1
|
Scleral Fixation of Toric Intraocular Lens in the Absence of Capsular Support. Case Rep Ophthalmol Med 2024; 2024:7157592. [PMID: 38601329 PMCID: PMC11006456 DOI: 10.1155/2024/7157592] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 02/16/2024] [Accepted: 03/04/2024] [Indexed: 04/12/2024] Open
Abstract
The study is aimed at describing a technique for scleral fixation of toric intraocular lens (TIOL) in the eyes without capsular support coexisting with corneal astigmatism. A monofocal toric hydrophobic lens with eyelets at the optic-haptic junction (enVista One-Piece Hydrophobic Acrylic MX60T Toric IOL; Bausch & Lomb) was fixated to the sclera using two fragments of 6-0 polypropylene monofilament, the ends of which were brought out through the sclera and cauterized. The astigmatic axis of a TIOL was adjusted according to the corneal astigmatic axis of the patient. The surgery was performed in the 5 eyes of 5 patients without capsular support. The method was safe and effective in fixing the lens to the sclera, and it ensured good centration of TIOL with predictable refractive outcomes. No conjunctival sutures, glue, or flap formation was required during the surgery. There were no relevant complications related to the procedure.
Collapse
|
2
|
Clinical Outcomes of Transscleral-Sutured Intraocular Lens Combined With Descemet Membrane Endothelial Keratoplasty. Cornea 2023; 42:1497-1502. [PMID: 36729033 DOI: 10.1097/ico.0000000000003215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Accepted: 11/05/2022] [Indexed: 02/03/2023]
Abstract
PURPOSE The aim of the study was to report clinical outcomes of Descemet membrane endothelial keratoplasty (DMEK) combined with transscleral-sutured intraocular lens (IOL) compared with DMEK combined with phacoemulsification and posterior chamber IOL (Phaco-DMEK). METHODS A retrospective chart review of all patients who underwent DMEK combined with transscleral-sutured intraocular lens fixation or combined with phacoemulsification for Fuchs endothelial corneal dystrophy from 2016 to 2021 at the Toronto Western Hospital or the Kensington Eye Institute (Toronto, ON, Canada) and had at least 18 months of follow-up was performed. Main outcomes were postoperative distance-corrected visual acuity, rebubbling rate, graft survival rate, and complications. RESULTS Twenty-one cases of DMEK combined with transscleral-sutured IOL (DMEK-TSS-IOL) and 44 cases of Phaco-DMEK were evaluated. Twelve eyes (57.15%) had a foldable acrylic 3-piece IOL (AR40E) and 9 (42.85%) had a single-piece polymethylmethacrylate (PMMA) IOL (CZ70BD). LogMAR distance-corrected visual acuity improved significantly from 1.48 ± 0.62 (SD) to 0.86 ± 0.82 ( P = 0.01) 12 months after DMEK-TSS-IOL and from 0.41 ± 0.29 logMAR to 0.11 ± 0.11 logMAR ( P < 0.0001) after Phaco-DMEK. No statistically significant differences were observed in donor ( P = 0.97) or 1-year postoperative endothelial cell density ( P = 0.11) between the groups. Rebubbling was necessary in 33.33% of eyes in DMEK-TSS-IOL compared with 25% of Phaco-DMEK eyes ( P = 0.55). Graft survival rate was 76.19% in the DMEK-TSS-IOL group compared with 90.90% in the Phaco-DMEK group ( P = 0.13). CONCLUSIONS Transscleral-sutured IOL combined with DMEK is an option for the management of endothelial diseases in aphakic eyes or those which require IOL exchange for the experienced surgeon. However, when compared with routine Phaco-DMEK, there are higher complication and lower survival rates at 18 months.
