1
|
Hong SM, Choi CH, Felder J, Shah NJ. Novel 1H/ 19F double-tuned coil using an asymmetrical butterfly coil. Med Phys 2025. [PMID: 40387059 DOI: 10.1002/mp.17890] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2024] [Revised: 04/23/2025] [Accepted: 04/27/2025] [Indexed: 05/20/2025] Open
Abstract
BACKGROUND Fluorine-19 (19F) magnetic resonance imaging (MRI) is a non-invasive imaging tool for the targeted application of fluorinated agents, such as cell tracking, and for the demonstration of oximetry. However, as the SNR of 19F is significantly weaker than that of proton (1H) imaging, the 19F coil must be combined with 1H coils for anatomical co-registration and B0 shimming. This is difficult due to the strong coupling between the coils when they are in proximity, and is problematic since the Larmor frequency of 19F is 94% that of 1H, further increasing the potential for coupling between the 1H and 19F elements. PURPOSE Conventional double-tuned coil methods tend to generate loss compared to single-tuned reference coils. The asymmetrical butterfly coil has a split resonance peak, which can cover frequencies of 1H and 19F without losses arising from lossy traps or switching circuits. In this study, the use of an asymmetrical butterfly coil was evaluated for 1H/19F applications. METHODS To increase quadrature efficiency at both the 1H and 19F frequencies, the left and right loops of the butterfly coil were tuned asymmetrically. The coil's tuning and performance were evaluated in simulations and MR measurements, and the results were compared to a dimension-matched single-tuned loop coil. RESULTS The split resonance peak of the asymmetrical butterfly coil successfully spanned the 19F to 1H frequency. It operated with higher quadrature efficiency at both 1H and 19F frequencies and demonstrated superior receive sensitivity and SNR compared to the dimension-matched single-tuned loop coil. CONCLUSIONS The split resonance peak of the asymmetrical butterfly coil supported both 1H and 19F frequencies, delivering a higher SNR than that of the single-tuned loop coil. Since the asymmetrical butterfly coil can cover ¹H and ¹⁹F frequencies without loss and provides higher efficiency than the reference single-tuned coil, it can be effectively utilized for ¹H/¹⁹F MRI applications.
Collapse
Affiliation(s)
- Suk-Min Hong
- Institute of Neuroscience and Medicine 4, INM-4, Forschungszentrum Jülich, Jülich, Germany
| | - Chang-Hoon Choi
- Institute of Neuroscience and Medicine 4, INM-4, Forschungszentrum Jülich, Jülich, Germany
| | - Jörg Felder
- Institute of Neuroscience and Medicine 4, INM-4, Forschungszentrum Jülich, Jülich, Germany
| | - N Jon Shah
- Institute of Neuroscience and Medicine 4, INM-4, Forschungszentrum Jülich, Jülich, Germany
- Institute of Neuroscience and Medicine 11, INM-11, JARA, Forschungszentrum Jülich, Jülich, Germany
- JARA - BRAIN - Translational Medicine, Aachen, Germany
- Department of Neurology, RWTH Aachen University, Aachen, Germany
| |
Collapse
|
2
|
Ramesh TV, Narongrit FW, Rispoli JV. Adaptable, wearable, and stretchable coils: A review. Magn Reson Med 2025; 93:2186-2208. [PMID: 39902582 PMCID: PMC11893040 DOI: 10.1002/mrm.30428] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2024] [Revised: 12/18/2024] [Accepted: 12/26/2024] [Indexed: 02/05/2025]
Abstract
Over the last four decades, there have been various evolutions in the design and development of coils, from volume coils to the recent introduction of wireless receive arrays. A recent aim has been to develop coils that can closely conform to the anatomy of interest to increase the acquired signal. This goal has given rise to designs ranging from adaptable transmit coils to on-body stretchable receive arrays made using fabric or elastomer substrates. This review covers the design, fabrication details, experimental setup, and MRI results of adaptable, wearable, and stretchable MRI coils. The active and passive automatic tuning and matching strategies are examined with respect to mitigating signal-to-noise ratio reduction when the coil form is altered. A brief discussion of wireless MRI coils, which provide a solution to overcome the cabling issues associated with MRI coil development, is also included. The adaptable, wearable, and stretchable coils and various coil tuning techniques represent innovative radiofrequency coil solutions that pave the way for next-generation MRI hardware development.
