Li X, Chang P, Liu X, Kang Y, Zhao Z, Duan Y, Zhang W. Developing a PK-PD model for propofol in exhaled air and the BIS following fospropofol disodium in beagles. BMC Vet Res 2025; 21:124. [PMID: 40022117 PMCID: PMC11869703 DOI: 10.1186/s12917-025-04570-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2024] [Accepted: 02/05/2025] [Indexed: 03/03/2025] Open
Abstract
BACKGROUND Fospropofol, a water-soluble prodrug of propofol, is metabolized into propofol by alkaline phosphatase after administration. This study aimed to develop a pharmacokinetic-pharmacodynamic (PK-PD) model that correlates the propofol concentration in exhaled air (Ce-pro-f) with its anesthetic effects, as measured by the bispectral index (BIS) in beagles. METHODS Beagles receiving a single intravenous infusion of fospropofol at varying doses were divided into three groups (n = 6): the DBL-fospro group (15 mg/kg), the DBM-fospro group (30 mg/kg), and the DBH-fospro group (60 mg/kg). Propofol levels were monitored using VUV-TOF MS from pre-administration to recovery. Correlations between Ce-pro-f and blood concentration (Cblood-pro), as well as between Ce-pro-f and the BIS were investigated. PK, PD, and PK-PD models describing the relationship between Ce and BIS were also analyzed. RESULTS Propofol concentration in exhaled air can be quantified using VUV-TOF MS at a mass-to-charge ratio of 177.6. After fospropofol injection, the peak Ce-pro-f was delayed compared to Cblood-pro. The PK model of Ce-pro-f can be described using a noncompartmental approach, corresponding to the linear PK characteristics. Additionally, Ce-pro-f showed a moderate to strong negative correlation with BIS values. In the PK-PD model, the PK component was well characterized by a two-compartment model incorporating a first-order delay to account for the time lag of Ce-pro-f relative to Cblood-pro. The PD component was well fitted by the inhibitory sigmoid Emax model, with an indirect connection model selected to explain the observed lag between BIS signals and Ce-pro-f peaks. CONCLUSIONS This study is the first to develop a PK-PD model for exhaled propofol in beagles after fospropofol disodium administration. The PK profile was described by a two-compartment model with a first-order delay, and the PD profile was modeled using an inhibitory sigmoid Emax model with an indirect connection model to capture the lag between BIS and exhaled propofol peaks.
Collapse
Affiliation(s)
- Xiaoxiao Li
- Department of Anesthesiology, West China Hospital, Sichuan University, Chengdu, Sichuan, China
- Laboratory of Anesthesia and Critical Care Medicine, West China Hospital, National-Local Joint Engineering Research Centre of Translational Medicine of Anesthesiology, Sichuan University, Chengdu, Sichuan, China
| | - Pan Chang
- Department of Anesthesiology, West China Hospital, Sichuan University, Chengdu, Sichuan, China
- Laboratory of Anesthesia and Critical Care Medicine, West China Hospital, National-Local Joint Engineering Research Centre of Translational Medicine of Anesthesiology, Sichuan University, Chengdu, Sichuan, China
| | - Xing Liu
- Department of Anesthesiology, West China Hospital, Sichuan University, Chengdu, Sichuan, China
- Laboratory of Anesthesia and Critical Care Medicine, West China Hospital, National-Local Joint Engineering Research Centre of Translational Medicine of Anesthesiology, Sichuan University, Chengdu, Sichuan, China
| | - Yi Kang
- Department of Anesthesiology, West China Hospital, Sichuan University, Chengdu, Sichuan, China
- Laboratory of Anesthesia and Critical Care Medicine, West China Hospital, National-Local Joint Engineering Research Centre of Translational Medicine of Anesthesiology, Sichuan University, Chengdu, Sichuan, China
| | - Zhongjun Zhao
- School of Mechanical Engineering, Sichuan University, Chengdu, Sichuan, China
| | - Yixiang Duan
- School of Mechanical Engineering, Sichuan University, Chengdu, Sichuan, China
| | - Wensheng Zhang
- Department of Anesthesiology, West China Hospital, Sichuan University, Chengdu, Sichuan, China.
