Elenskaya N, Vindokurov I, Sadyrin E, Nikolaev A, Tashkinov M. Experimental Evaluation of the Effect of Degradation on the Mechanical Behavior and Morphometric Characteristics of Functionally Graded Polymer Scaffolds. Polymers (Basel) 2024; 16:3474. [PMID: 39771326 PMCID: PMC11728786 DOI: 10.3390/polym16243474] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2024] [Revised: 12/06/2024] [Accepted: 12/10/2024] [Indexed: 01/16/2025] Open
Abstract
Bone transplantation ranks second worldwide among tissue prosthesis surgeries. Currently, one of the most promising approaches is regenerative medicine, which involves tissue engineering based on polymer scaffolds with biodegradable properties. Once implanted, scaffolds interact directly with the surrounding tissues and in a fairly aggressive environment, which causes biodegradation of the scaffold material. The aim of this work is to experimentally investigate the changes in the effective mechanical properties of polylactide scaffolds manufactured using additive technologies. The mechanism and the rate of the degradation process depend on the chosen material, contact area, microstructural features, and overall architecture of sample. To assess the influence of each of these factors, solid samples with different dimensions and layers orientation as well as prototypes of functionally graded scaffolds were studied. The research methodology includes the assessment of changes in the mechanical properties of the samples, as well as their structural characteristics. Changes in the mechanical properties were measured in compression tests. Microcomputed tomography (micro-CT) studies were conducted to evaluate changes in the microstructure of scaffold prototypes. Changes caused by surface erosion and their impact on degradation were assessed using morphometric analysis. Nonlinear changes in mechanical properties were observed for both solid samples and lattice graded scaffold prototypes depending on the duration of immersion in NaCl solution and exposure to different temperatures. At the temperature of 37 °C, the decrease in the elastic modulus of solid specimens was no more than 16%, while for the lattice scaffolds, it was only 4%. For expedited degradation during a higher temperature of 45 °C, these ratios were 47% and 16%, respectively. The decrease in compressive strength was no more than 32% for solid specimens and 17% for scaffolds. The results of this study may be useful for the development of optimal scaffolds considering the impact of the degradation process on their structural integrity.
Collapse
Affiliation(s)
- Nataliya Elenskaya
- Laboratory of Mechanics of Biocompatible Materials and Devices, Perm National Research Polytechnic University, 614990 Perm, Russia
| | - Ilia Vindokurov
- Laboratory of Mechanics of Biocompatible Materials and Devices, Perm National Research Polytechnic University, 614990 Perm, Russia
| | - Evgeniy Sadyrin
- Laboratory for Mechanics of Biomaterials, Don State Technical University, 344000 Rostov-on-Don, Russia
| | - Andrey Nikolaev
- Laboratory for Mechanics of Biomaterials, Don State Technical University, 344000 Rostov-on-Don, Russia
| | - Mikhail Tashkinov
- Laboratory of Mechanics of Biocompatible Materials and Devices, Perm National Research Polytechnic University, 614990 Perm, Russia
| |
Collapse
|
2
|
Hijazi KM, Dixon SJ, Armstrong JE, Rizkalla AS. Titanium Alloy Implants with Lattice Structures for Mandibular Reconstruction. MATERIALS (BASEL, SWITZERLAND) 2023; 17:140. [PMID: 38203994 PMCID: PMC10779528 DOI: 10.3390/ma17010140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Revised: 11/30/2023] [Accepted: 12/19/2023] [Indexed: 01/12/2024]
Abstract
In recent years, the field of mandibular reconstruction has made great strides in terms of hardware innovations and their clinical applications. There has been considerable interest in using computer-aided design, finite element modelling, and additive manufacturing techniques to build patient-specific surgical implants. Moreover, lattice implants can mimic mandibular bone's mechanical and structural properties. This article reviews current approaches for mandibular reconstruction, their applications, and their drawbacks. Then, we discuss the potential of mandibular devices with lattice structures, their development and applications, and the challenges for their use in clinical settings.
