1
|
Katsianos E, Oikonomou E, Kalogeras K, Manousaki A, Kalantzis C, Pantelidis P, Vavuranakis MA, Aggeli K, Siasos G, Tsioufis C, Vavuranakis M. Residual Right-to-Left-Shunt Following Transcatheter Patent Foramen Ovale Closure: The Role of Antithrombotic Treatment. Curr Pharm Des 2022; 28:3305-3312. [PMID: 36306457 DOI: 10.2174/1381612829666221028095839] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2022] [Accepted: 09/26/2022] [Indexed: 01/28/2023]
Abstract
BACKGROUND Transcatheter closure of patent foramen ovale (PFO) is a highly effective therapy for patients with left circulation thromboembolism, not attributable to other conditions. OBJECTIVES This retrospective cohort study investigates the impact of baseline foramen ovale anatomy on the severity of the postclosure shunt. METHODS Patients with PFO, who underwent percutaneous closure, were followed up for at least 5 years postimplantation. Patients were classified into two groups based on the presence of high-risk features of the baseline PFO anatomy. At the follow-up follow-up, residual right-to-left shunt was assessed for the high and non-highrisk anatomy groups, via transcranial Doppler at rest and after performing the Valsalva maneuver, with the injection of agitated saline. RESULTS 38 patients were examined after a mean follow-up period of 9 ± 3 years after implantation. After retrospective evaluation of the baseline transthoracic and transesophageal echo studies, 14 patients with high-risk PFO anatomy were identified. The degree of the residual right-to-left shunt, as assessed by the number of microbubbles was higher in the high-risk PFO anatomy group compared to the non-high-risk group, both at rest [1.50 (IQR: 0.00-3.25) vs. 0.00 (IQR: 0.00-0.00), p < 0.001] and post-Valsalva maneuver [7.50 (IQR: 1.50- 10.25) vs. 0.00 (IQR: 0.00-3.75), p = 0.003]. Furthermore, in the high-risk group, more microbubbles were detected at rest (p = 0.008) and post-Valsalva (p = 0.002) in subjects without antiplatelet treatment compared to subjects on prolonged antiplatelet therapy. CONCLUSION Baseline PFO anatomy affects the severity of the residual right-to-left shunt. Prolonged antiplatelet therapy may benefit patients with high-risk anatomical features.
Collapse
Affiliation(s)
- Efstratios Katsianos
- 3rd Cardiology Clinic, National and Kapodistrian University of Athens, Medical School, Sotiria Chest Disease Hospital, Athens. Greece
| | - Evangelos Oikonomou
- 3rd Cardiology Clinic, National and Kapodistrian University of Athens, Medical School, Sotiria Chest Disease Hospital, Athens. Greece.,1st Cardiology Clinic, National and Kapodistrian University of Athens, Medical School, "Hippokration" General Hospital, Athens, Greece
| | - Konstantinos Kalogeras
- 3rd Cardiology Clinic, National and Kapodistrian University of Athens, Medical School, Sotiria Chest Disease Hospital, Athens. Greece
| | - Alexandra Manousaki
- 1st Cardiology Clinic, National and Kapodistrian University of Athens, Medical School, "Hippokration" General Hospital, Athens, Greece
| | - Charalambos Kalantzis
- 1st Cardiology Clinic, National and Kapodistrian University of Athens, Medical School, "Hippokration" General Hospital, Athens, Greece
| | - Panteleimon Pantelidis
- 3rd Cardiology Clinic, National and Kapodistrian University of Athens, Medical School, Sotiria Chest Disease Hospital, Athens. Greece
| | | | - Konstantina Aggeli
- 3rd Cardiology Clinic, National and Kapodistrian University of Athens, Medical School, Sotiria Chest Disease Hospital, Athens. Greece
| | - Gerasimos Siasos
- 3rd Cardiology Clinic, National and Kapodistrian University of Athens, Medical School, Sotiria Chest Disease Hospital, Athens. Greece.,1st Cardiology Clinic, National and Kapodistrian University of Athens, Medical School, "Hippokration" General Hospital, Athens, Greece
| | - Costas Tsioufis
- 1st Cardiology Clinic, National and Kapodistrian University of Athens, Medical School, "Hippokration" General Hospital, Athens, Greece
| | - Manolis Vavuranakis
- 3rd Cardiology Clinic, National and Kapodistrian University of Athens, Medical School, Sotiria Chest Disease Hospital, Athens. Greece.,1st Cardiology Clinic, National and Kapodistrian University of Athens, Medical School, "Hippokration" General Hospital, Athens, Greece
