Bayerl C, Safraou Y, Reiter R, Proß V, Lehmann K, Kühl AA, Shahryari M, Hamm B, Sack I, Makowski MR, Braun J, Asbach P. Investigation of hepatic inflammation via viscoelasticity at low and high mechanical frequencies - A magnetic resonance elastography study. J Mech Behav Biomed Mater 2024; 160:106711. [PMID: 39244991 DOI: 10.1016/j.jmbbm.2024.106711] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Revised: 08/20/2024] [Accepted: 09/01/2024] [Indexed: 09/10/2024]
Abstract
PURPOSE To study the potential of viscoelastic parameters such as liver stiffness, loss tangent (marker of viscous properties) and viscoelastic dispersion to detect hepatic inflammation by in-vivo and ex-vivo MR elastography (MRE) at low and high vibration frequencies. METHODS 15 patients scheduled for liver tumor resection surgery were prospectively enrolled in this IRB-approved study and underwent multifrequency in-vivo MRE (30-60Hz) at 1.5-T prior to surgery. Immediately after liver resection, tumor-free tissue specimens were examined with ex-vivo MRE (0.8-2.8 kHz) at 0.5-T and histopathologic analysis including NAFLD activity score (NAS) and inflammation score (I-score) as sum of histological sub-features of inflammation. RESULTS In-vivo, in regions where tissue samples were obtained, the loss tangent correlated with the I-score (R = 0.728; p = 0.002) and c-dispersion (stiffness dispersion over frequency) correlated with lobular inflammation (R = -0.559; p = 0.030). In a subgroup of patients without prior chemotherapy, c-dispersion correlated with I-score also in the whole liver (R = -0.682; p = 0.043). ROC analysis of the loss tangent for predicting the I-score showed a high AUC for I ≥ 1 (0.944; p = 0.021), I ≥ 2 (0.804; p = 0.049) and I ≥ 3 (0.944; p = 0.021). Ex-vivo MRE was not sensitive to inflammation, whereas strong correlations were observed between fibrosis and stiffness (R = 0.589; p = 0.021), penetration rate (R = 0.589; p = 0.021), loss tangent (R = -0.629; p = 0.012), and viscoelastic model parameters (spring-pot powerlaw exponent, R = -0.528; p = 0.043; spring-pot shear modulus, R = 0.589; p = 0.021). CONCLUSION Our results suggest that c-dispersion of the liver is sensitive to inflammation when measured in-vivo in the low dynamic range (30-60Hz), while at higher frequencies (0.8-2.8 kHz) viscoelastic parameters are dominated by fibrosis.
Collapse
Affiliation(s)
- Christian Bayerl
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Department of Radiology, Hindenburgdamm 30, 12203 Berlin, Germany.
| | - Yasmine Safraou
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Department of Radiology, Hindenburgdamm 30, 12203 Berlin, Germany
| | - Rolf Reiter
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Department of Radiology, Hindenburgdamm 30, 12203 Berlin, Germany; Berlin Institute of Health at Charité - Universitätsmedizin Berlin, BIH Biomedical Innovation Academy, BIH Charité Digital Clinician Scientist Program, Charitéplatz 1, 10117 Berlin, Germany
| | - Vanessa Proß
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Department of Surgery, Hindenburgdamm 30, 12203 Berlin, Germany
| | - Kai Lehmann
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Department of Surgery, Hindenburgdamm 30, 12203 Berlin, Germany
| | - Anja A Kühl
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, iPATH.Berlin Core Unit, Hindenburgdamm 30, 12203 Berlin, Germany
| | - Mehrgan Shahryari
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Department of Radiology, Hindenburgdamm 30, 12203 Berlin, Germany
| | - Bernd Hamm
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Department of Radiology, Hindenburgdamm 30, 12203 Berlin, Germany
| | - Ingolf Sack
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Department of Radiology, Hindenburgdamm 30, 12203 Berlin, Germany
| | - Marcus R Makowski
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Department of Radiology, Hindenburgdamm 30, 12203 Berlin, Germany; Technical University of Munich (TUM), Germany; School of Medicine & Klinikum Rechts der Isar, Department of Diagnostic and Interventional Radiology, Germany
| | - Jürgen Braun
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Department of Radiology, Hindenburgdamm 30, 12203 Berlin, Germany
| | - Patrick Asbach
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Department of Radiology, Hindenburgdamm 30, 12203 Berlin, Germany
| |
Collapse
|
2
|
Rojekar S, Parit S, Gholap AD, Manchare A, Nangare SN, Hatvate N, Sugandhi VV, Paudel KR, Ingle RG. Revolutionizing Eye Care: Exploring the Potential of Microneedle Drug Delivery. Pharmaceutics 2024; 16:1398. [PMID: 39598522 PMCID: PMC11597228 DOI: 10.3390/pharmaceutics16111398] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2024] [Revised: 08/09/2024] [Accepted: 09/16/2024] [Indexed: 11/29/2024] Open
