Uemura K, Miyamura S, Otake Y, Mae H, Takashima K, Hamada H, Ebina K, Murase T, Sato Y, Okada S. The effect of forearm rotation on the bone mineral density measurements of the distal radius. J Bone Miner Metab 2024; 42:37-46. [PMID: 38057601 DOI: 10.1007/s00774-023-01473-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/16/2023] [Accepted: 10/09/2023] [Indexed: 12/08/2023]
Abstract
INTRODUCTION Forearm dual-energy X-ray absorptiometry (DXA) is often performed in clinics where central DXA is unavailable. Accurate bone mineral density (BMD) measurement is crucial for clinical assessment. Forearm rotation can affect BMD measurements, but this effect remains uncertain. Thus, we aimed to conduct a simulation study using CT images to clarify the effect of forearm rotation on BMD measurements. MATERIALS AND METHODS Forearm CT images of 60 women were analyzed. BMD was measured at the total, ultra-distal (UD), mid-distal (MD), and distal 33% radius regions with the radius located at the neutral position using digitally reconstructed radiographs generated from CT images. Then, the rotation was altered from - 30° to 30° (supination set as positive) with a one-degree increment, and the percent BMD changes from the neutral position were quantified for all regions at each angle for each patient. RESULTS The maximum mean BMD changes were 5.8%, 7.0%, 6.2%, and 7.2% for the total, UD, MD, and distal 33% radius regions, respectively. The analysis of the absolute values of the percent BMD changes from the neutral position showed that BMD changes of all patients remained within 2% when the rotation was between - 5° and 7° for the total region, between - 3° and 2° for the UD region, between - 4° and 3° for the MD region, and between - 3° and 1° for the distal 33% radius region. CONCLUSION Subtle rotational changes affected the BMD measurement of each region. The results showed the importance of forearm positioning when measuring the distal radius BMD.
Collapse
Affiliation(s)
- Keisuke Uemura
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, Suita, Osaka, Japan.
| | - Satoshi Miyamura
- Department of Orthopaedics, Osaka University Graduate School of Medicine, Suita, Osaka, Japan
| | - Yoshito Otake
- Division of Information Science, Graduate School of Science and Technology, Nara Institute of Science and Technology, Ikoma, Nara, Japan
| | - Hirokazu Mae
- Department of Orthopaedics, Osaka University Graduate School of Medicine, Suita, Osaka, Japan
| | - Kazuma Takashima
- Department of Orthopaedics, Osaka University Graduate School of Medicine, Suita, Osaka, Japan
| | - Hidetoshi Hamada
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, Suita, Osaka, Japan
| | - Kosuke Ebina
- Department of Orthopaedics, Osaka University Graduate School of Medicine, Suita, Osaka, Japan
| | - Tsuyoshi Murase
- Department of Orthopaedics, Osaka University Graduate School of Medicine, Suita, Osaka, Japan
| | - Yoshinobu Sato
- Division of Information Science, Graduate School of Science and Technology, Nara Institute of Science and Technology, Ikoma, Nara, Japan
| | - Seiji Okada
- Department of Orthopaedics, Osaka University Graduate School of Medicine, Suita, Osaka, Japan
| |
Collapse
|
2
|
Holm-Glad T, Godang K, Bollerslev J, Røkkum M, Reigstad O. Assessing Periprosthetic Bone in Total Wrist Arthroplasty: The Validity of DXA. J Clin Densitom 2021; 24:433-441. [PMID: 33172804 DOI: 10.1016/j.jocd.2020.10.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/26/2020] [Revised: 10/12/2020] [Accepted: 10/13/2020] [Indexed: 01/01/2023]
Abstract
INTRODUCTION Dual-energy X-ray absorptiometry (DXA) can measure bone mineral density (BMD) around joint arthroplasties. DXA has never been used in total wrist arthroplasties (TWA). We investigated (1) whether BMD differs between 2 TWAs implanted in the same cadaver forearm, (2) the effect of forearm rotation and wrist extension on measured BMD around TWA in a cadaver, and (3) the precision of DXA in a cadaver and patients. METHODOLOGY One ROI around the distal and 1 and 3 ROIs (ROI1-3) around the proximal component were used. Ten DXA scans were performed on forearm and femur mode convertible to orthopedic knee mode without arthroplasty, with ReMotion, and with Motec TWA in one cadaver forearm. Ten scans with 5° increments from 90°-70° pronation and 0°-20° extension, were performed with Motec. Precision was calculated as coefficient of variation (CV%) and least significant change (LSC%) from cadaver scans and double examinations with femur mode converted to orthopedic knee mode in 40 patients (20 ReMotion, 20 Motec). RESULTS BMD was higher in all Motec than corresponding ReMotion ROIs (p < 0.05). BMD changed with 10° supination in the distal ROI and ROI1, and with 5° extension in the distal ROI (p < 0.05). In the cadaver the orthopedic knee mode was more precise than the forearm mode in 3 Motec ROIs (p < 0.05). In patients CV was 2.21%-3.08% in the distal ROI, 1.66%-2.01% in the proximal ROI, and 1.98%-2.87% with 3 ROIs. CONCLUSIONS DXA is feasible for BMD measurement around the proximal component using the orthopedic knee mode, but not the distal component of TWA.