- Laboratory of Anesthesia and Critical Care Medicine, West China Hospital, National-Local Joint Engineering Research Centre of Translational Medicine of Anesthesiology, Sichuan University, Chengdu, Sichuan, China.
| |
Collapse
|
2
|
Li X, Chang P, Zhang W. Online monitoring of propofol concentrations in exhaled breath. Heliyon 2024; 10:e39704. [PMID: 39759290 PMCID: PMC11699084 DOI: 10.1016/j.heliyon.2024.e39704] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2023] [Revised: 06/19/2024] [Accepted: 10/21/2024] [Indexed: 01/07/2025] Open
Abstract
Propofol, a widely used intravenous anesthetic agent, requires accurate monitoring to ensure therapeutic efficacy and prevent oversedation. Recent developments in modern analytical instrumentation have led to significant breakthroughs in on-line analysis of exhaled breath. This review discusses several sophisticated analytical methods that have been explored for noninvasive, real-time monitoring of propofol concentrations, including proton transfer reaction mass spectrometry, selected ion flow tube mass spectrometry, ion mobility spectrometry, and gas chromatography coupled to surface acoustic wave sensors. These techniques have demonstrated good correlations between plasma and exhaled propofol concentrations and between exhaled propofol concentrations and its cerebral effects. Despite these advances, the use of these technologies in clinical settings is hampered by challenges such as equipment noise, bulkiness, and high cost, as well as limitations related to endotracheal intubation, strong adsorption of propofol to components of the respiratory circuit, variability in respiratory patterns, susceptibility to changes in pulmonary ventilation and blood flow, inconsistencies in calibration methods, and the influence of other drugs and temperature fluctuations on measurement accuracy. Overcoming these technical and procedural challenges is critical to advancing the clinical application of breath analysis for propofol monitoring. This article reviews published studies and summarizes the progress and ongoing challenges in the field.
Collapse
Affiliation(s)
- Xiaoxiao Li
- Department of Anesthesiology, West China Hospital, Sichuan University, Chengdu, Sichuan, China
- Laboratory of Anesthesia and Critical Care Medicine, National-Local Joint Engineering Research Centre of Translational Medicine of Anesthesiology, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Pan Chang
- Department of Anesthesiology, West China Hospital, Sichuan University, Chengdu, Sichuan, China
- Laboratory of Anesthesia and Critical Care Medicine, National-Local Joint Engineering Research Centre of Translational Medicine of Anesthesiology, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Wensheng Zhang
- Department of Anesthesiology, West China Hospital, Sichuan University, Chengdu, Sichuan, China
- Laboratory of Anesthesia and Critical Care Medicine, National-Local Joint Engineering Research Centre of Translational Medicine of Anesthesiology, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| |
Collapse
|
3
|
Jia Z, Ong WQ, Zhang F, Du F, Thavasi V, Thirumalai V. A study of 9 common breath VOCs in 504 healthy subjects using PTR-TOF-MS. Metabolomics 2024; 20:79. [PMID: 39046579 DOI: 10.1007/s11306-024-02139-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/10/2024] [Accepted: 06/06/2024] [Indexed: 07/25/2024]
Abstract
INTRODUCTION This study employs Proton-Transfer-Reaction Mass Spectrometry (PTR-MS) to analyze exhaled breath profiles of 504 healthy adults, focusing on nine common volatile organic compounds (VOCs): acetone, acetaldehyde, acetonitrile, ethanol, isoprene, methanol, propanol, phenol, and toluene. PTR-MS offers real-time VOC measurement, crucial for understanding breath biomarkers and their applications in health assessment. OBJECTIVES The study aims to investigate how demographic factors-gender, age, and smoking history-affect VOC concentrations in exhaled breath. The objective is to enhance our understanding of breath biomarkers and their potential for health monitoring and clinical diagnosis. METHODS Exhaled breath samples were collected using PTR-MS, measuring concentrations of nine VOCs. The data were analyzed to discern distribution patterns across demographic groups. RESULTS Males showed higher average VOC levels for certain compounds. Propanol and methanol concentrations significantly increased with age. Smoking history influenced VOC levels, with differences among non-smokers, current smokers, and ex-smokers. CONCLUSION This research provides valuable insights into demographic influences on exhaled VOC profiles, emphasizing the potential of breath analysis for health assessment. PTR-MS's real-time measurement capabilities are crucial for capturing dynamic VOC changes, offering advantages over conventional methods. These findings lay a foundation for advancements in non-invasive disease detection, highlighting the importance of considering demographics in breath biomarker research.