Collapse
|
3
|
A long-term clinical outcome of Hoffmann pocket four-point scleral fixated intraocular lens implantation combined with penetrating keratoplasty - A single corneal surgeon's report. Indian J Ophthalmol 2023; 71:2722-2726. [PMID: 37417111 PMCID: PMC10491041 DOI: 10.4103/ijo.ijo_58_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2023] [Revised: 05/14/2023] [Accepted: 05/25/2023] [Indexed: 07/08/2023] Open
Abstract
Purpose To analyze retrospectively the outcomes of Hoffmann pocket scleral fixated intraocular lens implantation combined with penetrating keratoplasty at a tertiary institute by a single corneal surgeon. Methods Forty-two eyes of 42 patients, aged between 11 and 84 years, had a mean follow-up of 2 ± 2.216 years. Overall, five (11.9%) had congenital and 37 had acquired pathology, 15 were pseudophakic, 23 were aphakic, and four were phakic. The commonest indication was trauma in 19 (45.2%), and 21 had previous multiple surgeries including five retinal procedures. Results The grafts were clear in 20 (47.6%), they failed in 20, three had acute rejection, three were ectatic, two had infection, one had persistent edema, and one had endophthalmitis. The mean log of minimum angle of resolution (logMAR) best corrected visual acuity was 1.902 pre-op, 1.802 at the final follow-up, and 0.52 after excluding preexisting retinal pathologies. At the last follow-up, the vision improved in 18 (42.9%), maintained in 6, and worsened in 18, and three needed more than -5.00 D and seven needed more than -3.00 D cylinder correction. Five had glaucoma preoperatively, 10 developed the condition postoperatively, six needed cyclodestructive procedure, and three had valve surgery. Conclusion Advantages of this surgery are avoidance of additional sections to insert the lens, direct positioning of the lens in the posterior chamber, rotational stability of the lens from four-point fixation, and untouched conjunctiva over the scleral pockets. The fact that 20 had clear grafts and 18 visually improved, though two needed lens removal and one developed retinal detachment postsurgery is encouraging. More cases with longer follow-ups will help understand the technique better.
Collapse
|
4
|
Abstract
Despite the safety and efficacy of cataract surgery, intraoperative complications can hamper the ability to place an intraocular lens in the capsular bag. With vast numbers of cataract surgeries performed daily, complications occur often enough that every ophthalmologist should be equipped with techniques to manage aphakia. Medical management of aphakia used to be commonplace but these techniques have their disadvantages including thick bulky lenses, poor cosmesis, and aniseikonia. Surgical management of aphakia overcomes these disadvantages and offers patients the possibility of a spectacle and contact lens-free lifestyle. This article reviews the various options of surgical management of aphakia and their advantages and disadvantages. Comparison of outcomes between techniques and a protocol for deciding between techniques is presented.
Collapse
|
5
|
One-Year Outcomes of Modified Technique for Scleral Fixation of a Three-Piece Intraocular Lens Without Conjunctival Opening. Front Med (Lausanne) 2022; 9:856800. [PMID: 35721099 PMCID: PMC9200955 DOI: 10.3389/fmed.2022.856800] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Accepted: 05/03/2022] [Indexed: 11/13/2022] Open
Abstract
Purpose This study aimed to present the 1-year follow-up of a modified technique for scleral fixation of three-piece intraocular lens (IOLs) without conjunctival incision. Materials and Methods A retrospective chart review of a consecutive series of 10 eyes of nine patients who underwent scleral IOL fixation using the modified technique was performed. Data were collected 1 year after surgery for all patients. Results The range of follow-up time was between 1 year and 31 months. At the last follow-up point, the IOL was well-positioned and the visual acuity was good (as limited by primary diseases). Short-term complications included pupillary IOL capture (n = 1) and decreased intraocular pressure (n = 1), and no long-term complications were observed. Conclusion Outcome data support this technique as a viable option for the management of secondary IOL fixation with flexible usage of more designs of IOLs.
Collapse
|
6
|
Adaptation of extraocular needle-guided haptic insertion technique (X-NIT) for scleral fixation of three piece foldable intraocular lens. BMJ Case Rep 2022; 15:e247869. [PMID: 35459650 PMCID: PMC9036186 DOI: 10.1136/bcr-2021-247869] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/07/2022] [Indexed: 11/04/2022] Open
|
7
|
Reversed scleral tunnel technique for repair of iridodialysis after blunt force trauma: a retrospective clinical study. BMC Ophthalmol 2022; 22:171. [PMID: 35428283 PMCID: PMC9011996 DOI: 10.1186/s12886-022-02394-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Accepted: 04/11/2022] [Indexed: 11/10/2022] Open
Abstract
Abstract
Background
To investigate the efficacy and safety of reversed scleral tunnel technique for repairing iridodialysis after blunt force trauma.
Methods
A total of 51 eyes of 51 patients with iridodialysis undergoing surgery were included in this study. Patients were divided into 2 groups: group A (the reversed scleral tunnel technique) and group B (the control group). Before the procedure and at 1, 3, and 6 months afterward, data on the patients’ age, gender, treatments, diagnosis, mechanism of injury, best-corrected visual acuity (BCVA), intraocular pressure (IOP), degree of iridodialysis, lens status, concomitant ocular damage, number of sutures, complications, and follow-up time were collected and compared between the 2 groups.
