1
|
Bezzeccheri A, Poletti E, Vermeersch P, Veulemans V, Piuhola J, Kerkelä S, Lehtola H, De Backer O, Quagliana A, Mammone C, Ribichini F, Prihadi E, Scott B, Zivelonghi C, Verheye S, Agostoni P. Prosthesis Infolding Incidence and Short-Term Outcomes in Transcatheter Aortic Valve Implantation Using Evolut Self-Expandable Device: A Multicenter Study. Am J Cardiol 2024; 221:102-109. [PMID: 38636623 DOI: 10.1016/j.amjcard.2024.04.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/03/2024] [Revised: 03/03/2024] [Accepted: 04/13/2024] [Indexed: 04/20/2024]
Abstract
Transcatheter aortic valve implantation (TAVI) is an established treatment strategy in aortic valve disease. Infolding, as a nonuniform expansion of the prosthesis leading to introflection of part of the device circumference, is a complication specific to self-expandable prostheses. The aim of the study is to determine incidence, predictors, treatment strategy, and outcomes of infolding during Medtronic Evolut TAVI (Minneapolis, MN, US). Between January 2018 and March 2022, all patients treated with Evolut TAVI were included in a multicenter observational retrospective study. According to the occurrence of infolding, the enrolled cohort was divided into 2 groups; periprocedural characteristics and 30-day outcomes were compared. A total of 1,470 patients were included; 23 infolding cases (1.6%) were detected. Preprocedural imaging showed larger aortic anatomy and greater calcium burden in the infolding group. Infolding occurred mostly with Evolut Pro+ and size 34 mm and was diagnosed before full prosthesis release in 78.3%. The rate of moderate-to-severe paravalvular regurgitation was higher in the infolding group (21.7% vs 1.9%, p <0.001). Short-term follow-up showed greater all-cause and cardiovascular mortality (respectively, 4.3% vs 0.7% and 4.3% vs 0.6%, p <0.05) and higher rate of pacemaker implantation (33.3% vs 15.7%, p = 0.042) in case of infolding. High right cusp calcium score and resheathing maneuvers were independent predictors of infolding. In conclusion, prosthesis infolding is a TAVI complication burdened by worse cardiovascular outcomes. Prompt intraprocedural infolding diagnosis is pivotal, especially in case of great native valve calcium burden and resheathing maneuvers, to safely overcome this complication by prosthesis recapture or postdilation.
Collapse
Affiliation(s)
- Andrea Bezzeccheri
- HartCentrum, Ziekenhuis Netwerk Antwerpen (ZNA) Middelheim, Antwerp, Belgium; Department of Experimental Medicine, University of Rome "Tor Vergata", Rome, Italy
| | - Enrico Poletti
- HartCentrum, Ziekenhuis Netwerk Antwerpen (ZNA) Middelheim, Antwerp, Belgium
| | - Paul Vermeersch
- HartCentrum, Ziekenhuis Netwerk Antwerpen (ZNA) Middelheim, Antwerp, Belgium
| | - Verena Veulemans
- Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich-Heine-Universität, Dusseldorf, Germany
| | - Jarkko Piuhola
- Department of Cardiology, Oulu University Hospital, Oulu, Finland
| | - Seija Kerkelä
- Department of Cardiology, Oulu University Hospital, Oulu, Finland
| | - Heidi Lehtola
- Department of Cardiology, Oulu University Hospital, Oulu, Finland
| | - Ole De Backer
- The Heart Center, Rigshospitalet Copenhagen University Hospital, Copenhagen, Denmark
| | - Angelo Quagliana
- The Heart Center, Rigshospitalet Copenhagen University Hospital, Copenhagen, Denmark
| | - Concetta Mammone
- Division of Cardiology, Cardio-Thoracic Department, University Hospital of Verona, Verona, Italy
| | - Flavio Ribichini
- Division of Cardiology, Cardio-Thoracic Department, University Hospital of Verona, Verona, Italy
| | - Edgard Prihadi
- HartCentrum, Ziekenhuis Netwerk Antwerpen (ZNA) Middelheim, Antwerp, Belgium
| | - Benjamin Scott
- HartCentrum, Ziekenhuis Netwerk Antwerpen (ZNA) Middelheim, Antwerp, Belgium
| | - Carlo Zivelonghi
- HartCentrum, Ziekenhuis Netwerk Antwerpen (ZNA) Middelheim, Antwerp, Belgium
| | - Stefan Verheye
- HartCentrum, Ziekenhuis Netwerk Antwerpen (ZNA) Middelheim, Antwerp, Belgium
| | | |
Collapse
|
2
|
Tosaka K, Ninomiya R, Fusazaki T, Morino Y. Infolding of Evolut PRO+ during transcatheter aortic valve implantation and bailout by post-balloon dilation: A case report. J Cardiol Cases 2024; 29:190-192. [PMID: 38646073 PMCID: PMC11031665 DOI: 10.1016/j.jccase.2023.12.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Revised: 12/25/2023] [Accepted: 12/26/2023] [Indexed: 04/23/2024] Open