| |
Collapse
|
2
|
Application of Transesophageal Echocardiography in Amplatzer Atrial Septal Defect Occluder for Percutaneous Closure of Large Patent Foramen Ovale. Cardiovasc Ther 2022; 2022:3226080. [PMID: 35936794 PMCID: PMC9337921 DOI: 10.1155/2022/3226080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/17/2022] [Revised: 06/07/2022] [Accepted: 06/21/2022] [Indexed: 11/17/2022] Open
Abstract
Objective. The Amplatzer patent foramen ovale (PFO) occluder is the most commonly used device for percutaneous closure of a large PFO. However, its use may predispose the patient to postoperative residual shunting. To reduce the incidence of residual shunting, we investigated the safety and effectiveness of the Amplatzer atrial septal defect (ASD) occluder for percutaneous closure of a large PFO measured by transesophageal echocardiography (TEE) and evaluated the value of TEE in this procedure. Methods. Overall, 118 patients who were diagnosed with a large PFO (all with
mm left atrial side height after the Valsalva maneuver (VM) excluding those with a small ASD) using contrast transthoracic echocardiography (c-TTE) and TEE underwent closure under TEE guidance at The First Affiliated Hospital of Xi’an Jiaotong University. An ASD device was used in 48 patients (group I) and a PFO device in 70 (group II). After the procedure, we verified the safety and efficacy of different devices using c-TTE, TTE, and TEE. Results. In both groups, the preoperative TEE results showed a significantly increased left height of the PFO after VM compared with that at rest (all
). Compared with the left height of the PFO measured using TEE after VM, the PFO-stretch diameter (SD) measured by TEE after the delivery sheath passed the PFO was higher (all
). We selected the ASD occluder size according to this PFO-SD. In group II, most patients underwent the implantation of the larger PFO devices. Interventional treatment was successfully performed on all patients. The effective occlusion rate in group I at 12 months after the procedure was significantly higher than that in group II (93.7% vs. 78.6%,
). The TEE results showed that 18 patients with a medium and large residual shunt at 12 months after the procedure exhibited an intradisc tunnel-like shunt. Conclusion. The Amplatzer ASD device and Amplatzer PFO device are safe for large PFO closure, but the Amplatzer ASD device has a higher effective occlusion rate. TEE plays a crucial role in the use of the Amplatzer ASD occluder for percutaneous closure of a large PFO.
Collapse
|
3
|
Shah AH, Puri R, Krasuski RA. Transcatheter Closure of Patent Foramen Ovale: Not Always an "Open or Shut" Case. Circulation 2021; 143:1539-1541. [PMID: 33872078 DOI: 10.1161/circulationaha.120.050961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Affiliation(s)
- Ashish H Shah
- St Boniface Hospital, Section of Cardiology, University of Manitoba, Winnipeg, Canada (A.H.S.)
| | - Rishi Puri
- Department of Cardiovascular Medicine, Cleveland Clinic Coordinating Center for Clinical Research, Cleveland Clinic, Ohio (R.P.)
| | - Richard A Krasuski
- Division of Cardiology, Duke University Health System, Durham, NC (R.A.K.)
| |
Collapse
|
4
|
Wang J, Zhang J, Wang A, Wang C. Pulmonary arteriovenous fistula diagnosed by transthoracic contrast echocardiography: A case report. JOURNAL OF CLINICAL ULTRASOUND : JCU 2021; 49:298-300. [PMID: 33527455 DOI: 10.1002/jcu.22981] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/11/2020] [Revised: 01/10/2021] [Accepted: 01/18/2021] [Indexed: 06/12/2023]
Abstract
We report the case of a 38-year-old woman who was admitted due to right limb numbness. A right-to-left shunt (RLS) was detected by transthoracic contrast echocardiography (cTTE), and microbubbles appeared in the left heart seven cardiac cycles after opacification of the right heart, suggesting pulmonary arteriovenous fistula. This was supported by computed tomography angiography. She underwent thoracoscopic partial right lower pneumonectomy and recovered after surgery. At 1 year follow-up, she had no relapse of stroke or cerebral infarction. This case shows the typical signs of pulmonary arteriovenous fistula on contrast-enhanced trans-thoracic echocardiography, which allowed an accurate and rapid diagnosis.