Results
Iridodialysis was repaired and the pupil shape was restored to nearly round in all eyes. Standard phacoemulsification or lens removal was performed in all eyes. A final BCVA ≥20/60 was achieved in 13 eyes (48.1%) in Group A and 13 eyes (54.2%) in Group B. The IOP remained stable during the follow-up period in all eyes except 2 eyes (7.4%) in Group A and 3 eyes (12.5%) in Group B with angle recession. There were no statistically significant differences in BCVA and IOP between group A and group B. Intraoperatively, A significantly lower percentage of extensive subconjunctival hemorrhage occurred in Group A compared to Group B (1 eye versus 24 eyes, χ2 = 47.1, P = 0.00). Hyphema was observed in 2 eyes (7.4%) in Group A and 1 eye (4.2%) in Group B. Postoperatively, two eyes (7.4%) in Group A and 2 eyes (8.3%) in Group B developed retinal detachment. No other complications were noted during the follow-up period.
Conclusions
The reversed scleral tunnel technique is a safe and effective approach for repairing iridodialysis after blunt force trauma with few complications, favorable cosmetic and visual outcomes.
Collapse
|
8
|
Sutured Custom Foldable Silicone Artificial Iris Implantation Combined With Intraocular Lens Implantation and Penetrating Keratoplasty: Safety and Efficacy Outcomes. Cornea 2021; 40:1236-1247. [PMID: 33086281 PMCID: PMC8423143 DOI: 10.1097/ico.0000000000002564] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2020] [Revised: 08/27/2020] [Accepted: 08/28/2020] [Indexed: 11/26/2022]
Abstract
PURPOSE To assess safety and efficacy outcomes of sutured custom silicone artificial iris and intraocular lens implantation combined with penetrating keratoplasty (triple procedure). METHODS Prospective consecutive surgical case series of patients who underwent the triple procedure between 2010 and 2019 at Stein Eye Institute, UCLA, followed up for 1 year minimum. Safety outcomes were changes from preoperative to last follow-up in corrected distance visual acuity (CDVA), endothelial cell count, intraocular pressure (IOP), and postoperative complications. Efficacy outcomes included changes in subjective glare (none to severe), cosmetic appearance (worse to very much improved), and visual function as assessed by the Visual Function Questionnaire-25 at 1-year follow-up. RESULTS Among 82 eyes implanted with an artificial iris, 14 eyes (17.1%) underwent the triple procedure. The median follow-up was 18.1 months (range 12.0-54.9 months). The median CDVA improved from 2.0 log of minimum angle of resolution (logMAR) (range 0.9-2.3 logMAR) to 0.7 logMAR (range 0.2-2.6 logMAR) (P = 0.02). Average endothelial cell count decreased 57.6% (P < 0.01). Six eyes (42.9%) experienced IOP elevations, 13 eyes (92.3%) developed iritis, and 11 eyes (78.6%) underwent secondary surgery. Graft rejection or secondary graft failure occurred in 7 eyes each (50.0%). Cosmesis improved in 12 eyes (85.7%; P < 0.01). The Visual Function Questionnaire-25 score improved from 72 to 77 (P < 0.01). Glare symptoms did not change significantly. CONCLUSIONS The triple procedure was effective at improving CDVA, cosmesis, and quality of life; however, it was associated with frequent postoperative complications, of which iritis, IOP elevation, and secondary graft failure were the most common.
Collapse
|
9
|
Modification of intraocular lens insertion using 4-flanged fixation with a standard cartridge and a 2.4 mm corneal incision in eyes with no capsular support. J Cataract Refract Surg 2021; 47:1227-1233. [PMID: 34468460 DOI: 10.1097/j.jcrs.0000000000000600] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Accepted: 01/21/2021] [Indexed: 11/26/2022]
Abstract
A modification of intraocular lens (IOL) implantation, using the 4-flanged IOL fixation technique, through a 2.4 mm corneal incision using a standard cartridge and injector, is presented. An IOL with 4 eyelets is used, through which a 6-0 polypropylene suture is threaded on one side and then loaded into a provided cartridge and inserted to the anterior chamber through a 2.4 mm corneal incision. Using the handshake technique, the suture ends are eventually threaded through the eyelets and secured outside the eye with the creation of 4 flanges. This technique was used in 6 eyes of 5 consecutive patients with the absence of capsular support. During all follow-up visits, the IOLs were well centered and stable, and the flanges were buried in the sclera and covered with the conjunctiva. No complications were recorded. This modification simplifies the technique and reduces the well-known complications of large corneal incisions.