Collapse
Affiliation(s)
- Trygve Holm-Glad
- Division of Orthopaedic Surgery, Oslo University Hospital, Oslo, Norway; Institute of Clinical Medicine, University of Oslo, Oslo, Norway.
| | - Kristin Godang
- Section of specialized endocrinology, Oslo University hospital, Oslo, Norway
| | - Jens Bollerslev
- Institute of Clinical Medicine, University of Oslo, Oslo, Norway; Section of specialized endocrinology, Oslo University hospital, Oslo, Norway
| | - Magne Røkkum
- Division of Orthopaedic Surgery, Oslo University Hospital, Oslo, Norway; Institute of Clinical Medicine, University of Oslo, Oslo, Norway
| | - Ole Reigstad
- Division of Orthopaedic Surgery, Oslo University Hospital, Oslo, Norway; Institute of Clinical Medicine, University of Oslo, Oslo, Norway
| |
Collapse
|
3
|
Sawicki P, Tałałaj M, Życińska K, Zgliczyński WS, Wierzba W. Current Applications and Selected Technical Details of Dual-Energy X-Ray Absorptiometry. Med Sci Monit 2021; 27:e930839. [PMID: 34131097 PMCID: PMC8216008 DOI: 10.12659/msm.930839] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
The application of dual-energy X-ray absorptiometry (DXA) examinations in the assessment of bone mineral density (BMD) in the lumbar spine, hip, and forearm is the basic diagnostic method for recognition of osteoporosis. The constant development of DXA technique is due to the aging of societies and the increasing importance of osteoporosis as a public health problem. In order to assess the degree of bone demineralization in patients with hyperparathyroidism, forearm DXA examination is recommended. The vertebral fracture assessment (VFA) of the thoracic and lumbar spine, performed by a highly-skilled technician, is an interesting alternative to the X-ray examination. The DXA total body examination can be useful in the evaluation of fat redistribution among patients after bariatric surgery, in patients infected with HIV and receiving antiretroviral therapy, and in patients with metabolic diseases and suspected to have sarcopenia. The assessment of visceral adipose tissue (VAT) and detection of abdominal aortic calcifications may be useful in the prediction of cardiovascular events. The positive effect of anti-resorptive therapy may affect some parameters of DXA hip structure analysis (HSA). Long-term anti-resorptive therapy, especially with the use of bisphosphonates, may result in changes in the DXA image, which may herald atypical femur fractures (AFF). Reduction of the periprosthetic BMD in the DXA measurements can be used to estimate the likelihood of loosening the prosthesis and periprosthetic fractures. The present review aims to present current applications and selected technical details of DXA.
