Han R, Borcik CG, Wang S, Warmuth OA, Geohring K, Mullen C, Incitti M, Stringer JA, Rienstra CM. Solid-State NMR 13C sensitivity at high magnetic field. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2024; 365:107709. [PMID: 38991265 PMCID: PMC11391299 DOI: 10.1016/j.jmr.2024.107709] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2023] [Revised: 06/05/2024] [Accepted: 06/06/2024] [Indexed: 07/13/2024]
Abstract
Sensitivity is the foundation of every NMR experiment, and the signal-to-noise ratio (SNR) should increase with static (B0) magnetic field, by a proportionality that primarily depends on the design of the NMR probe and receiver. In the low B0 field limit, where the coil geometry is much smaller than the wavelength of the NMR frequency, SNR can increase in proportion to B0 to the power 7/4. For modern magic-angle spinning (MAS) probes, this approximation holds for rotor sizes up to 3.2 mm at 14.1 Tesla (T), corresponding to 600 MHz 1H and 151 MHz 13C Larmor frequencies. To obtain the anticipated benefit of larger coils and/or higher B0 fields requires a quantitative understanding of the contributions to SNR, utilizing standard samples and protocols that reproduce SNR measurements with high accuracy and precision. Here, we present such a systematic and comprehensive study of 13C SNR under MAS over the range of 14.1 to 21.1 T. We evaluate a range of probe designs utilizing 1.6, 2.5 and 3.2 mm rotors, including 24 different sets of measurements on 17 probe configurations using five spectrometers. We utilize N-acetyl valine as the primary standard and compare and contrast with other commonly used standard samples (adamantane, glycine, hexamethylbenzene, and 3-methylglutaric acid). These robust approaches and standard operating procedures provide an improved understanding of the contributions from probe efficiency, receiver noise figure, and B0 dependence in a range of custom-designed and commercially available probes. We find that the optimal raw SNR is obtained with balanced 3.2 mm design at 17.6 T, that the best mass-limited SNR is achieved with a balanced 1.6 mm design at 21.1 T, and that the raw SNR at 21.1 T reaches diminishing returns with rotors larger than 2.5 mm.
Collapse
Affiliation(s)
- Ruixian Han
- Department of Chemistry, University of Wisconsin-Madison, Madison, WI, United States
| | - Collin G Borcik
- Department of Biochemistry, University of Wisconsin-Madison, Madison, WI, United States
| | - Songlin Wang
- National Magnetic Resonance Facility at Madison (NMRFAM), University of Wisconsin-Madison, Madison, WI, United States
| | - Owen A Warmuth
- Department of Biochemistry, University of Wisconsin-Madison, Madison, WI, United States
| | | | | | | | | | - Chad M Rienstra
- Department of Chemistry, University of Wisconsin-Madison, Madison, WI, United States; Department of Biochemistry, University of Wisconsin-Madison, Madison, WI, United States; National Magnetic Resonance Facility at Madison (NMRFAM), University of Wisconsin-Madison, Madison, WI, United States.
| |
Collapse
|
2
|
Schönzart J, Han R, Gennett T, Rienstra CM, Stringer JA. Magnetic Susceptibility Modeling of Magic-Angle Spinning Modules for Part Per Billion Scale Field Homogeneity. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2024; 364:107704. [PMID: 38879926 DOI: 10.1016/j.jmr.2024.107704] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2024] [Revised: 05/17/2024] [Accepted: 05/18/2024] [Indexed: 06/18/2024]
Abstract
Magic-angle spinning (MAS) solid-state NMR methods are crucial in many areas of biology and materials science. Conventional probe designs have often been specified with 0.1 part per million (ppm) or 100 part per billion (ppb) magnetic field resolution, which is a limitation for many modern scientific applications. Here we describe a novel 5-mm MAS module design that significantly improves the linewidth and line shape for solid samples by an improved understanding of the magnetic susceptibility of probe materials and geometrical symmetry considerations, optimized to minimize the overall perturbation to the applied magnetic field (B0). The improved spinning module requires only first and second order shimming adjustments to achieve a sub-Hz resolution of 13C resonances of adamantane at 150 MHz Larmor frequency (14.1Tesla magnetic field). Minimal use of third and higher order shims improves experimental reproducibility upon sample changes and the exact placement within the magnet. Furthermore, the shimming procedure is faster, and the required gradients smaller, thus minimizing thermal drift of the room temperature (RT) shims. We demonstrate these results with direct polarization (Bloch decay) and cross polarization experiments on adamantane over a range of sample geometries and with multiple superconducting magnet systems. For a direct polarization experiment utilizing the entire active sample volume of a 5-mm rotor (90 µl), we achieved full width at half maximum (FWHM) of 0.76 Hz (5 ppb) and baseline resolved the 13C satellite peaks for adamantane as a consequent of the 7.31 Hz (59 ppb) width at 2% intensity. We expect these approaches to be increasingly pivotal for high-resolution solid-state NMR spectroscopy at and above 1 GHz 1H frequencies.
