Sava RI, Garot P, Benamer H, Gall E, Pezel T, Djebbar M, Sayah N, Meier D, Tzimas G, Garot J, Leclercq F, Akodad M. Redo-Transcatheter Aortic Valve Replacement Procedural Optimization and Patient Selection: From Bench to Clinical Practice. J Clin Med 2025; 14:2770. [PMID: 40283600 PMCID: PMC12027932 DOI: 10.3390/jcm14082770] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2025] [Revised: 04/10/2025] [Accepted: 04/11/2025] [Indexed: 04/29/2025] Open
Abstract
With recent guidelines expanding transcatheter aortic valve replacement (TAVR) to younger patients, indications for redo-TAVR will also likely increase. When compared with TAVR, redo-TAVR is a rare and novel procedure. Current clinical data derived from registries suggest excellent safety, with low rates of 30-day and 1-year mortality following redo-TAVR. Proper understanding of data from bench studies regarding optimal valve configurations, of patient anatomy and of the technical properties of transcatheter heart valves (THV) is essential for patient selection and procedural success. Lifetime management of redo-TAVR should start before the index procedure, as the choice of the index THV has a major impact on the feasibility of redo-TAVR. Procedural optimization by adequate valve sizing, commissural alignment and adequate implant depth of both index and redo-THV are critical determinants of optimal hemodynamics for maximized valve longevity, as well as lifelong coronary access.
Collapse
Affiliation(s)
- Ruxandra I. Sava
- Institut Cardiovasculaire Paris Sud, Hôpital Privé Jacques Cartier, Ramsay Santé, 91300 Massy, France; (R.I.S.); (P.G.); (H.B.); (E.G.); (M.D.); (N.S.); (J.G.)
| | - Philippe Garot
- Institut Cardiovasculaire Paris Sud, Hôpital Privé Jacques Cartier, Ramsay Santé, 91300 Massy, France; (R.I.S.); (P.G.); (H.B.); (E.G.); (M.D.); (N.S.); (J.G.)
| | - Hakim Benamer
- Institut Cardiovasculaire Paris Sud, Hôpital Privé Jacques Cartier, Ramsay Santé, 91300 Massy, France; (R.I.S.); (P.G.); (H.B.); (E.G.); (M.D.); (N.S.); (J.G.)
| | - Emmanuel Gall
- Institut Cardiovasculaire Paris Sud, Hôpital Privé Jacques Cartier, Ramsay Santé, 91300 Massy, France; (R.I.S.); (P.G.); (H.B.); (E.G.); (M.D.); (N.S.); (J.G.)
- Department of Cardiology, University Hospital of Lariboisiere, (Assistance Publique des Hôpitaux de Paris, AP-HP), Université Paris-Cité, 75013 Paris, France;
| | - Théo Pezel
- Department of Cardiology, University Hospital of Lariboisiere, (Assistance Publique des Hôpitaux de Paris, AP-HP), Université Paris-Cité, 75013 Paris, France;
| | - Morad Djebbar
- Institut Cardiovasculaire Paris Sud, Hôpital Privé Jacques Cartier, Ramsay Santé, 91300 Massy, France; (R.I.S.); (P.G.); (H.B.); (E.G.); (M.D.); (N.S.); (J.G.)
| | - Neila Sayah
- Institut Cardiovasculaire Paris Sud, Hôpital Privé Jacques Cartier, Ramsay Santé, 91300 Massy, France; (R.I.S.); (P.G.); (H.B.); (E.G.); (M.D.); (N.S.); (J.G.)
| | - David Meier
- Department of Cardiology, Lausanne University Hospital and University of Lausanne, 1005 Lausanne, Switzerland; (D.M.); (G.T.)
| | - Georgios Tzimas
- Department of Cardiology, Lausanne University Hospital and University of Lausanne, 1005 Lausanne, Switzerland; (D.M.); (G.T.)
