1
|
Awal ZI, Zani MR, Albaruni MASI, Rahman T, Islam MS. A model for SARS-CoV-2 virus transmission on the upper deck of a passenger ship bound for a short trip. Heliyon 2024; 10:e29506. [PMID: 38698983 PMCID: PMC11064074 DOI: 10.1016/j.heliyon.2024.e29506] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2023] [Revised: 03/04/2024] [Accepted: 04/09/2024] [Indexed: 05/05/2024] Open
Abstract
Public transportation plays a critical role in meeting transportation demands, particularly in densely populated areas. The COVID-19 pandemic has highlighted the importance of public health measures, including the need to prevent the spread of the virus through public transport. The spreading of the virus on a passenger ship is studied using the Computational Fluid Dynamic (CFD) model and Monte Carlo simulation. A particular focus was the context of Bangladesh, a populous maritime nation in South Asia, where a significant proportion of the population utilizes passenger ships to meet transportation demands. In this regard, a turbulence model is used, which simulates the airflow pattern and determines the contamination zone. Parameters under investigation are voyage duration, number of passengers on board, social distance, the effect of surgical masks, and others. This study shows that the transmission rate of SARS-CoV-2 infection on public transport, such as passenger ships, is not necessarily directly proportional to voyage duration or the number of passengers onboard. This model has the potential to be applied in various other modes of transportation, including public buses and airplanes. Implementing this model may help to monitor and address potential health risks effectively in the public transport networks.
Collapse
Affiliation(s)
- Zobair Ibn Awal
- Department of Naval Architecture and Marine Engineering, Bangladesh University of Engineering and Technology (BUET), Dhaka, 1000, Bangladesh
| | - Md Rafsan Zani
- Department of Naval Architecture and Marine Engineering, Bangladesh University of Engineering and Technology (BUET), Dhaka, 1000, Bangladesh
| | - Md Abu Sina Ibne Albaruni
- Department of Mechanical Engineering, Bangladesh University of Engineering and Technology (BUET), Dhaka, 1000, Bangladesh
| | - Tawhidur Rahman
- Department of Naval Architecture and Marine Engineering, Bangladesh University of Engineering and Technology (BUET), Dhaka, 1000, Bangladesh
| | - Md Shariful Islam
- Department of Naval Architecture and Offshore Engineering, Bangabandhu Sheikh Mujibur Rahman Maritime University, Bangladesh (BSMRMU), Dhaka, 1216, Bangladesh
| |
Collapse
|
2
|
Chillón SA, Fernandez-Gamiz U, Zulueta E, Ugarte-Anero A, Blanco JM. Numerical performance of CO 2 accumulation and droplet dispersion from a cough inside a hospital lift under different ventilation strategies. Sci Rep 2024; 14:6843. [PMID: 38514758 PMCID: PMC10957917 DOI: 10.1038/s41598-024-57425-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Accepted: 03/18/2024] [Indexed: 03/23/2024] Open
Abstract
The impact of mechanical ventilation on airborne diseases is not completely known. The recent pandemic of COVID-19 clearly showed that additional investigations are necessary. The use of computational tools is an advantage that needs to be included in the study of designing safe places. The current study focused on a hospital lift where two subjects were included: a healthy passenger and an infected one. The elevator was modelled with a fan placed on the middle of the ceiling and racks for supplying air at the bottom of the lateral wall. Three ventilation strategies were evaluated: a without ventilation case, an upwards-blowing exhausting fan case and a downwards-blowing fan case. Five seconds after the elevator journey began, the infected person coughed. For the risk assessment, the CO2 concentration, droplet removal performance and dispersion were examined and compared among the three cases. The results revealed some discrepancies in the selection of an optimal ventilation strategy. Depending on the evaluated parameter, downward-ventilation fan or no ventilation strategy could be the most appropriate approach.