Collapse
Affiliation(s)
- Zhunan Jia
- Breathonix Pte Ltd, Singapore, Singapore
- University of Oklahoma, Norman, OK, USA
| | | | | | - Fang Du
- Breathonix Pte Ltd, Singapore, Singapore
| | | | | |
Collapse
|
4
|
Li X, Chang P, Liu X, Kang Y, Zhao Z, Duan Y, Liu J, Zhang W. Exhaled breath is found to be better than blood samples for determining propofol concentrations in the brain tissues of rats. J Breath Res 2024; 18:026004. [PMID: 38211315 DOI: 10.1088/1752-7163/ad1d65] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Accepted: 01/11/2024] [Indexed: 01/13/2024]
Abstract
The correlation between propofol concentration in exhaled breath (CE) and plasma (CP) has been well-established, but its applicability for estimating the concentration in brain tissues (CB) remains unknown. Given the impracticality of directly sampling human brain tissues, rats are commonly used as a pharmacokinetic model due to their similar drug-metabolizing processes to humans. In this study, we measuredCE,CP, andCBin mechanically ventilated rats injected with propofol. Exhaled breath samples from the rats were collected every 20 s and analyzed using our team's developed vacuum ultraviolet time-of-flight mass spectrometry. Additionally, femoral artery blood samples and brain tissue samples at different time points were collected and measured using high-performance liquid chromatography mass spectrometry. The results demonstrated that propofol concentration in exhaled breath exhibited stronger correlations with that in brain tissues compared to plasma levels, suggesting its potential suitability for reflecting anesthetic action sites' concentrations and anesthesia titration. Our study provides valuable animal data supporting future clinical applications.
Collapse
Affiliation(s)
- Xiaoxiao Li
- Department of Anesthesiology, West China Hospital, Sichuan University, Chengdu, People's Republic of China
- Laboratory of Anesthesia and Critical Care Medicine, National-Local Joint Engineering Research Centre of Translational Medicine of Anesthesiology, West China Hospital, Sichuan University, Chengdu, People's Republic of China
| | - Pan Chang
- Department of Anesthesiology, West China Hospital, Sichuan University, Chengdu, People's Republic of China
- Laboratory of Anesthesia and Critical Care Medicine, National-Local Joint Engineering Research Centre of Translational Medicine of Anesthesiology, West China Hospital, Sichuan University, Chengdu, People's Republic of China
| | - Xing Liu
- Department of Anesthesiology, West China Hospital, Sichuan University, Chengdu, People's Republic of China
- Laboratory of Anesthesia and Critical Care Medicine, National-Local Joint Engineering Research Centre of Translational Medicine of Anesthesiology, West China Hospital, Sichuan University, Chengdu, People's Republic of China
| | - Yi Kang
- Department of Anesthesiology, West China Hospital, Sichuan University, Chengdu, People's Republic of China
- Laboratory of Anesthesia and Critical Care Medicine, National-Local Joint Engineering Research Centre of Translational Medicine of Anesthesiology, West China Hospital, Sichuan University, Chengdu, People's Republic of China
| | - Zhongjun Zhao
- School of Mechanical Engineering, Sichuan University, Chengdu, People's Republic of China
| | - Yixiang Duan
- School of Mechanical Engineering, Sichuan University, Chengdu, People's Republic of China
| | - Jin Liu
- Department of Anesthesiology, West China Hospital, Sichuan University, Chengdu, People's Republic of China
- Laboratory of Anesthesia and Critical Care Medicine, National-Local Joint Engineering Research Centre of Translational Medicine of Anesthesiology, West China Hospital, Sichuan University, Chengdu, People's Republic of China
| | - Wensheng Zhang
- Department of Anesthesiology, West China Hospital, Sichuan University, Chengdu, People's Republic of China
- Laboratory of Anesthesia and Critical Care Medicine, National-Local Joint Engineering Research Centre of Translational Medicine of Anesthesiology, West China Hospital, Sichuan University, Chengdu, People's Republic of China
| |
Collapse
|
5
|
Li X, Chang P, Liu X, Kang Y, Zhao Z, Duan Y, Zhu T, Liu J, Zhang W. A preclinical study on online monitoring of exhaled ciprofol concentration by the ultraviolet time-of-flight spectrometer and prediction of anesthesia depth in beagles. J Pharm Biomed Anal 2023; 235:115621. [PMID: 37572595 DOI: 10.1016/j.jpba.2023.115621] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2023] [Revised: 07/22/2023] [Accepted: 07/31/2023] [Indexed: 08/14/2023]
