1
|
Morales-Fernández L, Martínez-de-la-Casa JM, Sáenz-Francés F, Perez-García P, Borrego-Sanz L, García-Feijóo J. Detection and characterisation of visual field defects using Octopus perimetry in congenital glaucoma. ARCHIVOS DE LA SOCIEDAD ESPANOLA DE OFTALMOLOGIA 2024; 99:91-97. [PMID: 38043736 DOI: 10.1016/j.oftale.2023.11.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Accepted: 10/12/2023] [Indexed: 12/05/2023]
Abstract
PURPOSE To detect and characterise visual field (VF) defects using static Octopus perimetry in patients with primary congenital glaucoma (PCG) and to determine VF quality and time duration. MATERIAL AND METHODS Eighty-eight eyes of 70 patients diagnosed with PCG were included. Assessments were performed using an Octopus 900 and each eye was assessed with the tendency-oriented perimetry (G-TOP) algorithm. Quantitative VF data were collected: quality data (false positive and negative response, and time duration) and results of mean deviation (MD) and square root of loss variance (sLV). Qualitative data were collected: the presence of diffuse and localized defects, the affected hemifield and grade of defects using the Aulhorn and Karmeyer classification. Correlations between perimetric results and clinical variables were analysed. RESULTS Median age was 11 (8-17) years. 65.9% (58/88) of PCG eyes showed VF defects. Diffuse defects were observed in 10/58 eyes (16.94%) (mean MD = 23.92 [SD: 2.52]) dB) and localized defects in 48/58 eyes (82.75%). The most frequent defect was spot-like/stroke-like/incipient paracentral scotoma (n = 15), nasal step (n = 8), adding arcuate defect (n = 2), half ring-shaped (n = 13) and concentric defect with a central island (n = 9). And the most frequent affected visual hemifield was inferior hemifield. Mean test duration was 2 min 12 s (SD: 21.6 s). MD and sLV values were correlated with best corrected visual acuity (BCVA), cup to disc ratio and number of antiglaucoma surgeries (all P < .001). CONCLUSION A high number of diffuse and localized defects were identified using Octopus perimetry in PCG patients. The most frequent defect was paracentral scotoma and inferior hemifield was the most affected.
Collapse
Affiliation(s)
- L Morales-Fernández
- Servicio de Oftalmología, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), Madrid, Spain; Hospital Universitario Quirón, Pozuelo de Alarcón, Madrid, Spain.
| | - J M Martínez-de-la-Casa
- Servicio de Oftalmología, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), Madrid, Spain; Servicio de Oftalmología, Hospital Clínico San Carlos, Departamento de Oftalmología y ORL, Facultad de Medicina, Universidad Complutense de Madrid, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), Madrid, Spain; Cooperative Research Network on Age-Related Ocular Disease, and Visual and Life Quality, Instituto de Salud Carlos III, Madrid, Spain
| | - F Sáenz-Francés
- Servicio de Oftalmología, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), Madrid, Spain
| | - P Perez-García
- Servicio de Oftalmología, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), Madrid, Spain
| | - L Borrego-Sanz
- Servicio de Oftalmología, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), Madrid, Spain
| | - J García-Feijóo
- Servicio de Oftalmología, Hospital Clínico San Carlos, Departamento de Oftalmología y ORL, Facultad de Medicina, Universidad Complutense de Madrid, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), Madrid, Spain; Cooperative Research Network on Age-Related Ocular Disease, and Visual and Life Quality, Instituto de Salud Carlos III, Madrid, Spain; Instituto de Investigaciones Oftalmológicas Ramón Castroviejo, Universidad Complutense de Madrid, Madrid, Spain
| |
Collapse
|
2
|
Molero-Senosiain M, Morales-Fernandez L, Saenz-Frances F, Kwan J, Garcia Feijoo J, Martínez-de-la-Casa JM. Analysis of the influence of corneal properties and densitometry on applanation and rebound tonometry in primary open angle glaucoma. J Fr Ophtalmol 2023; 46:249-257. [PMID: 36739259 DOI: 10.1016/j.jfo.2022.08.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Revised: 07/30/2022] [Accepted: 08/16/2022] [Indexed: 02/05/2023]
Abstract
PURPOSE To evaluate the influence of corneal densitometry on portable applanation (Perkins) and rebound (iCare ic100 and PRO) tonometry. A secondary goal was to assess if there was a relationship between various corneal properties and the severity of primary open angle glaucoma (POAG). MATERIAL AND METHODS Seventy-five eyes of 75 patients with primary open angle glaucoma were studied, divided by severity into 3 groups: 25 mild, 25 moderate and 25 advanced. Intraocular pressure (IOP) was measured 3 times in each participant with a Perkins applanation tonometer (PAT), a handheld version of the Goldman applanation tonometer (GAT), an iCare PRO and an iCare ic100. Mean values were then calculated. Corneal topography with the Pentacam HR (Oculus, Wetzlar, Germany) was also performed in all individuals. RESULTS Mean age and sex were comparable in all groups, as were densitometry values (P>0.05). The mean visual field defect (MD) was 2.85 (±1.23) dB in the mild glaucoma group, 8.26 (±1.90) dB in the moderate group and 15.66 (±3.46) dB in the advanced group. Three multivariate regression analyses were