Collapse
Affiliation(s)
- Khaled M. Hijazi
- School of Biomedical Engineering, Faculty of Engineering, The University of Western Ontario, London, ON N6A 3K7, Canada
- Bone and Joint Institute, The University of Western Ontario, London, ON N6G 2V4, Canada
| | - S. Jeffrey Dixon
- Bone and Joint Institute, The University of Western Ontario, London, ON N6G 2V4, Canada
- Schulich School of Medicine & Dentistry, The University of Western Ontario, London, ON N6A 5C1, Canada
| | - Jerrold E. Armstrong
- Division of Oral and Maxillofacial Surgery, Department of Otolaryngology Head and Neck Surgery, Henry Ford Hospital, Detroit, MI 48202, USA
| | - Amin S. Rizkalla
- School of Biomedical Engineering, Faculty of Engineering, The University of Western Ontario, London, ON N6A 3K7, Canada
- Bone and Joint Institute, The University of Western Ontario, London, ON N6G 2V4, Canada
- Schulich School of Medicine & Dentistry, The University of Western Ontario, London, ON N6A 5C1, Canada
- Chemical and Biochemical Engineering, Faculty of Engineering, The University of Western Ontario, London, ON N6A 5B9, Canada
| |
Collapse
|
3
|
Elenskaya N, Tashkinov M, Vindokurov I, Pirogova Y, Silberschmidt VV. Understanding of trabecular-cortical transition zone: Numerical and experimental assessment of multi-morphology scaffolds. J Mech Behav Biomed Mater 2023; 147:106146. [PMID: 37774442 DOI: 10.1016/j.jmbbm.2023.106146] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Revised: 09/20/2023] [Accepted: 09/22/2023] [Indexed: 10/01/2023]
Abstract
Applications of additive manufacturing (AM) in tissue engineering develop rapidly. AM offers layer-by-layer creation of complex objects, developed to restore functionality of, or replace, damaged tissues. Porous 3D-printed functional gradient structures are of particular interest: their special architecture makes it possible to simulate the heterogeneity of the replaced tissue and, by continuously changing the mechanical properties, to avoid the concentration of stresses that can be caused by abrupt geometric changes. Such structures also allow combinations of different types of unit cells and a smooth transition between them, making design of personalised scaffolds with optimal parameters for the replacement of damaged host tissue at the interface between tissues possible. This paper presents the results of development of scaffold structures with gradients of porosity and multi-morphology using unit cells based on triply periodic minimal surfaces (TPMS). The mechanical behaviour of additively manufactured scaffold prototypes made of polylactide acid (PLA) was studied under compressive loading. Strain fields on their surface were captured using the Vic-3d Micro-DIC digital image correlation system and compared with those obtained with detailed numerical simulations, employing elastic-plastic properties of PLA, obtained in experiments. The effect of gradient parameters and unit-cell morphology on the stress distribution in scaffolds was analysed. A smooth gradient transition between cells with different morphologies was found to reduce the probability of structural failure under intense compressive loading. A good agreement between numerical results and experimental data was achieved, which justifies application of the developed approach to design of personalised bone scaffolds.
Collapse
Affiliation(s)
- Nataliya Elenskaya
- Perm National Research Polytechnic University, Komsomolsky Ave., 29, Perm, Russia
| | - Mikhail Tashkinov
- Perm National Research Polytechnic University, Komsomolsky Ave., 29, Perm, Russia.
| | - Ilia Vindokurov
- Perm National Research Polytechnic University, Komsomolsky Ave., 29, Perm, Russia
| | - Yulia Pirogova
- Perm National Research Polytechnic University, Komsomolsky Ave., 29, Perm, Russia
| | | |
Collapse
|
4
|
Kämmerer PW, Al-Nawas B. Bone reconstruction of extensive maxillomandibular defects in adults. Periodontol 2000 2023; 93:340-357. [PMID: 37650475 DOI: 10.1111/prd.12499] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2023] [Revised: 05/21/2023] [Accepted: 05/26/2023] [Indexed: 09/01/2023]
Abstract
Reconstruction of significant maxillomandibular defects is a challenge that has been much discussed over the last few decades. Fundamental principles were developed decades ago (bone bed viability, graft immobilization). Clinical decision-making criteria are highly relevant, including local/systemic factors and incision designs, the choice of material, grafting technique, and donor site morbidity. Stabilizing particulated grafts for defined defects-that is, via meshes or shells-might allow significant horizontal and vertical augmentation; the alternatives are onlay and inlay techniques. More significant defects might require extra orally harvested autologous bone blocks. The anterior iliac crest is often used for nonvascularized augmentation, whereas more extensive defects often require microvascular reconstruction. In those cases, the free fibula flap has become the standard of care. The development of alternatives is still ongoing (i.e., alloplastic reconstruction, zygomatic implants, obturators, distraction osteogenesis). Especially for these complex procedures, three-dimensional planning tools enable facilitated planning and a surgical workflow.