Abstract
BACKGROUND Exhaled air has been demonstrated as a reliable medium for monitoring propofol concentration. However, online monitoring of exhaled ciprofol have not been reported. METHODS Thirty-six beagles undergoing mechanical ventilation were divided into 6 groups, including bolus injection of low (Group BL, n = 6), medium (Group BM, n = 6), and high dose of ciprofol (Group BH, n = 6) groups; as well as 1 h continuous infusion of low (Group IL, n = 6), medium (Group IM, n = 6), and high dose of ciprofol (Group IH, n = 6) groups. The ciprofol concentration in exhaled air (CE) was determined by the ultraviolet time-of-flight mass spectrometer (UV-TOFMS). The correlations of CE and plasma concentration (Cp), CE and the bispectral index (BIS) were explored. Additionally, the pharmacokinetics (PK) models of CE and Cp, the pharmacodynamics (PD) models of CE and BIS were also established. RESULTS Online monitoring of exhaled ciprofol can be achieved with the UV-TOFMS instrument. The CE of ciprofol in beagles was found at parts per billion by volume (ppbv) level. The linear correlation of CE and Cp was weak in bolus injection groups (R2 = 0.01) nonetheless moderate in continuous infusion groups (R2 = 0.53). The i.v. bolus PK model of CE and Cp can be fitted with the non-compartment models. Additionally, the the PD models of CE and BIS can be well fitted with the inhibitory sigmoid Emax model with the estimate values of IC50 = 0.05 ± 0.01 ppbv, γ = 4.74 ± 1.51, E0 = 81.40 ± 3.75, Imax = 16.35 ± 4.27 in bolus injection groups; and IC50 = 0.05 ± 0.01 ppbv, γ = 6.92 ± 1.30, E0 = 83.08 ± 1.62, Imax = 12.58 ± 1.65 in continuous infusion groups. CONCLUSIONS Online monitoring of exhaled ciprofol concentration in beagles can be achieved with the UV-TOFMS instrument. Good correlations can be observed between exhaled ciprofol concentration and its cerebral effects reflected by the BIS value, demonstrating the potential of exhaled ciprofol monitoring for titrating depth of anesthesia in future clinical setting.
Collapse
Affiliation(s)
- Xiaoxiao Li
- Department of Anesthesiology, West China Hospital, Sichuan university, China; Laboratory of Anesthesia and Critical Care Medicine, National-Local Joint Engineering Research Centre of Translational Medicine of Anesthesiology, West China Hospital, Sichuan University, China
| | - Pan Chang
- Department of Anesthesiology, West China Hospital, Sichuan university, China; Laboratory of Anesthesia and Critical Care Medicine, National-Local Joint Engineering Research Centre of Translational Medicine of Anesthesiology, West China Hospital, Sichuan University, China
| | - Xing Liu
- Department of Anesthesiology, West China Hospital, Sichuan university, China; Laboratory of Anesthesia and Critical Care Medicine, National-Local Joint Engineering Research Centre of Translational Medicine of Anesthesiology, West China Hospital, Sichuan University, China
| | - Yi Kang
- Department of Anesthesiology, West China Hospital, Sichuan university, China; Laboratory of Anesthesia and Critical Care Medicine, National-Local Joint Engineering Research Centre of Translational Medicine of Anesthesiology, West China Hospital, Sichuan University, China
| | - Zhongjun Zhao
- School of Mechanical Engineering, Sichuan University, China
| | - Yixiang Duan
- School of Mechanical Engineering, Sichuan University, China
| | - Tao Zhu
- Department of Anesthesiology, West China Hospital, Sichuan university, China; Laboratory of Anesthesia and Critical Care Medicine, National-Local Joint Engineering Research Centre of Translational Medicine of Anesthesiology, West China Hospital, Sichuan University, China
| | - Jin Liu
- Department of Anesthesiology, West China Hospital, Sichuan university, China; Laboratory of Anesthesia and Critical Care Medicine, National-Local Joint Engineering Research Centre of Translational Medicine of Anesthesiology, West China Hospital, Sichuan University, China
| | - Wensheng Zhang
- Department of Anesthesiology, West China Hospital, Sichuan university, China; Laboratory of Anesthesia and Critical Care Medicine, National-Local Joint Engineering Research Centre of Translational Medicine of Anesthesiology, West China Hospital, Sichuan University, China.
