1
|
Mathunny JJ, Srinivasan HK, Kumar A, Karthik V. A Cross-Sectional Study on Fall Direction and Lower Limb Loading in Response to a Perturbation on Laterally Inclined Platform. Appl Bionics Biomech 2023; 2023:7385119. [PMID: 37928743 PMCID: PMC10624552 DOI: 10.1155/2023/7385119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Revised: 10/02/2023] [Accepted: 10/03/2023] [Indexed: 11/07/2023] Open
Abstract
Perturbation-based balance training (PBT) improves reactive stepping in older adults and people with neurological disorders. Slip-induced falls are a threat to older adults, leading to hip fractures. Fall-prone individuals must be trained to regain balance during a fall in the posterolateral direction. This study aims to analyze the characteristics of the reactive step induced by a laterally inclined platform. This cross-sectional study included 46 healthy participants who performed a "lean and release" backward fall using a platform with two inclined angles on each side. Kinovea software was used to analyze the step width. Reactive steps, characterized by crossover or medial foot placement, are preventive measures against posterolateral falls. The first objective was on the narrowed step width that was subjected to analysis using analysis of variance (ANOVA) and Tukey's post hoc assessment, indicating a tendency toward posterolateral falls. As part of our second objective, the inclined platform resulted in uneven loading between the legs, with a preference for the unloaded leg as the reactive leg (p < 0.001), as determined by Fisher's exact test and Cramer's V. These characteristics align closely with those observed in modified constraint-induced movement therapy (mCIMT). The angled platform had a significant effect on selecting the reactive leg, particularly at higher angles (p < 0.001). Thus, the study suggested that the device is capable of inducing posterolateral falls and exhibited mCIMT characteristics.
Collapse
Affiliation(s)
- Jaison Jacob Mathunny
- Department of Biomedical Engineering, SRM Institute of Science and Technology, Kattankulathur, Chennai 603203, Tamil Nadu, India
| | - Hari Krishnan Srinivasan
- Department of Biomedical Engineering, SRM Institute of Science and Technology, Kattankulathur, Chennai 603203, Tamil Nadu, India
| | - Ashok Kumar
- Department of Biomedical Engineering, SRM Institute of Science and Technology, Kattankulathur, Chennai 603203, Tamil Nadu, India
| | - Varshini Karthik
- Department of Biomedical Engineering, SRM Institute of Science and Technology, Kattankulathur, Chennai 603203, Tamil Nadu, India
| |
Collapse
|
2
|
Mesquita Souza RL, Aidar FJ, Villar R, Greco G, Santos LD, Poli L, Lima de Santana J, Carvutto R, Gama de Matos D, Badicu G, Silva AF, Clemente FM, Nobari H, Fischetti F, Cataldi S. Assessment of asymmetry at different intensities between conventional and paralympic powerlifting athletes. Heliyon 2023; 9:e16211. [PMID: 37251905 PMCID: PMC10213187 DOI: 10.1016/j.heliyon.2023.e16211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2023] [Revised: 05/09/2023] [Accepted: 05/10/2023] [Indexed: 05/31/2023] Open
Abstract
Powerlifting competitions require consistent and symmetric lifting of heavy loads and maximal effort, in which, asymmetric lifting results in trial invalidation. Symmetry during this very high intensity movement is determinant to athletes' performance and success in competitions. This study aimed to compare the asymmetry between Conventional Powerlifting athletes (CP) and Paralympic (PP) athletes at intensities of 45 and 80% 1RM before and after a training session. Twenty-two male athletes (11 CP: 29.84 ± 4.21 and 11 PP: 30.81 ± 8.05 years old) participated in this study. Mean Propulsive Velocity (MPV), Maximum Velocity (Vmax) and Power during the concentric and eccentric phases were evaluated at 45%-1RM before and after a training session. For the intensity of 80%-1RM, MPV, Vmax and Power were measured in the first and last series (5 series of 5 repetitions: 5X5) of a training session. PP athletes demonstrated lower velocity and greater symmetry at 45%-1RM, but higher velocity and less asymmetry at 80%-1RM, when compared to CP. The data indicated that PP athletes tend to be slower at lower intensities, faster at higher intensities in absolute values, and have greater symmetry than CP.
