1
|
Navratilova P, Emmer J, Tomas T, Ryba L, Burda J, Loja T, Veverkova J, Valkova L, Pavkova Goldbergova M. Plastic response of macrophages to metal ions and nanoparticles in time mimicking metal implant body environment. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2024; 31:4111-4129. [PMID: 38097843 DOI: 10.1007/s11356-023-31430-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Accepted: 12/05/2023] [Indexed: 01/19/2024]
Abstract
The paradigm of using metal biomaterials could be viewed from two sides - treatment of wide spectrum of degenerative diseases, and debris release from materials. After implant insertion, metal nanoparticles (NPs) and ions are released not only upon the first contact with cells/tissues, but in continual manner, which is immediately recognized by immune cells. In this work, the effects of metal nanoparticles (TiO2, Ni) and ions (Ni2+, Co2+, Cr3+, Mo6+) on primary human M0 macrophages from the blood samples of osteoarthritic patients undergoing total arthroplasty were studied in order to monitor immunomodulatory effects on the cells in a real-time format. The highest NiNPs concentration of 10 µg/ml had no effect on any of macrophage parameters, while the Ni2+ ions cytotoxicity limit for the cells is 0.5 mM. The cytotoxic effects of higher Ni2+ concentration revealed mitochondrial network fragmentation leading to mitochondrial dysfunction, accompanied by increased lysosomal activity and changes in pro-apoptotic markers. The suppression of M2 cell formation ability was connected to presence of Ni2+ ions (0.5 mM) and TiO2NPs (10 µg/ml). The immunomodulatory effect of Mo6+ ions, controversially, inhibit the formation of the cells with M1 phenotype and potentiate the thread-like shape M2s with increased chaotic cell movement. To summarize, metal toxicity depends on the debris form. Both, metal ions and nanoparticles affect macrophage size, morphological and functional parameters, but the effect of ions is more complex and likely more harmful, which has potential impact on healing and determines post-implantation reactions.
Collapse
Affiliation(s)
- Polina Navratilova
- Department of Pathophysiology, Masaryk University, Kamenice 5, Brno, Czech Republic
| | - Jan Emmer
- 1st Department of Orthopaedics, St. Anne's University Hospital, Pekarska 53, Brno, Czech Republic
| | - Tomas Tomas
- 1st Department of Orthopaedics, St. Anne's University Hospital, Pekarska 53, Brno, Czech Republic.
| | - Ludek Ryba
- Department of Orthopaedic Surgery, University Hospital, Jihlavska 20, Brno, Czech Republic
| | - Jan Burda
- Department of Orthopaedic Surgery, University Hospital, Jihlavska 20, Brno, Czech Republic
| | - Tomas Loja
- Centre for Molecular Medicine, Central European Institute of Technology/Masaryk University, Kamenice 5, Brno, Czech Republic
| | - Jana Veverkova
- Department of Pathophysiology, Masaryk University, Kamenice 5, Brno, Czech Republic
| | - Lucie Valkova
- Department of Pathophysiology, Masaryk University, Kamenice 5, Brno, Czech Republic
| | | |
Collapse
|
2
|
Cheng KY, Gupta P, Kanniyappan H, Zahurullah H, Sun Y, Alhamad M, Mathew MT. Survivability of Titanium Implant Materials: In Vitro Simulated Inflammatory and Infectious Environment. Ann Biomed Eng 2023; 51:2749-2761. [PMID: 37530907 PMCID: PMC10834857 DOI: 10.1007/s10439-023-03330-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Accepted: 07/22/2023] [Indexed: 08/03/2023]
Abstract
Titanium-based implants utilized in total joint arthroplasties could restore primary musculoskeletal function to patients suffering from osteoarthritis and other conditions. Implants are susceptible to failure stemming from aseptic loosening and infection at the joint site, eventually requiring revision surgery. We hypothesized that there might be a feedback loop by which metal degradation particles and ions released from the implant decrease cell viability and increase immune response, thereby creating biochemical conditions that increase the corrosion rate and release more metal ions. This study focused on the synergistic process through cell viability assays and electrochemical tests. From the results, inflammatory conditions from ion release resulting in cell death would further increase the corrosion rate at the metal implant site. The synergistic interaction in the implant surroundings in which infectious conditions produce Ti ions that contribute to more infection, creating a potential cycle of accelerating corrosion.