Collapse
|
10
|
Short-term outcomes of a modified technique for small-incision scleral-fixated intraocular lens implantation using Gore-Tex sutures. Graefes Arch Clin Exp Ophthalmol 2021; 259:1889-1896. [PMID: 33914157 DOI: 10.1007/s00417-021-05201-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Revised: 03/29/2021] [Accepted: 04/11/2021] [Indexed: 11/25/2022] Open
Abstract
PURPOSE To report the short-term outcomes of a modified small-incision technique for implantation of scleral-fixated intraocular lenses (IOLs) using Gore-Tex sutures. METHODS A retrospective, interventional, consecutive case series was conducted. From June 2019 to February 2020, 10 patients underwent small-incision scleral-fixated IOL implantation using Gore-Tex sutures at a tertiary referral center. Visual and anatomical outcomes and complications were recorded with a minimum follow-up period of 3 months. Surgically induced astigmatism (SIA) and IOL-induced astigmatism were measured. RESULTS The mean follow-up duration (range) was 396 (240-573) days. Best-corrected visual acuity improved significantly from logarithm of the minimal angle of resolution (logMAR) 0.88 ± 0.65 (Snellen equivalent: 20/153) preoperation to logMAR = 0.30 ± 0.51 (Snellen equivalent: 20/40) at final follow-up (P = .008). The estimated SIA and IOL-induced astigmatism were 0.61 diopters (D) ± 0.49D and 0.40D ± 0.36D, respectively. No intraoperative complications occurred. The postoperative complications, which included ocular hypertension (20%), cystoid macular edema (30%), and vitreous hemorrhage (20%), were transient and resolved with topical medication. CONCLUSIONS The modified small-incision technique for implantation of scleral-fixated IOLs using Gore-Tex sutures was well tolerated in all patients, with favorable postoperative visual outcomes and minimal SIA and IOL-induced astigmatism.
Collapse
|
11
|
Scleral fixation of a single-piece foldable acrylic IOL through a 1.80 mm corneal incision. J Cataract Refract Surg 2021; 46:662-666. [PMID: 32358257 DOI: 10.1097/j.jcrs.0000000000000138] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
A new scleral fixation technique of a single-piece acrylic foldable intraocular lens (IOL) (enVista MX60, Bausch & Lomb, Inc.) through a 1.80 mm corneal incision, using the IOL eyelets as anchoring point, is described. It was a retrospective review of 26 cases. The preoperative mean corrected distance visual acuity was 0.51 ± 0.21 logarithm of the minimum angle of resolution (logMAR). It improved significantly to 0.25 ± 0.27 logMAR (P < .01), 0.18 ± 0.16 logMAR (P < .01), and 0.17 ± 0.16 logMAR (P < .01) (at 1 month, 3 months, and 6 months postoperatively, respectively, repeated measures analysis of variance, P < .0001). No astigmatism increase of more than 0.75 diopters was recorded at any time point. In all 26 patients, the IOL was well centered and stable for the entire monitoring period. No complications were observed during follow-up. Scleral fixation of the foldable IOL through a 1.80 mm corneal incision provided excellent IOL stability during the 6-month follow-up of this study and might be an effective and safe surgical technique.
Collapse
|
12
|
Transfixion of Foldable Intraocular Lens With Polytetrafluoroethylene Suture for Scleral Fixation. J Refract Surg 2021; 37:180-185. [PMID: 34038296 DOI: 10.3928/1081597x-20201222-01] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To describe a new scleral fixation technique potentially usable for every acrylic foldable intraocular lens (IOL) available in the market, regardless of whether it is a three-piece, single-piece, or haptic shape. METHODS Before surgery, the authors performed the transfixion of the IOL optic in four points with the polytetrafluoroethylene suture under a surgical microscope. Four sclerotomy sites were marked 2 mm from the limbus, and two scleral grooves were created in between. The IOL was introduced into the posterior chamber. The four ends of the needleless polytetrafluoroethylene sutures were externalized through the sclerotomies, tightened for optimum IOL centration, and tied. The exposed sutures were placed within the scleral grooves, and the knots were buried within the sclerotomies. This technique was performed uneventfully in 7 cases. RESULTS The foldable IOL was stable in all eyes 6 months after surgery, with no signs of IOL subluxation, dislocation, tilt, or suture-related complications, such as erosion or infection. CONCLUSIONS The transfixion of the foldable posterior chamber IOL for stable four-point scleral fixation using a polytetrafluoroethylene suture provides excellent stability and prevents IOL tilt and decentration. This technique can immensely benefit patients requiring secondary foldable posterior chamber IOL implantation in the absence of capsular support. [J Refract Surg. 2021;37(3):180-185.).