Collapse
Affiliation(s)
- Jasmin Schönzart
- Department of Chemistry, Colorado School of Mines, Golden, CO 80501, USA; PhoenixNMR, LLC, Loveland, CO 80503, USA.
| | - Ruixian Han
- Department of Chemistry, University of Wisconsin -Madison, Madison, WI 53706, USA
| | - Thomas Gennett
- Department of Chemistry, Colorado School of Mines, Golden, CO 80501, USA
| | - Chad M Rienstra
- Department of Chemistry, University of Wisconsin -Madison, Madison, WI 53706, USA; Department of Biochemistry, University of Wisconsin -Madison, Madison, WI 53706, USA; National Magnetic Resonance Facility at Madison, University of Wisconsin - Madison Madison, WI 53706, USA
| | - John A Stringer
- Department of Chemistry, Colorado School of Mines, Golden, CO 80501, USA; PhoenixNMR, LLC, Loveland, CO 80503, USA.
| |
Collapse
|
3
|
Kelz JI, Uribe JL, Martin RW. Reimagining magnetic resonance instrumentation using open maker tools and hardware as protocol. JOURNAL OF MAGNETIC RESONANCE OPEN 2021; 6-7:100011. [PMID: 34085051 PMCID: PMC8171197 DOI: 10.1016/j.jmro.2021.100011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Over the course of its history, the field of nuclear magnetic resonance spectroscopy has been characterized by alternating periods of intensive instrumentation development and rapid expansion into new chemical application areas. NMR is now both a mainstay of routine analysis for laboratories at all levels of education and research. On the other hand, new instrumentation and methodological advances promise expanded functionality in the future. At the core of this success is a community fundamentally dedicated to sharing ideas and collaborative advancements, as exemplified by the extensive remixing and repurposing of pulse sequences. Recent progress in modularity, automation, and 3D printing have reignited the tinkering spirit and demonstrate great promise to mature into a maker space that will enable similarly facile sharing of new applications and broader access to magnetic resonance.
Collapse
Affiliation(s)
- Jessica I. Kelz
- Department of Chemistry, University of California, Irvine 92697-2025
| | - Jose L. Uribe
- Department of Chemistry, University of California, Irvine 92697-2025
| | - Rachel W. Martin
- Department of Chemistry, University of California, Irvine 92697-2025
- Department of Molecular Biology and Biochemistry, University of California, Irvine 92697-3900
| |
Collapse
|
4
|
Untuned broadband spiral micro-coils achieve sensitive multi-nuclear NMR TX/RX from microfluidic samples. Sci Rep 2021; 11:7798. [PMID: 33833324 PMCID: PMC8032710 DOI: 10.1038/s41598-021-87247-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Accepted: 03/22/2021] [Indexed: 11/17/2022] Open
Abstract
The low frequency plateau in the frequency response of an untuned micro-resonator permits broadband radio-frequency reception, albeit at the expense of optimal signal-to-noise ratio for a particular nucleus. In this contribution we determine useful figures of merit for broadband micro-coils, and thereby explore the parametric design space towards acceptable simultaneous excitation and reception of a microfluidic sample over a wide frequency band ranging from 13C to 1H, i.e., 125–500 MHz in an 11.74 T magnet. The detector achieves 37% of the performance of a comparably sized, tuned and matched resonator, and a linewidth of 17 ppb using standard magnet shims. The use of broadband detectors circumvents numerous difficulties introduced by multi-resonant RF detector circuits, including sample loading effects on matching, channel isolation, and field distortion.
