1
|
Ilie-Mihai RM, Stefan-van Staden RI, van Staden J(KOOSF. Review—Progress in Electroanalysis of p53, CEA, and CA19–9. JOURNAL OF THE ELECTROCHEMICAL SOCIETY 2022; 169:037518. [DOI: 10.1149/1945-7111/ac5cea] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2025]
Abstract
Screening tests for panels of biomarkers such as the panel comprising p53, CEA, and CA19–9 facilitated early diagnosis of cancers and improvement of the quality of life. In this review, diverse electrochemical sensors used for the assay of p53, CEA, and CA 19–9 in biological samples are shown. Different methods of analysis such as differential pulse voltammetry, electrochemical impendance spectroscopy, chronoamperometry, and stochastic method were used for the assay of one biomarker (differential pulse voltammetry, chronoamperometry) or for the assay of a panel of biomarkers comprising p53, CA19–9, and CEA using stochastic method. The lowest limits of determination were obtained using the stochastic method; they were of fg ml−1/fU ml−1 magnitude order.
Collapse
|
2
|
Negut CC, Stefanov C, Gugoasa LAD, van Staden J(KF. Rapidly renewable graphite paste electrode modified with 5,10,15,20-tetrakis(4-methoxyphenyl)-21H,23H-porphine cobalt(II) for electrochemical determination of nicotinic acid. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.114063] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
3
|
Stefan-van Staden RI, Mitrofan G, Ionescu-Tirgoviste C. Pattern Recognition of Diabetes Related Biomarkers. ELECTROANAL 2018. [DOI: 10.1002/elan.201800523] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Raluca-Ioana Stefan-van Staden
- Laboratory of Electrochemistry and PATLAB Bucharest; National Institute of Research for Electrochemistry and Condensed Matter, 202; Splaiul Independentei St. Bucharest 060021 Romania
- Faculty of Applied Chemistry and Materials Science; Politehnica University of Bucharest; 1-7 Polizu St., Bucharest 011061 Romania
| | - Grigorina Mitrofan
- Faculty of Applied Chemistry and Materials Science; Politehnica University of Bucharest; 1-7 Polizu St., Bucharest 011061 Romania
| | | |
Collapse
|