1
|
Zheng R, Xu Z, Qiu Q, Sun S, Li J, Qiu L. Iron-doped carbon nanotubes with magnetic enhanced Fe(VI) degradation of arsanilic acid and inorganic arsenic: Role of intermediate iron species and electron transfer. ENVIRONMENTAL RESEARCH 2024; 244:117849. [PMID: 38061591 DOI: 10.1016/j.envres.2023.117849] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/16/2023] [Revised: 11/27/2023] [Accepted: 11/30/2023] [Indexed: 12/18/2023]
Abstract
Arsanilic acid (p-AsA), a prevalently used feed additive, is frequently detected in environment posing a great threat to humans. Potassium ferrate (Fe(VI)) was an efficient way to tackle arsenic contamination under acid and neutral conditions. However, Fe(VI) showed a noneffective removal of p-AsA under alkaline conditions due to its oxidation capacity attenuation. Herein, a magnetic iron-doped carbon nanotubes (F-CNT) was successfully prepared and further catalyzed Fe(VI) to remove p-AsA and total As species. The Fe(VI)/F-CNT system showed an excellent capability to oxidize p-AsA and adsorb total As species over an environment-related pH range of 6-9. The high-valent iron intermediates Fe(V)/Fe(IV) and the mediated electron-transfer played a significant part in the degradation of p-AsA according to the probes/scavengers experiments and galvanic oxidation process. Moreover, the situ formed iron hydroxide oxide and F-CNT significantly improved the adsorption capacity for total As species. The electron-donating groups (semiquinone and hydroquinone) and high graphitization of F-CNT were responsible for activating Fe(VI) based on the analysis of X-ray photoelectron spectroscopy (XPS). Density functional theory calculations and the detected degradation products both indicated that the amino group and the C-As bond of p-AsA were main reactive sites. Notably, Fe(VI)/F-CNT system was resistant to the interference from Cl-, SO42-, and HCO3-, and could effectively remove p-AsA and total As species even in the presence of complex water matrix. In summary, this work proposed an efficient method to use Fe(VI) for degrading pollutants under alkaline conditions and explore a new technology for livestock wastewater advanced treatment.
Collapse
Affiliation(s)
- Ruibin Zheng
- School of Civil Engineering and Architecture, University of Jinan, Jinan, 250022, China
| | - Zujun Xu
- School of Civil Engineering and Architecture, University of Jinan, Jinan, 250022, China
| | - Qi Qiu
- School of Water Conservancy and Environment, University of Jinan, Jinan, 250022, China
| | - Shaofang Sun
- School of Civil Engineering and Architecture, University of Jinan, Jinan, 250022, China; School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, China.
| | - Jialong Li
- School of Rehabilitation Medicine, Weifang Medical University, Jinan, 261053, China
| | - Liping Qiu
- School of Municipal and Environmental Engineering, Shandong Jianzhu University, Jinan, 250101, China.
| |
Collapse
|
2
|
Saleem MH, Mfarrej MFB, Khan KA, Alharthy SA. Emerging trends in wastewater treatment: Addressing microorganic pollutants and environmental impacts. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 913:169755. [PMID: 38176566 DOI: 10.1016/j.scitotenv.2023.169755] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2023] [Revised: 12/26/2023] [Accepted: 12/27/2023] [Indexed: 01/06/2024]
Abstract
This review focuses on the challenges and advances associated with the treatment and management of microorganic pollutants, encompassing pesticides, industrial chemicals, and persistent organic pollutants (POPs) in the environment. The translocation of these contaminants across multiple media, particularly through atmospheric transport, emphasizes their pervasive nature and the subsequent ecological risks. The urgency to develop cost-effective remediation strategies for emerging organic contaminants is paramount. As such, wastewater-based epidemiology and the increasing concern over estrogenicity are explored. By incorporating conventional and innovative wastewater treatment techniques, this article highlights the integration of environmental management strategies, analytical methodologies, and the importance of renewable energy in waste treatment. The primary objective is to provide a comprehensive perspective on the current scenario, imminent threats, and future directions in mitigating the effects of these pollutants on the environment. Furthermore, the review underscores the need for international collaboration in developing standardized guidelines and policies for monitoring and controlling these microorganic pollutants. It advocates for increased investment in research and development of advanced materials and technologies that can efficiently remove or neutralize these contaminants, thereby safeguarding environmental health and promoting sustainable practice.