Collapse
Affiliation(s)
- Peer W Kämmerer
- Department of Oral and Maxillofacial Surgery, University Medical Center Mainz, Mainz, Germany
| | - Bilal Al-Nawas
- Department of Oral and Maxillofacial Surgery, University Medical Center Mainz, Mainz, Germany
| |
Collapse
|
5
|
Palmquist A, Jolic M, Hryha E, Shah FA. Complex geometry and integrated macro-porosity: Clinical applications of electron beam melting to fabricate bespoke bone-anchored implants. Acta Biomater 2023; 156:125-145. [PMID: 35675890 DOI: 10.1016/j.actbio.2022.06.002] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Revised: 05/16/2022] [Accepted: 06/01/2022] [Indexed: 01/18/2023]
Abstract
The last decade has witnessed rapid advancements in manufacturing technologies for biomedical implants. Additive manufacturing (or 3D printing) has broken down major barriers in the way of producing complex 3D geometries. Electron beam melting (EBM) is one such 3D printing process applicable to metals and alloys. EBM offers build rates up to two orders of magnitude greater than comparable laser-based technologies and a high vacuum environment to prevent accumulation of trace elements. These features make EBM particularly advantageous for materials susceptible to spontaneous oxidation and nitrogen pick-up when exposed to air (e.g., titanium and titanium-based alloys). For skeletal reconstruction(s), anatomical mimickry and integrated macro-porous architecture to facilitate bone ingrowth are undoubtedly the key features of EBM manufactured implants. Using finite element modelling of physiological loading conditions, the design of a prosthesis may be further personalised. This review looks at the many unique clinical applications of EBM in skeletal repair and the ground-breaking innovations in prosthetic rehabilitation. From a simple acetabular cup to the fifth toe, from the hand-wrist complex to the shoulder, and from vertebral replacement to cranio-maxillofacial reconstruction, EBM has experienced it all. While sternocostal reconstructions might be rare, the repair of long bones using EBM manufactured implants is becoming exceedingly frequent. Despite the various merits, several challenges remain yet untackled. Nevertheless, with the capability to produce osseointegrating implants of any conceivable shape/size, and permissive of bone ingrowth and functional loading, EBM can pave the way for numerous fascinating and novel applications in skeletal repair, regeneration, and rehabilitation. STATEMENT OF SIGNIFICANCE: Electron beam melting (EBM) offers unparalleled possibilities in producing contaminant-free, complex and intricate geometries from alloys of biomedical interest, including Ti6Al4V and CoCr. We review the diverse range of clinical applications of EBM in skeletal repair, both as mass produced off-the-shelf implants and personalised, patient-specific prostheses. From replacing large volumes of disease-affected bone to complex, multi-material reconstructions, almost every part of the human skeleton has been replaced with an EBM manufactured analog to achieve macroscopic anatomical-mimickry. However, various questions regarding long-term performance of patient-specific implants remain unaddressed. Directions for further development include designing personalised implants and prostheses based on simulated loading conditions and accounting for trabecular bone microstructure with respect to physiological factors such as patient's age and disease status.