Collapse
|
5
|
A Novel Fault Diagnosis Method for High-Temperature Superconducting Field Coil of Superconducting Rotating Machine. APPLIED SCIENCES-BASEL 2019. [DOI: 10.3390/app10010223] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
In this paper, a new method is presented for sensitive quench detection in high-temperature superconductor (HTS) rotating machinery. The normal zone propagation velocity of an HTS is about 1000 times slower than that of a low-temperature superconductor. Therefore, the propagation of normal zone resistance, which occurs when the HTS transits from the superconducting state to the normal state, is also slower. Thus, it is difficult to detect the abnormal signals by voltage measurement using voltage taps. Moreover, the monitoring signal includes noise generated by interaction between the HTS rotating machinery and the industrial environment. Therefore, when quenching occurs in the HTS rotating machinery, a thermal runaway occurs in the hot spot. Furthermore, the magnetic energy stored in the HTS coil can damage the machinery. For these reasons, a new method is proposed for sensitive quench detection that reduces the noise generated from the power supply and from the HTS rotating machinery, using both an RLC resonance circuit and fast Fourier transform analysis.
Collapse
|
6
|
Reese M, George C, Yang C, Jawla S, Grün JT, Schwalbe H, Redfield C, Temkin RJ, Griffin RG. Modular, triple-resonance, transmission line DNP MAS probe for 500 MHz/330 GHz. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2019; 307:106573. [PMID: 31505305 PMCID: PMC6766420 DOI: 10.1016/j.jmr.2019.106573] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/03/2019] [Revised: 08/12/2019] [Accepted: 08/13/2019] [Indexed: 06/10/2023]
Abstract
We describe the design and construction of a modular, triple-resonance, fully balanced, DNP-MAS probe based on transmission line technology and its integration into a 500 MHz/330 GHz DNP-NMR spectrometer. A novel quantitative probe design and characterization strategy is developed and employed to achieve optimal sensitivity, RF homogeneity and excellent isolation between channels. The resulting three channel HCN probe has a modular design with each individual, swappable module being equipped with connectorized, transmission line ports. This strategy permits attachment of a mating connector that facilitates accurate impedance measurements at these ports and allows characterization and adjustment (e.g. for balancing or tuning/matching) of each component individually. The RF performance of the probe is excellent; for example, the 13C channel attains a Rabi frequency of 280 kHz for a 3.2 mm rotor. In addition, a frequency tunable 330 GHz gyrotron operating at the second harmonic of the electron cyclotron frequency was developed for DNP applications. Careful alignment of the corrugated waveguide led to minimal loss of the microwave power, and an enhancement factor ε = 180 was achieved for U-13C urea in the glassy matrix at 80 K. We demonstrated the operation of the system with acquisition of multidimensional spectra of cross-linked lysozyme crystals which are insoluble in glycerol-water mixtures used for DNP and samples of RNA.
Collapse
Affiliation(s)
- Marcel Reese
- Department of Chemistry and Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, United States
| | - Christy George
- Department of Chemistry and Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, United States
| | - Chen Yang
- Department of Chemistry and Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, United States
| | - Sudheer Jawla
- Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139, United States
| | - J Tassilo Grün
- Institute for Organic Chemistry and Chemical Biology, Center for Biomolecular Magnetic Resonance, Johann Wolfgang Goethe-Universität Frankfurt, 60438 Frankfurt, Germany
| | - Harald Schwalbe
- Institute for Organic Chemistry and Chemical Biology, Center for Biomolecular Magnetic Resonance, Johann Wolfgang Goethe-Universität Frankfurt, 60438 Frankfurt, Germany
| | - Christina Redfield
- Department of Biochemistry, University of Oxford, South Parks Road, Oxford OX1 3QU, United Kingdom
| | - Richard J Temkin
- Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139, United States; Department of Physics, Massachusetts Institute of Technology, Cambridge, MA 02139, United States
| | - Robert G Griffin
- Department of Chemistry and Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, United States.