Collapse
Affiliation(s)
- Muhammad Hamzah Saleem
- Office of Academic Research, Office of VP for Research & Graduate Studies, Qatar University, Doha 2713, Qatar.
| | - Manar Fawzi Bani Mfarrej
- Department of Life and Environmental Sciences, College of Natural and Health Sciences, Zayed University, Abu Dhabi 144534, United Arab Emirates.
| | - Khalid Ali Khan
- Applied College, Center of Bee Research and its Products, Unit of Bee Research and Honey Production, and Research Center for Advanced Materials Science (RCAMS), King Khalid University, P.O. Box 9004, Abha 61413, Saudi Arabia.
| | - Saif A Alharthy
- Department of Medical Laboratory Sciences, Faculty of Applied Medical Sciences, King Abdulaziz University, P.O. Box 80216, Jeddah 21589, Saudi Arabia; Toxicology and Forensic Sciences Unit, King Fahd Medical Research Center, King Abdulaziz University, P.O. Box 80216, Jeddah 21589, Saudi Arabia.
| |
Collapse
|
3
|
Cao Y, Li J, Wang Z, Guan C, Jiang J. The synergistic effect of oxidant-peroxide coupling systems for water and wastewater treatments. WATER RESEARCH 2024; 249:120992. [PMID: 38096724 DOI: 10.1016/j.watres.2023.120992] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 11/09/2023] [Accepted: 12/07/2023] [Indexed: 01/03/2024]
Abstract
With the growing complexity and severity of water pollution, it has become increasingly challenging to effectively remove contaminants or inactivate microorganisms just by traditional chemical oxidants such as O3, chlorine, Fe(VI) and Mn(VII). Up till now, numerous studies have indicated that these oxidants in combination with peroxides (i.e., hydrogen peroxide (H2O2), peroxymonosulfate (PMS), peracetic acid (PAA) and periodate (PI)) exhibited excellent synergistic oxidation. This paper provided a comprehensive review on the combination of aforementioned oxidant-peroxide applied in water and wastewater treatments. From one aspect, the paper thoroughly elucidated the synergy mechanism of each oxidant-peroxide combination in turn. Among these combinations, H2O2 or PMS generally performed as the activator of four traditional oxidants above to accelerate reactive species generation and therein various reaction mechanisms, including electron transfer, O atom abstraction and oxo ligand substitution, were involved. In addition, although neither PAA nor PI was able to directly activate Fe(VI) and Mn(VII), they could act as the stabilizer of intermediate reactive iron/manganese species to improve the latter utilization efficiency. From another aspect, this paper summarized the influence of water quality parameters, such as pH, inorganic ions and natural organic matter (NOM), on the oxidation performance of most combined systems. Finally, this paper highlighted knowledge gaps and identified areas that require further research.
Collapse
Affiliation(s)
- Ying Cao
- Key Laboratory for City Cluster Environmental Safety and Green Development of the Ministry of Education, Institute of Environmental and Ecological Engineering, Guangdong University of Technology, Guangzhou 510006, China; Southern Marine Science and Engineering Guangdong Laboratory (Guangzhou), Guangzhou, 511458, China
| | - Juan Li
- Advanced Interdisciplinary Institute of Environment and Ecology, Beijing Normal University, Zhu Hai, 519087, China
| | - Zhen Wang
- Key Laboratory for City Cluster Environmental Safety and Green Development of the Ministry of Education, Institute of Environmental and Ecological Engineering, Guangdong University of Technology, Guangzhou 510006, China; Southern Marine Science and Engineering Guangdong Laboratory (Guangzhou), Guangzhou, 511458, China
| | - Chaoting Guan
- Key Laboratory for City Cluster Environmental Safety and Green Development of the Ministry of Education, Institute of Environmental and Ecological Engineering, Guangdong University of Technology, Guangzhou 510006, China; Southern Marine Science and Engineering Guangdong Laboratory (Guangzhou), Guangzhou, 511458, China
| | - Jin Jiang
- Key Laboratory for City Cluster Environmental Safety and Green Development of the Ministry of Education, Institute of Environmental and Ecological Engineering, Guangdong University of Technology, Guangzhou 510006, China; Southern Marine Science and Engineering Guangdong Laboratory (Guangzhou), Guangzhou, 511458, China.
| |
Collapse
|
4
|
Wang XS, Ma CN, Liu YL, Wang GJ, Tang B, Song H, Gao Z, Ma J, Wang L. High efficiency removal of organic and inorganic iodine with ferrate[Fe(VI)] through oxidation and adsorption. WATER RESEARCH 2023; 246:120671. [PMID: 37804804 DOI: 10.1016/j.watres.2023.120671] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Revised: 09/13/2023] [Accepted: 09/24/2023] [Indexed: 10/09/2023]
Abstract
I- is a halogen species existing in natural waters, and the transformation of organic and inorganic iodine in natural and artificial processes would impact the quality of drinking water. Herein, it was found that Fe(VI) could oxidize organic and inorganic iodine to IO3-and simultaneously remove the resulted IO3- through Fe(III) particles. For the river water, wastewater treatment plant (WWTP) effluent, and shale gas wastewater treated by 5 mg/L of Fe(VI) (as Fe), around 63 %, 55 % and 71 % of total iodine (total-I) had been removed within 10 min, respectively. Fe(VI) was superior to coagulants in removing organic and inorganic iodine from the source water. Adsorption kinetic analysis suggested that the equilibrium adsorption amount of I- and IO3- were 11 and 10.1 μg/mg, respectively, and the maximum adsorption capacity of IO3- by Fe(VI) resulted Fe(III) particles was as high as 514.7 μg/mg. The heterogeneous transformation of Fe(VI) into Fe(III) effectively improved the interaction probability of IO3- with iron species. Density functional theory (DFT) calculation suggested that the IO3- was mainly adsorbed in the cavity (between the γ-FeOOH shell and γ-Fe2O3 core) of Fe(III) particles through electrostatic adsorption, van der Waals force and hydrogen bond. Fe(VI) treatment is effective for inhibiting the formation of iodinated disinfection by-products in chlor(am)inated source water.