Collapse
Affiliation(s)
- Anders Palmquist
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
| | - Martina Jolic
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Eduard Hryha
- Department of Materials and Manufacturing Technologies, Chalmers University of Technology, Gothenburg, Sweden
| | - Furqan A Shah
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
| |
Collapse
|
6
|
Salinero L, Boczar D, Barrow B, Berman ZP, Diep GK, Trilles J, Howard R, Chaya BF, Rodriguez Colon R, Rodriguez ED. Patient-centred outcomes and dental implant placement in computer-aided free flap mandibular reconstruction: a systematic review and meta-analysis. Br J Oral Maxillofac Surg 2022; 60:1283-1291. [PMID: 36280538 DOI: 10.1016/j.bjoms.2022.09.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Accepted: 09/22/2022] [Indexed: 12/31/2022]
Abstract
Computerised surgical planning (CSP) and computer-aided design and manufacturing (CAD/CAM) have been demonstrated to increase surgical accuracy and reduce operative time in free flap mandibular reconstruction, but evidence is lacking as to their impact on patient-centred outcomes. Implant-supported dental prostheses, however, have been associated with improved quality of life outcomes following free flap mandibular reconstruction. We aim to review reported patient-centred outcomes in mandibular reconstruction with CSP and CAD/CAM and determine whether use of these technologies is associated with higher rates of dental implant placement following free flap mandibular reconstruction. On December 20, 2020, a systematic review and meta-analysis were conducted according to PRISMA guidelines for studies reporting quality of life, functional outcomes, and rates of dental implant placement in computer-aided free flap mandibular reconstruction. A random-effects meta-analysis was performed to compare dental implant placement rates between surgeries using CSP and those using conventional freehand techniques. A total of 767 articles were screened. Nine articles reporting patient-centred outcomes and 16 articles reporting dental implant outcomes were reviewed. Of those reporting dental implant outcomes, five articles, representing a total of 302 cases, were included in the meta-analysis. Use of CSP was associated with a significant increase in the likelihood of dental implant placement, with an odds ratio of 2.70 (95% CI 1.52 to 4.79, p = 0.0007). Standardised reporting methods and controlled studies are needed to further investigate the impact of CSP and CAD/CAM technologies on functional outcomes and patient-reported quality of life in free flap mandibular reconstruction. Use of CSP and CAD/CAM technologies is associated with higher rates of dental implant placement in patients undergoing free flap mandibular reconstruction when compared to conventional freehand techniques.
Collapse
Affiliation(s)
- Lauren Salinero
- Hansjörg Wyss Department of Plastic Surgery, New York University Langone Health, 222 E 41st Street, New York, NY, USA
| | - Daniel Boczar
- Hansjörg Wyss Department of Plastic Surgery, New York University Langone Health, 222 E 41st Street, New York, NY, USA
| | - Brooke Barrow
- Hansjörg Wyss Department of Plastic Surgery, New York University Langone Health, 222 E 41st Street, New York, NY, USA
| | - Zoe P Berman
- Hansjörg Wyss Department of Plastic Surgery, New York University Langone Health, 222 E 41st Street, New York, NY, USA
| | - Gustave K Diep
- Hansjörg Wyss Department of Plastic Surgery, New York University Langone Health, 222 E 41st Street, New York, NY, USA
| | - Jorge Trilles
- Hansjörg Wyss Department of Plastic Surgery, New York University Langone Health, 222 E 41st Street, New York, NY, USA
| | - Rachel Howard
- Hansjörg Wyss Department of Plastic Surgery, New York University Langone Health, 222 E 41st Street, New York, NY, USA
| | - Bachar F Chaya
- Hansjörg Wyss Department of Plastic Surgery, New York University Langone Health, 222 E 41st Street, New York, NY, USA
| | - Ricardo Rodriguez Colon
- Hansjörg Wyss Department of Plastic Surgery, New York University Langone Health, 222 E 41st Street, New York, NY, USA
| | - Eduardo D Rodriguez
- Hansjörg Wyss Department of Plastic Surgery, New York University Langone Health, 222 E 41st Street, New York, NY, USA.
| |
Collapse
|
7
|
van Kootwijk A, Moosabeiki V, Saldivar MC, Pahlavani H, Leeflang MA, Kazemivand Niar S, Pellikaan P, Jonker BP, Ahmadi SM, Wolvius EB, Tümer N, Mirzaali MJ, Zhou J, Zadpoor AA. Semi-automated digital workflow to design and evaluate patient-specific mandibular reconstruction implants. J Mech Behav Biomed Mater 2022; 132:105291. [PMID: 35660552 DOI: 10.1016/j.jmbbm.2022.105291] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2022] [Revised: 05/18/2022] [Accepted: 05/19/2022] [Indexed: 12/31/2022]
Abstract
The reconstruction of large mandibular defects with optimal aesthetic and functional outcomes remains a major challenge for maxillofacial surgeons. The aim of this study was to design patient-specific mandibular reconstruction implants through a semi-automated digital workflow and to assess the effects of topology optimization on the biomechanical performance of the designed implants. By using the proposed workflow, a fully porous implant (LA-implant) and a topology-optimized implant (TO-implant) both made of Ti-6Al-4V ELI were designed and additively manufactured using selective laser melting. The mechanical performance of the implants was predicted by performing finite element analysis (FEA) and was experimentally assessed by conducting quasi-static and cyclic biomechanical tests. Digital image correlation (DIC) was used to validate the FE model by comparing the principal strains predicted by the FEM model with the measured distribution of the same type of strain. The numerical predictions were in good agreement with the DIC measurements and the predicted locations of specimen failure matched the actual ones. No statistically significant differences (p < 0.05) in the mean stiffness, mean ultimate load, or mean ultimate displacement were detected between the LA- and TO-implant groups. No implant failures were observed during quasi-static or cyclic testing under masticatory loads that were substantially higher (>1000 N) than the average maximum biting force of healthy individuals. Given its relatively lower weight (16.5%), higher porosity (17.4%), and much shorter design time (633.3%), the LA-implant is preferred for clinical application. This study clearly demonstrates the capability of the proposed workflow to develop patient-specific implants with high precision and superior mechanical performance, which will greatly facilitate cost- and time-effective pre-surgical planning and is expected to improve the surgical outcome.