Collapse
Affiliation(s)
- Sergio A Chillón
- Energy Engineering Department, School of Engineering of Vitoria-Gasteiz, University of the Basque Country, UPV/EHU, Nieves Cano 12, 01006, Vitoria-Gasteiz, Araba, Spain
| | - Unai Fernandez-Gamiz
- Energy Engineering Department, School of Engineering of Vitoria-Gasteiz, University of the Basque Country, UPV/EHU, Nieves Cano 12, 01006, Vitoria-Gasteiz, Araba, Spain.
| | - Ekaitz Zulueta
- Automatic and Simulation Department, University of the Basque Country, UPV/EHU, Nieves Cano 12, 01006, Vitoria-Gasteiz, Araba, Spain
| | - Ainara Ugarte-Anero
- Energy Engineering Department, School of Engineering of Vitoria-Gasteiz, University of the Basque Country, UPV/EHU, Nieves Cano 12, 01006, Vitoria-Gasteiz, Araba, Spain
| | - Jesus Maria Blanco
- Energy Engineering Department, School of Engineering, University of the Basque Country (UPV/EHU), Plaza Ingeniero Torres Quevedo, Building 1, 48013, Bilbao, Spain
| |
Collapse
|
3
|
Kusuluri R, Mirikar D, Palanivel S, Arumuru V. Risk assessment of airborne virus transmission in an intensive care unit due to single and sequential coughing. RISK ANALYSIS : AN OFFICIAL PUBLICATION OF THE SOCIETY FOR RISK ANALYSIS 2024; 44:54-69. [PMID: 37038233 DOI: 10.1111/risa.14133] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Revised: 01/19/2023] [Accepted: 03/02/2023] [Indexed: 06/19/2023]
Abstract
The virus causing COVID-19 has constantly been mutating into new variants. Some of them are more transmissive and resistant to antibiotics. The current research article aims to examine the airborne transmission of the virus expelled by coughing action in a typical intensive care unit. Both single and sequential coughing actions have been considered to get closer to practical scenarios. The objective is to assess the effectiveness of air change per hour (ACH) on the risk of infection to a healthcare person and how the air change rate influences the dispersion of droplets. Such a study is seldom reported and has significant relevance. A total of four cases were analyzed, of which two were of sequential cough. When the ACH is changed from 6 to 12, the average particle residence time is reduced by ∼7 s. It is found that the risk of infection in the case of sequential cough will be relatively low compared to a single cough if the outlet of the indoor environment is placed above the patient's head. This arrangement also eliminates the requirement of higher ACH, which has significance from an energy conservation perspective.
Collapse
Affiliation(s)
- Rajendra Kusuluri
- Applied Fluids Group, School of Mechanical Sciences, Indian Institute of Technology Bhubaneswar, Bhubaneswar, India
| | - Dnyanesh Mirikar
- Applied Fluids Group, School of Mechanical Sciences, Indian Institute of Technology Bhubaneswar, Bhubaneswar, India
| | - Silambarasan Palanivel
- Applied Fluids Group, School of Mechanical Sciences, Indian Institute of Technology Bhubaneswar, Bhubaneswar, India
| | - Venugopal Arumuru
- Applied Fluids Group, School of Mechanical Sciences, Indian Institute of Technology Bhubaneswar, Bhubaneswar, India
| |
Collapse
|
4
|
Martínez-Espinosa E, Carvajal-Mariscal I. Virus-laden droplet nuclei in vortical structures associated with recirculation zones in indoor environments: A possible airborne transmission of SARS-CoV-2. ENVIRONMENTAL ADVANCES 2023; 12:100376. [PMID: 37193349 PMCID: PMC10163794 DOI: 10.1016/j.envadv.2023.100376] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Accepted: 05/03/2023] [Indexed: 05/18/2023]
Abstract
Droplet nuclei dispersion patterns in indoor environments are reviewed from a physics view to explore the possibility of airborne transmission of SARS-CoV-2. This review analyzes works on particle dispersion patterns and their concentration in vortical structures in different indoor environments. Numerical simulations and experiments reveal the formation of the buildings' recirculation zones and vortex flow regions by flow separation, airflow interaction around objects, internal dispersion of airflow, or thermal plume. These vortical structures showed high particle concentration because particles are trapped for long periods. Then a hypothesis is proposed to explain why some medical studies detect the presence of SARS-CoV-2 and others do not detect the virus. The hypothesis proposes that airborne transmission is possible if virus-laden droplet nuclei are trapped in vortical structures associated with recirculation zones. This hypothesis is reinforced by a numerical study in a restaurant that presented possible evidence of airborne transmission by a large recirculating air zone. Furthermore, a medical study in a hospital is discussed from a physical view for identifying the formation of recirculation zones and their relation with positive tests for viruses. The observations show air sampling site located in this vortical structure is positive for the SARS-CoV-2 RNA. Therefore, the formation of vortical structures associated with recirculation zones should be avoided to minimize the possibility of airborne transmission. This work tries to understand the complex phenomenon of airborne transmission as a way in the prevention of transmission of infectious diseases.
