1
|
Guo DM, Weng YZ, Yu ZH, Li SH, Qu WR, Liu XN, Qi H, Ma C, Tang XF, Li RY, Han Q, Xu H, Lu WW, Qin YG. Semi-automatic proximal humeral trabecular bone density assessment tool: technique application and clinical validation. Osteoporos Int 2024; 35:1049-1059. [PMID: 38459138 DOI: 10.1007/s00198-024-07047-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Accepted: 02/27/2024] [Indexed: 03/10/2024]
Abstract
PURPOSE This study aimed to apply a newly developed semi-automatic phantom-less QCT (PL-QCT) to measure proximal humerus trabecular bone density based on chest CT and verify its accuracy and precision. METHODS Subcutaneous fat of the shoulder joint and trapezius muscle were used as calibration references for PL-QCT BMD measurement. A self-developed algorithm based on a convolution map was utilized in PL-QCT for semi-automatic BMD measurements. CT values of ROIs used in PL-QCT measurements were directly used for phantom-based quantitative computed tomography (PB-QCT) BMD assessment. The study included 376 proximal humerus for comparison between PB-QCT and PL-QCT. Two sports medicine doctors measured the proximal humerus with PB-QCT and PL-QCT without knowing each other's results. Among them, 100 proximal humerus were included in the inter-operative and intra-operative BMD measurements for evaluating the repeatability and reproducibility of PL-QCT and PB-QCT. RESULTS A total of 188 patients with 376 shoulders were involved in this study. The consistency analysis indicated that the average bias between proximal humerus BMDs measured by PB-QCT and PL-QCT was 1.0 mg/cc (agreement range - 9.4 to 11.4; P > 0.05, no significant difference). Regression analysis between PB-QCT and PL-QCT indicated a good correlation (R-square is 0.9723). Short-term repeatability and reproducibility of proximal humerus BMDs measured by PB-QCT (CV: 5.10% and 3.41%) were slightly better than those of PL-QCT (CV: 6.17% and 5.64%). CONCLUSIONS We evaluated the bone quality of the proximal humeral using chest CT through the semi-automatic PL-QCT system for the first time. Comparison between it and PB-QCT indicated that it could be a reliable shoulder BMD assessment tool with acceptable accuracy and precision. This study developed and verify a semi-automatic PL-QCT for assessment of proximal humeral bone density based on CT to assist in the assessment of proximal humeral osteoporosis and development of individualized treatment plans for shoulders.
Collapse
Affiliation(s)
- De-Ming Guo
- Orthopaedic Medical Center, The Second Norman Bethune Hospital of Jilin University, Changchun, People's Republic of China
- Jilin Provincial Key Laboratory of Orthopaedics, Changchun, People's Republic of China
- Joint International Research Laboratory of Ageing Active Strategy and Bionic Health in Northeast Asia of Ministry of Education, Jilin University, Changchun, 130041, Jilin Province, China
| | - Yuan-Zhi Weng
- Orthopaedic and Traumatology, The University of Hong Kong, Hong Kong, People's Republic of China
| | - Ze-Hao Yu
- Orthopaedic Medical Center, The Second Norman Bethune Hospital of Jilin University, Changchun, People's Republic of China
- Jilin Provincial Key Laboratory of Orthopaedics, Changchun, People's Republic of China
- Joint International Research Laboratory of Ageing Active Strategy and Bionic Health in Northeast Asia of Ministry of Education, Jilin University, Changchun, 130041, Jilin Province, China
| | - Shi-Huai Li
- Orthopaedic Medical Center, The Second Norman Bethune Hospital of Jilin University, Changchun, People's Republic of China
- Jilin Provincial Key Laboratory of Orthopaedics, Changchun, People's Republic of China
- Joint International Research Laboratory of Ageing Active Strategy and Bionic Health in Northeast Asia of Ministry of Education, Jilin University, Changchun, 130041, Jilin Province, China
| | - Wen-Rui Qu
- Jilin Provincial Key Laboratory of Orthopaedics, Changchun, People's Republic of China
- Joint International Research Laboratory of Ageing Active Strategy and Bionic Health in Northeast Asia of Ministry of Education, Jilin University, Changchun, 130041, Jilin Province, China
- Department of Hand Surgery, The Second Norman Bethune Hospital of Jilin University, Changchun, People's Republic of China
| | - Xiao-Ning Liu
- Orthopaedic Medical Center, The Second Norman Bethune Hospital of Jilin University, Changchun, People's Republic of China
- Jilin Provincial Key Laboratory of Orthopaedics, Changchun, People's Republic of China
| | - Huan Qi
- Bone's Technology Limited, Shenzhen, Hong Kong, People's Republic of China
| | - Chi Ma
- Orthopaedic and Traumatology, The University of Hong Kong, Hong Kong, People's Republic of China
| | - Xiong-Feng Tang
- Orthopaedic Medical Center, The Second Norman Bethune Hospital of Jilin University, Changchun, People's Republic of China
- Jilin Provincial Key Laboratory of Orthopaedics, Changchun, People's Republic of China
- Joint International Research Laboratory of Ageing Active Strategy and Bionic Health in Northeast Asia of Ministry of Education, Jilin University, Changchun, 130041, Jilin Province, China
| | - Rui-Yan Li
- Orthopaedic Medical Center, The Second Norman Bethune Hospital of Jilin University, Changchun, People's Republic of China
- Jilin Provincial Key Laboratory of Orthopaedics, Changchun, People's Republic of China
- Joint International Research Laboratory of Ageing Active Strategy and Bionic Health in Northeast Asia of Ministry of Education, Jilin University, Changchun, 130041, Jilin Province, China
| | - Qinghe Han
- Radiology Department, The Second Norman Bethune Hospital of Jilin University, Changchun, People's Republic of China
| | - Hao Xu
- Joint International Research Laboratory of Ageing Active Strategy and Bionic Health in Northeast Asia of Ministry of Education, Jilin University, Changchun, 130041, Jilin Province, China
- College of Computer Science and Technology, Jilin University, Changchun, People's Republic of China
| | - Weijia William Lu
- Orthopaedic and Traumatology, The University of Hong Kong, Hong Kong, People's Republic of China.
| | - Yan-Guo Qin
- Orthopaedic Medical Center, The Second Norman Bethune Hospital of Jilin University, Changchun, People's Republic of China.
- Jilin Provincial Key Laboratory of Orthopaedics, Changchun, People's Republic of China.
- Joint International Research Laboratory of Ageing Active Strategy and Bionic Health in Northeast Asia of Ministry of Education, Jilin University, Changchun, 130041, Jilin Province, China.
| |
Collapse
|