Collapse
Affiliation(s)
- Piotr Sawicki
- Department of Rheumatology, Systemic Connective Tissue Diseases and Rare Diseases, Central Clinical Hospital MSWiA in Warsaw, Warsaw, Poland
| | - Marek Tałałaj
- Department of Geriatrics, Internal Medicine and Metabolic Bone Diseases, Centre of Postgraduate Medical Education, Warsaw, Poland
| | - Katarzyna Życińska
- Department of Rheumatology, Systemic Connective Tissue Diseases and Rare Diseases, Central Clinical Hospital MSWiA in Warsaw, Warsaw, Poland.,Department of Family Medicine, Medical University of Warsaw, Warsaw, Poland
| | | | - Waldemar Wierzba
- Central Clinical Hospital MSWiA in Warsaw, Warsaw, Poland.,UHE Satellite Campus in Warsaw, University of Humanities and Economics in Łódź, Warsaw, Poland
| |
Collapse
|
4
|
Feit A, Levin N, McNamara EA, Sinha P, Whittaker LG, Malabanan AO, Rosen HN. Effect of Positioning of the Region of Interest on Bone Density of the Hip. J Clin Densitom 2020; 23:426-431. [PMID: 31036446 DOI: 10.1016/j.jocd.2019.04.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/11/2019] [Revised: 03/29/2019] [Accepted: 04/02/2019] [Indexed: 11/30/2022]
Abstract
BACKGROUND Large changes in positioning of the global region of interest (ROI) influence the measurement of bone mineral density (BMD) in the hip and forearm regions. However, it is unknown whether minor shifts in the positioning of the bottom of the global hip ROI affect the measurement of total hip BMD. METHODS The hip BMDs of 40 clinical densitometry patients were analyzed at baseline with the bottom of the global hip ROI positioned as usual, 10 mm distal to the base of the lesser trochanter (position 0). Then the hip was reanalyzed by shifting the bottom of the global hip ROI 1 mm proximally 10 times (positions +1 through +10) and then by shifting the bottom of the global hip ROI 1 mm distally 10 times (positions -1 through -10). The significance of the differences between mean values at the various distances from baseline was assessed using a Wilcoxon signed-rank test. RESULTS The mean total hip area, bone mineral content and BMD decreased as the bottom of the global hip ROI was shifted proximally; the decrease was significant when shifted by even 1 mm (p < 0.001). The mean total hip area, bone mineral content and BMD increased as the bottom of the global hip ROI was shifted distally; the increase was significant when shifted by even 1 mm (p < 0.001). The change in BMD with each 1 mm shift was uniform across the range studied from positions +10 through -10, and was approx 0.54%/mm. When the least significant change was based on 40 pairs of measurements, where each pair was comprised of the baseline scan and the same scan at -1 position, the least significant change was 0.01 g/cm2. CONCLUSIONS The BMD of the total hip is sensitive to even minor changes in the positioning of the bottom of the global hip ROI. Although a 1 mm change in the bottom of the global hip ROI positioning would make little difference in the reported T-score, it could easily affect the determination of significance in changes in BMD over time.
Collapse
Affiliation(s)
- Avery Feit
- Division of Endocrinology and Metabolism, Department of Medicine, Beth Israel Deaconess Medical Center, Boston, MA, USA
| | - Natan Levin
- Division of Endocrinology and Metabolism, Department of Medicine, Beth Israel Deaconess Medical Center, Boston, MA, USA
| | - Elizabeth A McNamara
- Division of Endocrinology and Metabolism, Department of Medicine, Beth Israel Deaconess Medical Center, Boston, MA, USA
| | - Partha Sinha
- Division of Endocrinology and Metabolism, Department of Medicine, Beth Israel Deaconess Medical Center, Boston, MA, USA
| | - LaTarsha G Whittaker
- Division of Endocrinology and Metabolism, Department of Medicine, Beth Israel Deaconess Medical Center, Boston, MA, USA
| | - Alan O Malabanan
- Division of Endocrinology and Metabolism, Department of Medicine, Beth Israel Deaconess Medical Center, Boston, MA, USA
| | - Harold N Rosen
- Division of Endocrinology and Metabolism, Department of Medicine, Beth Israel Deaconess Medical Center, Boston, MA, USA.