performed. The first and second calculations assessed the effect of IOP obtained with iCare ic100 and PAT as dependent variables with age, sex, CCT and mean keratometry (Km) within the glaucoma subgroups and the global sample. The third analysis was carried out to assess the relationship between corneal densitometry as the dependant variable and the aforementioned corneal parameters among the glaucoma groups. In the first multivariate regression analysis, a statistically significant correlation was found between ic100 rebound tonometry and CCT in the POAG global sample (coef. 0.117; IC [-0.21-(-0.01)]; P=0.025). No statistically significant correlation was found in the subgroup analyses. In the second multivariate analysis, no significant correlation was found between PAT and CCT, Km, age or sex (P>0.05). In the third analysis, densitometry was correlated with age in all glaucoma subgroups (P<0.001) and with CCT in the moderate glaucoma subgroup (coef. -0.037; IC [-0.67-(-0.01)]; P=0.021). Tonometry appeared to be minimally influenced by corneal densitometry, with a mild positive linear correlation seen (R=0.03). IOP values were similar with 3 of the tonometers: PAT 16.07 (±3.18) mmHg, PRO 16.27 (±3.42) mmHg and ic100 15.17 (±4.28) mmHg. There was, however, a significant underestimation of IOP with ic100 (-0.89mmHg) compared to PAT (P=0.007). CONCLUSION Corneal densitometry did not show significant differences between glaucoma severity groups. A positive correlation was seen with CCT and both corneal densitometry and age. No correlation was found with keratometry or severity of glaucoma. The influence of corneal densitometry on IOP measurements appears weak, with little clinical relevance identified.
Collapse
Affiliation(s)
| | | | | | - J Kwan
- Univeristy Hospitals of Leicester, England, Leicester, United Kingdom
| | | | | |
Collapse
|
3
|
García-Jiménez A, Consejo A. Suspect glaucoma detection from corneal densitometry supported by machine learning. JOURNAL OF OPTOMETRY 2022; 15 Suppl 1:S12-S21. [PMID: 36210294 PMCID: PMC9732483 DOI: 10.1016/j.optom.2022.09.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Revised: 08/25/2022] [Accepted: 09/15/2022] [Indexed: 06/16/2023]
Abstract
PURPOSE To discriminate suspect glaucomatous from control eyes using corneal densitometry based on the statistical modeling of the pixel intensity distribution of Scheimpflug images. METHODS Twenty-four participants (10 suspect glaucomatous and 14 control eyes) were included in this retrospective study. Corneal biomechanics was assessed with the commercial Scheimpflug camera Corvis ST (Oculus). Sets of 140 images acquired per measurement were exported for further analysis. After corneal segmentation, pixel intensities corresponding to different corneal depths were statistically modeled for each image, from which corneal densitometry in the form of parameters α (brightness) and β (homogeneity) was derived. After data pre-processing, parameters α and β were input to six supervised machine learning algorithms that were trained, tested, and compared. RESULTS There exists a statistically significant difference in α and β parameters between suspect glaucomatous and control eyes (both, P < 0.05/N, Bonferroni). From the implemented supervised machine learning algorithms, the K-nearest neighbors (K-NN) algorithm reached 83.93% accuracy to discriminate between groups only using corneal densitometry parameters (α and β). CONCLUSION Densitometry of the anterior cornea including epithelium on its own has the potential to serve as a clinical tool for early glaucoma risk assessment.
Collapse
Affiliation(s)
| | - Alejandra Consejo
- Department of Applied Physics, University of Zaragoza, Zaragoza, Spain.
| |
Collapse
|
4
|
Consejo A, Jiménez-García M, Rozema JJ, Abass A. Influence of eye tilt on corneal densitometry. Ophthalmic Physiol Opt 2022; 42:1032-1037. [PMID: 35708180 PMCID: PMC9543421 DOI: 10.1111/opo.13020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2022] [Revised: 05/24/2022] [Accepted: 05/24/2022] [Indexed: 11/24/2022]
Abstract
PURPOSE To investigate whether Pentacam densitometry readings are affected by corneal tilt. METHODS In a prospective study, the right eyes of 86 healthy participants aged 42.8 ± 20.0 years (range 18-79 years) were imaged using Scheimpflug tomography. Elevation maps were exported to calculate corneal tilt using custom-made software, and densitometry readings were acquired directly from the corneal densitometry analysis add-on to the standard software Oculus Pentacam HR. Simple mediation analysis was applied to study age as a confounding factor in the correlation between corneal tilt and corneal densitometry. RESULTS Corneal tilt and corneal densitometry are not independent from one another because age is significantly correlated with both corneal tilt (r = 0.50, p < 0.001) and corneal densitometry (r = 0.91, p < 0.001). Only 3.8% of the correlation between tilt and densitometry operates directly, while the remaining 96.2% depends on age. CONCLUSIONS Corneal tilt plays a role in corneal densitometry readings, even though the interaction is strongly influenced by age. Age is a well-known factor in densitometry readings that should be taken into consideration when interpreting Scheimpflug densitometry.