Collapse
Affiliation(s)
- Thejas Vishnu Ramesh
- Weldon School of Biomedical EngineeringPurdue UniversityWest LafayetteIndianaUSA
| | - Folk W. Narongrit
- Weldon School of Biomedical EngineeringPurdue UniversityWest LafayetteIndianaUSA
- Elmore Family School of Electrical and Computer EngineeringPurdue UniversityWest LafayetteIndianaUSA
| | - Joseph V. Rispoli
- Department of Radiology and Medical ImagingUniversity of VirginiaCharlottesvilleVirginiaUSA
| |
Collapse
|
3
|
Zhang G, Jenkins P, Zhu W, Chen W, Zhu X. Simultaneous assessment of cerebral glucose and oxygen metabolism and perfusion in rats using interleaved deuterium ( 2H) and oxygen-17 ( 17O) MRS. NMR IN BIOMEDICINE 2025; 38:e5284. [PMID: 39503302 PMCID: PMC11602644 DOI: 10.1002/nbm.5284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2024] [Revised: 10/11/2024] [Accepted: 10/15/2024] [Indexed: 11/08/2024]
Abstract
Cerebral glucose and oxygen metabolism and blood perfusion play key roles in neuroenergetics and oxidative phosphorylation to produce adenosine triphosphate (ATP) energy molecules in supporting cellular activity and brain function. Their impairments have been linked to numerous brain disorders. This study aimed to develop an in vivo magnetic resonance spectroscopy (MRS) method capable of simultaneously assessing and quantifying the major cerebral metabolic rates of glucose (CMRGlc) and oxygen (CMRO2) consumption, lactate formation (CMRLac), and tricarboxylic acid (TCA) cycle (VTCA); cerebral blood flow (CBF); and oxygen extraction fraction (OEF) via a single dynamic MRS measurement using an interleaved deuterium (2H) and oxygen-17 (17O) MRS approach. We introduced a single-loop multifrequency radio-frequency (RF) surface coil that can be used to acquire proton (1H) magnetic resonance imaging (MRI) or interleaved low-γ X-nuclei 2H and 17O MRS. By combining this RF coil with a modified MRS pulse sequence, 17O-isotope-labeled oxygen gas inhalation, and intravenous 2H-isotope-labeled glucose administration, we demonstrate for the first time the feasibility of simultaneously and quantitatively measuring six important physiological parameters, CMRGlc, CMRO2, CMRLac, VTCA, CBF, and OEF, in rat brains at 16.4 T. The interleaved 2H-17O MRS technique should be readily adapted to image and study cerebral energy metabolism and perfusion in healthy and diseased brains.
Collapse
Affiliation(s)
- Guangle Zhang
- Center for Magnetic Resonance Research (CMRR), Department of RadiologyUniversity of MinnesotaMinneapolisMinnesotaUSA
| | - Parker Jenkins
- Center for Magnetic Resonance Research (CMRR), Department of RadiologyUniversity of MinnesotaMinneapolisMinnesotaUSA
| | - Wei Zhu
- Center for Magnetic Resonance Research (CMRR), Department of RadiologyUniversity of MinnesotaMinneapolisMinnesotaUSA
| | - Wei Chen
- Center for Magnetic Resonance Research (CMRR), Department of RadiologyUniversity of MinnesotaMinneapolisMinnesotaUSA
| | - Xiao‐Hong Zhu
- Center for Magnetic Resonance Research (CMRR), Department of RadiologyUniversity of MinnesotaMinneapolisMinnesotaUSA
| |
Collapse
|
4
|
Choi CH, Hong SM, Felder J, Bruch M, Worthoff WA, Krause S, Shah NJ. Design, construction, and use of a tapered-spiral, quadrature 1H/ 23Na double-tuned coil for in ovo MRI at 7 T. Med Phys 2024; 51:8761-8767. [PMID: 39382836 DOI: 10.1002/mp.17448] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2024] [Revised: 08/30/2024] [Accepted: 09/18/2024] [Indexed: 10/10/2024] Open
Abstract
BACKGROUND In ovo MR presents a promising and viable alternative to traditional in vivo small animal experiments. Sodium MRI complements proton MRI by providing potential access to tissue cellular metabolism. Despite its abundance, sodium MRI is challenged by lower MR sensitivity and faster relaxation times compared to proton MRI. Ensuring a high signal-to-noise ratio and effective B0 shimming is essential. Double-tuned coils combining 23Na and 1H are frequently employed to achieve structural imaging and efficient shim adjustment. PURPOSE This study introduces a novel, highly optimized, double-tuned coil design, specifically for MR scans of chick embryos. METHODS A tapered-spiral, double-tuned coil was designed and constructed following careful consideration of design parameters. The performance of the coil was rigorously assessed through bench tests, and final validation was conducted on a 7 T MRI scanner using a chick embryo. RESULTS Bench tests demonstrated that the return losses for both 1H and 23Na coils were better than - 30 dB, and isolation factors were better than - 21 dB, indicating that the double-tuned coil was well-set, with negligible coupling between channels. MR images of chick embryos, obtained using the coil, validated the feasibility of utilizing the design concept for in ovo applications. CONCLUSIONS The innovative design of the proposed double-tuned coil, characterized by its unique arrangement, offers improved performance. This design has the potential to significantly enhance the quality of in ovo 1H and 23Na measurements.
