1
|
Urase M, Maejima Y, Watanabe T, Kishikawa K, Fudouzi H, Kohri M. Crack-Free Structural Color Materials Prepared without Disrupting the Particle Arrangement by Controlling the Internal Stress Relaxation and Interactions of the Melanin Particles. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2023. [PMID: 37300496 DOI: 10.1021/acs.langmuir.3c00720] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
In fabricating structural color materials with assembled colloidal particles, there is a trade-off between the internal stresses acting on the particles and the interactions between the particles during solvent volatilization. It is crucial to fabricate crack-free materials that maintain the periodic arrangements of the particles by understanding the mechanism for crack initiation. Here, we focused on the composition and additives of melanin particle dispersions to obtain crack-free structural color materials without disturbing the particle arrangements. The use of a water/ethanol mixture as a dispersant effectively reduced the internal stresses of the particles during solvent evaporation. Furthermore, the addition of low-molecular-weight, low-volatility ionic liquids ensured that the arrangement and interactions of the particles were maintained after solvent volatilization. Optimization of the composition and additives of the dispersion made it possible to achieve crack-free melanin-based structural color materials while maintaining vivid, angular-dependent color tones.
Collapse
Affiliation(s)
- Mai Urase
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan
| | - Yui Maejima
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan
| | - Taku Watanabe
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan
| | - Keiki Kishikawa
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan
| | - Hiroshi Fudouzi
- National Institute for Materials Science, 1-2-1 Sengen, Tsukuba-Shi, Ibaraki 305-0047, Japan
| | - Michinari Kohri
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan
| |
Collapse
|
2
|
Guan S, Fu Q, Wang D, Han Y, Cao N, Zhang M, Shen H, Yang R, He B, Tao M, Hu F, Jiang X, Zheng L, Situ B. Point-of-Care Urinalysis with One Drop of Sample Using an Aggregation-Induced Emission Luminogen under the Coffee-Ring Effect. ACS Sens 2022; 7:3481-3490. [PMID: 36286999 DOI: 10.1021/acssensors.2c01824] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Development of a practical point-of-care test for urinalysis is crucial for early diagnosis and treatment of chronic kidney disease (CKD). However, the classical gold standard detection method depends on sophisticated instruments and complicated procedures, impeding them from being utilized in resource-limited settings and daily screening. Herein, we report a rapid point-of-care device for the simultaneous quantification of microalbuminuria and leukocyte using one drop of urine. A luminogen (TTVP) with an aggregation-induced emission property can selectively activate its near-infrared fluorescence in the presence of albumin and leukocyte via hydrophobic or electrostatic interactions. The fluorescence signals from urine albumin and leukocyte could be well-separated combined with the coffee-ring effect. Using a smartphone-based detection device, simultaneous quantification of urine albumin and leukocyte was successfully achieved, which only took 20 min and required one drop of urine. The performance of this system is also verified with 120 clinical samples, which might serve as a simple, low-cost, and rapid tool for CKD screening and disease monitoring at the point of care.
Collapse
Affiliation(s)
- Shujuan Guan
- Department of Laboratory Medicine, Nanfang Hospital, Southern Medical University, Guangzhou510515, China
| | - Qiangqiang Fu
- Department of Laboratory Medicine, Nanfang Hospital, Southern Medical University, Guangzhou510515, China
| | - Dong Wang
- Center for AIE Research College of Materials Science and Engineering, Shenzhen University, Shenzhen518060, China
| | - Yunpeng Han
- Department of Laboratory Medicine, Nanfang Hospital, Southern Medical University, Guangzhou510515, China
| | - Nannan Cao
- Department of Laboratory Medicine, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou510120, China
| | - Minying Zhang
- Department of Laboratory Medicine, Nanfang Hospital, Southern Medical University, Guangzhou510515, China
| | - Hanchen Shen
- Hong Kong Branch of Chinese National Engineering Research Center for Tissue Restoration and Reconstruction and Institute of Advanced Study, The Hong Kong University of Science and Technology, Hong Kong999077, China
| | - Ruyue Yang
- Department of Laboratory Medicine, Nanfang Hospital, Southern Medical University, Guangzhou510515, China
| | - Bairong He
- Department of Laboratory Medicine, Nanfang Hospital, Southern Medical University, Guangzhou510515, China
| | - Maliang Tao
- Department of Laboratory Medicine, Nanfang Hospital, Southern Medical University, Guangzhou510515, China
| | - Fang Hu
- Biomaterials Research Center, School of Biomedical Engineering, Southern Medical University, Guangzhou510515, China
| | - Xiujuan Jiang
- Department of Laboratory Medicine, Nanfang Hospital, Southern Medical University, Guangzhou510515, China
| | - Lei Zheng
- Department of Laboratory Medicine, Nanfang Hospital, Southern Medical University, Guangzhou510515, China
| | - Bo Situ
- Department of Laboratory Medicine, Nanfang Hospital, Southern Medical University, Guangzhou510515, China
| |
Collapse
|