Collapse
|
13
|
Application of a four-flanged intrascleral fixation technique for toric and multifocal intraocular lenses. Am J Ophthalmol Case Rep 2020; 20:100933. [PMID: 33015409 PMCID: PMC7522749 DOI: 10.1016/j.ajoc.2020.100933] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2020] [Revised: 08/25/2020] [Accepted: 09/13/2020] [Indexed: 10/25/2022] Open
Abstract
Purpose To report clinical outcomes of a four-flanged intrascleral fixation technique using toric and multifocal intraocular lens. Observations We describe two cases of premium intraocular lens (IOL) implantation after which the patients fully recovered their visual function following a four-point sutureless scleral fixation technique via a 2.8-mm corneal incision. In the first case, a monofocal toric hydrophobic lens consisting of two haptic plates with four holes for suturing was fixated with 5-0 polypropylene monofilament. In the second case, a bifocal hydrophobic lens with the same haptic design was fixated. No conjunctival or scleral sutures, glue, or flap formation was required during the surgery. There were no complications related to the surgical process. Conclusions and Importance A four-flanged intrascleral fixation technique may benefit patients with poor zonular support who have high expectations for postoperative visual quality.
Collapse
|
14
|
Results in comparison between 30 gauge ultrathin wall and 27 gauge needle in sutureless intraocular lens flanged technique in diabetic patients: 24-month follow-up study. Acta Diabetol 2020; 57:1151-1157. [PMID: 32300875 DOI: 10.1007/s00592-020-01530-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2020] [Accepted: 03/27/2020] [Indexed: 11/24/2022]
Abstract
AIMS Intraoperative complications in cataract surgery are more common in diabetic patients. Solving aphakia in these circumstances remains a challenge, as the scleral structure has been shown to be different in diabetes. This study aims to analyze the role of a secondary sutureless scleral intraocular lens (IOL) flanged fixation in diabetic patients without capsular support and to compare the anatomical and functional outcomes using a 30 gauge (G) ultrathin wall needle vs. a 27G needle. METHODS Retrospective, observational cohort study. 105 eyes (105 patients) who underwent PPV with secondary IOL fixation using a sutureless 27G (n = 51) or a 30G ultrathin wall (UTW) needle technique (n = 54) and had a 24 months postoperative follow up. Consecutive patients' records were reviewed for lens stability and centration parameters, intra- and postoperative complications at 7 days, 1, 3, 6, 12, and 24 months after surgery. Correlations between outcome measures and needle size (27G vs. 30G UTW) were analyzed. RESULTS IOL displacement occurred in 30 patients (41.2%) in the 27G group and did not occur in the 30G UTW needle group (p < 0.001). Mean time until IOL displacement was 10.5 ± 7.0 months (range: 7 days-24 months). IOL centricity was significantly better in the 30G ultrathin wall needle group compared to 27 G (p = 0.001). Additional surgical interventions were necessary only in the 27G group (n = 14). CONCLUSIONS Sutureless IOL flanged technique using a 30G UTW needle is more predictable and has less complications in aphakic diabetic patients, compared to a 27G needle technique.