Collapse
Affiliation(s)
- Chang-Hoon Choi
- Institute of Neuroscience and Medicine - 4, Forschungszentrum Jülich, Juelich, Germany
- Aachen University of Applied Sciences, Jülich, Germany
| | - Suk-Min Hong
- Institute of Neuroscience and Medicine - 4, Forschungszentrum Jülich, Juelich, Germany
| | - Jörg Felder
- Institute of Neuroscience and Medicine - 4, Forschungszentrum Jülich, Juelich, Germany
- RWTH University, Aachen, Germany
| | - Maximilian Bruch
- Institute of Neuroscience and Medicine - 4, Forschungszentrum Jülich, Juelich, Germany
- Aachen University of Applied Sciences, Jülich, Germany
| | - Wieland A Worthoff
- Institute of Neuroscience and Medicine - 4, Forschungszentrum Jülich, Juelich, Germany
| | - Sandra Krause
- Institute of Neuroscience and Medicine - 4, Forschungszentrum Jülich, Juelich, Germany
| | - N Jon Shah
- Institute of Neuroscience and Medicine - 4, Forschungszentrum Jülich, Juelich, Germany
- Institute of Neuroscience and Medicine - 11, Forschungszentrum Jülich, Juelich, Germany
- JARA - BRAIN - Translational Medicine, Aachen, Germany
- Department of Neurology, RWTH Aachen University, Aachen, Germany
| |
Collapse
|
5
|
Cap V, Rocha dos Santos VR, Repnin K, Červený D, Laistler E, Meyerspeer M, Frass-Kriegl R. Combining Dipole and Loop Coil Elements for 7 T Magnetic Resonance Studies of the Human Calf Muscle. SENSORS (BASEL, SWITZERLAND) 2024; 24:3309. [PMID: 38894105 PMCID: PMC11174775 DOI: 10.3390/s24113309] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2024] [Revised: 04/26/2024] [Accepted: 05/17/2024] [Indexed: 06/21/2024]
Abstract
Combining proton and phosphorus magnetic resonance spectroscopy offers a unique opportunity to study the oxidative and glycolytic components of metabolism in working muscle. This paper presents a 7 T proton calf coil design that combines dipole and loop elements to achieve the high performance necessary for detecting metabolites with low abundance and restricted visibility, specifically lactate, while including the option of adding a phosphorus array. We investigated the transmit, receive, and parallel imaging performance of three transceiver dipoles with six pair-wise overlap-decoupled standard or twisted pair receive-only coils. With a higher SNR and more efficient transmission decoupling, standard loops outperformed twisted pair coils. The dipoles with standard loops provided a four-fold-higher image SNR than a multinuclear reference coil comprising two proton channels and 32% more than a commercially available 28-channel proton knee coil. The setup enabled up to three-fold acceleration in the right-left direction, with acceptable g-factors and no visible aliasing artefacts. Spectroscopic phantom measurements revealed a higher spectral SNR for lactate with the developed setup than with either reference coil and fewer restrictions in voxel placement due to improved transmit homogeneity. This paper presents a new use case for dipoles and highlights their advantages for the integration in multinuclear calf coils.
Collapse
Affiliation(s)
- Veronika Cap
- High Field MR Center, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, 1090 Vienna, Austria
| | - Vasco Rafael Rocha dos Santos
- High Field MR Center, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, 1090 Vienna, Austria
| | - Kostiantyn Repnin
- High Field MR Center, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, 1090 Vienna, Austria
| | - David Červený
- High Field MR Center, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, 1090 Vienna, Austria
- Institute for Clinical and Experimental Medicine, 140 21 Prague, Czech Republic
- Institute of Biophysics and Informatics, First Faculty of Medicine, Charles University, 121 08 Prague, Czech Republic
| | - Elmar Laistler
- High Field MR Center, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, 1090 Vienna, Austria
| | - Martin Meyerspeer
- High Field MR Center, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, 1090 Vienna, Austria
| | - Roberta Frass-Kriegl
- High Field MR Center, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, 1090 Vienna, Austria
| |
Collapse
|
6
|
Paška J, Wang B, Chen AM, Madelin G, Brown R. Triple-tuned birdcage and single-tuned dipole array for quadri-nuclear head MRI at 7 T. Magn Reson Med 2024; 91:2188-2199. [PMID: 38116692 PMCID: PMC10950522 DOI: 10.1002/mrm.29977] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Revised: 10/31/2023] [Accepted: 11/28/2023] [Indexed: 12/21/2023]
Abstract
PURPOSE The purpose of this work was to design and build a coil for quadri-nuclear MRI of the human brain at 7 T. METHODS We built a transmit/receive triple-tuned (45.6 MHz for 2 $$ {}^2 $$ H, 78.6 MHz for 23 $$ {}^{23} $$ Na, and 120.3 MHz for 31 $$ {}^{31} $$ P) quadrature four-rod birdcage that was geometrically interleaved with a transmit/receive four-channel dipole array (297.2 MHz for 1 $$ {}^1 $$ H). The birdcage rods contained passive, two-pole resonant circuits that emulated capacitors required for single-tuning at three frequencies. The birdcage assembly also included triple-tuned matching networks, baluns, and transmit/receive switches. We assessed the performance of the coil with quality factor (Q) and signal-to-noise ratio (SNR) measurements, and performed in vivo multinuclear MRI and MR spectroscopic imaging (MRSI). RESULTS Q measurements showed that the triple-tuned birdcage efficiency was within 33% of that of single-tuned baseline birdcages at all three frequencies. The quadri-tuned coil SNR was 78%, 59%, 44%, and 48% lower than that of single or dual-tuned reference coils for 1 $$ {}^1 $$ H, 2 $$ {}^2 $$ H, 23 $$ {}^{23} $$ Na, and 31 $$ {}^{31} $$ P, respectively. Quadri-nuclear MRI and MRSI was demonstrated in brain in vivo in about 30 min. CONCLUSION While the SNR of the quadruple tuned coil was significantly lower than dual- and single-tuned reference coils, it represents a step toward truly simultaneous quadri-nuclear measurements.
