1
|
Soltani N, Sadeghi T, Mahmoodi MR, Saadloo M, Baneshi MR, Rajabi Z, Shamsizadeh A. The biotoxic effects of heavy metals exposure in miners and non-miners. J Trace Elem Med Biol 2024; 84:127423. [PMID: 38503128 DOI: 10.1016/j.jtemb.2024.127423] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Revised: 03/03/2024] [Accepted: 03/03/2024] [Indexed: 03/21/2024]
Abstract
Since little is known about the comparison of the biotoxic effects of heavy metals exposure on biochemical and hematological parameters in miners and non-miners, the current study aimed to compare the effects of arsenic (As), lead (Pb), and copper (Cu) in both groups. Demographic information and blood samples were collected from all participants and measures of As, Pb and Cu were obtained using Atomic Absorption Spectrophotometry. As and Pb mean concentrations in miners and Cu concentration were greater in non-miners. Miners also showed significantly higher level of RBC, HBG and HCT. In the adjusted model, cholesterol showed a positively association with Pb and Cu levels. Triglycerides, GGT, ALP, WBC and PLT positively and HDL-cholesterol negatively were associated with Cu. Creatinine was negatively associated with group variable. In conclusion, miners' high blood heavy metals concentrations can impact biochemical and hematological indices. These observations make monitoring of heavy metals necessary in miners.
Collapse
Affiliation(s)
- Narjes Soltani
- Physiology-Pharmacology Research Center, Research Institute of Basic Medical Sciences, Iran; Non-Communicable Diseases Research Center, Rafsanjan University of Medical Sciences, Rafsanjan, Iran
| | - Tabandeh Sadeghi
- Department of Pediatric Nursing, School of Nursing and Midwifery; Non-Communicable Diseases Research Center, Rafsanjan University of Medical Sciences, Rafsanjan, Iran
| | - Mohammad Reza Mahmoodi
- Physiology Research Center, Institute of Neuropharmacology & Department of Nutrition, Faculty of Health, Kerman University of Medical Sciences, Kerman, Iran
| | - Majid Saadloo
- Occupational Safety and Health Research Center, NICICO, WSO and Rafsanjan University of Medical Sciences, Rafsanjan, Iran
| | | | - Zohreh Rajabi
- Non-Communicable Diseases Research Center, Rafsanjan University of Medical Sciences, Rafsanjan, Iran
| | - Ali Shamsizadeh
- Occupational Safety and Health Research Center, NICICO, WSO and Rafsanjan University of Medical Sciences, Rafsanjan, Iran.
| |
Collapse
|
2
|
Dehghani F, Yousefinejad S, Mobaraki N, Nekoeinia M, Hemmateenejad B. Rapid determination of hippuric acid as an exposure biomarker of toluene using a colorimetric assay and comparison with high-performance liquid chromatography. Sci Rep 2024; 14:9935. [PMID: 38688900 PMCID: PMC11061108 DOI: 10.1038/s41598-024-59641-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Accepted: 04/12/2024] [Indexed: 05/02/2024] Open
Abstract
Occupational exposure to toluene is associated with health risks that require reliable monitoring methods. Hippuric acid (HA), a urinary metabolite of toluene, serves as a valuable biomarker for such exposure. Colorimetric methods for the quantitative determination of HA have gained prominence due to their simplicity, cost-effectiveness, and suitability for field application. In the present study, a simple colorimetric technique was optimized for the determination of HA in the urine sample, and compared with a usual HPLC technique. The central composite design (CCD) was applied to examine the effective parameters on the colorimetric determination of HA. The calibration curve for HA was established within the concentration range of 6 to 100 mg L-1 with R2 = 0.97. The detection limit (LOD) and quantification limit (LOQ) were determined to be 1.8 mg L-1 and 6 mg L-1 respectively. The relative standard deviation (RSD%) was less than 5%, and the recovery% (R%) was 90.5-100.1. The overall results showed good agreement between the colorimetric and HPLC results. There was a significant relationship between the results obtained from HPLC and colorimetric methods especially for higher concentration levels of HA (≥ 500 mg/g creatinine). In conclusion, our optimized colorimetric method is a simple, cost-effective, and rapid method for determination of HA in occupational exposure, which is comparable with the HPLC technique.
Collapse
Affiliation(s)
- Fatemeh Dehghani
- Student Research Committee, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Saeed Yousefinejad
- Department of Occupational Health Engineering, School of Health, Shiraz University of Medical Sciences, Shiraz, Iran.