Collapse
Affiliation(s)
- Kai Yuan Cheng
- Regenerative Medicine and Disability Research Lab, University of Illinois College of Medicine, Rockford, IL, USA
| | - Puranjay Gupta
- Regenerative Medicine and Disability Research Lab, University of Illinois College of Medicine, Rockford, IL, USA
| | - Hemalatha Kanniyappan
- Regenerative Medicine and Disability Research Lab, University of Illinois College of Medicine, Rockford, IL, USA
| | - Hamza Zahurullah
- Regenerative Medicine and Disability Research Lab, University of Illinois College of Medicine, Rockford, IL, USA
| | - Yani Sun
- Department of Biomedical Engineering, College of Engineering, University of Illinois , Chicago, IL, USA
| | - Mostafa Alhamad
- Department of Restorative Dentistry, College of Dentistry, University of Illinois at Chicago, Chicago, IL, USA
- Department of Restorative Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Ad Dammām, Saudi Arabia
| | - Mathew T Mathew
- Regenerative Medicine and Disability Research Lab, University of Illinois College of Medicine, Rockford, IL, USA.
- Department of Restorative Dentistry, College of Dentistry, University of Illinois at Chicago, Chicago, IL, USA.
- Department of Biomedical Engineering, College of Engineering, University of Illinois , Chicago, IL, USA.
| |
Collapse
|
3
|
Tong S, Fang S, Ying K, Chen W. Titanium particles inhibit bone marrow mesenchymal stem cell osteogenic differentiation through the MAPK signaling pathway. FEBS Open Bio 2023; 13:1699-1708. [PMID: 37483149 PMCID: PMC10476562 DOI: 10.1002/2211-5463.13678] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Revised: 06/23/2023] [Accepted: 07/20/2023] [Indexed: 07/25/2023] Open
Abstract
Metallic implants have great application in clinical orthopedics. Implants wear out in vivo due to long-term mechanical loading. The formation of wear debris is one of the long-term complications of prosthesis. In the case of artificial joint replacement in particular, aseptic loosening is the most common reason for secondary revision surgery. Previous studies suggested that wear debris caused aseptic loosening mainly by promoting osteolysis around the prosthesis. In this study, titanium particles, the most commonly used particles in clinical practice, were selected to simulate wear debris and explore the influence of titanium particles on osteogenic differentiation of mesenchymal stem cells. Our results show that titanium particles can significantly inhibit osteogenic differentiation in a dose-dependent manner. While engaged in preliminary exploration of the underlying mechanisms, we found that titanium particles significantly affect phosphorylation of ERK1/2, a key component of MAPK signaling. This suggests that the MAPK signaling pathway is involved in the inhibition of osteogenic differentiation by titanium particles.
Collapse
Affiliation(s)
- Shunyi Tong
- Department of Orthopaedic SurgeryLanxi People's HospitalChina
| | - Sanhua Fang
- Department of Orthopaedic SurgeryLanxi People's HospitalChina
| | - Kangjie Ying
- Department of Orthopaedic SurgeryLanxi People's HospitalChina
| | - Weiwei Chen
- Department of Orthopaedic SurgeryLanxi People's HospitalChina
| |
Collapse
|
4
|
Zhang L, Haddouti EM, Welle K, Burger C, Kabir K, Schildberg FA. Local Cellular Responses to Metallic and Ceramic Nanoparticles from Orthopedic Joint Arthroplasty Implants. Int J Nanomedicine 2020; 15:6705-6720. [PMID: 32982228 PMCID: PMC7494401 DOI: 10.2147/ijn.s248848] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2020] [Accepted: 07/08/2020] [Indexed: 12/27/2022] Open
Abstract
Over the last decades, joint arthroplasty has become a successful treatment for joint disease. Nowadays, with a growing demand and increasingly younger and active patients accepting these approaches, orthopedic surgeons are seeking implants with improved mechanical behavior and longer life span. However, aseptic loosening as a result of wear debris from implants is considered to be the main cause of long-term implant failure. Previous studies have neatly illustrated the role of micrometric wear particles in the pathological mechanisms underlying aseptic loosening. Recent osteoimmunologic insights into aseptic loosening highlight the important and heretofore underrepresented contribution of nanometric orthopedic wear particles. The present review updates the characteristics of metallic and ceramic nanoparticles generated after prosthesis implantation and summarizes the current understanding of their hazardous effects on peri-prosthetic cells.