Collapse
|
15
|
Novel use of an adjustable single 8-0 polypropylene suture of scleral fixation without conjunctival dissection. BMC Ophthalmol 2020; 20:304. [PMID: 32711502 PMCID: PMC7382057 DOI: 10.1186/s12886-020-01558-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2019] [Accepted: 07/07/2020] [Indexed: 12/05/2022] Open
Abstract
Background This report serves to describe the use of a novel adjustable single 8–0 polypropylene suture for scleral fixation without conjunctival dissection, and to describe related clinical outcomes associated with this approach. Methods In this study, we retrospectively reviewed 28 eyes from 27 patients that underwent scleral fixation of the intraocular lens (IOL) without conjunctival dissection using an adjustable single 8–0 polypropylene suture at the Beijing Tongren Eye Center between April 2018 and April 2019. For this surgical approach, a 23-gauge infusion cannula was set, after which two Hoffmann scleral pockets were created. Next, 8–0 polypropylene sutures were inserted into the eye guided by 10–0 polypropylene sutures of a long straight needle. The 8–0 suture was then used to fix the haptic IOs. Finally, these 8–0 polypropylene sutures were removed from the scleral pockets, and knots were tightened with the adjustable single suture. Primary outcomes included visual acuity and postoperative complication incidence. Results For this study, outcomes for 28 eyes from 27 patients (9 female, 18 male) were assessed. Patients had a mean age of 54 ± 15.11 years-old and were followed for an average of 10.18 ± 2.76 months postoperatively. Uncorrected visual acuity in these patients improved significantly from a preoperative value of 1.269 ± 0.464 logMAR to a 3-month postoperative value of 0.409 ± 0.413 logMAR (p = 0.000). The majority of postoperative complications in these patients were temporary and self-limiting, including corneal edema (35.71%), hypotony (14.29%), elevated intraocular pressure (28.58%), and mild hyphema (7.14%). No evidence of exposure or erosion of the trimmed suture end was detected in any patients. An ultrasound biomicroscope was able to readily detect the IOL and all sutures, and IOLs were found to be well-centered without any dislocation, tilting, or subluxation upon follow-up. Conclusions An adjustable single 8–0 polypropylene suture can reliably and effectively be used for scleral fixation without conjunctival dissection for the treatment of patients with aphakia or inadequate posterior capsule support. The novel procedure described herein may therefore be an effective means of minimizing the risk of suture-related complications in patients undergoing scleral-fixated IOL implantation. Trial registration Retrospective case series study, not applicable. NCT04476264.
Collapse
|
16
|
[Complications in sutured scleral fixation of artificial lens implantation]. Ophthalmologe 2019; 116:1200-1206. [PMID: 30997528 DOI: 10.1007/s00347-019-0896-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
BACKGROUND Sutured scleral fixation of an artificial posterior chamber lens is a frequently used method for the treatment of eyes with poor or absent capsular support; however, the complication profile is often considered unfavorable. OBJECTIVE To analyze the postoperative complication profile. METHODS In this monocentric and retrospective analysis of a consecutive case series of patients with standardized sutured scleral fixation of a posterior chamber lens between 2007 and 2017, the documented complications were categorized as a permanent threat to visual acuity, such as endophthalmitis, choroidal hemorrhage, retinal detachment and clinically relevant but without a permanent threat to visual acuity, such as hemorrhage and hypotension. Additionally, the time point when complications first occurred was categorized into the 3 periods 0-3, 4-30 and ≥31 days. RESULTS This is the largest patient collective of a study with scleral fixation of a posterior chamber lens published so far. A total of 338 eyes from 338 patients were included in the study (women 47%) and the median postoperative follow-up period was 60 days (range 1-5833 days). In 68% of the patients at least 1 complication was documented. Complications with a permanent threat to visual acuity occurred in 3% (n = 10) of the patients. The most frequent clinically relevant complications were intraocular hypotension ≤10 mm Hg (35%; n = 119), pupil decentration (28%; n = 93), hyphema, iris or vitreous hemorrhage (10%; n = 34), secondary glaucoma (9%; n = 32) and iris capture (5%; n = 17). Of the complications 41% occurred within the first 3 days and 70% within the first 30 days. Revision surgery was carried out in 4.5% (n = 15) of the patients. CONCLUSION Although complications occurred in two thirds of the interventions, the number of permanent complications with a permanent threat to visual acuity was low. Scleral fixation of an artificial posterior chamber lens is still a justifiable intervention.
Collapse
|
17
|
COMBINED PARS PLANA VITRECTOMY AND SCLERAL FIXATION OF AN INTRAOCULAR LENS USING GORE-TEX SUTURE: One-Year Outcomes. Retina 2018; 38:1377-1384. [PMID: 28492433 DOI: 10.1097/iae.0000000000001692] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To report the 1-year clinical outcomes of combined pars plana vitrectomy and ab externo scleral fixation of an intraocular lens using Gore-Tex suture. METHODS Retrospective, interventional case series. Outcome measures were change in visual acuity and occurrence of intraoperative and postoperative complications with minimum follow-up of 1 year. RESULTS Eighty-four eyes of 83 patients were identified. The mean best available visual acuity improved from 20/782 preoperatively to 20/65 postoperatively (P < 0.001). The mean follow-up was 598 ± 183 days (median 533 days, range 365-1,323 days). There were no intraoperative complications noted. A Bausch & Lomb Akreos AO60 intraocular lens was implanted in 77 eyes and an Alcon CZ70BD in 7 eyes. Postoperative complications included transient vitreous hemorrhage in six eyes (7.1%), cystoid macular edema in four eyes (4.8%), ocular hypertension in three eyes (3.6%), hyphema in two eyes (2.4%), and transient corneal edema in two eyes (2.4%). There were no cases of postoperative endophthalmitis, suture erosion/breakage, hypotony, retinal detachment, suprachoroidal hemorrhage, choroidal detachment, uveitis-glaucoma-hyphema syndrome, or persistent postoperative inflammation during the follow-up period. CONCLUSION Combined pars plana vitrectomy and ab externo scleral fixation of an intraocular lens with Gore-Tex suture was well tolerated at a minimum of 1-year follow-up. No suture-related complications were encountered.
