1
|
Berry DB, Galinsky VL, Hutchinson EB, Galons JP, Ward SR, Frank LR. Double pulsed field gradient diffusion MRI to assess skeletal muscle microstructure. Magn Reson Med 2023; 90:1582-1593. [PMID: 37392410 DOI: 10.1002/mrm.29751] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 04/28/2023] [Accepted: 05/21/2023] [Indexed: 07/03/2023]
Abstract
PURPOSE Preliminary study to determine whether double pulsed field gradient (PFG) diffusion MRI is sensitive to key features of muscle microstructure related to function. METHODS The restricted diffusion profile of molecules in models of muscle microstructure derived from histology were systematically simulated using a numerical simulation approach. Diffusion tensor subspace imaging analysis of the diffusion signal was performed, and spherical anisotropy (SA) was calculated for each model. Linear regression was used to determine the predictive capacity of SA on the fiber area, fiber diameter, and surface area to volume ratio of the models. Additionally, a rat model of muscle hypertrophy was scanned using a single PFG and a double PFG pulse sequence, and the restricted diffusion measurements were compared with histological measurements of microstructure. RESULTS Excellent agreement between SA and muscle fiber area (r2 = 0.71; p < 0.0001), fiber diameter (r2 = 0.83; p < 0.0001), and surface area to volume ratio (r2 = 0.97; p < 0.0001) in simulated models was found. In a scanned rat leg, the distribution of these microstructural features measured from histology was broad and demonstrated that there is a wide variance in the microstructural features observed, similar to the SA distributions. However, the distribution of fractional anisotropy measurements in the same tissue was narrow. CONCLUSIONS This study demonstrates that SA-a scalar value from diffusion tensor subspace imaging analysis-is highly sensitive to muscle microstructural features predictive of function. Furthermore, these techniques and analysis tools can be translated to real experiments in skeletal muscle. The increased dynamic range of SA compared with fractional anisotropy in the same tissue suggests increased sensitivity to detecting changes in tissue microstructure.
Collapse
Affiliation(s)
- D B Berry
- Department of Orthopedic Surgery, University of California, San Diego, California, USA
- Department of Nanoengineering, University of California, San Diego, San Diego, California, USA
| | - V L Galinsky
- Center for Scientific Computation in Imaging, University of California, San Diego, San Diego, California, USA
| | - E B Hutchinson
- Department of Biomedical Engineering, University of Arizona, Tucson, Arizona, USA
| | - J P Galons
- Department of Medical Imaging, University of Arizona, Tucson, Arizona, USA
| | - S R Ward
- Department of Orthopedic Surgery, University of California, San Diego, California, USA
- Department of Radiology, University of California, San Diego, California, USA
- Department of Bioengineering, University of California, San Diego, California, USA
| | - L R Frank
- Center for Scientific Computation in Imaging, University of California, San Diego, San Diego, California, USA
| |
Collapse
|
2
|
Frank LR, Zahneisen B, Galinsky VL. JEDI: Joint Estimation Diffusion Imaging of macroscopic and microscopic tissue properties. Magn Reson Med 2020; 84:966-990. [PMID: 31916626 DOI: 10.1002/mrm.28141] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2019] [Revised: 11/12/2019] [Accepted: 11/30/2019] [Indexed: 11/07/2022]
Abstract
PURPOSE A new method for enhancing the sensitivity of diffusion MRI (dMRI) by combining the data from single (sPFG) and double (dPFG) pulsed field gradient experiments is presented. METHODS This method uses our JESTER framework to combine microscopic anisotropy information from dFPG experiments using a new method called diffusion tensor subspace imaging (DiTSI) to augment the macroscopic anisotropy information from sPFG data analyzed using our guided by entropy spectrum pathways method. This new method, called joint estimation diffusion imaging (JEDI), combines the sensitivity to macroscopic diffusion anisotropy of sPFG with the sensitivity to microscopic diffusion anisotropy of dPFG methods. RESULTS Its ability to produce significantly more detailed anisotropy maps and more complete fiber tracts than existing methods within both brain white matter (WM) and gray matter (GM) is demonstrated on normal human subjects on data collected using a novel fast, robust, and clinically feasible sPFG/dPFG acquisition. CONCLUSIONS The potential utility of this method is suggested by an initial demonstration of its ability to mitigate the problem of gyral bias. The capability of more completely characterizing the tissue structure and connectivity throughout the entire brain has broad implications for the utility and scope of dMRI in a wide range of research and clinical applications.