Collapse
Affiliation(s)
- Alejandra Consejo
- Department of Applied Physics, University of Zaragoza, Zaragoza, Spain
| | - Marta Jiménez-García
- Department of Ophthalmology, Antwerp University Hospital, Edegem, Belgium.,Visual Optics Lab Antwerp (VOLANTIS), Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium
| | - Jos J Rozema
- Department of Ophthalmology, Antwerp University Hospital, Edegem, Belgium.,Visual Optics Lab Antwerp (VOLANTIS), Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium
| | - Ahmed Abass
- Department of Mechanical, Materials and Aerospace Engineering, School of Engineering, University of Liverpool, Liverpool, UK.,Department of Production Engineering and Mechanical Design, Faculty of Engineering, Port Said University, Port Said, Egypt
| |
Collapse
|
5
|
Corneal densitometry and biomechanical properties in patients with primary congenital glaucoma. Can J Ophthalmol 2021; 56:364-370. [PMID: 33577755 DOI: 10.1016/j.jcjo.2021.01.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2020] [Revised: 11/15/2020] [Accepted: 01/09/2021] [Indexed: 11/23/2022]
Abstract
OBJECTIVE To describe corneal densitometry, topographic measurements, and biomechanical properties in patients with primary congenital glaucoma (PCG) and healthy patients. To examine correlations between variables and determine their glaucoma diagnostic capacity. METHODS This was a cross-sectional, case-control study conducted in 50 eyes of 50 patients with PCG (G1) and 40 eyes of 40 healthy patients (G2). The variables determined in each participant were: intraocular pressure, best corrected visual acuity (BCVA), corneal densitometry, topographic data using the Pentacam HR-Scheimpflug imaging system (Oculus Optikgerate GmbH, Wetzlar, Germany), and corneal hysteresis (CH) and corneal resistance factor (CRF) using the Ocular Response Analyzer (Reichert Ophthalmic Instruments, Depew, NY). RESULTS Overall densitometry was significatively higher in the PCG group (G1: 17.94 ± 4.99 vs G2: 13.25 ± 1.96, p < 0.001). CH (G1: 8.02 ± 11.35 vs G2: 11.35 ± 1.42, p < 0.001) and CRF (G1: 9.48 ± 2.83 vs G2: 10.77 ± 1.34, p < 0.001) were lower in the glaucoma group. Mean posterior, central, and anterior elevation and mean keratometry were higher in G1 (p < 0.05). In the PCG group, overall densitometry showed significant correlation with CH (r = -0.321, p = 0.028) and with BCVA (r = -0.498, p = 0.002). AUCs (areas under the curve) for CH and overall densitometry were high (0.839 and 0.899 respectively) and the best overall densitometry; CH and CRF cutoffs were 14.0, 9.3 and 9.2 respectively. CONCLUSION Densitometry is increased, and biomechanical corneal properties are decreased in patients with PCG. Densitometry and visual acuity showed a negative and significant correlation, so this measurement could be used as an indirect parameter of BCVA in the clinical practice.
Collapse
|
6
|
Corneal Properties in Primary Open-angle Glaucoma Assessed Through Scheimpflug Corneal Topography and Densitometry. J Glaucoma 2020; 30:444-450. [PMID: 33394845 DOI: 10.1097/ijg.0000000000001770] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2020] [Accepted: 12/10/2020] [Indexed: 12/13/2022]
Abstract
PURPOSE The purpose of this study was to compare corneal topography and densitometry measurements in patients with primary open-angle glaucoma (POAG) and healthy subjects. PATIENTS AND METHODS A total of 200 eyes of 75 patients with POAG and 125 healthy controls underwent corneal topography and densitometry (Oculus Pentacam HR). The data compared in the 2 groups were: anterior chamber angle, anterior chamber depth, and anterior chamber volume, keratometry (Kminimum, Kmaximum, and Kmean), central corneal thickness, central anterior elevation, anterior elevation apex, maximum anterior elevation, and posterior elevation apex. Densitometry measurements were made at 3 depths on a 12-mm-diameter circle divided into 4 concentric rings (0 to 2, 2 to 6, 6 to 10, and 10 to 12 mm). The diagnostic capacity of the corneal variables was assessed through the areas under the receiver operating characteristics curve. RESULTS The corneal density of practically all depth layers and total corneal density were significantly higher in the POAG than the control group (P<0.05). Total corneal density was positively correlated with age (r=0.623; P<0.001) and also showed a good diagnostic capacity for glaucoma [area under the curve=0.617; 95% confidence interval (CI): 0.541-0.697; P<0.001]. In a multiple linear regression designed to assess its relationship with age, sex, central corneal thickness, and Kmean, age emerged as a significant confounder both in controls (coefficient=0.315; P<0.001; 95% CI: 0.246-0.384) and patients (coefficient=0.370; P<0.001; 95% CI: 0.255-0.486). CONCLUSION Corneal densitometry measurements showed a good diagnostic capacity for POAG suggesting this type of examination could have clinical applications in the diagnosis and management of glaucoma.
Collapse
|