1
|
Olson MA, Han R, Ravula T, Borcik CG, Wang S, Viera PA, Rienstra CM. A complete 3D-printed tool kit for Solid-State NMR sample and rotor handling. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2024; 366:107748. [PMID: 39178738 PMCID: PMC11423700 DOI: 10.1016/j.jmr.2024.107748] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2024] [Revised: 07/31/2024] [Accepted: 08/05/2024] [Indexed: 08/26/2024]
Abstract
Solid state NMR (SSNMR) is a highly versatile and broadly applicable method for studying the structure and dynamics of biomolecules and materials. For scientists entering the field of SSNMR, the many quotidian activities required in the workflow to prepare samples for data collection can present a significant barrier to adoption. These steps include transfer of samples into rotors, marking the reflective surfaces for high sensitivity tachometer signal detection, inserting rotors into the magic-angle spinning (MAS) stator, achieving stable spinning, and removing and storing rotors to ensure reproducibility of data collection conditions. Even experienced spectroscopists experience occasional problems with these operations, and the cumulative probability of a delay to successful data collection is high enough to cause frequent disruptions to instrument schedules, particularly in the context of large facilities serving a diverse community of users. These problems are all amplified when utilizing rotors smaller than about 4 mm in diameter. Therefore, to improve the reliability and robustness of SSNMR sample preparation workflows, here we describe a set of tools for rotor packing, unpacking, tachometer marking, extraction and storage. Stereolithography 3D printing was employed as a cost-effective and convenient method for prototyping and manufacturing a full range of designs suitable for several types of probes and rotor geometries.
Collapse
Affiliation(s)
- Martin A Olson
- Department of Biochemistry, University of Wisconsin-Madison, Madison, WI, 53706 USA
| | - Ruixian Han
- Department of Chemistry, University of Wisconsin-Madison, Madison, WI, 53706 USA
| | - Thirupathi Ravula
- Department of Biochemistry, University of Wisconsin-Madison, Madison, WI, 53706 USA; National Magnetic Resonance Facility at Madison (NMRFAM), University of Wisconsin-Madison, Madison, WI, 53706 USA
| | - Collin G Borcik
- Department of Biochemistry, University of Wisconsin-Madison, Madison, WI, 53706 USA
| | - Songlin Wang
- National Magnetic Resonance Facility at Madison (NMRFAM), University of Wisconsin-Madison, Madison, WI, 53706 USA
| | - Perla A Viera
- Department of Biochemistry, University of Wisconsin-Madison, Madison, WI, 53706 USA; Biophysics Graduate Program, University of Wisconsin-Madison, Madison, WI, 53706 USA
| | - Chad M Rienstra
- Department of Biochemistry, University of Wisconsin-Madison, Madison, WI, 53706 USA; Department of Chemistry, University of Wisconsin-Madison, Madison, WI, 53706 USA; National Magnetic Resonance Facility at Madison (NMRFAM), University of Wisconsin-Madison, Madison, WI, 53706 USA.
| |
Collapse
|
2
|
Uribe JL, Jimenez MD, Kelz JI, Liang J, Martin RW. Automated test apparatus for bench-testing the magnetic field homogeneity of NMR transceiver coils. JOURNAL OF MAGNETIC RESONANCE OPEN 2024; 18:100142. [PMID: 38444623 PMCID: PMC10914335 DOI: 10.1016/j.jmro.2023.100142] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/07/2024]
Abstract
We describe an automated hands-off bench testing method for measuring the magnetic field profile of transceiver coils for nuclear magnetic resonance (NMR). The scattering parameter (S-parameter) data is measured using a portable network analyzer, and the results are automatically exported to a computer for plotting and viewing. This assay dramatically reduces the time needed to measure the magnetic field (B1) homogeneity profile of a transceiver coil while also improving accuracy relative to manual operation. Here, we demonstrate the method on a saddle coil of a solution-state NMR probe in comparison to profiles obtained using NMR spectroscopy measurements. We also measure the axial and radial homogeneity of a variable-pitch solenoid.