| |
Collapse
|
5
|
Impact of reference point selection on DXA-based measurement of forearm bone mineral density. Arch Osteoporos 2019; 14:107. [PMID: 31707587 PMCID: PMC9721067 DOI: 10.1007/s11657-019-0658-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/27/2019] [Accepted: 10/09/2019] [Indexed: 02/03/2023]
Abstract
UNLABELLED Few studies have systematically evaluated the technical aspects of forearm bone mineral density (BMD) measurement. We found that BMD remained stable regardless of the reference point; however, the ROI identified was not always consistent. Our study highlights the importance of using the same reference point for serial measurements of forearm BMD. BACKGROUND Forearm fractures are clinically important outcomes from the perspective of morbidity, health care costs, and interruption of work. BMD of the forearm, as derived by dual-energy x-ray absorptiometry (DXA), is a better predictor of fracture at the forearm compared with BMD measured at other sites. However, very few studies have evaluated the technical aspects of selecting the ROI for forearm BMD measurement. This study aimed to compare the BMD values measured at the 1/3 radius site using three different reference points: the ulnar styloid process, the radial endplate, and the bifurcation of the ulna and radius. METHODOLOGY Healthy Chinese patients participating in the control group of an ongoing study at Zhejiang Provincial People's Hospital were recruited for this study. For each patient, a DXA scan (GE Lunar Prodigy) of the forearm was performed and BMD values were separately calculated using each of the three reference points to identify the ROI. Pearson correlation coefficients were calculated to examine the correlation between the BMD measures derived from each reference point. The F test and independent t test were applied for more robust analysis of the differences in the variances and means. RESULTS Sixty-eight healthy Chinese volunteers agreed to participate in this study. The root mean square standard deviation (RMS-SD) percentages of BMD values measured at the 1/3 radius site were 2.19%, 2.23%, and 2.20% when using the ulnar styloid process, radial endplate, and the bifurcation of the ulna and radius as the reference points, respectively. Pearson's correlation coefficients for all pairwise comparisons among these three groups were greater than 0.99. F tests and independent t tests showed p values ranging from 0.92 to 0.99. However, we observed that among 10% of patients, choosing an ROI at the ulnar styloid process led to an inability to accurately determine the BMD at the ultra-distal radius. CONCLUSIONS Given equal ability to determine BMD at the 1/3 radius accurately, the radial endplate or the bifurcation of the ulna and radius should be preferentially selected as the reference point for routine forearm BMD measurements in order to avoid situations in which the ultra-distal radius BMD cannot be determined.
Collapse
|
6
|
Hussain D, Han SM. Computer-aided osteoporosis detection from DXA imaging. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2019; 173:87-107. [PMID: 31046999 DOI: 10.1016/j.cmpb.2019.03.011] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2019] [Revised: 03/10/2019] [Accepted: 03/13/2019] [Indexed: 06/09/2023]
Abstract
BACKGROUND AND OBJECTIVE Osteoporosis is a skeletal disease caused by a high rate of bone tissue loss, and it is a major cause of bone fracture. In contemporary society, osteoporosis is more common than cancer and stroke and results in a higher rate of morbidity and mortality in the human population. Osteoporosis can conclusively be diagnosed with dual energy X-ray absorptiometry (DXA). In this study, we propose a computer-aided osteoporosis detection (CAOD) technique that automatically measures bone mineral density (BMD) and generates an osteoporosis report from a DXA scan. METHODS The CAOD model denoise and segments DXA images using a non-local mean filter, Machine learning pixel label random forest respectively, and locates regions of interest with higher accuracy. Pixel label random forest classifies a pixel either bone or soft tissue; then contours are extracted from binary image to locate regions of interest and calculate BMD from bone and soft tissues pixels. Mean standard deviation and correlation coefficients statistical analysis were used to evaluate the consistency and accuracy of BMD measurements. RESULTS During a consistency test of BMD measurements using three consecutive scans from Computerized Imaging Reference Systems' Bona Fide Phantom (CIRS-BFP) for the spine, the CAOD model showed an averaged standard deviation of 0.0029 while the standard deviation from manual measurements on the same data set by three different individuals was recorded as 0.1199. During another correlation study of BMD measurements evaluating real human scan images by the CAOD model versus manual measurement, the model scored a correlation coefficient of R2 = 0.9901 while the CIRS-BFP study scored a correlation coefficient of R2 = 0.9709. CONCLUSIONS The CAOD model increases the preciseness and accuracy of BMD measurements. This CAOD method will help clinicians, untrained DXA operators, and researchers (medical scientists, doctors, and bone researchers) use the DXA system with reliable accuracy and overcome workload challenges. It will also improve osteoporosis diagnosis from DXA systems and increase system performance and value.
Collapse
Affiliation(s)
- Dildar Hussain
- Department of Biomedical Engineering, College of Electronics and Information, Kyung Hee University 1732, Yongin 17104, Republic of Korea.
| | - Seung-Moo Han
- Department of Biomedical Engineering, College of Electronics and Information, Kyung Hee University 1732, Yongin 17104, Republic of Korea.
| |
Collapse
|