Collapse
Affiliation(s)
- A van Kootwijk
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology (TU Delft), Mekelweg 2, 2628 CD, Delft, the Netherlands
| | - V Moosabeiki
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology (TU Delft), Mekelweg 2, 2628 CD, Delft, the Netherlands.
| | - M Cruz Saldivar
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology (TU Delft), Mekelweg 2, 2628 CD, Delft, the Netherlands
| | - H Pahlavani
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology (TU Delft), Mekelweg 2, 2628 CD, Delft, the Netherlands
| | - M A Leeflang
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology (TU Delft), Mekelweg 2, 2628 CD, Delft, the Netherlands
| | - S Kazemivand Niar
- Department of Mechanical Engineering, Tarbiat Modares University, Tehran, Iran
| | - P Pellikaan
- Amber Implants BV, Prinses Margrietplantsoen 33, 2595 AM, The Hague, the Netherlands
| | - B P Jonker
- Department of Oral and Maxillofacial Surgery, Erasmus University Medical Center, Doctor Molewaterplein 40, 3015 GE, Rotterdam, the Netherlands
| | - S M Ahmadi
- Amber Implants BV, Prinses Margrietplantsoen 33, 2595 AM, The Hague, the Netherlands
| | - E B Wolvius
- Department of Oral and Maxillofacial Surgery, Erasmus University Medical Center, Doctor Molewaterplein 40, 3015 GE, Rotterdam, the Netherlands
| | - N Tümer
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology (TU Delft), Mekelweg 2, 2628 CD, Delft, the Netherlands
| | - M J Mirzaali
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology (TU Delft), Mekelweg 2, 2628 CD, Delft, the Netherlands
| | - J Zhou
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology (TU Delft), Mekelweg 2, 2628 CD, Delft, the Netherlands
| | - A A Zadpoor
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology (TU Delft), Mekelweg 2, 2628 CD, Delft, the Netherlands
| |
Collapse
|
8
|
Soft Tissue Dehiscence Associated with a Titanium Patient-Specific Implant: A Prosthetic Solution as an Alternative to Soft Tissue Grafting. Case Rep Dent 2022; 2021:5125375. [PMID: 34970459 PMCID: PMC8714330 DOI: 10.1155/2021/5125375] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2021] [Accepted: 10/29/2021] [Indexed: 11/18/2022] Open
Abstract
Patients. This clinical report describes the detailed prosthodontic management of a 23-year-old male patient suffering from soft tissue complication following the placement of a 3d-printed titanium patient-specific implant. This implant was implemented simultaneously with the resection of a calcifying cystic odontogenic tumor related to the maxillary arch. Later, soft tissue dehiscence and implant exposure were encountered with subsequent food impaction, infection, and pus discharge. The treatment plan was to fabricate removable partial denture. The prosthesis was planned to be retained by bar and clip attachment on the patient-specific implant side, while on the other side, the removable prosthesis was allowed to engage two abutments with an embrasure clasp assembly in addition to covering the palatal tissues to offer protection for the soft tissue dehiscence against food impaction. Discussion. Soft tissue dehiscence and implant exposure are among the frequently reported complications associated with the patient-specific implant. The resulting infection complicates the prognosis of the implemented implant and necessitates, in some occasions, its removal. The selection of the removable prosthesis to cover soft tissue dehiscence was a conservative alternative to the implant removal as it protects the exposed titanium surface from food impaction while maintaining the implant functionality. Conclusion. Three-year follow-up showed complete resolution of the patient's complaints while fulfilling the patient's aesthetic and functional demands and indicates that the use of detachable overlay prosthesis could be one of the proposed treatment options.
Collapse
|