| | - Jérôme Garot
- Institut Cardiovasculaire Paris Sud, Hôpital Privé Jacques Cartier, Ramsay Santé, 91300 Massy, France; (R.I.S.); (P.G.); (H.B.); (E.G.); (M.D.); (N.S.); (J.G.)
| | | | - Mariama Akodad
- Institut Cardiovasculaire Paris Sud, Hôpital Privé Jacques Cartier, Ramsay Santé, 91300 Massy, France; (R.I.S.); (P.G.); (H.B.); (E.G.); (M.D.); (N.S.); (J.G.)
| |
Collapse
|
2
|
Paredes-Vazquez JG, Tirado-Conte G, Shabbir A, Mon-Noboa M, Chavez JF, Nuñez-Gil I, Jimenez-Quevedo P, Pozo-Osinalde E, Gomez de Diego JJ, Salinas P, Mejia-Renteria H, Macaya F, de Agustin-Loeches JA, Gonzalo N, Escaned J, Fernandez-Ortiz A, Nombela-Franco L. The Incidence, Impact, and Techniques of Commissural Alignment in Transcatheter Aortic Valve Implantation: A Review. J Clin Med 2023; 12:7369. [PMID: 38068420 PMCID: PMC10707706 DOI: 10.3390/jcm12237369] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2023] [Revised: 11/20/2023] [Accepted: 11/21/2023] [Indexed: 10/16/2024] Open
Abstract
In current clinical practice, commissural alignment of the transcatheter heart valve (THV) during transcatheter aortic valve implantation (TAVI) is seldom achieved. Orientation of the THV within the aortic root and the subsequent influence upon leaflet haemodynamic function, coronary blood flow, and ease of access to the coronary ostia are gaining significant interest. Herein, we review the incidence and clinical implications of commissural misalignment in TAVI and offer thorough descriptions of how optimal alignment can be achieved with several different contemporary THV devices.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | - Luis Nombela-Franco
- Cardiovascular Institute, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), 28040 Madrid, Spain; (J.G.P.-V.)
| |
Collapse
|
3
|
Eckel CE, Kim WK, Grothusen C, Tiyerili V, Elsässer A, Sötemann D, Schlüter J, Choi YH, Charitos EI, Renker M, Hamm CW, Dohmen G, Möllmann H, Blumenstein J. Comparison of the New-Generation Self-Expanding NAVITOR Transcatheter Heart Valve with Its Predecessor, the PORTICO, in Severe Native Aortic Valve Stenosis. J Clin Med 2023; 12:3999. [PMID: 37373693 DOI: 10.3390/jcm12123999] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 06/08/2023] [Accepted: 06/09/2023] [Indexed: 06/29/2023] Open
Abstract
BACKGROUND Third-generation transcatheter heart valves (THVs) are designed to improve outcomes. Data on the new intra-annular self-expanding NAVITOR are scarce. AIMS The aim of this analysis was to compare outcomes between the PORTICO and the NAVITOR systems. METHODS Data from 782 patients with severe native aortic stenosis treated with PORTICO (n = 645) or NAVITOR (n = 137) from 05/2012 to 09/2022 were evaluated. The clinical and hemodynamic outcomes of 276 patients (PORTICO, n = 139; NAVITOR, n = 137) were evaluated according to VARC-3 recommendations. RESULTS Rates of postprocedural more-than-mild paravalvular leakage (PVL) were significantly lower for NAVITOR than for PORTICO (7.2% vs. 1.5%, p = 0.041). In addition, severe bleeding rates (27.3% vs. 13.1%, p = 0.005) and major vascular complications (5.8% vs. 0.7%, p = 0.036) were lower in the NAVITOR group. The mean gradients (7 vs. 8 mmHg, p = 0.121) and calculated aortic valve areas (1.90 cm2 vs. 1.99 cm2, p = 0.235) were comparable. Rates of PPI were similarly high in both groups (15.3 vs. 21.6, p = 0.299). CONCLUSIONS The NAVITOR demonstrated favorable in-hospital procedural outcome data, with lower rates of relevant PVL, major vascular complications, and severe bleeding than its predecessor the PORTICO and preserved favorable hemodynamic outcomes.