Collapse
Affiliation(s)
- Jose L Uribe
- Department of Chemistry, University of California, Irvine 92697-2025
| | - Matthew D Jimenez
- Department of Chemistry, University of California, Irvine 92697-2025
| | - Jessica I Kelz
- Department of Chemistry, University of California, Irvine 92697-2025
| | - Jeanie Liang
- Department of Chemistry, University of California, Irvine 92697-2025
| | - Rachel W Martin
- Department of Chemistry, University of California, Irvine 92697-2025
- Department of Molecular Biology and Biochemistry, University of California, Irvine 92697-3900
| |
Collapse
|
3
|
Osborn Popp TM, Matchett BT, Green RG, Chhabra I, Mumudi S, Bernstein AD, Perodeau JR, Nieuwkoop AJ. 3D-Printable centrifugal devices for biomolecular solid state NMR rotors. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2023; 354:107524. [PMID: 37481918 PMCID: PMC10528322 DOI: 10.1016/j.jmr.2023.107524] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Revised: 07/13/2023] [Accepted: 07/13/2023] [Indexed: 07/25/2023]
Abstract
The advent of magic angle spinning (MAS) rates exceeding 100 kHz has facilitated the acquisition of 1H-detected solid-state NMR spectra of biomolecules with high resolution. However, challenges can arise when preparing rotors for these experiments, due to the physical properties of biomolecular solid samples and the small dimensions of the rotors. In this study, we have designed 3D-printable centrifugal devices that facilitate efficient and consistent packing of crystalline protein slurries or viscous phospholipids into 0.7 mm rotors. We demonstrate the efficacy of these packing devices using 1H-detected solid state NMR at 105 kHz. In addition to devices for 0.7 mm rotors, we have also developed devices for other frequently employed rotor sizes and styles. We have made all our designs openly accessible, and we encourage their usage and ongoing development as a shared effort within the solid state NMR community.
Collapse
Affiliation(s)
- Thomas M Osborn Popp
- Department of Chemistry and Chemical Biology, Rutgers, The State University of New, Jersey, Piscataway, NJ 08854, United States.
| | - Brandon T Matchett
- Department of Chemistry and Chemical Biology, Rutgers, The State University of New, Jersey, Piscataway, NJ 08854, United States
| | - Rashawn G Green
- Department of Chemistry and Chemical Biology, Rutgers, The State University of New, Jersey, Piscataway, NJ 08854, United States
| | - Insha Chhabra
- Department of Chemistry and Chemical Biology, Rutgers, The State University of New, Jersey, Piscataway, NJ 08854, United States
| | - Smriti Mumudi
- Department of Chemistry and Chemical Biology, Rutgers, The State University of New, Jersey, Piscataway, NJ 08854, United States
| | - Ashley D Bernstein
- Department of Chemistry and Chemical Biology, Rutgers, The State University of New, Jersey, Piscataway, NJ 08854, United States
| | - Jacqueline R Perodeau
- Department of Chemistry and Chemical Biology, Rutgers, The State University of New, Jersey, Piscataway, NJ 08854, United States
| | - Andrew J Nieuwkoop
- Department of Chemistry and Chemical Biology, Rutgers, The State University of New, Jersey, Piscataway, NJ 08854, United States.
| |
Collapse
|
4
|
Pereira D, Sardo M, Marín-Montesinos I, Mafra L. One-Shot Resin 3D-Printed Stators for Low-Cost Fabrication of Magic-Angle Spinning NMR Probeheads. Anal Chem 2023. [PMID: 37376721 DOI: 10.1021/acs.analchem.3c01323] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/29/2023]
Abstract
Additive manufacturing such as three-dimensional (3D)-printing has revolutionized the fast and low-cost fabrication of otherwise expensive NMR parts. High-resolution solid-state NMR spectroscopy demands rotating the sample at a specific angle (54.74°) inside a pneumatic turbine, which must be designed to achieve stable and high spinning speeds without mechanical friction. Moreover, instability of the sample rotation often leads to crashes, resulting in costly repairs. Producing these intricate parts requires traditional machining, which is time-consuming, costly, and relies on specialized labor. Herein, we show that 3D-printing can be used to fabricate the sample holder housing (stator) in one shot, while the radiofrequency (RF) solenoid was constructed using conventional materials available in electronics stores. The 3D-printed stator, equipped with a homemade RF coil, showed remarkable spinning stability, yielding high-quality NMR data. At a cost below 5 €, the 3D-printed stator represents a cost reduction of over 99% compared to repaired commercial stators, illustrating the potential of 3D-printing for mass-producing affordable magic-angle spinning stators.
Collapse
Affiliation(s)
- Daniel Pereira
- CICECO─Aveiro Institute of Materials, Department of Chemistry, University of Aveiro, 3810-193 Aveiro, Portugal
| | - Mariana Sardo
- CICECO─Aveiro Institute of Materials, Department of Chemistry, University of Aveiro, 3810-193 Aveiro, Portugal
| | - Ildefonso Marín-Montesinos
- CICECO─Aveiro Institute of Materials, Department of Chemistry, University of Aveiro, 3810-193 Aveiro, Portugal
| | - Luís Mafra
- CICECO─Aveiro Institute of Materials, Department of Chemistry, University of Aveiro, 3810-193 Aveiro, Portugal
| |
Collapse
|