| |
Collapse
|
7
|
Kelz JI, Kelly JE, Martin RW. 3D-printed dissolvable inserts for efficient and customizable fabrication of NMR transceiver coils. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2019; 305:89-92. [PMID: 31229757 PMCID: PMC6656594 DOI: 10.1016/j.jmr.2019.06.008] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/08/2018] [Revised: 06/01/2019] [Accepted: 06/14/2019] [Indexed: 06/09/2023]
Abstract
We describe a simplified method for improving the reproducibility of transceiver coil fabrication for nuclear magnetic resonance (NMR) through single-use templates made from 3D-printed polymer forms. The utility of dissolvable inserts for achieving performance enhanced resonators (DIAPERs) is tested herein by a comparison of RF homogeneity along the rotor axis for variable-pitch solenoids with different inter-turn spacing. Simulated B1 field profiles are compared to experimental homogeneity measurements, demonstrating the potential of this approach for making NMR coils quickly and reproducibly.
Collapse
Affiliation(s)
- Jessica I Kelz
- Department of Chemistry, University of California, Irvine 92697-2025, United States
| | - John E Kelly
- Department of Chemistry, University of California, Irvine 92697-2025, United States
| | - Rachel W Martin
- Department of Chemistry, University of California, Irvine 92697-2025, United States; Department of Molecular Biology and Biochemistry, University of California, Irvine 92697-3900, United States.
| |
Collapse
|
8
|
Davoodi H, Jouda M, Korvink JG, MacKinnon N, Badilita V. Broadband and multi-resonant sensors for NMR. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2019; 112-113:34-54. [PMID: 31481158 DOI: 10.1016/j.pnmrs.2019.05.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2019] [Revised: 05/08/2019] [Accepted: 05/08/2019] [Indexed: 06/10/2023]
Abstract
It has always been of considerable interest to study the nuclear magnetic resonance response of multiple nuclei simultaneously, whether these signals arise from internuclear couplings within the same molecule, or from uncoupled nuclei within sample mixtures. The literature contains numerous uncorrelated reports on techniques employed to achieve multi-nuclear NMR detection. This paper consolidates the subset of techniques in which single coil detectors are utilized, and highlights the strengths and weaknesses of each approach, at the same time pointing the way towards future developments in the field of multi-nuclear NMR. We compare the different multi-nuclear NMR techniques in terms of performance, and present a guide to NMR probe designers towards application-based optimum design. We also review the applicability of micro-coils in the context of multi-nuclear methods. Micro-coils benefit from compact geometries and exhibit lower impedance, which provide new opportunities and challenges for the NMR probe designer.
Collapse
Affiliation(s)
- Hossein Davoodi
- Institute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Baden-Württemberg, Germany
| | - Mazin Jouda
- Institute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Baden-Württemberg, Germany
| | - Jan G Korvink
- Institute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Baden-Württemberg, Germany.
| | - Neil MacKinnon
- Institute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Baden-Württemberg, Germany
| | - Vlad Badilita
- Institute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Baden-Württemberg, Germany.
| |
Collapse
|
9
|
Scott FJ, Alaniva N, Golota NC, Sesti EL, Saliba EP, Price LE, Albert BJ, Chen P, O'Connor RD, Barnes AB. A versatile custom cryostat for dynamic nuclear polarization supports multiple cryogenic magic angle spinning transmission line probes. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2018; 297:23-32. [PMID: 30342370 DOI: 10.1016/j.jmr.2018.10.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/06/2018] [Revised: 09/29/2018] [Accepted: 10/02/2018] [Indexed: 06/08/2023]
Abstract
Dynamic nuclear polarization (DNP) with cryogenic magic angle spinning (MAS) provides significant improvements in NMR sensitivity, yet presents unique technical challenges. Here we describe a custom cryostat and suite of NMR probes capable of manipulating nuclear spins with multi-resonant radiofrequency circuits, cryogenic spinning below 6 K, sample exchange, and microwave coupling for DNP. The corrugated waveguide and six transfer lines needed for DNP and cryogenic spinning functionality are coupled to the probe from the top of the magnet. Transfer lines are vacuum-jacketed and provide bearing and drive gas, variable temperature fluid, two exhaust pathways, and a sample ejection port. The cryostat thermally isolates the magnet bore, thereby protecting the magnet and increasing cryogen efficiency. This novel design supports cryogenic MAS-DNP performance over an array of probes without altering DNP functionality. We present three MAS probes (two supporting 3.2 mm rotors and one supporting 9.5 mm rotors) interfacing with the single cryostat. Mechanical details, transmission line radio frequency design, and performance of the cryostat and three probes are described.