Abstract
Microneedle technology revolutionizes ocular drug delivery by addressing challenges in treating ocular diseases. This review explores its potential impact, recent advancements, and clinical uses. This minimally invasive technique offers precise control of drug delivery to the eye, with various microneedle types showing the potential to penetrate barriers in the cornea and sclera, ensuring effective drug delivery. Recent advancements have improved safety and efficacy, offering sustained and controlled drug delivery for conditions like age-related macular degeneration and glaucoma. While promising, challenges such as regulatory barriers and long-term biocompatibility persist. Overcoming these through interdisciplinary research is crucial. Ultimately, microneedle drug delivery presents a revolutionary method with the potential to significantly enhance ocular disease treatment, marking a new era in eye care.
Collapse
Affiliation(s)
- Satish Rojekar
- Department of Pharmacological Sciences, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA
| | - Swapnali Parit
- Institute of Chemical Technology, Marathwada Campus, Jalna 431203, India; (S.P.); (A.M.); (N.H.)
| | - Amol D. Gholap
- Department of Pharmaceutics, St. John Institute of Pharmacy and Research, Palghar 401404, India;
| | - Ajit Manchare
- Institute of Chemical Technology, Marathwada Campus, Jalna 431203, India; (S.P.); (A.M.); (N.H.)
| | - Sopan N. Nangare
- Department of Pharmaceutics, H. R. Patel Institute of Pharmaceutical Education and Research, Shirpur 425405, India;
| | - Navnath Hatvate
- Institute of Chemical Technology, Marathwada Campus, Jalna 431203, India; (S.P.); (A.M.); (N.H.)
| | - Vrashabh V. Sugandhi
- College of Pharmacy & Health Sciences, St. John’s University, 8000 Utopia Parkway, Queens, NY 11439, USA;
| | - Keshav Raj Paudel
- Centre for Inflammation, School of Life Sciences, Faculty of Science, Centenary Institute and University of Technology Sydney, Sydney, NSW 2007, Australia;
| | - Rahul G. Ingle
- Datta Meghe College of Pharmacy, Datta Meghe Institute of Higher Education and Research (Deemed to Be University)—DMIHER, Wardha 442107, India
| |
Collapse
|
3
|
Kobayashi S, King F, Hata N. Automatic segmentation of prostate and extracapsular structures in MRI to predict needle deflection in percutaneous prostate intervention. Int J Comput Assist Radiol Surg 2023; 18:449-460. [PMID: 36152168 PMCID: PMC9974805 DOI: 10.1007/s11548-022-02757-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2022] [Accepted: 09/13/2022] [Indexed: 11/05/2022]
Abstract
PURPOSE Understanding the three-dimensional anatomy of percutaneous intervention in prostate cancer is essential to avoid complications. Recently, attempts have been made to use machine learning to automate the segmentation of functional structures such as the prostate gland, rectum, and bladder. However, a paucity of material is available to segment extracapsular structures that are known to cause needle deflection during percutaneous interventions. This research aims to explore the feasibility of the automatic segmentation of prostate and extracapsular structures to predict needle deflection. METHODS Using pelvic magnetic resonance imagings (MRIs), 3D U-Net was trained and optimized for the prostate and extracapsular structures (bladder, rectum, pubic bone, pelvic diaphragm muscle, bulbospongiosus muscle, bull of the penis, ischiocavernosus muscle, crus of the penis, transverse perineal muscle, obturator internus muscle, and seminal vesicle). The segmentation accuracy was validated by putting intra-procedural MRIs into the 3D U-Net to segment the prostate and extracapsular structures in the image. Then, the segmented structures were used to predict deflected needle path in in-bore MRI-guided biopsy using a model-based approach. RESULTS The 3D U-Net yielded Dice scores to parenchymal organs (0.61-0.83), such as prostate, bladder, rectum, bulb of the penis, crus of the penis, but lower in muscle structures (0.03-0.31), except and obturator internus muscle (0.71). The 3D U-Net showed higher Dice scores for functional structures ([Formula: see text]0.001) and complication-related structures ([Formula: see text]0.001). The segmentation of extracapsular anatomies helped to predict the deflected needle path in MRI-guided prostate interventions of the prostate with the accuracy of 0.9 to 4.9 mm. CONCLUSION Our segmentation method using 3D U-Net provided an accurate anatomical understanding of the prostate and extracapsular structures. In addition, our method was suitable for segmenting functional and complication-related structures. Finally, 3D images of the prostate and extracapsular structures could simulate the needle pathway to predict needle deflections.