Collapse
Affiliation(s)
- Rafael Luiz Mesquita Souza
- Graduate Program of Physical Education, Federal University of Sergipe (UFS), São Cristovão 49100-000, Brazil
- Group of Studies and Research of Performance, Sport, Health and Paralympic Sports (GEPEPS), Federal University of Sergipe (UFS), São Cristovão 49100-000, Brazil
| | - Felipe J. Aidar
- Graduate Program of Physical Education, Federal University of Sergipe (UFS), São Cristovão 49100-000, Brazil
- Group of Studies and Research of Performance, Sport, Health and Paralympic Sports (GEPEPS), Federal University of Sergipe (UFS), São Cristovão 49100-000, Brazil
- Department of Physical Education, Federal University of Sergipe (UFS), São Cristovão 49100-000, Brazil
- Graduate Program of Physiological Science, Federal University of Sergipe (UFS), São Cristovão 49100-000, Brazil
- Cardiorespiratory & Physiology of Exercise Research Laboratory, Faculty of Kinesiology and Recreation Management, University of Manitoba, Winnipeg, MB R3T 2N2, Canada
| | - Rodrigo Villar
- Cardiorespiratory & Physiology of Exercise Research Laboratory, Faculty of Kinesiology and Recreation Management, University of Manitoba, Winnipeg, MB R3T 2N2, Canada
| | - Gianpiero Greco
- Department of Translational Biomedicine and Neuroscience (DiBraiN), University of Study of Bari, 70124 Bari, Italy
| | - Leonardo dos Santos
- Graduate Program of Physical Education, Federal University of Sergipe (UFS), São Cristovão 49100-000, Brazil
- Group of Studies and Research of Performance, Sport, Health and Paralympic Sports (GEPEPS), Federal University of Sergipe (UFS), São Cristovão 49100-000, Brazil
| | - Luca Poli
- Department of Translational Biomedicine and Neuroscience (DiBraiN), University of Study of Bari, 70124 Bari, Italy
| | - Jefferson Lima de Santana
- Cardiorespiratory & Physiology of Exercise Research Laboratory, Faculty of Kinesiology and Recreation Management, University of Manitoba, Winnipeg, MB R3T 2N2, Canada
| | - Roberto Carvutto
- Department of Translational Biomedicine and Neuroscience (DiBraiN), University of Study of Bari, 70124 Bari, Italy
| | - Dihogo Gama de Matos
- Cardiorespiratory & Physiology of Exercise Research Laboratory, Faculty of Kinesiology and Recreation Management, University of Manitoba, Winnipeg, MB R3T 2N2, Canada
| | - Georgian Badicu
- Department of Physical Education and Special Motricity, Transilvania University of Brasov, 500068 Brasov, Romania
| | - Ana Filipa Silva
- Sports and Leisure School, Polytechnic Institute of Viana do Castelo, Rua Escola Industrial e Comercial de Nun'Álvares, 4900-347 Viana do Castelo, Portugal
- Research Center in Sports Performance, Recreation, Innovation and Technology (SPRINT), 4960-320 Melgaço, Portugal
- The Research Centre in Sports Sciences, Health Sciences and Human Development (CIDESD), 5001-801 Vila Real, Portugal
| | - Filipe Manuel Clemente
- Escola Superior Desporto e Lazer, Instituto Politécnico de Viana do Castelo, Rua Escola Industrial e Comercial de Nun'Álvares, 4900-347 Viana do Castelo, Portugal
- Instituto de Telecomunicações, Delegação da Covilhã, 1049-001 Lisboa, Portugal
| | - Hadi Nobari
- Faculty of Sport Sciences, University of Extremadura, 10003 Cáceres, Spain
| | - Francesco Fischetti
- Department of Translational Biomedicine and Neuroscience (DiBraiN), University of Study of Bari, 70124 Bari, Italy
| | - Stefania Cataldi
- Department of Translational Biomedicine and Neuroscience (DiBraiN), University of Study of Bari, 70124 Bari, Italy
| |
Collapse
|
3
|
An evaluation of temporal and club angle parameters during golf swings using low cost video analyses packages. Sci Rep 2022; 12:14012. [PMID: 35977946 PMCID: PMC9385988 DOI: 10.1038/s41598-022-17175-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2022] [Accepted: 07/21/2022] [Indexed: 12/03/2022] Open
Abstract
The purpose of this study was to compare swing time and golf club angle parameters during golf swings using three, two dimensional (2D) low cost, Augmented-Video-based-Portable-Systems (AVPS) (Kinovea, SiliconCoach Pro, SiliconCoach Live). Twelve right-handed golfers performed three golf swings whilst being recorded by a high-speed 2D video camera. Footage was then analysed using AVPS-software and the results compared using both descriptive and inferential statistics. There were no significant differences for swing time and the golf phase measurements between the 2D and 3D software comparisons. In general, the results showed a high Intra class Correlation Coefficient (ICC > 0.929) and Cronbach’s Coefficient Alpha (CCA > 0.924) reliability for both the kinematic and temporal parameters. The inter-rater reliability test for the swing time and kinematic golf phase measurements on average were strong. Irrespective of the AVPS software investigated, the cost effective AVPS can produce reliable output measures that benefit golf analyses.
Collapse
|