Collapse
Affiliation(s)
- Faith J Scott
- Department of Chemistry, Washington University in St. Louis, St. Louis, MO 63130, USA
| | - Nicholas Alaniva
- Department of Chemistry, Washington University in St. Louis, St. Louis, MO 63130, USA
| | - Natalie C Golota
- Department of Chemistry, Washington University in St. Louis, St. Louis, MO 63130, USA
| | - Erika L Sesti
- Department of Chemistry, Washington University in St. Louis, St. Louis, MO 63130, USA
| | - Edward P Saliba
- Department of Chemistry, Washington University in St. Louis, St. Louis, MO 63130, USA
| | - Lauren E Price
- Department of Chemistry, Washington University in St. Louis, St. Louis, MO 63130, USA
| | - Brice J Albert
- Department of Chemistry, Washington University in St. Louis, St. Louis, MO 63130, USA
| | - Pinhui Chen
- Department of Chemistry, Washington University in St. Louis, St. Louis, MO 63130, USA; Department of Physics, Washington University in St. Louis, St. Louis, MO 63130, USA
| | - Robert D O'Connor
- Laboratory of Bioorganic Chemistry, National Institute of Diabetes and Digestive and Kidney Diseases, Bethesda, MD 20892, USA
| | - Alexander B Barnes
- Department of Chemistry, Washington University in St. Louis, St. Louis, MO 63130, USA.
| |
Collapse
|
10
|
Martin RW, Kelly JE, Kelz JI. Advances in instrumentation and methodology for solid-state NMR of biological assemblies. J Struct Biol 2018; 206:73-89. [PMID: 30205196 DOI: 10.1016/j.jsb.2018.09.003] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2018] [Revised: 07/08/2018] [Accepted: 09/06/2018] [Indexed: 01/11/2023]
Abstract
Many advances in instrumentation and methodology have furthered the use of solid-state NMR as a technique for determining the structures and studying the dynamics of molecules involved in complex biological assemblies. Solid-state NMR does not require large crystals, has no inherent size limit, and with appropriate isotopic labeling schemes, supports solving one component of a complex assembly at a time. It is complementary to cryo-EM, in that it provides local, atomic-level detail that can be modeled into larger-scale structures. This review focuses on the development of high-field MAS instrumentation and methodology; including probe design, benchmarking strategies, labeling schemes, and experiments that enable the use of quadrupolar nuclei in biomolecular NMR. Current challenges facing solid-state NMR of biological assemblies and new directions in this dynamic research area are also discussed.
Collapse
Affiliation(s)
- Rachel W Martin
- Department of Chemistry, University of California, Irvine 92697-2025, United States; Department of Molecular Biology and Biochemistry, University of California, Irvine 92697-3900, United States.