Collapse
Affiliation(s)
- E Martínez-Espinosa
- Industrial and Environmental Processes Department, Instituto de Ingeniería, UNAM, Ciudad Universitaria, Mexico City 04510, México
| | | |
Collapse
|
5
|
A review on indoor airborne transmission of COVID-19– modelling and mitigation approaches. JOURNAL OF BUILDING ENGINEERING 2023; 64:105599. [PMCID: PMC9699823 DOI: 10.1016/j.jobe.2022.105599] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Revised: 11/11/2022] [Accepted: 11/21/2022] [Indexed: 06/09/2023]
Abstract
In the past few years, significant efforts have been made to investigate the transmission of COVID-19. This paper provides a review of the COVID-19 airborne transmission modeling and mitigation strategies. The simulation models here are classified into airborne transmission infectious risk models and numerical approaches for spatiotemporal airborne transmissions. Mathematical descriptions and assumptions on which these models have been based are discussed. Input data used in previous simulation studies to assess the dispersion of COVID-19 are extracted and reported. Moreover, measurements performed to study the COVID-19 airborne transmission within indoor environments are introduced to support validations for anticipated future modeling studies. Transmission mitigation strategies recommended in recent studies have been classified to include modifying occupancy and ventilation operations, using filters and air purifiers, installing ultraviolet (UV) air disinfection systems, and personal protection compliance, such as wearing masks and social distancing. The application of mitigation strategies to various building types, such as educational, office, public, residential, and hospital, is reviewed. Recommendations for future works are also discussed based on the current apparent knowledge gaps covering both modeling and mitigation approaches. Our findings show that different transmission mitigation measures were recommended for various indoor environments; however, there is no conclusive work reporting their combined effects on the level of mitigation that may be achieved. Moreover, further studies should be conducted to understand better the balance between approaches to mitigating the viral transmissions in buildings and building energy consumption.
Collapse
|
6
|
Norvihoho LK, Yin J, Zhou ZF, Han J, Chen B, Fan LH, Lichtfouse E. Mechanisms controlling the transport and evaporation of human exhaled respiratory droplets containing the severe acute respiratory syndrome coronavirus: a review. ENVIRONMENTAL CHEMISTRY LETTERS 2023; 21:1701-1727. [PMID: 36846189 PMCID: PMC9944801 DOI: 10.1007/s10311-023-01579-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Accepted: 02/13/2023] [Indexed: 05/24/2023]
Abstract
Transmission of the coronavirus disease 2019 is still ongoing despite mass vaccination, lockdowns, and other drastic measures to control the pandemic. This is due partly to our lack of understanding on the multiphase flow mechanics that control droplet transport and viral transmission dynamics. Various models of droplet evaporation have been reported, yet there is still limited knowledge about the influence of physicochemical parameters on the transport of respiratory droplets carrying the severe acute respiratory syndrome coronavirus 2. Here we review the effects of initial droplet size, environmental conditions, virus mutation, and non-volatile components on droplet evaporation and dispersion, and on virus stability. We present experimental and computational methods to analyze droplet transport, and factors controlling transport and evaporation. Methods include thermal manikins, flow techniques, aerosol-generating techniques, nucleic acid-based assays, antibody-based assays, polymerase chain reaction, loop-mediated isothermal amplification, field-effect transistor-based assay, and discrete and gas-phase modeling. Controlling factors include environmental conditions, turbulence, ventilation, ambient temperature, relative humidity, droplet size distribution, non-volatile components, evaporation and mutation. Current results show that medium-sized droplets, e.g., 50 µm, are sensitive to relative humidity. Medium-sized droplets experience delayed evaporation at high relative humidity, and increase airborne lifetime and travel distance. By contrast, at low relative humidity, medium-sized droplets quickly shrink to droplet nuclei and follow the cough jet. Virus inactivation within a few hours generally occurs at temperatures above 40 °C, and the presence of viral particles in aerosols impedes droplet evaporation.