Collapse
|
18
|
Combined 23-gauge transconjunctival vitrectomy and scleral fixation of intraocular lens without conjunctival dissection in managing lens complications. BMC Ophthalmol 2018; 18:108. [PMID: 29688848 PMCID: PMC5914032 DOI: 10.1186/s12886-018-0776-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2017] [Accepted: 04/17/2018] [Indexed: 11/20/2022] Open
Abstract
Background To evaluate the safety and efficacy of combined 23-gauge transconjunctival pars plana vitrectomy and scleral fixation of intraocular lens (IOL) without conjunctival dissection. Methods A retrospective study in Chang Gung Memorial Hospital, Keelung and Taoyuan, Taiwan. Patients receiving combined 23-gauge transconjunctival pars plana vitrectomy and scleral fixation of IOL without conjunctival dissection were enrolled. The ocular findings, causes of lens complication, surgical procedures, type of IOL used, and complications were documented. Results We included 40 eyes from 39 patients (27 male, 12 female) with a mean age of 59.5 [standard deviation (±) 14.8] years old. The mean follow-up duration was 6.8 ± 5.4 months. The cause of lens complications was ocular trauma in 24 (60%) eyes, cataract surgery complications in 11 (28%) eyes, and spontaneous subluxation of crystalline lens in 5 (13%) eyes. The overall best corrected visual acuity (BCVA) (logMAR) improved from 1.359 ± 0.735 to 0.514 ± 0.582 (p < 0.001). The BCVA also improved significantly in each group with different causes of lens complications. Preoperative BCVA was the only factor associated with the postoperative visual outcome (p = 0.008). Most surgery-related complications were self-limited, including mild vitreous hemorrhage (5%), microhyphema (5%), transient elevated intraocular pressure (3%), and transient hypotony (3%). Cystoid macular edema and IOL decentration was found in 3 (8%) eyes and 1 (3%) eye respectively. Conclusions Combined 23-gauge transconjunctival vitrectomy and scleral fixation of IOL without conjunctival dissection is effective and safe in managing a wide variety of lens complications, with good postoperative comfort and visual recovery. Trial registration Retrospective study, not applicable. Electronic supplementary material The online version of this article (10.1186/s12886-018-0776-4) contains supplementary material, which is available to authorized users.
Collapse
|
19
|
Reinforced scleral fixation of foldable intraocular lens by double sutures: comparison with intrascleral intraocular lens fixation. Jpn J Ophthalmol 2018; 62:365-372. [PMID: 29464488 DOI: 10.1007/s10384-018-0579-4] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2017] [Accepted: 01/21/2018] [Indexed: 12/01/2022]
Abstract
PURPOSE The purpose of this study is to describe a new technique for small-incision scleral fixation of intraocular lens (IOL) using double 10-0 polypropylene sutures, and to report the outcomes of IOL position compared with intrascleral IOL fixation at 12-month follow-up. STUDY DESIGN A retrospective comparative study. METHOD This new technique, called double sutured scleral fixated-IOL (DSF-IOL), was created to help with long-term knots strengthening by applying double sutures to each IOL haptic using an augmented Clove-hitch knot instead of the conventional knots tied by single suture. The tilt and decenter of IOL were measured by Scheimpflug camera and other refractive outcomes were compared between two groups at 12-month follow-up. RESULTS This study consisted of 26 eyes (54.2%) from the DSF-IOL group, and 22 eyes (45.8%) from the intrascleral fixated IOL (ISF-IOL) group. No significant differences of mean absolute degree of IOL tilt (2.90 ± 0.77 vs 2.82 ± 0.72; p = 0.633) and IOL decenter (151.90 ± 59.80 vs 175.0 ± 73.14 microns; p = 0.265) were found between the two groups. Post-operative LogMAR visual acuity was not statistically different between the two groups (0.32 ± 0.17 vs 0.41 ± 0.19, p = 0.089). Early post-operative hypotony was only present in the ISF-IOL group (13.6%). CONCLUSION This study shows that DSF-IOL is as effective as ISF-IOL. This technique can be a simpler approach to optimize small-incision scleral fixation of IOL without the complications associated with intrascleral IOL fixation.