Collapse
Affiliation(s)
- Satoshi Kobayashi
- National Center for Image Guided Therapy, Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, 75 Francis Street, Boston, MA, 02115, USA.
- Urology, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 8128582, Japan.
| | - Franklin King
- National Center for Image Guided Therapy, Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, 75 Francis Street, Boston, MA, 02115, USA
| | - Nobuhiko Hata
- National Center for Image Guided Therapy, Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, 75 Francis Street, Boston, MA, 02115, USA
| |
Collapse
|
4
|
|
5
|
Nadda R, Repaka R, Sahani AK. Finite element simulation of multilayer model to simulate fine needle insertion mechanism into iliac crest for bone marrow biopsy. Comput Methods Biomech Biomed Engin 2022; 26:877-892. [PMID: 35770927 DOI: 10.1080/10255842.2022.2095204] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
The main aim of this work is to use a finite element technique (FEM) to gain understanding about the bone marrow biopsy (BMB) needle insertion process and needle-tissue interactions in the human iliac crest. A multi-layer iliac crest model consists of stratum corneum, dermis, epidermis, hypodermis, cortical, and cancellous bone has been established. This paper proposes a FE model that examines all phases of tissue deformation, including puncture, cutting, needle-tissue interaction, and various stress-strain values for BMB needle during interaction. The results explain the needle-tissue interface and show the potential of this technique to estimate bone damage and tissue deformation for multiple needle dimensions, coefficient of friction, and penetration speeds. The insertion and extraction force of conical-shaped needles in the multi-layered iliac crest model decreased by 18.92% and 37.5%, respectively, as the needle diameter reduced from 11 G to 20 G. It has also been found that the significant insertion motion raises the deformation of the tissue due to the augmented frictional forces but reduces the strain perpendicular to the penetration direction closer to the needle tip. The simulation outcomes are helpful for the optimal design of fine biopsy needles used to perform the bone marrow biopsies.