Collapse
Affiliation(s)
- Clemens Enno Eckel
- Department of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany
- Department of Cardiology, University of Oldenburg, 26129 Oldenburg, Germany
| | - Won-Keun Kim
- Department of Cardiac Surgery, Kerckhoff Heart Center, 61231 Bad Nauheim, Germany
- Department of Cardiology, Kerckhoff Heart Center, 61231 Bad Nauheim, Germany
| | - Christina Grothusen
- Department of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany
- Department of Cardiac and Vascular Surgery, University of Kiel, 24098 Kiel, Germany
| | - Vedat Tiyerili
- Department of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany
| | - Albrecht Elsässer
- Department of Cardiology, University of Oldenburg, 26129 Oldenburg, Germany
| | - Dagmar Sötemann
- Department of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany
| | - Judith Schlüter
- Department of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany
- Department of Cardiology, University of Oldenburg, 26129 Oldenburg, Germany
| | - Yeong-Hoon Choi
- Department of Cardiac Surgery, Kerckhoff Heart Center, 61231 Bad Nauheim, Germany
| | | | - Matthias Renker
- Department of Cardiology, Kerckhoff Heart Center, 61231 Bad Nauheim, Germany
- German Center for Cardiovascular Research (DZHK), Partner Site Rhine-Main, 55131 Bad Nauheim, Germany
| | - Christian W Hamm
- German Center for Cardiovascular Research (DZHK), Partner Site Rhine-Main, 55131 Bad Nauheim, Germany
- Department of Cardiology, University of Giessen, 35390 Giessen, Germany
| | - Guido Dohmen
- Department of Cardiac Surgery, St. Johannes Hospital, 44137 Dortmund, Germany
| | - Helge Möllmann
- Department of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany
| | - Johannes Blumenstein
- Department of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany
- Department of Cardiology, University of Oldenburg, 26129 Oldenburg, Germany
| |
Collapse
|
4
|
Quagliana A, Montarello NJ, Willemen Y, Bække PS, Jørgensen TH, De Backer O, Sondergaard L. Commissural Alignment and Coronary Access after Transcatheter Aortic Valve Replacement. J Clin Med 2023; 12:jcm12062136. [PMID: 36983139 PMCID: PMC10056242 DOI: 10.3390/jcm12062136] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2023] [Revised: 03/06/2023] [Accepted: 03/07/2023] [Indexed: 03/11/2023] Open
Abstract
Transcatheter aortic valve implantation (TAVR) is the first therapeutic option for elderly patients with severe symptomatic aortic stenosis, and indications are steadily expanding to younger patients and subjects with lower surgical risk and longer life expectancy. Commissural alignment between native and transcatheter valves facilitates coronary access after TAVR and is thus considered a procedural goal, allowing long-term management of coronary artery disease. Moreover, commissural alignment may potentially have a positive impact on transvalvular hemodynamic and valve durability. This review focus on technical hints to achieve commissural alignment and current evidence for different transcatheter aortic valves.