Collapse
Affiliation(s)
- Jing Wang
- Department of Medical Ultrasound, Zhejiang Provincial People's Hospital, People's Hospital of HangZhou Medical College, Hangzhou, China
| | - Jian Zhang
- Department of Medical Ultrasound, Zhejiang Provincial People's Hospital, People's Hospital of HangZhou Medical College, Hangzhou, China
| | - Anlong Wang
- Department of Radiology, Zhejiang Provincial Integrated Chinese and Western Medicine Hospital, Hangzhou Red Cross Hospital, Hangzhou, China
| | - Ceng Wang
- Department of Medical Ultrasound, Zhejiang Provincial People's Hospital, People's Hospital of HangZhou Medical College, Hangzhou, China
| |
Collapse
|
5
|
Kussmaul WG. Different Strokes. Ann Intern Med 2020; 172:761-762. [PMID: 32422067 DOI: 10.7326/m20-1879] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
|
6
|
Han Y, Zhang X, Zhang F. Patent foramen ovale closure by using transesophageal echocardiography for cryptogenic stroke: single center experience in 132 consecutive patients. J Cardiothorac Surg 2020; 15:11. [PMID: 31918738 PMCID: PMC6953465 DOI: 10.1186/s13019-020-1042-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2019] [Accepted: 01/02/2020] [Indexed: 01/23/2023] Open
Abstract
Background Percutaneous closure of patent foramen ovale (PFO) is routinely performed using plain fluoroscopy in the catheter room. This method results in inevitable radiation damage, adverse effects of contrast agents on kidneys, and high cost. We performed PFO closure with a simplified and economical transesophageal echocardiography (TEE)-only guided approach in the operating room. This study aimed to investigate the feasibility, safety, and effectiveness of the percutaneous closure of PFO by only using TEE. Methods We reviewed the medical records of patients who underwent percutaneous PFO closure at our center from December 2013 to December 2017. A total of 132 patients with PFO and cryptogenic strokes underwent PFO closure by using cardi-O-fix PFO device under TEE guidance. The participants comprised 64 and 68 male and female patients, respectively. The mean age and body weight of the patients were 39.40 ± 13.22 years old (12–68 years old) and 65.42 ± 9.70 kg (40–95 kg), respectively. All patients only received aspirin (3–5 mg/kg body weight, oral administration) for 6 months. Contrast-enhanced transthoracic echocardiography (c-TTE) with Valsalva maneuver was performed during follow-up, and questionnaire surveys were obtained at 3, 6, and 12 months after the procedure. Results All (100%) patients were successfully closed. Follow-ups were conducted for 13 months to 48 months, with an average of 27 months. No severe complications were found during the follow-up period. Paroxysmal atrial fibrillation occurred in 4 patients within 3 months after the procedure. No recurrent stroke or death occurred in all patients during the follow-up period. Transient ischemic attack occurred in one patient 6 months after the procedure. Ten (7.6%) patients had a right-to-left shunt, as demonstrated by c-TTE at 12 months of follow-up. Among the 57 patients suffering from migraine, significant relief or resolution was reported by 42 (73.7%) patients. Conclusion TEE-only guided PFO closure was a safe, feasible, and effective method that did not require the use of X-rays and contrast agents.
Collapse
Affiliation(s)
- Yangyang Han
- Department of Cardiovascular Surgery, Qilu Hospital of Shandong University, West Wenhua Road No.107, Lixia District, Jinan, 250012, Shandong Province, China.,Department of Cardiovascular Surgery, Linyi People's Hospital Affiliated to Shandong University, Jiefang Street No. 27, Linyi, 276000, Shandong Province, China
| | - Xiquan Zhang
- Department of Cardiovascular Surgery, Linyi People's Hospital Affiliated to Shandong University, Jiefang Street No. 27, Linyi, 276000, Shandong Province, China.
| | - Fengwei Zhang
- Department of Cardiovascular Surgery, Qilu Hospital of Shandong University, West Wenhua Road No.107, Lixia District, Jinan, 250012, Shandong Province, China
| |
Collapse
|
7
|
Vitarelli A. Patent Foramen Ovale: Pivotal Role of Transesophageal Echocardiography in the Indications for Closure, Assessment of Varying Anatomies and Post-procedure Follow-up. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:1882-1895. [PMID: 31104864 DOI: 10.1016/j.ultrasmedbio.2019.04.015] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2019] [Revised: 03/09/2019] [Accepted: 04/12/2019] [Indexed: 06/09/2023]
Abstract
Patent foramen ovale (PFO) is present in 15%-30% of the general population and has been associated with various pathologic states, including cryptogenic stroke, platypnea-orthodeoxia syndrome, decompression sickness and migraine with auras. Transesophageal echocardiography (TEE) has a major role in the diagnostic evaluation of PFO, as well as in the post-procedural assessment after transcatheter closure. The goals of this article were to synthesize the echocardiographic transesophageal techniques required for accurate PFO diagnosis and careful anatomic assessment of its anatomic variants, to focus TEE indications for device closure as complementary to clinical indications and to assess the role of TEE in the post-procedure follow-up.