Collapse
Affiliation(s)
- Leslie Kojo Norvihoho
- State Key Laboratory of Multiphase Flow in Power Engineering, Xi’an Jiaotong University, Xi’an, 710049 Shaanxi People’s Republic of China
| | - Jing Yin
- State Key Laboratory of Multiphase Flow in Power Engineering, Xi’an Jiaotong University, Xi’an, 710049 Shaanxi People’s Republic of China
| | - Zhi-Fu Zhou
- State Key Laboratory of Multiphase Flow in Power Engineering, Xi’an Jiaotong University, Xi’an, 710049 Shaanxi People’s Republic of China
| | - Jie Han
- School of Human Settlements and Civil Engineering, Xi’an Jiaotong University, Xi’an, 710049 Shaanxi People’s Republic of China
| | - Bin Chen
- State Key Laboratory of Multiphase Flow in Power Engineering, Xi’an Jiaotong University, Xi’an, 710049 Shaanxi People’s Republic of China
| | - Li-Hong Fan
- The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an, 710061 Shaanxi People’s Republic of China
| | - Eric Lichtfouse
- State Key Laboratory of Multiphase Flow in Power Engineering, Xi’an Jiaotong University, Xi’an, 710049 Shaanxi People’s Republic of China
| |
Collapse
|
7
|
Kong X, Chang Y, Fan M, Li H. Analysis on the thermal performance of low-temperature radiant floor coupled with intermittent stratum ventilation (LTR-ISV) for space heating. ENERGY AND BUILDINGS 2023; 278:112623. [PMID: 36345312 PMCID: PMC9630304 DOI: 10.1016/j.enbuild.2022.112623] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Revised: 10/07/2022] [Accepted: 10/28/2022] [Indexed: 06/16/2023]
Abstract
With increasing energy use and outbreaks of respiratory infectious diseases (such as COVID-19) in buildings, there is a growing interest in creating healthy and energy-efficient indoor environments. A novel heating system named low-temperature radiant floor coupled with intermittent stratum ventilation (LTR-ISV) is proposed in this study. Thermal performance, indoor air quality, energy and exergy performance were investigated and compared with conventional radiant floor heating (CRFH) and conventional radiant floor heating with mixing ventilation (CRFH + MV). The results indicated that LTR-ISV had a more uniform operative temperature distribution and overall thermal sensation, and air mixing was enhanced without generating additional draft sensation. Compared with CRFH and CRFH + MV, the indoor CO2 concentration in LTR-ISV can be reduced by 1355 ppm and 400 ppm, respectively. Airborne transmission risk can also be reduced by 5.35 times. The coefficient of performance for CRFH, CRFH + MV, and LTR-ISV during working hours was 4.2, 2.5, and 3.4, respectively. The lower value of LTR-ISV was due to the high energy usage of the primary air handing unit. In the non-working hours, LTR-ISV was 0.6 and 1.3 higher compared to CRFH and CRFH + MV, respectively. The exergy efficiency of LTR-ISV, CRFH, and CRFH + MV was 81.77 %, 76.43 %, and 64.71 %, respectively. Therefore, the LTR-ISV system can meet the requirements of high indoor air quality and thermal comfort and provides a reference for the energy-saving use of low-grade energy in space heating.
Collapse
Affiliation(s)
- Xiangfei Kong
- School of Energy and Environmental Engineering, Hebei University of Technology, Tianjin 300401, China
| | - Yufan Chang
- School of Energy and Environmental Engineering, Hebei University of Technology, Tianjin 300401, China
- Department of Building Environment and Energy, College of Civil Engineering, Hunan University, Changsha 410082, China
| | - Man Fan
- School of Energy and Environmental Engineering, Hebei University of Technology, Tianjin 300401, China
| | - Han Li
- School of Energy and Environmental Engineering, Hebei University of Technology, Tianjin 300401, China
| |
Collapse
|
8
|
Prophylactic Architecture: Formulating the Concept of Pandemic-Resilient Homes. BUILDINGS 2022. [DOI: 10.3390/buildings12070927] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The lockdown instituted during the COVID-19 pandemic has drawn the world’s attention to the importance of homes as integrated structures for practicing all aspects of life. The home has been transformed from a mere place to live into a complete piece of infrastructure accommodating all activities of life, including study, work, shopping, exercise, entertainment, and even telehealth. Although quarantines were necessary to protect against viral infection, we have faced social and psychological challenges due to the failure of the current home design to accommodate the new lockdown lifestyle during the pandemic. Thus, this study aims to set a foundation for the development and design of resilient homes in a post-quarantine world by establishing a comprehensive framework for quarantine-resilient homes. The framework was established on the basis of the relevant literature and proposals from architects and experts. It brings a perspective to the future requirements of homes so as to provide architects, stakeholders, and policymakers with the appropriate knowledge to mitigate the impact of lockdowns on mental health and well-being in residential buildings by focusing on the physical and architectural environment.
Collapse
|