| | - John E Kelly
- Department of Chemistry, University of California, Irvine 92697-2025, United States
| | - Jessica I Kelz
- Department of Chemistry, University of California, Irvine 92697-2025, United States
| |
Collapse
|
11
|
Doty FD. Guide to Simulating Complex NMR Probe Circuits. CONCEPTS IN MAGNETIC RESONANCE. PART A, BRIDGING EDUCATION AND RESEARCH 2018; 47A:e21463. [PMID: 31178669 PMCID: PMC6555146 DOI: 10.1002/cmr.a.21463] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2018] [Accepted: 10/09/2018] [Indexed: 05/28/2023]
Abstract
AbstractS‐parameter‐based circuit simulators are well suited to obtaining accurate solutions of even the most complex rf probe circuits. The basic theory necessary for determining the relative S/N of the probe circuit, based on B1/P0.5, from the voltage, current, impedance, and S‐parameter data that come from circuit simulators, is presented. Examples of simulator applications to circuits of increasing complexity are presented. A key requirement for effective utilization of circuit simulators in probe circuit optimizations is constructing an approximate analytical solution of the circuit, or an inverse simulation program, to accompany the direct circuit simulation, that calculates all the needed circuit component values based on minimal input data, such as B0, desired nuclides, sample coil description, and hardware options and details such as characteristics of various leads. A method of developing the needed inverse simulation program is presented for a simplified single‐coil HXY probe circuit. The inverse program is validated by the direct simulation itself. The methods are then applied to a detailed circuit that includes all significant leads, stray capacitances, couplings, and losses for a NB 28.2‐T 1‐mm HXYZ MAS probe. Similar HXY circuit models were validated by NMR experiments with rotor sizes from 0.75 mm to 3.2 mm at fields from 11.7 T to 21 T. Detailed HXYZ circuit model results at 11.7 T, including pulse widths, component values, voltages, and port isolations, agreed with experimental results within a few per cent. The 1200‐MHz HXYZ simulation predicted a 1H π/2 pulse of 1.3 μs at 25 W.
Collapse
|
12
|
Sesti EL, Alaniva N, Rand PW, Choi EJ, Albert BJ, Saliba EP, Scott FJ, Barnes AB. Magic angle spinning NMR below 6 K with a computational fluid dynamics analysis of fluid flow and temperature gradients. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2018; 286:1-9. [PMID: 29161649 DOI: 10.1016/j.jmr.2017.11.002] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/08/2017] [Revised: 11/01/2017] [Accepted: 11/06/2017] [Indexed: 05/05/2023]
Abstract
We report magic angle spinning (MAS) up to 8.5 kHz with a sample temperature below 6 K using liquid helium as a variable temperature fluid. Cross polarization 13C NMR spectra exhibit exquisite sensitivity with a single transient. Remarkably, 1H saturation recovery experiments show a 1H T1 of 21 s with MAS below 6 K in the presence of trityl radicals in a glassy matrix. Leveraging the thermal spin polarization available at 4.2 K versus 298 K should result in 71 times higher signal intensity. Taking the 1H longitudinal relaxation into account, signal averaging times are therefore predicted to be expedited by a factor of >500. Computer assisted design (CAD) and finite element analysis were employed in both the design and diagnostic stages of this cryogenic MAS technology development. Computational fluid dynamics (CFD) models describing temperature gradients and fluid flow are presented. The CFD models bearing and drive gas maintained at 100 K, while a colder helium variable temperature fluid stream cools the center of a zirconia rotor. Results from the CFD were used to optimize the helium exhaust path and determine the sample temperature. This novel cryogenic experimental platform will be integrated with pulsed dynamic nuclear polarization and electron decoupling to interrogate biomolecular structure within intact human cells.
Collapse
Affiliation(s)
- Erika L Sesti
- Department of Chemistry, Washington University in St. Louis, One Brookings Drive, St. Louis, MO 63130, USA
| | - Nicholas Alaniva
- Department of Chemistry, Washington University in St. Louis, One Brookings Drive, St. Louis, MO 63130, USA
| | - Peter W Rand
- Department of Chemistry, Washington University in St. Louis, One Brookings Drive, St. Louis, MO 63130, USA
| | - Eric J Choi
- Department of Chemistry, Washington University in St. Louis, One Brookings Drive, St. Louis, MO 63130, USA
| | - Brice J Albert
- Department of Chemistry, Washington University in St. Louis, One Brookings Drive, St. Louis, MO 63130, USA
| | - Edward P Saliba
- Department of Chemistry, Washington University in St. Louis, One Brookings Drive, St. Louis, MO 63130, USA
| | - Faith J Scott
- Department of Chemistry, Washington University in St. Louis, One Brookings Drive, St. Louis, MO 63130, USA
| | - Alexander B Barnes
- Department of Chemistry, Washington University in St. Louis, One Brookings Drive, St. Louis, MO 63130, USA.
| |
Collapse
|