Collapse
|
8
|
Snijder RJR, Renes LE, Suttorp MJ, Ten Berg JM, Post MC. Percutaneous patent foramen ovale closure using the Occlutech Figulla device: More than 1,300 patient-years of follow up. Catheter Cardiovasc Interv 2019; 93:1080-1084. [PMID: 30461175 DOI: 10.1002/ccd.27984] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/14/2018] [Revised: 10/22/2018] [Accepted: 10/29/2018] [Indexed: 11/07/2022]
Abstract
OBJECTIVE To evaluate the safety and efficacy of the Occlutech patent foramen ovale (PFO) device at long-term follow-up (FU). BACKGROUND The Occlutech device has been proven safe and effective six-months after percutaneous PFO closure. We describe the safety and efficacy after more than 1,300 patient-years of FU. METHODS All consecutive patients who underwent PFO closure between October 2008 and December 2015 were included. All complications were registered. Residual right-to-left shunt (RLS) was diagnosed using contrast transthoracic echocardiography and graded as minimal, moderate, or severe. RESULTS In total, 250 patients (mean age 53.5 ± 10.7 years, 46.8% female) underwent percutaneous PFO closure using the Occlutech device. Mean FU was 5.9 ± 1.8 years, a total of 1,345 patient-years. Transient ischemic attack (TIA) or stroke was the main indication for closure (89.6%). Implantation was successful in 100%, no major complications occurred. Minor complications were inguinal hematoma in 16 patients (6.4%), pericardial effusion without the need for intervention in one patient (0.4%) and a supraventricular tachycardia in one patient (0.4%). A moderate or large shunt at one-year follow up was present in 5.9%. A cerebrovascular vascular event occurred in 2.0% at 1-year FU (four TIA, one stroke) and in 7.4% at long-term FU (nine TIA, eight stroke). The total cerebrovascular event rate (TIA and CVA) was 0.02% per patient-year of FU, with a stroke rate of 0.01%. CONCLUSION The Occlutech device appears to be safe at long-term FU with a very low annual cerebrovascular event rate and a low moderate to large shunt rate at 1-year FU.
Collapse
Affiliation(s)
- Roel J R Snijder
- Department of Cardiology, St. Antonius Hospital, Nieuwegein, The Netherlands
| | - Laura E Renes
- Department of Emergency Medicine, St. Antonius Hospital, Nieuwegein, The Netherlands
| | - Maarten Jan Suttorp
- Department of Cardiology, St. Antonius Hospital, Nieuwegein, The Netherlands
| | - Jurrien M Ten Berg
- Department of Cardiology, St. Antonius Hospital, Nieuwegein, The Netherlands
| | - Martijn C Post
- Department of Cardiology, St. Antonius Hospital, Nieuwegein, The Netherlands
| |
Collapse
|
9
|
Alkhouli M, Sievert H, Holmes DR. Patent foramen ovale closure for secondary stroke prevention. Eur Heart J 2019; 40:2339-2350. [PMID: 30957864 DOI: 10.1093/eurheartj/ehz157] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/23/2018] [Revised: 10/30/2018] [Accepted: 03/05/2019] [Indexed: 01/10/2023] Open
Abstract
Abstract
Transcatheter closure of patent foramen ovale (PFO) in patients with cryptogenic stroke is gaining momentum after the recent publication of four randomized clinical trials suggesting its benefit. This article provides a contemporary overview of the anatomy and pathophysiology of PFO, the available diagnostic tools for the assessment and risk stratification of PFO, and the current and future landscape of PFO closure devices and their optimal utilization. It also summarizes the current data on PFO closure for stroke prevention, and discusses the remaining open issues in the field of PFO closure.