Collapse
Affiliation(s)
- Li Zhang
- Clinic for Orthopedics and Trauma Surgery, University Hospital Bonn, Venusberg-Campus 1, Bonn 53127, Germany
| | - El-Mustapha Haddouti
- Clinic for Orthopedics and Trauma Surgery, University Hospital Bonn, Venusberg-Campus 1, Bonn 53127, Germany
| | - Kristian Welle
- Clinic for Orthopedics and Trauma Surgery, University Hospital Bonn, Venusberg-Campus 1, Bonn 53127, Germany
| | - Christof Burger
- Clinic for Orthopedics and Trauma Surgery, University Hospital Bonn, Venusberg-Campus 1, Bonn 53127, Germany
| | - Koroush Kabir
- Clinic for Orthopedics and Trauma Surgery, University Hospital Bonn, Venusberg-Campus 1, Bonn 53127, Germany
| | - Frank A Schildberg
- Clinic for Orthopedics and Trauma Surgery, University Hospital Bonn, Venusberg-Campus 1, Bonn 53127, Germany
| |
Collapse
|
5
|
Periprosthetic Osteolysis: Mechanisms, Prevention and Treatment. J Clin Med 2019; 8:jcm8122091. [PMID: 31805704 PMCID: PMC6947309 DOI: 10.3390/jcm8122091] [Citation(s) in RCA: 117] [Impact Index Per Article: 23.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2019] [Revised: 11/28/2019] [Accepted: 11/29/2019] [Indexed: 02/06/2023] Open
Abstract
Clinical studies, as well as in vitro and in vivo experiments have demonstrated that byproducts from joint replacements induce an inflammatory reaction that can result in periprosthetic osteolysis (PPOL) and aseptic loosening (AL). Particle-stimulated macrophages and other cells release cytokines, chemokines, and other pro-inflammatory substances that perpetuate chronic inflammation, induce osteoclastic bone resorption and suppress bone formation. Differentiation, maturation, activation, and survival of osteoclasts at the bone-implant interface are under the control of the receptor activator of nuclear factor kappa-Β ligand (RANKL)-dependent pathways, and the transcription factors like nuclear factor κB (NF-κB) and activator protein-1 (AP-1). Mechanical factors such as prosthetic micromotion and oscillations in fluid pressures also contribute to PPOL. The treatment for progressive PPOL is only surgical. In order to mitigate ongoing loss of host bone, a number of non-operative approaches have been proposed. However, except for the use of bisphosphonates in selected cases, none are evidence based. To date, the most successful and effective approach to preventing PPOL is usage of wear-resistant bearing couples in combination with advanced implant designs, reducing the load of metallic and polymer particles. These innovations have significantly decreased the revision rate due to AL and PPOL in the last decade.
Collapse
|
6
|
Alotaibi HF, Perni S, Prokopovich P. Nanoparticle-based model of anti-inflammatory drug releasing LbL coatings for uncemented prosthesis aseptic loosening prevention. Int J Nanomedicine 2019; 14:7309-7322. [PMID: 31571855 PMCID: PMC6750844 DOI: 10.2147/ijn.s217112] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2019] [Accepted: 07/27/2019] [Indexed: 02/06/2023] Open
Abstract
Introduction The only treatment for aseptic loosening is the replacement of the prosthesis through revision surgery. A preventive approach, achieved through anti-inflammatory drugs released from the device, has shown to be a viable strategy; however, the performance of these devices is not yet satisfactory thus further improvements are necessary. Methods We used titanium nanoparticles as a model for implant surfaces and developed a coating containing dexamethasone (DEX) using layer-by-layer deposition. Results The amount of deposited drug depended on the number of layers and the release was sustained for months. The efficiency of the released DEX in reducing inflammation markers (tumor necrosis factor alpha and IL-6) produced by human monocytes and macrophages was similar to the pure drug at the same concentration without negative impacts on the viability and morphology of these cells. Conclusion These coatings were not inferior to medical grade titanium (the standard material used in uncemented devices) regarding their ability to sustain osteoblasts and fibroblasts growth.
Collapse
Affiliation(s)
| | - Stefano Perni
- School of Pharmacy and Pharmaceutical Sciences, Cardiff University, Cardiff, UK
| | - Polina Prokopovich
- School of Pharmacy and Pharmaceutical Sciences, Cardiff University, Cardiff, UK
| |
Collapse
|
7
|
Perni S, Caserta S, Pasquino R, Jones SA, Prokopovich P. Prolonged Antimicrobial Activity of PMMA Bone Cement with Embedded Gentamicin-Releasing Silica Nanocarriers. ACS APPLIED BIO MATERIALS 2019; 2:1850-1861. [DOI: 10.1021/acsabm.8b00752] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Affiliation(s)
- Stefano Perni
- School of Pharmacy and Pharmaceutical Sciences, Cardiff University, Cardiff CF10 3NB, United Kingdom
| | - Sergio Caserta
- Department of Chemical, Materials and Industrial Production Engineering, University of Naples Federico II, Napoli 80125, Italy
| | - Rossana Pasquino
- Department of Chemical, Materials and Industrial Production Engineering, University of Naples Federico II, Napoli 80125, Italy
| | - Steve A. Jones
- University Hospital Llandough, Cardiff & Vale University Health Board, Penlan Road, Penarth, Vale of Glamorgan, Wales CF64 2XX, United Kingdom
| | - Polina Prokopovich
- School of Pharmacy and Pharmaceutical Sciences, Cardiff University, Cardiff CF10 3NB, United Kingdom
| |
Collapse
|