Abstract
An 89-year-old man with symptomatic severe aortic stenosis underwent transcatheter aortic valve implantation due to old age and a history of coronary artery bypass grafting. Computed tomography showed a tricuspid aortic valve and severe calcification at the aortic valve annulus, with a perimeter of 88.7 mm. The 34-mm Evolut PRO+ (Medtronic Inc., Minneapolis, MN, USA) was selected. After balloon aortic valvuloplasty, deployment of the Evolut PRO+ was attempted, but significant expansion failure was observed. Upon retraction and removal of the Evolut PRO+ from the body, frame deformation was observed. A new Evolut PRO+ was tried again, but a similar finding was noted as a magatama-like infolding on transesophageal echocardiography. Fortunately, the patient's hemodynamics were relatively stable. Post-dilation was performed using a 25 mm Z-MED II (NuMED, Inc., Montreal, Canada) for reshaping. Learning objective In self-expanding transcatheter aortic valves (TAVs), bending of the TAV frame is widely known as one of the key problems. However, this is rare and infrequently encountered. In this case, TAV frame infolding occurred repeatedly, and the morphology of the infolding was evaluated in vitro and in vivo. Furthermore, we report that some TAVs can be reshaped by post-dilation.
Collapse
Affiliation(s)
- Kengo Tosaka
- Division of Cardiology, Department of Internal Medicine, Iwate Medical University, Iwate, Japan
| | - Ryo Ninomiya
- Division of Cardiology, Department of Internal Medicine, Iwate Medical University, Iwate, Japan
| | - Tetsuya Fusazaki
- Division of Cardiology, Department of Internal Medicine, Iwate Medical University, Iwate, Japan
| | - Yoshihiro Morino
- Division of Cardiology, Department of Internal Medicine, Iwate Medical University, Iwate, Japan
| |
Collapse
|
3
|
Ancona MB, Beneduce A, Romano V, Buzzatti N, Russo F, Bellini B, Ferri LA, Agricola E, Landoni G, Scandroglio AM, Chieffo A, Montorfano M. Self-expanding transcatheter aortic valve infolding: Current evidence, diagnosis, and management. Catheter Cardiovasc Interv 2020; 98:E299-E305. [PMID: 33315300 DOI: 10.1002/ccd.29432] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/21/2020] [Revised: 11/10/2020] [Accepted: 11/30/2020] [Indexed: 12/28/2022]
Abstract
BACKGROUND Prosthetic valve infolding is a rare but severe complication of transcatheter aortic valve implantation (TAVI) with self-expanding valves. However, currently available clinical data are limited and fragmented. OBJECTIVES This report aims to provide a comprehensive overview of this complication focusing on predisposing factors, clinical presentation, diagnostic findings, treatment and clinical outcomes. METHODS A systematic review of the literature was performed to identify cases of infolding occurring during TAVI with self-expanding valves published until August 2020. These data were pooled with all the retrospectively identified infolding cases occurred at San Raffaele Scientific Institute between December 2014 and August 2020. RESULTS A total of 34 cases were included. Among patients with available data, 38% received a first-generation CoreValve, and 62% a second-generation Evolut R (82%) or Evolut PRO (18%). Infolding occurred mostly with ≥29-mm valves (94%). Predisposing factors included resheathing of a second-generation valve (82%), heavy calcification of the native valve (65%), lack of predilatation (16%), Sievers type-1 bicuspid aortic valve (11%), and improper valve loading (5%). Infolding resulted in severe PVL causing hemodynamic instability (29%) or cardiac arrest (12%). Postdilatation was the treatment strategy in 68%, while prosthesis replacement with a new device in 23% of cases. Device success rate was 82%. Death and stroke occurred in 3% and 12% of cases. CONCLUSIONS Prosthetic valve infolding is typically observed after resheathing of a large-size self-expanding TAVI. When infolding is timely diagnosed, prosthesis removal and replacement should be pursued. Further studies are required to precisely define predisposing factors to prevent this complication.