Collapse
Affiliation(s)
- Mohamad Alkhouli
- Division of Cardiology, School of Medicine, West Virginia University, 1 Medical Center Drive, Morgantown, WV, USA
| | - Horst Sievert
- Department of Medicine, CardioVascular Center Frankfurt, Seckbacher Landstraße 65, Frankfurt am Main, Germany
- Anglia Ruskin University, Cambridge Campus, East Rd, Cambridge, UK
- Yunnan Hospital Fuwai, Intersection of Shahe Beilu and Jinchuan Lu, Kunming, China
- University of California, 550 16th Street, San Francisco, CA, USA
| | - David R Holmes
- Department of Cardiology, Mayo Clinic School of Medicine, 200 1st St SW, Rochester, MN, USA
| |
Collapse
|
10
|
Pristipino C, Sievert H, D'Ascenzo F, Mas JL, Meier B, Scacciatella P, Hildick-Smith D, Gaita F, Toni D, Kyrle P, Thomson J, Derumeaux G, Onorato E, Sibbing D, Germonpré P, Berti S, Chessa M, Bedogni F, Dudek D, Hornung M, Zamorano J. European position paper on the management of patients with patent foramen ovale. General approach and left circulation thromboembolism. EUROINTERVENTION 2019; 14:1389-1402. [PMID: 30141306 DOI: 10.4244/eij-d-18-00622] [Citation(s) in RCA: 74] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 09/03/2023]
|
11
|
Kerut EK, Campbell WF, Hall ME, McMullan MR. Identification of candidates for PFO closure in the echocardiography laboratory. Echocardiography 2018; 35:1860-1867. [PMID: 30303254 DOI: 10.1111/echo.14154] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2018] [Revised: 08/21/2018] [Accepted: 09/14/2018] [Indexed: 01/16/2023] Open
Abstract
A patent foramen ovale (PFO) is implicated in several pathologic processes, including that of cryptogenic stroke (cCVA). Recent trials identify "high-risk" PFOs in patients with cCVA as likely to benefit from percutaneous closure. The younger the patient (<60 years old) the more likely a PFO may be attributable to the cCVA. The RoPE Score index helps determine the likelihood that an existing PFO is related to a cCVA. This may help guide the clinician and patient when contemplating percutaneous PFO closure. When evaluating a patient for possible percutaneous closure, one should identify the CVA as a typical ischemic type stroke. In order to "rule-out" other causes of CVA, imaging of the intracranial arteries, cervical, and aortic arch vessels should be performed. Small vessel disease or a lacunar-type infarct should be excluded. To rule out atrial fibrillation, prolonged monitoring should be performed. An index has been developed to determine the probability that a PFO is the causative etiology and calculates the risk of recurrence. This may help guide the clinician and patient in the decision for PFO closure. In addition, one should consider a work-up for a hypercoagulable state. We will obtain an ultrasound of the lower extremities or consider deep pelvic vein thrombosis (prolonged sitting or malignancy). If the closure is to be performed, the Food and Drug Administration (FDA) has approved the Amplatzer PFO Occluder and the GORE Cardioform Septal Occluder for percutaneous closure. These devices are both approved in patients predominately between ages 18 and 60 years with a cCVA due to presumed paradoxical embolism as verified by a neurologist and cardiologist and when other causes of ischemic CVA have been excluded. "High-risk" PFOs appear to achieve the most potential benefit from percutaneous closure.
Collapse
Affiliation(s)
- Edmund Kenneth Kerut
- Division of Cardiovascular Diseases, Department of Medicine, University of Mississippi School of Medicine, Jackson, Mississippi.,Heart Clinic of Louisiana, Marrero, Louisiana
| | - William F Campbell
- Division of Cardiovascular Diseases, Department of Medicine, University of Mississippi School of Medicine, Jackson, Mississippi
| | - Michael E Hall
- Division of Cardiovascular Diseases, Department of Medicine, University of Mississippi School of Medicine, Jackson, Mississippi
| | - Michael R McMullan
- Division of Cardiovascular Diseases, Department of Medicine, University of Mississippi School of Medicine, Jackson, Mississippi
| |
Collapse
|
12
|
Carroll JD. A Positive Bubble Test Post-Patent Foramen Ovale Closure: Was Satisfaction-of-Search to Blame? JACC Cardiovasc Interv 2018; 11:1105-1107. [PMID: 29880107 DOI: 10.1016/j.jcin.2018.04.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/27/2018] [Accepted: 04/03/2018] [Indexed: 11/25/2022]
Affiliation(s)
- John D Carroll
- University of Colorado School of Medicine, Aurora, Colorado.
| |
Collapse
|