Collapse
Affiliation(s)
- Lawrence R Frank
- Center for Scientific Computation in Imaging, University of California at San Diego, La Jolla, CA, USA
- Center for Functional MRI, University of California at San Diego, La Jolla, CA, USA
| | | | - Vitaly L Galinsky
- Center for Scientific Computation in Imaging, University of California at San Diego, La Jolla, CA, USA
- Electrical and Computer Engineering Department, University of California at San Diego, La Jolla, CA, USA
| |
Collapse
|
3
|
Double-pulsed diffusional kurtosis imaging for the in vivo assessment of human brain microstructure. Neuroimage 2015; 120:371-81. [DOI: 10.1016/j.neuroimage.2015.07.013] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2015] [Revised: 06/27/2015] [Accepted: 07/05/2015] [Indexed: 12/20/2022] Open
|
4
|
Clayden JD, Nagy Z, Weiskopf N, Alexander DC, Clark CA. Microstructural parameter estimation in vivo using diffusion MRI and structured prior information. Magn Reson Med 2015; 75:1787-96. [PMID: 25994918 PMCID: PMC4791093 DOI: 10.1002/mrm.25723] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2014] [Revised: 03/17/2015] [Accepted: 03/18/2015] [Indexed: 12/05/2022]
Abstract
Purpose Diffusion MRI has recently been used with detailed models to probe tissue microstructure. Much of this work has been performed ex vivo with powerful scanner hardware, to gain sensitivity to parameters such as axon radius. By contrast, performing microstructure imaging on clinical scanners is extremely challenging. Methods We use an optimized dual spin‐echo diffusion protocol, and a Bayesian fitting approach, to obtain reproducible contrast (histogram overlap of up to 92%) in estimated maps of axon radius index in healthy adults at a modest, widely‐available gradient strength (35 mT m
−1). A key innovation is the use of influential priors. Results We demonstrate that our priors can improve precision in axon radius estimates—a 7‐fold reduction in voxelwise coefficient of variation in vivo—without significant bias. Our results may reflect true axon radius differences between white matter regions, but this interpretation should be treated with caution due to the complexity of the tissue relative to our model. Conclusions Some sensitivity to relatively large axons (3–15 μm) may be available at clinical field and gradient strengths. Future applications at higher gradient strength will benefit from the favorable eddy current properties of the dual spin‐echo sequence, and greater precision available with suitable priors. Magn Reson Med, 2015. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. Magn Reson Med 75:1787–1796, 2016. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance.
Collapse
Affiliation(s)
| | - Zoltan Nagy
- Wellcome Trust Centre for Neuroimaging, UCL Institute of Neurology, University College London, London, UK.,Laboratory for Social and Neural Systems Research, University of Zurich, Zurich, Switzerland
| | - Nikolaus Weiskopf
- Wellcome Trust Centre for Neuroimaging, UCL Institute of Neurology, University College London, London, UK
| | - Daniel C Alexander
- Centre for Medical Image Computing, University College London, London, UK
| | - Chris A Clark
- UCL Institute of Child Health, University College London, London, UK
| |
Collapse
|
5
|
Lawrenz M, Brassen S, Finsterbusch J. Microscopic diffusion anisotropy in the human brain: reproducibility, normal values, and comparison with the fractional anisotropy. Neuroimage 2015; 109:283-97. [PMID: 25595503 DOI: 10.1016/j.neuroimage.2015.01.025] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2014] [Revised: 01/05/2015] [Accepted: 01/06/2015] [Indexed: 11/28/2022] Open
Abstract
Human neuroimaging of tissue microstructure, such as axonal density and integrity, is key in clinical and neuroscience research. Most studies rely on diffusion tensor imaging (DTI) and the measures derived from it, most prominently fractional anisotropy (FA). However, FA also depends on fiber orientation distribution, a more macroscopic tissue property. Recently introduced measures of so-called microscopic diffusion anisotropy, diffusion anisotropy on a cellular or microscopic level, overcome this limitation because they are independent of the orientation distributions of axons and fibers. In this study, we evaluate the feasibility of two measures of microscopic diffusion anisotropy I(MA) and MA indices, for human neuroscience and clinical research. Both indices reflect the eccentricity of the cells but while I(MA) also depends on the cell size, MA is independent of the cell size and, like FA, scaled between 0 and 1. In whole-brain measurements of a group of 19 healthy volunteers, we measured average values and variability, evaluated their reproducibility, both within and between sessions, and compared MA to FA values in selected regions-of-interest (ROIs). The within- and between-session comparison did not show substantial differences but the reproducibility was much better for the MA than I(MA) (coefficient of variation between sessions 10.5% vs. 28.9%). The reproducibility was less for MA than FA overall, but comparable in the defined ROIs and the average group sizes required for between-group comparisons was similar (about 60 participants for a relative difference of 5%). Group-averaged values of MA index were generally larger and showed less variation across white-matter brain ROIs than FA (mean ± standard deviation of seven ROIs 0.83 ± 0.10 vs. 0.58 ± 0.13). Even in some gray-matter ROIs, MA values comparable to those of white matter ROIs were observed. Furthermore, the within-group variation of the values in white matter ROIs was lower for the MA compared to the FA (mean standard deviation over volunteers 0.038 vs. 0.049) which could be due to significant variability in the distribution of fiber orientation contributing to FA. These results indicate that MA (i) should be preferred to I(MA), (ii) has a reproducibility and group-size requirements comparable to those of FA; (iii) is less sensitive to the fiber orientation distribution than FA; and (iv) could be more sensitive to differences or changes of the tissue microstructure than FA. R1.1.