Collapse
Affiliation(s)
- Xian-Shi Wang
- State Key Laboratory of Urban Water Resource and Environment, School of Environment, Harbin Institute of Technology, Harbin 150090, China
| | - Cai-Ni Ma
- State Key Laboratory of Urban Water Resource and Environment, School of Environment, Harbin Institute of Technology, Harbin 150090, China
| | - Yu-Lei Liu
- State Key Laboratory of Urban Water Resource and Environment, School of Environment, Harbin Institute of Technology, Harbin 150090, China
| | - Gui-Jing Wang
- State Key Laboratory of Urban Water Resource and Environment, School of Environment, Harbin Institute of Technology, Harbin 150090, China
| | - Bo Tang
- State Key Laboratory of Urban Water Resource and Environment, School of Environment, Harbin Institute of Technology, Harbin 150090, China
| | - Heng Song
- State Key Laboratory of Urban Water Resource and Environment, School of Environment, Harbin Institute of Technology, Harbin 150090, China
| | - Zhi Gao
- State Key Laboratory of Urban Water Resource and Environment, School of Environment, Harbin Institute of Technology, Harbin 150090, China
| | - Jun Ma
- State Key Laboratory of Urban Water Resource and Environment, School of Environment, Harbin Institute of Technology, Harbin 150090, China
| | - Lu Wang
- State Key Laboratory of Urban Water Resource and Environment, School of Environment, Harbin Institute of Technology, Harbin 150090, China.
| |
Collapse
|
5
|
He H, Zhao J. The efficient degradation of diclofenac by ferrate and peroxymonosulfate: performances, mechanisms, and toxicity assessment. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2023; 30:11959-11977. [PMID: 36103067 DOI: 10.1007/s11356-022-22967-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Accepted: 09/05/2022] [Indexed: 06/15/2023]
Abstract
In this study, the degradation efficiency and reaction mechanisms of diclofenac (DCF), a nonsteroidal anti-inflammatory drug, by the combination of ferrate (Fe(VI) and peroxymonosulfate (PMS) (Fe(VI)/PMS) were systematically investigated. The higher degradation efficiency of DCF in Fe(VI)/PMS system can be obtained than that in alone persulfate (PS), Fe(VI), PMS, or the Fe(VI)/PS process at pH 6.0. DCF was efficiently removed in Fe(VI)/PMS process within a wide range of pH values from 4.0 to 8.0, with higher degradation efficiency in acidic conditions. The increasing reaction temperature (10 to 30 ℃), Fe(VI) dose (6.25 to 100 µM), or PMS concentration (50 to 1000 µM) significantly enhanced the DCF degradation. The existences of HCO3¯, Cl¯, and humic acid (HA) obviously inhibited the DCF removal. Electron paramagnetic resonance (EPR), free radical quenching, and probing experiments confirmed the existence of sulfate radicals (SO4•¯), hydroxyl radicals (•OH), and Fe(V)/ Fe(IV), which are responsible for DCF degradation in Fe(VI)/PMS system. The variations of TOC removal ratio reveal that the adsorption of organics with ferric particles, formed in the reduction of Fe(VI), also were functioned in the removal process. Sixteen DCF transformation byproducts were identified by UPLC-QTOF/MS, and the toxicity variation was evaluated. Consequently, eight reaction pathways for DCF degradation were proposed. This study provides theoretical basis for the utilization of Fe(VI)/PMS process.
Collapse
Affiliation(s)
- Haonan He
- College of Chemistry and Materials Science, Sichuan Normal University, Jingan Road 5#, Jinjiang District, Chengdu, 610066, Sichuan, China
| | - Junfeng Zhao
- College of Chemistry and Materials Science, Sichuan Normal University, Jingan Road 5#, Jinjiang District, Chengdu, 610066, Sichuan, China.
- Key Laboratory of Special Waste Water Treatment, Sichuan Province Higher Education System, Sichuan, Chengdu, 610066, China.
- Key Laboratory of Land Resources Evaluation and Monitoring in Southwest, Ministry of Education of China, Chengdu, 610066, China.
| |
Collapse
|