Collapse
Affiliation(s)
- Jan Paška
- Center for Advanced Imaging Innovation and Research, Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States
- Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States
| | - Bili Wang
- Center for Advanced Imaging Innovation and Research, Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States
- Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States
| | - Anna M. Chen
- Center for Advanced Imaging Innovation and Research, Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States
- Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States
| | - Guillaume Madelin
- Center for Advanced Imaging Innovation and Research, Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States
- Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States
| | - Ryan Brown
- Center for Advanced Imaging Innovation and Research, Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States
- Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States
| |
Collapse
|
7
|
Touchet-Valle E, Tasmim S, Ware TH, McDougall MP. Evaluation of Low-Loss Polymer Switches for Multinuclear MRI/S . ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2023; 2023:1-5. [PMID: 38083302 DOI: 10.1109/embc40787.2023.10340712] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
Implementation of multinuclear MRI/S as a diagnostic tool in clinical settings faces many challenges. One of those challenges is the development of highly sensitive multinuclear RF coils. Current multi-tuning techniques incorporate lossy components that impact the highest achievable SNR for at least one of the coil frequencies. As a result, optimization of multinuclear coil designs continues to be a priority for RF hardware engineers. To address this challenge, a new frequency switching technology that incorporates stimuli-responsive polymer materials was explored. Q measurements were used as a comparison metric between single-tuned, a standard switching network, and the proposed switching technology. The Q losses measured in the new switching method remained below 38% when compared to single-tuned coils. These results are consistent with low loss values reported using traditional switching networks. Furthermore, preliminary testing indicates that there is potential for improvement. These results establish the new technology as a promising alternative to traditional switching techniques.Clinical Relevance- A low loss multi-tuning technique for MRI radiofrequency coils has the potential of improving the study and diagnosis of disease.
Collapse
|
8
|
Selvaganesan K, Wan Y, Ha Y, Wu B, Hancock K, Galiana G, Constable RT. Magnetic resonance imaging using a nonuniform Bo (NuBo) field-cycling magnet. PLoS One 2023; 18:e0287344. [PMID: 37319289 PMCID: PMC10270621 DOI: 10.1371/journal.pone.0287344] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Accepted: 06/02/2023] [Indexed: 06/17/2023] Open
Abstract
Magnetic resonance imaging (MRI) is a powerful noninvasive diagnostic tool with superior soft tissue contrast. However, access to MRI is limited since current systems depend on homogeneous, high field strength main magnets (B0-fields), with strong switchable gradients which are expensive to install and maintain. In this work we propose a new approach to MRI where imaging is performed in an inhomogeneous field using radiofrequency spatial encoding, thereby eliminating the need for uniform B0-fields and conventional cylindrical gradient coils. The proposed technology uses an innovative data acquisition and reconstruction approach by integrating developments in field cycling, parallel imaging and non-Fourier based algebraic reconstruction. The scanner uses field cycling to image in an inhomogeneous B0-field; in this way magnetization is maximized during the high field polarization phase, and B0 inhomogeneity effects are minimized by using a low field during image acquisition. In addition to presenting the concept, this work provides experimental verification of a long-lived spin echo signal, spatially varying resolution, as well as both simulated and experimental 2D images. Our initial design creates an open MR system that can be installed in a patient examination table for body imaging (e.g., breast or liver) or built into a wall for weighted-spine imaging. The proposed system introduces a new class of inexpensive, open, silent MRIs that could be housed in doctor's offices much like ultrasound is today, making MRI more widely accessible.