| | - Nabiollah Mobaraki
- Institute of Medicinal and Pharmaceutical Chemistry, University of Technology Braunschweig, Braunschweig, Germany
| | - Mohsen Nekoeinia
- Soil and Water Research Department, Isfahan Agricultural and Natural Resources Research and Education Center, AREEO, Isfahan, Iran
| | | |
Collapse
|
3
|
Gao H, Chai J, Jin C, Tian M. Molecularly imprinted electrochemical sensor based on CoNi-MOF/RGO nanocomposites for sensitive detection of the hippuric acid. Anal Chim Acta 2024; 1296:342307. [PMID: 38401927 DOI: 10.1016/j.aca.2024.342307] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Revised: 01/17/2024] [Accepted: 01/29/2024] [Indexed: 02/26/2024]
Abstract
Toluene, a volatile organic compound, may have adverse effects on the nervous and digestive system when inhaled over an extended period. The assessment of environmental toluene exposure can be effectively conducted by detecting hippuric acid (HA), a toluene metabolite. In this investigation, a molecularly imprinted electrochemical sensor was developed for HA detection, utilizing the synergistic effects of reduced graphene oxide (RGO) and a bimetallic organic skeleton known as CoNi-MOF. Initially, graphene oxide (GO) was synthesized using a modified Hummers' method, and RGO with better conductivity was achieved through reduction with ascorbic acid (AA). Subsequently, CoNi-MOF was introduced to enhance the material's electron transport capabilities further. The molecularly imprinted membrane was then prepared via electropolymerization to enable selective HA recognition. Under optimal conditions, the synthesized sensor exhibited accurate HA detection within a concentration range of 2-800 nM, with a detection limit of 0.97 nM. The sensor's selectivity was assessed using a selectivity coefficient, yielding an imprinting factor of 6.53. The method was successfully applied to the quantification of HA in urine, demonstrating a favorable recovery rate of 93.4%-103.9%. In conclusion, this study presents a practical platform for the detection of human metabolite detection.
Collapse
Affiliation(s)
- Haifeng Gao
- Key Laboratory of Photochemical Biomaterials and Energy Storage Materials, Heilongjiang Province, College of Chemistry and Chemical Engineering, Harbin Normal University, Harbin, 150025, PR China
| | - Jinyue Chai
- Key Laboratory of Photochemical Biomaterials and Energy Storage Materials, Heilongjiang Province, College of Chemistry and Chemical Engineering, Harbin Normal University, Harbin, 150025, PR China
| | - Chengcheng Jin
- Key Laboratory of Photochemical Biomaterials and Energy Storage Materials, Heilongjiang Province, College of Chemistry and Chemical Engineering, Harbin Normal University, Harbin, 150025, PR China
| | - Miaomiao Tian
- Key Laboratory of Photochemical Biomaterials and Energy Storage Materials, Heilongjiang Province, College of Chemistry and Chemical Engineering, Harbin Normal University, Harbin, 150025, PR China.
| |
Collapse
|
4
|
Cerrato A, Aita SE, Cavaliere C, Laganà A, Montone CM, Piovesana S, Taglioni E, Capriotti AL. Preparation of Monolith for Online Extraction and LC-MS Analysis of β-Estradiol in Serum Via a Simple Multicomponent Reaction. Anal Chem 2024; 96:4639-4646. [PMID: 38501258 DOI: 10.1021/acs.analchem.3c05706] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/20/2024]
Abstract
Multicomponent reactions offer efficient and environmentally friendly strategies for preparing monoliths suitable for applications in analytical chemistry. In the described study, a multicomponent reaction was utilized for the one-pot miniaturized preparation of a poly(propargyl amine) polymer inside commercial silica-lined PEEK tubing. The reaction involved only small amounts of reagents and was characterized by atom economy. The resulting monolithic column was incorporated into an autosampler system for the online extraction and cleanup of β-estradiol from human serum. Sample pretreatment was simplified to a simple dilution with methanol and centrifugation to remove proteins. The resulting platform included LC-MS analysis in multiple reaction monitoring for quantitative analysis of β-estradiol. The method was validated in serum, demonstrating practical applicability for the monitoring of fertile women. Recoveries were above 94%, and LOD and LOQ values at 0.008 and 0.18 ng mL-1, respectively. The developed platform proved to be competitive with previous methods for solid-phase microextraction of β-estradiol in serum, with comparable recovery and sensitivity but with the advantage of nearly complete automation. The environmental impact of the process was evaluated as acceptable due to the miniaturization of the monolith synthesis and the automation of extraction. The drawback associated with the LC-MS technique can be reduced by the inclusion of additional analytes in a single investigation. The work demonstrates that multicomponent reactions are versatile, economical, and possibly a green methodology for producing reversed-phase and mixed-mode sorbents, enabling miniaturization of the entire analytical procedure from the preparation of extraction sorbents to analysis.
Collapse
Affiliation(s)
- Andrea Cerrato
- Department of Chemistry, Università di Roma La Sapienza, Piazzale Aldo Moro 5, 00185 Rome, Italy
| | - Sara Elsa Aita
- Department of Chemistry, Università di Roma La Sapienza, Piazzale Aldo Moro 5, 00185 Rome, Italy
| | - Chiara Cavaliere
- Department of Chemistry, Università di Roma La Sapienza, Piazzale Aldo Moro 5, 00185 Rome, Italy
| | - Aldo Laganà
- Department of Chemistry, Università di Roma La Sapienza, Piazzale Aldo Moro 5, 00185 Rome, Italy
| | - Carmela Maria Montone
- Department of Chemistry, Università di Roma La Sapienza, Piazzale Aldo Moro 5, 00185 Rome, Italy
| | - Susy Piovesana
- Department of Chemistry, Università di Roma La Sapienza, Piazzale Aldo Moro 5, 00185 Rome, Italy
| | - Enrico Taglioni
- Department of Chemistry, Università di Roma La Sapienza, Piazzale Aldo Moro 5, 00185 Rome, Italy
| | - Anna Laura Capriotti
- Department of Chemistry, Università di Roma La Sapienza, Piazzale Aldo Moro 5, 00185 Rome, Italy
| |
Collapse
|