| |
Collapse
|
6
|
Zhang J, Zhang Y, Xu C, Huang Z, Hu B. Detection of abused drugs in human exhaled breath using mass spectrometry: A review. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2023; 37 Suppl 1:e9503. [PMID: 36914281 DOI: 10.1002/rcm.9503] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/11/2022] [Revised: 02/07/2023] [Accepted: 03/08/2023] [Indexed: 06/18/2023]
Abstract
RATIONALE Human breath analysis has been attracting increasing interest in the detection of abused drugs in forensic and clinical applications because of its noninvasive sampling and distinctive molecular information. Mass spectrometry (MS)-based approaches have been proven to be powerful tools for accurately analyzing exhaled abused drugs. The major advantages of MS-based approaches include high sensitivity, high specificity, and versatile couplings with various breath sampling methods. METHODS Recent advances in the methodological development of MS analysis of exhaled abused drugs are discussed. Breath collection and sample pretreatment methods for MS analysis are also introduced. RESULTS Recent advances in technical aspects of breath sampling methods are summarized, highlighting active and passive sampling. MS methods for detecting different exhaled abused drugs are reviewed, emphasizing their features, advantages, and limitations. The future trends and challenges in MS-based breath analysis of exhaled abused drugs are also discussed. CONCLUSIONS The coupling of breath sampling methods with MS approaches has been proven to be a powerful tool for the detection of exhaled abused drugs, offering highly attractive results in forensic investigations. MS-based detection of exhaled abused drugs in exhaled breath is a relatively new field and is still in the early stages of methodological development. New MS technologies promise a substantial benefit for future forensic analysis.
Collapse
Affiliation(s)
- Jianfeng Zhang
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Jinan University, Guangzhou, China
| | - Ying Zhang
- Key Laboratory of Forensic Toxicology (Ministry of Public Security), Beijing Municipal Public Security Bureau, Beijing, China
| | - Chunhua Xu
- Guangzhou Hexin Instrument Co., Ltd, Guangzhou, China
| | - Zhengxu Huang
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Jinan University, Guangzhou, China
| | - Bin Hu
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Jinan University, Guangzhou, China
| |
Collapse
|
7
|
Awchi M, Sinues P, Datta AN, García-Gómez D, Singh KD. UHPLC-MS/MS-Based Identity Confirmation of Amino Acids Involved in Response to and Side Effects from Antiseizure Medications. J Proteome Res 2023; 22:990-995. [PMID: 36812155 PMCID: PMC9990125 DOI: 10.1021/acs.jproteome.2c00835] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Indexed: 02/24/2023]
Abstract
Real-time breath analysis using secondary electrospray ionization coupled with high-resolution mass spectrometry is a fast and noninvasive method to access the metabolic state of a person. However, it lacks the ability to unequivocally assign mass spectral features to compounds due to the absence of chromatographic separation. This can be overcomed by using exhaled breath condensate and conventional liquid chromatography-mass spectrometry (LC-MS) systems. In this study, to the best of our knowledge, we confirm for the first time the presence of six amino acids (GABA, Oxo-Pro, Asp, Gln, Glu, and Tyr) previously reported to be involved in response to and side effects from antiseizure medications in exhaled breath condensate and by extension in exhaled human breath. Raw data are publicly available at MetaboLights with the accession number MTBLS6760.
Collapse
Affiliation(s)
- Mo Awchi
- University
Children’s Hospital Basel, University
of Basel, Spitalstrasse 33, 4056 Basel, Switzerland
- Department
of Biomedical Engineering, University of
Basel, Gewerbestrasse
14, 4123 Allschwil, Switzerland
| | - Pablo Sinues
- University
Children’s Hospital Basel, University
of Basel, Spitalstrasse 33, 4056 Basel, Switzerland
- Department
of Biomedical Engineering, University of
Basel, Gewerbestrasse
14, 4123 Allschwil, Switzerland
| | - Alexandre N. Datta
- University
Children’s Hospital Basel, University
of Basel, Spitalstrasse 33, 4056 Basel, Switzerland
| | - Diego García-Gómez
- Department
of Analytical Chemistry, University of Salamanca, Plaza de los Caídos s/n, 37008 Salamanca, Spain
| | - Kapil Dev Singh
- University
Children’s Hospital Basel, University
of Basel, Spitalstrasse 33, 4056 Basel, Switzerland
- Department
of Biomedical Engineering, University of
Basel, Gewerbestrasse
14, 4123 Allschwil, Switzerland
| |
Collapse
|