Collapse
Affiliation(s)
- Kartiga Selvaganesan
- Department of Biomedical Engineering, Yale University, New Haven, CT, United States of America
| | - Yuqing Wan
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, New Haven, CT, United States of America
| | - Yonghyun Ha
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, New Haven, CT, United States of America
| | - Baosong Wu
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, New Haven, CT, United States of America
| | - Kasey Hancock
- Department of Electrical Engineering, Yale University, New Haven, CT, United States of America
| | - Gigi Galiana
- Department of Biomedical Engineering, Yale University, New Haven, CT, United States of America
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, New Haven, CT, United States of America
| | - R. Todd Constable
- Department of Biomedical Engineering, Yale University, New Haven, CT, United States of America
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, New Haven, CT, United States of America
| |
Collapse
|
9
|
Özen AC, Spreter F, Schimpf W, Fischer J, Ilbey S, Reiss S, Maier A, von Elverfeldt D, Heidt T, von Zur Mühlen C, Bock M. Scalable and modular 8-channel transmit and 8-channel flexible receive coil array for 19 F MRI of large animals. Magn Reson Med 2023; 89:1237-1250. [PMID: 36226654 DOI: 10.1002/mrm.29490] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Revised: 09/23/2022] [Accepted: 09/24/2022] [Indexed: 02/02/2023]
Abstract
PURPOSE To introduce an RF coil system consisting of an 8-channel transmit (Tx) and 8-channel receive (Rx) coil arrays for 19 F MRI of large animals. METHODS The Tx efficiency and homogeneity of the 8-element loop coil array (loop size: 6 × 15 cm2 ) were simulated for two different pig models rendered from MR images. An 8-channel Rx coil array consisting of a flexible 6-channel posterior and a 2-channel planar anterior array was designed to fit on the abdomen of an average-sized pig in supine position. Measurements were performed in a grid phantom and ex vivo on a pig model with perfluoroctylbromide (PFOB)-filled tubes inserted in the thorax. RESULTS Measured and simulated Tx efficiency and homogeneity for the 8-channel and 5-channel arrays were in good agreement: 1.87 ± 0.22μT/√kW versus 1.96 ± 0.29μT/√kW, and 2.29 ± 0.39μT/√kW versus 2.41 ± 0.37μT/√kW. An isolation of 38 ± 8 dB is achieved between the 19 F Tx and Rx elements, and over 30 dB between the 1 H and 19 F elements. The PFOB-filled vials could be clearly identified within the cadaver abdomen with an SNR of 275 ± 51 for a 3D gradient-echo sequence with 2-mm isotropic resolution and 12 averages, acquired in 9:52 min:s. Performance of the Tx array was robust against phase and amplitude mismatches at the input ports. CONCLUSIONS A modular and scalable Tx array offers improved Tx efficiency in 19 F MRI of large animals with various sizes. Although conventional birdcage coils have superior Tx efficiency within the target region of interest, scalability of the Tx array to animal size is a major benefit. The described 19 F coil provides homogeneous excitation and high sensitivity detection in large pig models.
Collapse
Affiliation(s)
- Ali Caglar Özen
- Department of Radiology, Medical Physics, Medical Center-University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Felix Spreter
- Department of Radiology, Medical Physics, Medical Center-University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Waldemar Schimpf
- Department of Radiology, Medical Physics, Medical Center-University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Johannes Fischer
- Department of Radiology, Medical Physics, Medical Center-University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Serhat Ilbey
- Department of Radiology, Medical Physics, Medical Center-University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Simon Reiss
- Department of Radiology, Medical Physics, Medical Center-University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Alexander Maier
- Department of Cardiology and Angiology I, University Heart Center, Medical Center-University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Dominik von Elverfeldt
- Department of Radiology, Medical Physics, Medical Center-University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Timo Heidt
- Department of Cardiology and Angiology I, University Heart Center, Medical Center-University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Constantin von Zur Mühlen
- Department of Cardiology and Angiology I, University Heart Center, Medical Center-University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Michael Bock
- Department of Radiology, Medical Physics, Medical Center-University of Freiburg, University of Freiburg, Freiburg, Germany
| |
Collapse
|
10
|
Wang B, Zhang B, Yu Z, Ianniello C, Lakshmanan K, Paska J, Madelin G, Cloos M, Brown R. A radially interleaved sodium and proton coil array for brain MRI at 7 T. NMR IN BIOMEDICINE 2021; 34:e4608. [PMID: 34476861 PMCID: PMC9362999 DOI: 10.1002/nbm.4608] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2020] [Revised: 08/09/2021] [Accepted: 08/11/2021] [Indexed: 06/13/2023]
Abstract
The objective of the current study was to design and build a dual-tuned coil array for simultaneous 23 Na/1 H MRI of the human brain at 7 T. Quality factor, experimental B1+ measurements, and electromagnetic simulations in prototypes showed that setups consisting of geometrically interleaved 1 H and 23 Na loops performed better than or similar to 1 H or 23 Na loops in isolation. Based on these preliminary findings, we built a transmit/receive eight-channel 23 Na loop array that was geometrically interleaved with a transmit/receive eight-channel 1 H loop array. We assessed the performance of the manufactured array with mononuclear signal-to-noise ratio (SNR) and B1+ measurements, along with multinuclear magnetic resonance fingerprinting maps and images. The 23 Na array within the developed dual-tuned device provided more than 50% gain in peripheral SNR and similar B1+ uniformity and coverage as a reference birdcage coil of similar size. The 1 H array provided good B1+ uniformity in the brain, excluding the cerebellum and brain stem. The integrated 23 Na and 1 H arrays were used to demonstrate truly simultaneous quantitative 1 H mapping and 23 Na imaging.
