice. Bone Joint Res 2020; 9:60-70. [PMID: 32435456 PMCID: PMC7229305 DOI: 10.1302/2046-3758.92.bjr-2019-0161] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
Aims Surgeons and most engineers believe that bone compaction improves implant primary stability without causing undue damage to the bone itself. In this study, we developed a murine distal femoral implant model and tested this dogma. Methods Each mouse received two femoral implants, one placed into a site prepared by drilling and the other into the contralateral site prepared by drilling followed by stepwise condensation. Results Condensation significantly increased peri-implant bone density but it also produced higher strains at the interface between the bone and implant, which led to significantly more bone microdamage. Despite increased peri-implant bone density, condensation did not improve implant primary stability as measured by an in vivo lateral stability test. Ultimately, the condensed bone underwent resorption, which delayed the onset of new bone formation around the implant. Conclusion Collectively, these multiscale analyses demonstrate that condensation does not positively contribute to implant stability or to new peri-implant bone formation. Cite this article:Bone Joint Res. 2020;9(2):60–70.
Collapse
Affiliation(s)
- Zhijun Li
- Division of Plastic and Reconstructive Surgery, Department of Surgery, Stanford School of Medicine, Stanford, California, USA; Orthopedic surgeon, Department of Orthopedics, Tianjin Medical University General Hospital, Tianjin, China
| | - Masaki Arioka
- Division of Plastic and Reconstructive Surgery, Department of Surgery, Stanford School of Medicine, Stanford, California, USA; Assistant professor, Department of Clinical Pharmacology, Faculty of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Yindong Liu
- Division of Plastic and Reconstructive Surgery, Department of Surgery, Stanford School of Medicine, Stanford, California, USA; Oral surgeon, State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Maziar Aghvami
- Division of Plastic and Reconstructive Surgery, Department of Surgery, Stanford School of Medicine, Stanford, California, USA
| | - Serdar Tulu
- Division of Plastic and Reconstructive Surgery, Department of Surgery, Stanford School of Medicine, Stanford, California, USA
| | - John B Brunski
- Division of Plastic and Reconstructive Surgery, Department of Surgery, Stanford School of Medicine, Stanford, California, USA
| | - Jill A Helms
- Division of Plastic and Reconstructive Surgery, Department of Surgery, Stanford School of Medicine, Stanford, California, USA
| |
Collapse
|
30
|
Mehboob H, Ahmad F, Tarlochan F, Mehboob A, Chang SH. A comprehensive analysis of bio-inspired design of femoral stem on primary and secondary stabilities using mechanoregulatory algorithm. Biomech Model Mechanobiol 2020; 19:2213-2226. [PMID: 32388685 DOI: 10.1007/s10237-020-01334-3] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2019] [Accepted: 04/26/2020] [Indexed: 12/11/2022]
Abstract
The coated porous section of stem surface is initially filled with callus that undergoes osseointegration process, which develops a bond between stem and bone, lessens the micromotions and transfers stresses to the bone, proximally. This phenomenon attributes to primary and secondary stabilities of the stems that exhibit trade-off the stem stiffness. This study attempts to ascertain the influence of stem stiffness on peri-prosthetic bone formation and stress shielding when in silico models of solid CoCr alloy and Ti alloy stems, and porous Ti stems (53.8 GPa and 31.5 GPa Young's moduli) were implanted. A tissue differentiation predictive mechanoregulation algorithm was employed to estimate the evolutionary bond between bone and stem interfaces with 0.5-mm- and 1-mm-thick calluses. The results revealed that the high stiffness stems yielded higher stress shielding and lower micromotions than that of low stiffness stems. Contrarily, bone formation around solid Ti alloy stem and porous Ti 53.8 GPa stem was augmented in 0.5-mm- and 1-mm-thick calluses, respectively. All designs of stems exhibited different rates of bone formation, diverse initial micromotions and stress shielding; however, long-term bone formation was coherent with different stress shielding. Therefore, contemplating the secondary stability of the stems, low stiffness stem (Ti 53.8 GPa) gave superior biomechanical performance than that of high stiffness stems.
Collapse
Affiliation(s)
- Hassan Mehboob
- Department of Engineering Management, College of Engineering, Prince Sultan University, P.O. Box No. 66833, Rafha Street, Riyadh, 11586, Saudi Arabia.