Collapse
Affiliation(s)
- Marco Bruno Ancona
- Interventional Cardiology Unit, IRCCS San Raffaele Scientific Institute, Milan, Italy
| | - Alessandro Beneduce
- Interventional Cardiology Unit, IRCCS San Raffaele Scientific Institute, Milan, Italy
| | - Vittorio Romano
- Interventional Cardiology Unit, IRCCS San Raffaele Scientific Institute, Milan, Italy
| | - Nicola Buzzatti
- Cardiac Surgery Unit, IRCCS San Raffaele Scientific Institute, Milan, Italy
| | - Filippo Russo
- Interventional Cardiology Unit, IRCCS San Raffaele Scientific Institute, Milan, Italy
| | - Barbara Bellini
- Interventional Cardiology Unit, IRCCS San Raffaele Scientific Institute, Milan, Italy
| | - Luca Angelo Ferri
- Interventional Cardiology Unit, IRCCS San Raffaele Scientific Institute, Milan, Italy
| | - Eustachio Agricola
- Echocardiography Unit, IRCCS San Raffaele Scientific Institute, Milan, Italy
| | - Giovanni Landoni
- Anesthesia and Intensive Care Department, IRCCS San Raffaele Scientific Institute, Milan, Italy
| | - Anna Mara Scandroglio
- Anesthesia and Intensive Care Department, IRCCS San Raffaele Scientific Institute, Milan, Italy
| | - Alaide Chieffo
- Interventional Cardiology Unit, IRCCS San Raffaele Scientific Institute, Milan, Italy
| | - Matteo Montorfano
- Interventional Cardiology Unit, IRCCS San Raffaele Scientific Institute, Milan, Italy
| |
Collapse
|
4
|
Karrowni W, Fakih S, Nassar P. Infolding of Self-Expandable Transcatheter Heart Valve: Case Report and Review of Literature. Cureus 2020; 12:e10093. [PMID: 33005514 PMCID: PMC7522173 DOI: 10.7759/cureus.10093] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022] Open
Abstract
Transcutaneous aortic valve replacement (TAVR) has become a widely accepted minimally invasive approach for treatment of severe aortic stenosis. Self-expandable prostheses are commonly the device of choice, with excellent procedural success and durability. However, there have been several recent case reports of infolding of the self-expandable prosthesis during development with subsequent malfunction and need for further intervention. We present a case of self-expandable valve prosthesis infolding managed by balloon postdilation, and summarize the cases reported in the literature to date in an attempt to increase awareness of this serious technical problem and the factors associated with it.
Collapse
|
5
|
Kim MC, Kim JH, Cho KH, Sim DS, Hong YJ, Ahn Y, Jeong MH. Infolding Distortion of Evolut R Valve after Transcatheter Aortic Valve Replacement. Korean Circ J 2020; 50:539-541. [PMID: 32096360 PMCID: PMC7234842 DOI: 10.4070/kcj.2019.0406] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2019] [Accepted: 12/27/2019] [Indexed: 11/11/2022] Open
Affiliation(s)
- Min Chul Kim
- Division of Cardiology, Department of Internal Medicine, Chonnam National University Hospital, Gwangju, Korea
| | - Ju Han Kim
- Division of Cardiology, Department of Internal Medicine, Chonnam National University Hospital, Gwangju, Korea.
| | - Kyung Hoon Cho
- Division of Cardiology, Department of Internal Medicine, Chonnam National University Hospital, Gwangju, Korea
| | - Doo Sun Sim
- Division of Cardiology, Department of Internal Medicine, Chonnam National University Hospital, Gwangju, Korea
| | - Young Joon Hong
- Division of Cardiology, Department of Internal Medicine, Chonnam National University Hospital, Gwangju, Korea
| | - Youngkeun Ahn
- Division of Cardiology, Department of Internal Medicine, Chonnam National University Hospital, Gwangju, Korea
| | - Myung Ho Jeong
- Division of Cardiology, Department of Internal Medicine, Chonnam National University Hospital, Gwangju, Korea
| |
Collapse
|
6
|
Kagase A, Yamamoto M, Nishio H, Tsujimoto S. Importance of Rotational Angiography Before Complete Release of Self-Expandable Transcatheter Bioprosthesis for Detecting Valve Infolding Phenomenon. JACC Cardiovasc Interv 2019; 12:e83-e84. [DOI: 10.1016/j.jcin.2019.02.030] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/18/2018] [Revised: 02/06/2019] [Accepted: 02/19/2019] [Indexed: 11/16/2022]
|