Collapse
Affiliation(s)
- Bili Wang
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
- Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
| | - Bei Zhang
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
- Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
- Advanced Imaging Research Center, Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Zidan Yu
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
- Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
- Vilcek Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York, USA
| | - Carlotta Ianniello
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
- Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
- Vilcek Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York, USA
| | - Karthik Lakshmanan
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
- Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
| | - Jan Paska
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
- Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
| | - Guillaume Madelin
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
- Vilcek Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York, USA
| | - Martijn Cloos
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
- Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
- Vilcek Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York, USA
- Centre for Advanced Imaging, The University of Queensland, St Lucia, Brisbane, Queensland, Australia
| | - Ryan Brown
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
- Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
- Vilcek Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York, USA
| |
Collapse
|
11
|
Celik AA, Choi CH, Tellmann L, Rick C, Shah NJ, Felder J. Design and Construction of a PET-Compatible Double-Tuned 1H/ 31P MR Head Coil. IEEE TRANSACTIONS ON MEDICAL IMAGING 2021; 40:2015-2022. [PMID: 33798075 DOI: 10.1109/tmi.2021.3070626] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Simultaneous MR-PET is an increasingly popular multimodal imaging technique that is able to combine metabolic information obtained from PET with anatomical/functional information from MRI. One of the key technological challenges of the technique is the integration of a PET-transparent MR coil system, a solution to which is demonstrated here for a double-tuned 1H/31P head coil at 3 T. Two single-resonant birdcage coils tuned to the 1H and 31P resonances were arranged in an interleaved fashion and electrically decoupled with the use of trap circuits. All high 511 keV quanta absorbing components were arranged outside the PET field-of-view in order to minimize count rate reduction. The materials inside the PET field-of-view were carefully evaluated and chosen for minimum impact on the PET image quality. As far as possible, the coil case was geometrically optimized to avoid sharp transitions in attenuation, which may potentially result in streaking artefacts during PET image reconstruction. The coil caused a count rate loss of just above 5% when inserted into the PET detector ring. Except for the anterior region, which was designed to maintain free openings for increased patient comfort, an almost uniform distribution of 511 keV attenuation was maintained around the circumference of the coil. MR-related performance for both nuclei was similar or slightly better than that of a commercial double-tuned coil, despite the MR-PET coil having a close-fitting RF screen to shield the PET and MR electronics from possible electromagnetic interferences.
Collapse
|
12
|
Wilcox M, Wright SM, McDougall M. A Review of Non- 1H RF Receive Arrays in Magnetic Resonance Imaging and Spectroscopy. IEEE OPEN JOURNAL OF ENGINEERING IN MEDICINE AND BIOLOGY 2020; 1:290-300. [PMID: 35402958 PMCID: PMC8975242 DOI: 10.1109/ojemb.2020.3030531] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2020] [Revised: 09/15/2020] [Accepted: 09/25/2020] [Indexed: 11/16/2022] Open
Abstract
It is now common practice to use radiofrequency (RF) coils to increase the signal-to-noise ratio (SNR) in 1H magnetic resonance imaging and spectroscopy experiments. Use of array coils for non-1H experiments, however, has been historically more limited despite the fact that these nuclei suffer inherently lower sensitivity and could benefit greatly from an increased SNR. Recent advancements in receiver technology and increased support from scanner manufacturers have now opened greater options for the use of array coils for non-1H magnetic resonance experiments. This paper reviews the research in adopting array coil technology with an emphasis on studies of the most commonly studied non-1H nuclei including 31P, 13C, 23Na, and 19F. These nuclei offer complementary information to 1H imaging and spectroscopy and have proven themselves important in the study of numerous disease processes. While recent work with non-1H array coils has shown promising results, the technology is not yet widely utilized and should see substantial developments in the coming years.
Collapse
|
13
|
Choi CH, Hong SM, Felder J, Shah NJ. The state-of-the-art and emerging design approaches of double-tuned RF coils for X-nuclei, brain MR imaging and spectroscopy: A review. Magn Reson Imaging 2020; 72:103-116. [DOI: 10.1016/j.mri.2020.07.003] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Revised: 06/16/2020] [Accepted: 07/01/2020] [Indexed: 12/18/2022]
|
14
|
Fantasia M, Galante A, Maggiorelli F, Retico A, Fontana N, Monorchio A, Alecci M. Numerical and Workbench Design of 2.35 T Double-Tuned (¹H/²³Na) Nested RF Birdcage Coils Suitable for Animal Size MRI. IEEE TRANSACTIONS ON MEDICAL IMAGING 2020; 39:3175-3186. [PMID: 32310762 DOI: 10.1109/tmi.2020.2988599] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
The birdcage Radio Frequency (RF) coil is one of the most used configurations in Magnetic Resonance Imaging (MRI) scanners for the detection of the proton (1H) signal over a large homogeneous volume. More recently, birdcage RF coils have been successfully used also in the field of X-nuclei MRI, where the signal of a second nucleus (e.g. 13C, 23Na, 31P, and many others) needs to be detected with high sensitivity and spatial homogeneity. To this purpose several technical solutions have been adopted to design Double Tuned (DT) volume RF coils, including the recent configuration of the nested birdcage RF coils. One of the main problems in the design of DT RF coils is the decoupling between the 1H and X channels, and a number of solutions have been adopted over the years. In this work, based on numerical and workbench methods, we report the decoupling optimization of DT (1H/23Na) nested RF birdcage coils suitable for 2.35 T MRI scanners encompassing an inner Low-Pass (LP) birdcage used for X-nuclei, an outer High-Pass (HP) birdcage for 1H and an external cylindrical RF shield. We show that a suitable geometrical selection of the two coaxial RF birdcage coils (relative angular orientation, diameters and lengths) and RF shield (diameter, length) allows a significant decoupling optimization. We also provide valuable information about the RF B1+ field homogeneity and efficiency. Our approach was validated both with numerical simulations and workbench testing using DT nested RF coil prototypes.