Collapse
Affiliation(s)
- Angelo Quagliana
- The Heart Center, Rigshospitalet, Copenhagen University Hospital, 2100 Copenhagen, Denmark
- Cardiocentro Ticino Institute—EOC, Universita’della Svizzera Italiana, 6900 Lugano, Switzerland
| | - Nicholas J. Montarello
- The Heart Center, Rigshospitalet, Copenhagen University Hospital, 2100 Copenhagen, Denmark
| | - Yannick Willemen
- The Heart Center, Rigshospitalet, Copenhagen University Hospital, 2100 Copenhagen, Denmark
| | - Pernille S. Bække
- The Heart Center, Rigshospitalet, Copenhagen University Hospital, 2100 Copenhagen, Denmark
| | - Troels H. Jørgensen
- The Heart Center, Rigshospitalet, Copenhagen University Hospital, 2100 Copenhagen, Denmark
| | - Ole De Backer
- The Heart Center, Rigshospitalet, Copenhagen University Hospital, 2100 Copenhagen, Denmark
| | - Lars Sondergaard
- The Heart Center, Rigshospitalet, Copenhagen University Hospital, 2100 Copenhagen, Denmark
- Correspondence:
| |
Collapse
|
5
|
Akodad M, Lounes Y, Meier D, Sanguineti F, Hovasse T, Blanke P, Sathananthan J, Tzimas G, Leipsic J, Wood DA, Webb J, Chevalier B. Transcatheter heart valve commissural alignment: an updated review. Front Cardiovasc Med 2023; 10:1154556. [PMID: 37153454 PMCID: PMC10155866 DOI: 10.3389/fcvm.2023.1154556] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Accepted: 03/28/2023] [Indexed: 05/09/2023] Open
Abstract
Transcatheter aortic valve replacement (TAVR) indications recently extended to lower surgical risk patients with longer life expectancy. Commissural alignment (CA) is one of the emerging concepts and is becoming one of the cornerstones of the TAVR procedure in a patient with increased longevity. Indeed, CA may improve transcatheter heart valve (THV) hemodynamics, future coronary access, and repeatability. The definition of CA has been recently standardized by the ALIGN-TAVR consortium using a four-tier scale based on CT analysis. Progress has been made during the index TAVR procedure to optimize CA, especially with self-expandable platforms. Indeed, specific delivery catheter orientation, THV rotation, and computed-tomography-derived views have been proposed to achieve a reasonable degree of CA. Recent data demonstrate feasibility, safety, and a significant reduction in coronary overlap using these techniques, especially with self-expandable platforms. This review provides an overview of THV CA including assessment methods, alignment techniques during the index TAVR procedure with different THV platforms, the clinical impact of commissural misalignment, and challenging situations for CA.
Collapse
Affiliation(s)
- Mariama Akodad
- Ramsay Générale de Santé, Institut Cardiovasculaire Paris Sud, Interventional Cardiology Department, Massy, France
- Correspondence: Mariama Akodad
| | - Youcef Lounes
- Ramsay Générale de Santé, Institut Cardiovasculaire Paris Sud, Vascular Surgery Department, Massy, France
| | - David Meier
- Division of Cardiology and Department of Radiology, Centresfor Heart Valve Innovation and for Cardiovascular Innovation, St Paul’s and Vancouver General Hospitals, University of British Columbia, Vancouver, BC, Canada
| | - Francesca Sanguineti
- Ramsay Générale de Santé, Institut Cardiovasculaire Paris Sud, Interventional Cardiology Department, Massy, France
| | - Thomas Hovasse
- Ramsay Générale de Santé, Institut Cardiovasculaire Paris Sud, Interventional Cardiology Department, Massy, France
| | - Philipp Blanke
- Division of Cardiology and Department of Radiology, Centresfor Heart Valve Innovation and for Cardiovascular Innovation, St Paul’s and Vancouver General Hospitals, University of British Columbia, Vancouver, BC, Canada
| | - Janarthanan Sathananthan
- Division of Cardiology and Department of Radiology, Centresfor Heart Valve Innovation and for Cardiovascular Innovation, St Paul’s and Vancouver General Hospitals, University of British Columbia, Vancouver, BC, Canada
| | - Georgios Tzimas
- Division of Cardiology and Department of Radiology, Centresfor Heart Valve Innovation and for Cardiovascular Innovation, St Paul’s and Vancouver General Hospitals, University of British Columbia, Vancouver, BC, Canada
| | - Jonathon Leipsic