Collapse
Affiliation(s)
- Rahul Nadda
- Department of Biomedical Engineering, Indian Institute of Technology Ropar, Punjab, India
| | - Ramjee Repaka
- Department of Biomedical Engineering, Indian Institute of Technology Ropar, Punjab, India
| | - Ashish Kumar Sahani
- Department of Biomedical Engineering, Indian Institute of Technology Ropar, Punjab, India
| |
Collapse
|
6
|
Dai X, Zhang Y, Jiang J, Zhang S. A needle deflection model with operating condition optimization for corrective force‐based needle guidance during transrectal prostate brachytherapy. Int J Med Robot 2022; 18:e2388. [DOI: 10.1002/rcs.2388] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Revised: 03/03/2022] [Accepted: 03/04/2022] [Indexed: 11/09/2022]
Affiliation(s)
- Xuesong Dai
- Key Laboratory of Advanced Manufacturing and Intelligent Technology Ministry of Education Harbin University of Science and Technology Harbin China
| | - Yongde Zhang
- Key Laboratory of Advanced Manufacturing and Intelligent Technology Ministry of Education Harbin University of Science and Technology Harbin China
| | - Jingang Jiang
- Key Laboratory of Advanced Manufacturing and Intelligent Technology Ministry of Education Harbin University of Science and Technology Harbin China
| | - Shu Zhang
- Foshan Baikang Robot Technology Co., Ltd. Foshan China
| |
Collapse
|
7
|
M M, Bobji MS, Simha KRY. Cone cracks in tissue-mimicking hydrogels during hypodermic needle insertion: the role of water content. SOFT MATTER 2022; 18:3521-3530. [PMID: 35438127 DOI: 10.1039/d2sm00257d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Needle insertion into soft biological tissues is a common process in various surgical procedures. During insertion, soft biological tissues with different water contents undergo large deformation often leading to uncontrollable cracks and tissue damage. Despite the numerous experimental studies and numerical modelling of needle-tissue interaction, the results do not show any consistency mainly due to the heterogeneity of tissue properties and opaqueness. In this context, understanding the fracture behaviour of soft tissues during needle insertion is important for minimally invasive surgeries and other medical procedures. Recently, we showed that the needle insertion into a transparent, tissue-mimicking polyacrylamide (PAAm) hydrogel causes periodic cone cracks. In this work, we systematically varied the water content of the PAAm hydrogel in the preparation state and performed needle insertion experiments using a hypodermic needle at a constant velocity to study the fracture characteristics of the PAAm hydrogel. The results show that the number of peaks, the magnitudes of the insertion forces, and corresponding cone cracks decrease with increasing water content. Furthermore, we discussed the influence of water on cone crack fracture characteristics, cone angle, periodicity, crack speed and fracture energy release rate. These results provide a better understanding of the fracture processes of soft tissues with different water concentrations such as the lung, liver, and brain during needle insertion and the control of tissue damage during needle insertion involved in medical procedures.
Collapse
Affiliation(s)
- Muthukumar M
- Department of Mechanical Engineering, Indian Institute of Science, Bangalore, 560012, India.
- Marche Healthcare Pvt Ltd, Pondicherry, 605006, India
| | - M S Bobji
- Department of Mechanical Engineering, Indian Institute of Science, Bangalore, 560012, India.
| | - K R Y Simha
- Department of Mechanical Engineering, Indian Institute of Science, Bangalore, 560012, India.
| |
Collapse
|
8
|
Andrade DLLS, Guedert R, Pintarelli GB, Rangel MMM, Oliveira KD, Quadros PG, Suzuki DOH. Electrochemotherapy treatment safety under parallel needle deflection. Sci Rep 2022; 12:2766. [PMID: 35177779 PMCID: PMC8854592 DOI: 10.1038/s41598-022-06747-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Accepted: 02/02/2022] [Indexed: 11/09/2022] Open
Abstract
Electrochemotherapy is a selective electrical-based cancer treatment. A thriving treatment depends on the local electric field generated by pairs of electrodes. Electrode damage as deflection can directly affect this treatment pillar, the distribution of the electric field. Mechanical deformations such as tip misshaping and needle deflection are reported with needle electrode reusing in veterinary electrochemotherapy. We performed in vitro and in silico experiments to evaluate potential problems with ESOPE type II electrode deflection and potential treatment pitfalls. We also investigated the extent to which the electric currents of the electroporation model can describe deflection failure by comparing in vitro with the in silico model of potato tuber (Solanum tuberosum). The in silico model was also performed with the tumor electroporation model, which is more conductive than the vegetal model. We do not recommend using deflected electrodes. We have found that a deflection of ± 2 mm is unsafe for treatment. Inward deflection can cause dangerous electrical current levels when treating a tumor and cannot be described with the in silico vegetal model. Outward deflection can cause blind spots in the electric field.