Collapse
|
15
|
Choi CH, Stegmayr C, Shymanskaya A, Worthoff WA, da Silva NA, Felder J, Langen KJ, Shah NJ. An in vivo multimodal feasibility study in a rat brain tumour model using flexible multinuclear MR and PET systems. EJNMMI Phys 2020; 7:50. [PMID: 32728773 PMCID: PMC7391464 DOI: 10.1186/s40658-020-00319-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2020] [Accepted: 07/12/2020] [Indexed: 11/16/2022] Open
Abstract
Background In addition to the structural information afforded by 1H MRI, the use of X-nuclei, such as sodium-23 (23Na) or phosphorus-31 (31P), offers important complementary information concerning physiological and biochemical parameters. By then combining this technique with PET, which provides valuable insight into a wide range of metabolic and molecular processes by using of a variety of radioactive tracers, the scope of medical imaging and diagnostics can be significantly increased. While the use of multimodal imaging is undoubtedly advantageous, identifying the optimal combination of these parameters to diagnose a specific dysfunction is very important and is advanced by the use of sophisticated imaging techniques in specific animal models. Methods In this pilot study, rats with intracerebral 9L gliosarcomas were used to explore a combination of sequential multinuclear MRI using a sophisticated switchable coil set in a small animal 9.4 T MRI scanner and, subsequently, a small animal PET with the tumour tracer O-(2-[18F]-fluoroethyl)-L-tyrosine ([18F]FET). This made it possible for in vivo multinuclear MR-PET experiments to be conducted without compromising the performance of either multinuclear MR or PET. Results High-quality in vivo images and spectra including high-resolution 1H imaging, 23Na-weighted imaging, detection of 31P metabolites and [18F]FET uptake were obtained, allowing the characterisation of tumour tissues in comparison to a healthy brain. It has been reported in the literature that these parameters are useful in the identification of the genetic profile of gliomas, particularly concerning the mutation of the isocitrate hydrogenase gene, which is highly relevant for treatment strategy. Conclusions The combination of multinuclear MR and PET in, for example, brain tumour models with specific genetic mutations will enable the physiological background of signal alterations to be explored and the identification of the optimal combination of imaging parameters for the non-invasive characterisation of the molecular profile of tumours.
Collapse
Affiliation(s)
- Chang-Hoon Choi
- Institute of Neuroscience and Medicine-4, INM-4, Forschungszentrum Jülich, Germany
| | - Carina Stegmayr
- Institute of Neuroscience and Medicine-4, INM-4, Forschungszentrum Jülich, Germany
| | | | - Wieland A Worthoff
- Institute of Neuroscience and Medicine-4, INM-4, Forschungszentrum Jülich, Germany
| | - Nuno A da Silva
- Institute of Neuroscience and Medicine-4, INM-4, Forschungszentrum Jülich, Germany
| | - Jörg Felder
- Institute of Neuroscience and Medicine-4, INM-4, Forschungszentrum Jülich, Germany
| | - Karl-Josef Langen
- Institute of Neuroscience and Medicine-4, INM-4, Forschungszentrum Jülich, Germany.,Department of Nuclear Medicine, RWTH Aachen University Hospital, Aachen, Germany.,Jülich-Aachen Research Alliance (JARA)-Section JARA-BRAIN, Aachen, Germany
| | - N Jon Shah
- Institute of Neuroscience and Medicine-4, INM-4, Forschungszentrum Jülich, Germany. .,Institute of Neuroscience and Medicine-11, INM-11, JARA, Forschungszentrum Jülich, Germany. .,JARA-BRAIN-Translational Medicine, Aachen, Germany. .,Department of Neurology, RWTH Aachen University, Aachen, Germany.
| |
Collapse
|
16
|
Davoodi H, Jouda M, Korvink JG, MacKinnon N, Badilita V. Broadband and multi-resonant sensors for NMR. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2019; 112-113:34-54. [PMID: 31481158 DOI: 10.1016/j.pnmrs.2019.05.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2019] [Revised: 05/08/2019] [Accepted: 05/08/2019] [Indexed: 06/10/2023]
Abstract
It has always been of considerable interest to study the nuclear magnetic resonance response of multiple nuclei simultaneously, whether these signals arise from internuclear couplings within the same molecule, or from uncoupled nuclei within sample mixtures. The literature contains numerous uncorrelated reports on techniques employed to achieve multi-nuclear NMR detection. This paper consolidates the subset of techniques in which single coil detectors are utilized, and highlights the strengths and weaknesses of each approach, at the same time pointing the way towards future developments in the field of multi-nuclear NMR. We compare the different multi-nuclear NMR techniques in terms of performance, and present a guide to NMR probe designers towards application-based optimum design. We also review the applicability of micro-coils in the context of multi-nuclear methods. Micro-coils benefit from compact geometries and exhibit lower impedance, which provide new opportunities and challenges for the NMR probe designer.
