1
|
Vine W, Savytskyi M, Vaartjes A, Kringhøj A, Parker D, Slack-Smith J, Schenkel T, Mølmer K, McCallum JC, Johnson BC, Morello A, Pla JJ. In situ amplification of spin echoes within a kinetic inductance parametric amplifier. SCIENCE ADVANCES 2023; 9:eadg1593. [PMID: 36897947 PMCID: PMC10005168 DOI: 10.1126/sciadv.adg1593] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/06/2022] [Accepted: 02/08/2023] [Indexed: 06/18/2023]
Abstract
The use of superconducting microresonators together with quantum-limited Josephson parametric amplifiers has enhanced the sensitivity of pulsed electron spin resonance (ESR) measurements by more than four orders of magnitude. So far, the microwave resonators and amplifiers have been designed as separate components due to the incompatibility of Josephson junction-based devices with magnetic fields. This has produced complex spectrometers and raised technical barriers toward adoption of the technique. Here, we circumvent this issue by coupling an ensemble of spins directly to a weakly nonlinear and magnetic field-resilient superconducting microwave resonator. We perform pulsed ESR measurements with a 1-pL mode volume containing 6 × 107 spins and amplify the resulting signals within the device. When considering only those spins that contribute to the detected signals, we find a sensitivity of [Formula: see text] for a Hahn echo sequence at a temperature of 400 mK. In situ amplification is demonstrated at fields up to 254 mT, highlighting the technique's potential for application under conventional ESR operating conditions.
Collapse
Affiliation(s)
- Wyatt Vine
- School of Electrical Engineering and Telecommunications, UNSW Sydney, Sydney, NSW 2052, Australia
| | - Mykhailo Savytskyi
- School of Electrical Engineering and Telecommunications, UNSW Sydney, Sydney, NSW 2052, Australia
| | - Arjen Vaartjes
- School of Electrical Engineering and Telecommunications, UNSW Sydney, Sydney, NSW 2052, Australia
| | - Anders Kringhøj
- School of Electrical Engineering and Telecommunications, UNSW Sydney, Sydney, NSW 2052, Australia
| | - Daniel Parker
- School of Electrical Engineering and Telecommunications, UNSW Sydney, Sydney, NSW 2052, Australia
| | - James Slack-Smith
- School of Electrical Engineering and Telecommunications, UNSW Sydney, Sydney, NSW 2052, Australia
| | - Thomas Schenkel
- Accelerator Technology and Applied Physics Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA
| | - Klaus Mølmer
- Niels Bohr Institute, University of Copenhagen, Blegdamsvej 17, DK-2100 Copenhagen, Denmark
| | | | | | - Andrea Morello
- School of Electrical Engineering and Telecommunications, UNSW Sydney, Sydney, NSW 2052, Australia
| | - Jarryd J. Pla
- School of Electrical Engineering and Telecommunications, UNSW Sydney, Sydney, NSW 2052, Australia
| |
Collapse
|
2
|
Dayan N, Artzi Y, Jbara M, Cristea D, Blank A. Pulsed Electron-Nuclear Double Resonance in the Fourier Regime. Chemphyschem 2022; 24:e202200624. [PMID: 36464644 DOI: 10.1002/cphc.202200624] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Revised: 11/24/2022] [Accepted: 12/01/2022] [Indexed: 12/11/2022]
Abstract
Nuclear magnetic resonance (NMR) spectroscopy provides atomic-level molecular structural information. However, in molecules containing unpaired electron spins, NMR signals are difficult to measure directly. In such cases, data is obtained using the electron-nuclear double resonance (ENDOR) method, where nuclei are detected through their interaction with nearby unpaired electron spins. Unfortunately, electron spins spread the ENDOR signals, which challenges current acquisition techniques, often resulting in low spectral resolution that provides limited structural details. Here, we show that by using miniature microwave resonators to detect a small number of electron spins, integrated with miniature NMR coils, one can excite and detect a wide bandwidth of ENDOR data in a single pulse. This facilitates the measurement of ENDOR spectra with narrow lines spread over a large frequency range at much better spectral resolution than conventional approaches, which helps reveal details of the paramagnetic molecules' chemical structure that were not accessible before.
Collapse
Affiliation(s)
- Nir Dayan
- Schulich Faculty of Chemistry, Technion - Israel Institute of Technology, 3200003, Haifa, Israel
| | - Yaron Artzi
- Schulich Faculty of Chemistry, Technion - Israel Institute of Technology, 3200003, Haifa, Israel
| | - Moamen Jbara
- Schulich Faculty of Chemistry, Technion - Israel Institute of Technology, 3200003, Haifa, Israel
| | - David Cristea
- Schulich Faculty of Chemistry, Technion - Israel Institute of Technology, 3200003, Haifa, Israel
| | - Aharon Blank
- Schulich Faculty of Chemistry, Technion - Israel Institute of Technology, 3200003, Haifa, Israel
| |
Collapse
|
3
|
Abhyankar N, Agrawal A, Campbell J, Maly T, Shrestha P, Szalai V. Recent advances in microresonators and supporting instrumentation for electron paramagnetic resonance spectroscopy. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2022; 93:101101. [PMID: 36319314 PMCID: PMC9632321 DOI: 10.1063/5.0097853] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Accepted: 08/13/2022] [Indexed: 06/16/2023]
Abstract
Electron paramagnetic resonance (EPR) spectroscopy characterizes the magnetic properties of paramagnetic materials at the atomic and molecular levels. Resonators are an enabling technology of EPR spectroscopy. Microresonators, which are miniaturized versions of resonators, have advanced inductive-detection EPR spectroscopy of mass-limited samples. Here, we provide our perspective of the benefits and challenges associated with microresonator use for EPR spectroscopy. To begin, we classify the application space for microresonators and present the conceptual foundation for analysis of resonator sensitivity. We summarize previous work and provide insight into the design and fabrication of microresonators as well as detail the requirements and challenges that arise in incorporating microresonators into EPR spectrometer systems. Finally, we provide our perspective on current challenges and prospective fruitful directions.
Collapse
Affiliation(s)
| | - Amit Agrawal
- Physical Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, USA
| | - Jason Campbell
- Physical Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, USA
| | - Thorsten Maly
- Bridge12 Technologies, Inc., Natick, Massachusetts 01760, USA
| | | | - Veronika Szalai
- Physical Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, USA
| |
Collapse
|