| | - Furqan Ahmad
- Department of Mechanical and Mechatronics Engineering, Dhofar University, P.O. Box 2509, 211, Salalah, Sultanate of Oman
| | - Faris Tarlochan
- Department of Mechanical and Industrial Engineering, Qatar University, Al Tarfa, 2713, Doha, Qatar
| | - Ali Mehboob
- School of Mechanical Engineering, Chung-Ang University, 221, Heukseok-Dong, Dongjak-Gu, Seoul, 156-756, Republic of Korea
| | - Seung Hwan Chang
- School of Mechanical Engineering, Chung-Ang University, 221, Heukseok-Dong, Dongjak-Gu, Seoul, 156-756, Republic of Korea
| |
Collapse
|
31
|
Örgel M, Liodakis E, Jaratjitwilai P, Harb A, Wirries N, Omar M, Krettek C, Aschoff HH. Three-year follow-up of changes of cortical bone thickness after implantation of Endo-Exo-Prosthesis (EEP) for transfemoral amputees. J Orthop Surg Res 2020; 15:164. [PMID: 32366315 PMCID: PMC7199357 DOI: 10.1186/s13018-020-01675-w] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/16/2020] [Accepted: 04/06/2020] [Indexed: 12/12/2022] Open
Abstract
Introduction Transcutaneous Osseointegrated Prosthetic Systems (TOPS) offer a good alternative for patients who cannot be satisfactorily rehabilitated by conventional suspension sockets. The Endo-Exo-Prothesis (EEP, ESKA Orthopaedic Handels GmbH®, Deutschland) is the most implanted TOPS in Germany. Previous studies have shown that cortical thickness increases after implantation of TOPS. The aim of this study is to determine changes of cortical thickness in relation to the time after implantation of the Endo-Fix-Stem. Patients and methods All transfemoral amputees treated by EEP from 2007 to 2013 were operated by the last author of this study. X-ray images of 4 follow-up intervals (postoperative, 3 months, 12 months, 3 years) were analyzed retrospectively. The femoral residuum was divided into 3 sections (proximal, middle, distal) with 2 measuring points in each section: medial and lateral. Cortical thickness was measured at these 6 points and compared at regular intervals using the Friedman test for non-parametric dependent variables. Results Thirty-seven patients with 40 implants were included. The average age was 52.2 years (30–79 years). 83.7% of the patients were male. No statistical significance could be shown for any of the measuring points of the femoral residual (proximal medial, proximal lateral, middle medial, middle lateral, distal medial, distal lateral) among the mean values of the cortical thickness at the different follow-up times (p > 0.05 for all measuring points). Cortical remodeling processes (> 1 millimeter (mm)) occurred in all implants despite a missing statistical significance. Hypertrophy could be confirmed for 42.5% and atrophy for 37.5%. Twenty percent of the cases showed a parallel occurrence of both entities. Cortical changes greater than 5 mm were only observed at the distal end of the femur. Conclusion Even if our results did not show any significant difference, it can be deduced that the osseointegration process leads to a remodeling of the bone structure, both in terms of increased bone formation and bone resorption. However, it has not yet been conclusively clarified which processes lead to hyper- or atrophy. The force transmission between prosthesis and bone and the facultative bacterial colonization of the stoma are still the main factors which may be responsible for the bone remodeling processes.
Collapse
Affiliation(s)
- Marcus Örgel
- Trauma Department, Hannover Medical School (MHH), Carl-Neuberg-Straße, 130625, Hannover, Germany.
| | - Emmanouil Liodakis
- Trauma Department, Hannover Medical School (MHH), Carl-Neuberg-Straße, 130625, Hannover, Germany
| | | | - Afif Harb
- Trauma Department, Hannover Medical School (MHH), Carl-Neuberg-Straße, 130625, Hannover, Germany
| | - Nils Wirries
- Orthopaedic Department, DiakovereAnnastift, Hannover, Germany
| | - Mohamed Omar
- Trauma Department, Hannover Medical School (MHH), Carl-Neuberg-Straße, 130625, Hannover, Germany
| | - Christian Krettek
- Trauma Department, Hannover Medical School (MHH), Carl-Neuberg-Straße, 130625, Hannover, Germany
| | - Horst-Heinrich Aschoff
- Trauma Department, Hannover Medical School (MHH), Carl-Neuberg-Straße, 130625, Hannover, Germany
| |
Collapse
|
32
|
Aggressive granulomatosis of the hip: a forgotten mode of aseptic failure. INTERNATIONAL ORTHOPAEDICS 2018; 43:1321-1328. [PMID: 30506086 DOI: 10.1007/s00264-018-4252-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2018] [Accepted: 11/25/2018] [Indexed: 02/08/2023]
Abstract
PURPOSE It has been acknowledged that implant wear correlates with the risk for periprosthetic osteolysis, being aggressive granulomatosis the worst expression of bone resorption. We sought to determine the clinical, radiological, and histological features of aggressive granulomatosis after primary total hip arthroplasty (THA). METHODS We included nine cases with aggressive granulomatosis of the hip around cemented stems. Indications for revision THA consisted of progressive signs of extensive bone resorption or implant loosening. Mean follow-up since revision THA was 143 months (SD ± 59.4). We analysed clinical outcomes, component loosening and gross as well as histological characteristics of the granulomatous lesions. RESULTS Overall mean time between primary THA and revision surgery was 81 months (SD ± 20.8). All of the cases evidenced multiple ovoid tumour-like lesions around the stem with extensive bone loss. Only one case reported thigh pain before revision surgery, with radiological evidence of stem loosening; the remaining cases were asymptomatic with well-fixed implants. Gross anatomy findings revealed metallosis in the femoral canal and inside the cystic lesions. Pathology analysis showed monocyte-macrophage-dominated adverse foreign-body-type tissue reaction with fibroblastic reactive zones and granulomatous inflammation. CONCLUSIONS We found a prevalence of 1% of this aseptic mode of implant failure. Since most of the retrieved stems were not loose, we did not find any alarming clinical symptoms anticipating implant failure. In this scenario, surgeons should be aware of the rapidly progressive nature of this entity and propose a revision THA in a timely fashion.