Collapse
Affiliation(s)
- Hossein Davoodi
- Institute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Baden-Württemberg, Germany
| | - Mazin Jouda
- Institute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Baden-Württemberg, Germany
| | - Jan G Korvink
- Institute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Baden-Württemberg, Germany.
| | - Neil MacKinnon
- Institute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Baden-Württemberg, Germany
| | - Vlad Badilita
- Institute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Baden-Württemberg, Germany.
| |
Collapse
|
17
|
Maunder A, Rao M, Robb F, Wild JM. Comparison of MEMS switches and PIN diodes for switched dual tuned RF coils. Magn Reson Med 2018; 80:1746-1753. [PMID: 29524235 PMCID: PMC6120476 DOI: 10.1002/mrm.27156] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2017] [Revised: 02/05/2018] [Accepted: 02/05/2018] [Indexed: 11/12/2022]
Abstract
PURPOSE To evaluate the performance of micro-electromechanical systems (MEMS) switches against PIN diodes for switching a dual-tuned RF coil between 19 F and 1 H resonant frequencies for multi-nuclear lung imaging. METHODS A four-element fixed-phase and amplitude transmit-receive RF coil was constructed to provide homogeneous excitation across the lungs, and to serve as a test system for various switching methods. The MR imaging and RF performance of the coil when switched between the 19 F and 1 H frequencies using MEMS switches, PIN diodes and hardwired configurations were compared. RESULTS The performance of the coil with MEMS or PIN diode switching was comparable in terms of RF measurements, transmit efficiency and image SNR on both 19 F and 1 H nuclei. When the coil was not switched to the resonance frequency of the respective nucleus being imaged, reductions in the transmit efficiency were observed of 32% at the 19 F frequency and 12% at the 1 H frequency. The coil provides transmit field homogeneity of ±12.9% at the 1 H frequency and ±14.4% at the 19 F frequency in phantoms representing the thorax with the air space of the lungs filled with perfluoropropane gas. CONCLUSION MEMS and PIN diodes were found to provide comparable performance in on-state configuration, while MEMS were more robust in off-state high-powered operation (>1 kW), providing higher isolation and requiring a lower DC switching voltage than is needed for reverse biasing of PIN diodes. In addition, clear benefits of switching between the 19 F and 1 H resonances were demonstrated, despite the proximity of their Larmor frequencies.
Collapse
Affiliation(s)
- Adam Maunder
- Unit of Academic Radiology, University of SheffieldUnited Kingdom
| | - Madhwesha Rao
- Unit of Academic Radiology, University of SheffieldUnited Kingdom
| | - Fraser Robb
- Unit of Academic Radiology, University of SheffieldUnited Kingdom
- GE HealthcareAuroraOhio
| | - Jim M. Wild
- Unit of Academic Radiology, University of SheffieldUnited Kingdom
| |
Collapse
|
18
|
Ha Y, Choi CH, Shah NJ. Development and Implementation of a PIN-Diode Controlled, Quadrature-Enhanced, Double-Tuned RF Coil for Sodium MRI. IEEE TRANSACTIONS ON MEDICAL IMAGING 2018; 37:1626-1631. [PMID: 29969413 DOI: 10.1109/tmi.2017.2786466] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Sodium (23Na) MRI provides complementary cellular and metabolic information. However, the intrinsic MR sensitivity of 23Na is considerably lower compared with that of the proton, making it difficult to measure MR-detectable sodium signals. It is therefore important to maintain the signal-to-noise ratio (SNR) of the sodium signal as high as possible. Double-tuned coils are often employed in combinationwith a 1H coil, providing structural images and B0 shimming capability. The double-tuned coil design can be achieved with the use of two geometrically decoupled coils whose B1 field directions are perpendicular to each other. This can be used to design quadrature-driven, single-nucleus coils to improve SNR, and additionally, this coil can also be utilized as a linear-driven double-resonant mode. Here, we have developed and evaluateda quadrature-enhanced, double-tuned coil. The novel coil uses PIN-diode switches, inserted only in the loop coil, to shift the resonance frequency between 1H and 23Na so that 23Na signals can be acquired in quadrature and the capability of using 1H function remains. Consequently, the 23Na SNR values obtained with the double-tuned coil are nearly 33% and 17% higher in comparison with geometrically identical single-tuned coils. SNR plots also show the superiority of double-tuned coil in 23Na.
Collapse
|