Collapse
Affiliation(s)
- Daniella L L S Andrade
- Institute of Biomedical Engineering, Federal University of Santa Catarina, Florianópolis, 88040-900, Brazil
| | - Raul Guedert
- Institute of Biomedical Engineering, Federal University of Santa Catarina, Florianópolis, 88040-900, Brazil
| | - Guilherme B Pintarelli
- Institute of Biomedical Engineering, Federal University of Santa Catarina, Florianópolis, 88040-900, Brazil
| | | | | | | | - Daniela O H Suzuki
- Institute of Biomedical Engineering, Federal University of Santa Catarina, Florianópolis, 88040-900, Brazil.
| |
Collapse
|
9
|
Fracture behaviour of human skin in deep needle insertion can be captured using validated cohesive zone finite-element method. Comput Biol Med 2021; 139:104982. [PMID: 34749097 DOI: 10.1016/j.compbiomed.2021.104982] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2021] [Revised: 10/10/2021] [Accepted: 10/23/2021] [Indexed: 11/24/2022]
Abstract
Medical needles have shown an appreciable contribution to the development of novel medical devices and surgical technologies. A better understanding of needle-skin interactions can advance the design of medical needles, modern surgical robots, and haptic devices. This study employed finite element (FE) modelling to explore the effect of different mechanical and geometrical parameters on the needle's force-displacement relationship, the required force for the skin puncture, and generated mechanical stress around the cutting zone. To this end, we established a cohesive FE model, and identified its parameters by a three-stage parameter identification algorithm to closely replicate the experimental data of needle insertion into the human skin available in the literature. We showed that a bilinear cohesive model with initial stiffness of 5000 MPa/mm, failure traction of 2 MPa, and separation length of 1.6 mm can lead to a model that can closely replicate experimental results. The FE results indicated that while the coefficient of friction between the needle and skin substantially changes the needle reaction force, the insertion velocity does not have a noticeable effect on the reaction force. Regarding the geometrical parameters, needle cutting angle is the prominent factor in terms of stress fields generated in the skin tissue. However, the needle diameter is more influential on the needle reaction force. We also presented an energy study on the frictional dissipation, damage dissipation, and strain energy throughout the insertion process.
Collapse
|
10
|
Influence of fibrosis progression on the viscous properties of in vivo liver tissue elucidated by shear wave dispersion in multifrequency MR elastography. J Mech Behav Biomed Mater 2021; 121:104645. [PMID: 34166871 DOI: 10.1016/j.jmbbm.2021.104645] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2020] [Revised: 05/14/2021] [Accepted: 06/09/2021] [Indexed: 12/19/2022]
Abstract
PURPOSE Many elastography studies have shown that liver stiffness increases with fibrosis and thus can be used as a reliable marker for noninvasively staging fibrosis. However, the sensitivity of viscosity-related mechanical parameters, such as shear wave dispersion, to liver fibrosis is less well understood. METHODS In this proof-of-concept study, 15 healthy volunteers and 37 patients with chronic liver disease and biopsy-proven fibrosis were prospectively investigated by MR elastography at six drive frequencies of 35-60 Hz. Maps of shear wave speed (SWS, in m/s) and loss angle (φ, in rad), as a marker of stiffness and viscous properties, respectively, were generated using tomoelastography data processing. The Child-Pugh score was used to assess cirrhosis severity. RESULTS While SWS increased with fibrosis (F0: 1.53 ± 0.11 m/s, F1-F3: 1.71 ± 0.17 m/s, F4: 2.50 ± 0.39 m/s; P < 0.001), φ remained unchanged during mild to severe fibrosis (F0: 0.63 ± 0.05 rad, F1-F3: 0.60 ± 0.05 rad, P = 0.21) but increased in cirrhosis (F4: 0.81 ± 0.16 rad; P < 0.001). Correspondingly, the slope of SWS-dispersion within the investigated range of vibration frequencies increased from insignificant (F0-F3: 0.010 ± 0.007 m/s/Hz) to significant (F4: 0.038 ± 0.025 m/s/Hz; P = 0.005). Significant correlation with the Child-Pugh score was found for φ (R = 0.60, P = 0.01) but not for SWS. CONCLUSION Although cirrhosis is associated with liver stiffening and, intuitively, transition towards more rigid material properties, the observed increases in φ and slope of SWS-dispersion indicate abnormally high mechanical friction in cirrhotic livers. This biophysical signature might provide a prognostic imaging marker for the detection of pathological processes associated with fibrosis independent of stiffness.