Collapse
|
20
|
Management of cataracts and ectopia lentis in children: Practice patterns of pediatric ophthalmologists in India. Indian J Ophthalmol 2017; 65:818-825. [PMID: 28905824 PMCID: PMC5621263 DOI: 10.4103/ijo.ijo_896_16] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
Purpose: To analyze the current practice patterns of Indian pediatric ophthalmologists in the management of lens anomalies. This study was conducted in a tertiary eye care hospital and involved an online questionnaire survey for practicing pediatric ophthalmologists in India. Methods: A questionnaire was devised by the authors, which included the various options available for the management of lens anomalies in children. The questionnaire was sent to each of them using an online portal. Commercial software (Stata ver. 13.1; StataCorp, College Station, TX, USA) was used for statistical analysis. Results: In unilateral cataracts in children aged <6 months, 85.42% of surgeons did not prefer to insert an intraocular lens (IOL). In the age group of 6–12 months, almost half of them preferred to insert an IOL. In the age group of 12–24 months and >24 months, 92.63% and 88.54%, respectively, preferred to insert an IOL. In bilateral cataracts, in children aged <6 months, 91.84% of surgeons did not prefer to insert an IOL, whereas in the age group of 6–12 months, 69.39% did not prefer to insert an IOL. In the age group of 12–24 months and >24 months, 80.61% and 90.82%, respectively, preferred to insert an IOL. Seventy-four percent of surgeons preferred to use a single-piece hydrophobic acrylic IOL. Conclusion: The management of lens anomalies by pediatric ophthalmologists in India varies with laterality and appears to be comparable to that followed worldwide.
Collapse
|
21
|
Secondary Intraocular Lenses by the Retinal Surgeon: from Sclerotomies to Sutures. CURRENT OPHTHALMOLOGY REPORTS 2017. [DOI: 10.1007/s40135-017-0136-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
22
|
Flanged Intrascleral Intraocular Lens Fixation with Double-Needle Technique. Ophthalmology 2017; 124:1136-1142. [PMID: 28457613 DOI: 10.1016/j.ophtha.2017.03.036] [Citation(s) in RCA: 319] [Impact Index Per Article: 45.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2016] [Revised: 02/20/2017] [Accepted: 03/16/2017] [Indexed: 10/19/2022] Open
Abstract
PURPOSE To report the clinical outcomes of a new technique for transconjunctival intrascleral fixation of an intraocular lens (IOL). DESIGN Prospective, noncomparative, interventional case series. PARTICIPANTS One hundred eyes of 97 consecutive patients with aphakia, dislocated IOL, or subluxated crystalline lens who underwent posterior chamber sutureless implantation of an IOL were studied. METHODS Two angled incisions parallel to the limbus were made by 30-gauge thin-wall needles. Haptics of an IOL were externalized with the needles and cauterized to make a flange of the haptics. The flange of the haptics were pushed back and fixed into the scleral tunnels. MAIN OUTCOME MEASURES Best-corrected visual acuity (VA), corneal endothelial cell density, IOL tilt, and complications were determined. RESULTS The IOLs were fixed with exact centration and axial stability. The mean preoperative best-corrected VA was 0.25 logarithm of the minimum angle of resolution (logMAR) units; after surgery, it improved significantly to 0.11 logMAR, 0.09 logMAR, 0.12 logMAR, and 0.04 logMAR at 6, 12, 24, and 36 months, respectively (P < 0.01, P < 0.01, P = 0.03, and P = 0.10, respectively). The mean corneal endothelial cell density decreased from 2341 cells/mm2 before surgery to 2313 cells/mm2, 2240 cells/mm2, 2189 cells/mm2, and 2244 cells/mm2 at 6, 12, 24, and 36 months, respectively (P < 0.01, P < 0.01, P < 0.01, and P = 0.17, respectively). The mean IOL tilt was 3.4°±2.5°. The postoperative complications included iris capture by the IOL in 8 eyes (8%), vitreous hemorrhage in 5 eyes (5%), and cystoid macular edema in 1 eye (1%). There were no incidents of postoperative retinal detachment, endophthalmitis, or IOL dislocation. CONCLUSIONS We have developed a new technique for intrascleral IOL fixation. The flanged IOL fixation technique is a simple and minimally invasive method for achieving good IOL fixation with firm haptic fixation.
Collapse
|