- Division of Cardiology and Department of Radiology, Centresfor Heart Valve Innovation and for Cardiovascular Innovation, St Paul’s and Vancouver General Hospitals, University of British Columbia, Vancouver, BC, Canada
| | - David A. Wood
- Division of Cardiology and Department of Radiology, Centresfor Heart Valve Innovation and for Cardiovascular Innovation, St Paul’s and Vancouver General Hospitals, University of British Columbia, Vancouver, BC, Canada
| | - John Webb
- Division of Cardiology and Department of Radiology, Centresfor Heart Valve Innovation and for Cardiovascular Innovation, St Paul’s and Vancouver General Hospitals, University of British Columbia, Vancouver, BC, Canada
| | - Bernard Chevalier
- Ramsay Générale de Santé, Institut Cardiovasculaire Paris Sud, Interventional Cardiology Department, Massy, France
| |
Collapse
|
6
|
Quantification of Commissural Alignment of Balloon-Expandable THV on Fluoroscopy: A Comparison Study With Post-TAVR CT. JACC Cardiovasc Interv 2022; 15:2374-2383. [PMID: 36480984 DOI: 10.1016/j.jcin.2022.08.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/19/2022] [Revised: 07/22/2022] [Accepted: 08/04/2022] [Indexed: 01/11/2023]
Abstract
BACKGROUND Coronary access may be challenging following transcatheter aortic valve replacement (TAVR) in the setting of transcatheter heart valve (THV) commissural misalignment. OBJECTIVES The authors aimed to quantify the degree of commissural alignment following balloon-expandable THV implantation using a fluoroscopy-based trigonometric approach and assess its correlation with post-TAVR computed tomography (CT). METHODS Twenty patients who had undergone both TAVR with the balloon-expandable SAPIEN 3 THV and post-TAVR CT were included in the analysis. Optimized, predeployment 3-cusp angiographic view and postdeployment angiographic view using identical fluoroscopic projections were required. The distance between the most central posterior commissural strut and the THV centerline was assessed. Commissural alignment was calculated by means of a trigonometrical approach using an arcsine function, assuming circular deployment of the THV. Commissural alignment was stratified using a 4-tier scale: aligned (0° to 15°); mildly misaligned (15° to 30°); moderately misaligned (30° to 45°), and severely misaligned (45° to 60°). RESULTS Seven patients (35.0%) were misclassified by 1 tier, and no patient was misclassified by 2 or more tiers, with strong agreement between CT and fluoroscopy (weighted Cohen's kappa coefficient = 0.724). Correlation of the commissural offset angle determined from fluoroscopy and CT was excellent (r = 0.986; 95% CI: 0.965 to 0.995). Bland-Altman analysis demonstrated a strong agreement between both modalities with a mean difference of 0.5° (95% limits of agreement: -12.7° to 13.7°). CONCLUSIONS The degree of commissural alignment of the balloon-expandable THV can be reliably assessed and quantified on postdeployment fluoroscopy using a standardized 3-cusp view and trigonometry-based analysis.
Collapse
|
7
|
Kapadia SR, Harb SC, Krishnaswamy A. Fluoroscopic Determination of Commissural Alignment for TAVR Valves. JACC Cardiovasc Interv 2022; 15:2384-2386. [PMID: 36121438 DOI: 10.1016/j.jcin.2022.08.050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Accepted: 08/30/2022] [Indexed: 01/11/2023]
Affiliation(s)
- Samir R Kapadia
- Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA.
| | - Serge C Harb
- Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Amar Krishnaswamy
- Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA
| |
Collapse
|
8
|
Kumar A, Reed GW, Puri R, Krishnaswamy A, Kapadia S. TAVR in the Low Risk Era: One Size Doesn't Fit All. Prog Cardiovasc Dis 2022; 72:93-95. [PMID: 35654171 DOI: 10.1016/j.pcad.2022.05.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Anirudh Kumar
- Heart and Vascular Institute, Cleveland Clinic, Cleveland, Ohio.
| | - Grant W Reed
- Heart and Vascular Institute, Cleveland Clinic, Cleveland, Ohio
| | - Rishi Puri
- Heart and Vascular Institute, Cleveland Clinic, Cleveland, Ohio
| | | | - Samir Kapadia
- Heart and Vascular Institute, Cleveland Clinic, Cleveland, Ohio
| |
Collapse
|