Collapse
|
11
|
Li ADR, Liu Y, Plott J, Chen L, Montgomery JS, Shih A. Multi-Bevel Needle Design Enabling Accurate Insertion in Biopsy for Cancer Diagnosis. IEEE Trans Biomed Eng 2021; 68:1477-1486. [PMID: 33507862 PMCID: PMC8104469 DOI: 10.1109/tbme.2021.3054922] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
OBJECTIVE To obtain definitive cancer diagnosis for suspicious lesions, accurate needle deployment and adequate tissue sampling in needle biopsy are essential. However, the single-bevel needles in current biopsy devices often induce deflection during insertion, potentially causing lesion missampling/undersampling and cancer misdiagnosis. This study aims to reveal the biopsy needle design criteria enabling both low deflection and adequate tissue sampling. METHODS A novel model capable of predicting needle deflection and tissue deformation was first established to understand needle-tissue interaction with different needle tip geometries. Experiments of needle deflection and ex-vivo tissue biopsy were conducted for model validation. RESULTS The developed model showed a reasonably good prediction on the correlation of needle tip type vs. the resultant needle deflection and tissue sampling length. A new multi-bevel needle with the tissue separation point below the needle groove face has demonstrated to be an effective design with an 87% reduction in deflection magnitude and equivalently long tissue sampling length compared to the current single-bevel needle. CONCLUSION This study has revealed two critical design criteria for biopsy needles: 1) multiple bevel faces at the needle tip can generate forces to balance bending moments during insertion to enable a low needle deflection and 2) the tissue separation point should be below the needle groove face to ensure long tissue sampling length. SIGNIFICANCE The developed methodologies and findings in this study serve as proof-of-concept and can be utilized to investigate various biopsy procedures to improve cancer diagnostic accuracy as well as other procedures requiring accurate needle insertion.
Collapse
|
12
|
Spinczyk D, Stronczek M, Badura A, Sperka P, Krywalska D, Wolinska A, Krasoń A, Fabian S, Bas M, Woloshuk A, Zylkowski J, Rosiak G, Konecki D, Milczarek K, Rowinski O, Pietka E. Initial clinical evaluation of image fusion based on rigid registration and supporting percutaneous liver tumor ablation. Biocybern Biomed Eng 2020. [DOI: 10.1016/j.bbe.2020.07.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
13
|
Li ADR, Putra KB, Chen L, Montgomery JS, Shih A. Mosquito proboscis-inspired needle insertion to reduce tissue deformation and organ displacement. Sci Rep 2020; 10:12248. [PMID: 32699296 PMCID: PMC7376018 DOI: 10.1038/s41598-020-68596-w] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2019] [Accepted: 06/24/2020] [Indexed: 11/20/2022] Open
Abstract
This study investigates mosquito proboscis-inspired (MPI) insertion applied to the clinically used biopsy needle to reduce tissue deformation and organ displacement. Advanced medical imagining has enabled early-stage identification of cancerous lesions that require needle biopsy for minimally invasive tissue sampling and pathological analysis. Accurate cancer diagnosis depends on the accuracy of needle deployment to the targeted cancerous lesion site. However, currently available needle delivery systems deform and move soft tissue and organs, leading to a non-diagnostic biopsy or undersampling of the target. Two features inspired by the mosquito proboscis were adopted for MPI insertion in prostate biopsy: (1) the harpoon-shape notches at the needle tip and (2) reciprocating needle-cannula motions for incremental insertion. The local tissue deformation and global prostate displacement during the MPI vs. traditional direct insertions were quantified by optically tracking the displacement of particle-embedded tissue-mimicking phantoms. Results show that the MPI needle insertion reduced both local tissue deformation and global prostate displacement because of the opposite needle-cannula motions and notches which stabilized and reduced the tissue deformation during insertion. Findings provide proof of concept for MPI insertion in the clinical biopsy procedures as well as insights of needle–tissue interaction for future biopsy technology development.
Collapse
Affiliation(s)
- Annie D R Li
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI, USA.
| | - Ketut B Putra
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI, USA
| | - Lei Chen
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI, USA.,Department of Psychiatry, University of Michigan, Ann Arbor, MI, USA
| | | | - Albert Shih
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI, USA.,Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
| |
Collapse
|