Collapse
|
33
|
Qin P, Liu Y, Sercombe TB, Li Y, Zhang C, Cao C, Sun H, Zhang LC. Improved Corrosion Resistance on Selective Laser Melting Produced Ti-5Cu Alloy after Heat Treatment. ACS Biomater Sci Eng 2018; 4:2633-2642. [DOI: 10.1021/acsbiomaterials.8b00319] [Citation(s) in RCA: 67] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Affiliation(s)
- Peng Qin
- School of Engineering, Edith Cowan University, 270 Joondalup Drive, Joondalup, Perth, Western Australia 6027, Australia
| | - Yujing Liu
- School of Engineering, The University of Western Australia, 35 Stirling Highway, Crawley, Perth, Western Australia 6009, Australia
| | - Timothy B. Sercombe
- School of Engineering, The University of Western Australia, 35 Stirling Highway, Crawley, Perth, Western Australia 6009, Australia
| | - Yuhua Li
- School of Mechanical Engineering, Xi’an University of Science and Technology, Xi’an 710054, China
| | - Chuanwei Zhang
- School of Mechanical Engineering, Xi’an University of Science and Technology, Xi’an 710054, China
| | - Chongde Cao
- Research & Development Institute in Shenzhen and Department of Applied Physics, Northwestern Polytechnical University, Xi’an 710072, China
| | - Hongqi Sun
- School of Engineering, Edith Cowan University, 270 Joondalup Drive, Joondalup, Perth, Western Australia 6027, Australia
| | - Lai-Chang Zhang
- School of Engineering, Edith Cowan University, 270 Joondalup Drive, Joondalup, Perth, Western Australia 6027, Australia
| |
Collapse
|
34
|
Aro E, Moritz N, Mattila K, Aro HT. A long-lasting bisphosphonate partially protects periprosthetic bone, but does not enhance initial stability of uncemented femoral stems: A randomized placebo-controlled trial of women undergoing total hip arthroplasty. J Biomech 2018; 75:35-45. [PMID: 29747966 DOI: 10.1016/j.jbiomech.2018.04.041] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2017] [Revised: 03/10/2018] [Accepted: 04/22/2018] [Indexed: 01/29/2023]
Abstract
Low bone quality may compromise the success of cementless total hip arthroplasty in high-risk patients such as elderly women. Zoledronic acid is a long-lasting antiresorptive agent, which is known to reduce short-term periprosthetic bone loss. However, its effect on femoral stem stability is not well known. Forty-nine female patients with a mean age of 68 years (range, 51-85 years) scheduled to undergo cementless total hip arthroplasty due to osteoarthritis were randomized in this double-blind, placebo-controlled trial to receive a single postoperative infusion of zoledronic acid or placebo. Patients were evaluated for up to four years postoperatively for femoral stem migration measured by radiostereometric analysis, bone mineral density (BMD) measured by dual X-ray absorptiometry, functional recovery, and patient-reported outcome scores. Implant survival was determined at nine years postoperatively. Zoledronic acid did not reduce the femoral stem migration that occurred predominantly during the settling period of the first 3-6 months. Subsequently, all femoral stems were radiographically osseointegrated. Zoledronic acid maintained periprosthetic BMD, while the expected loss of periprosthetic bone during the first 12 months was found in controls. Thereafter, periprosthetic BMD of Gruen zone 7 decreased even in the zoledronic acid group but remained 14.6% higher than that in the placebo group at four years postoperatively. Functional recovery was comparable across the groups. At nine years postoperatively, no revision arthroplasty had been performed. In conclusion, in women at high-risk for low BMD, zoledronic acid had a long-lasting, partially protective effect on periprosthetic bone loss, but the treatment did not enhance the initial femoral stem stability.
Collapse
Affiliation(s)
- Erik Aro
- Department of Orthopedic Surgery and Traumatology, Turku University Hospital and University of Turku, FI-20521 Turku, Finland.
| | - Niko Moritz
- Department of Orthopedic Surgery and Traumatology, Turku University Hospital and University of Turku, FI-20521 Turku, Finland.
| | - Kimmo Mattila
- Department of Diagnostic Imaging, Turku University Hospital, FI-20521 Turku, Finland.
| | - Hannu T Aro
- Department of Orthopedic Surgery and Traumatology, Turku University Hospital and University of Turku, FI-20521 Turku, Finland.
| |
Collapse
|