Collapse
Affiliation(s)
- Marco Lawrenz
- Department of Systems Neuroscience, University Medical Center Hamburg-Eppendorf, Hamburg, Germany; Neuroimage Nord, University Medical Centers Hamburg-Kiel-Lübeck, Germany
| | - Stefanie Brassen
- Department of Systems Neuroscience, University Medical Center Hamburg-Eppendorf, Hamburg, Germany; Neuroimage Nord, University Medical Centers Hamburg-Kiel-Lübeck, Germany
| | - Jürgen Finsterbusch
- Department of Systems Neuroscience, University Medical Center Hamburg-Eppendorf, Hamburg, Germany; Neuroimage Nord, University Medical Centers Hamburg-Kiel-Lübeck, Germany.
| |
Collapse
|
6
|
Lawrenz M, Finsterbusch J. Mapping measures of microscopic diffusion anisotropy in human brain white matter in vivo with double-wave-vector diffusion-weighted imaging. Magn Reson Med 2014; 73:773-83. [DOI: 10.1002/mrm.25140] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2013] [Revised: 12/12/2013] [Accepted: 01/02/2014] [Indexed: 11/07/2022]
Affiliation(s)
- Marco Lawrenz
- Department of Systems Neuroscience; University Medical Center Hamburg-Eppendorf; Hamburg Germany
- Neuroimage Nord; University Medical Centers Hamburg-Kiel-Lübeck; Germany
| | - Jürgen Finsterbusch
- Department of Systems Neuroscience; University Medical Center Hamburg-Eppendorf; Hamburg Germany
- Neuroimage Nord; University Medical Centers Hamburg-Kiel-Lübeck; Germany
| |
Collapse
|
7
|
Lawrenz M, Finsterbusch J. Detection of microscopic diffusion anisotropy on a whole-body MR system with double wave vector imaging. Magn Reson Med 2011; 66:1405-15. [DOI: 10.1002/mrm.22934] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2010] [Revised: 01/21/2011] [Accepted: 03/02/2011] [Indexed: 11/06/2022]
|
8
|
Finsterbusch J. Numerical simulations of short-mixing-time double-wave-vector diffusion-weighting experiments with multiple concatenations on whole-body MR systems. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2010; 207:274-282. [PMID: 20934360 DOI: 10.1016/j.jmr.2010.09.009] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/12/2010] [Revised: 09/14/2010] [Accepted: 09/14/2010] [Indexed: 05/30/2023]
Abstract
Double- or two-wave-vector diffusion-weighting experiments with short mixing times in which two diffusion-weighting periods are applied in direct succession, are a promising tool to estimate cell sizes in the living tissue. However, the underlying effect, a signal difference between parallel and antiparallel wave vector orientations, is considerably reduced for the long gradient pulses required on whole-body MR systems. Recently, it has been shown that multiple concatenations of the two wave vectors in a single acquisition can double the modulation amplitude if short gradient pulses are used. In this study, numerical simulations of such experiments were performed with parameters achievable with whole-body MR systems. It is shown that the theoretical model yields a good approximation of the signal behavior if an additional term describing free diffusion is included. More importantly, it is demonstrated that the shorter gradient pulses sufficient to achieve the desired diffusion weighting for multiple concatenations, increase the signal modulation considerably, e.g. by a factor of about five for five concatenations. Even at identical echo times, achieved by a shortened diffusion time, a moderate number of concatenations significantly improves the signal modulation. Thus, experiments on whole-body MR systems may benefit from multiple concatenations.
Collapse
Affiliation(s)
- Jürgen Finsterbusch
- Department of Systems Neuroscience, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
| |
Collapse
|