Won J, Kang J, Kang W. Quantitative determination of ICG-001 in rat plasma using HPLC-MS/MS: A pharmacokinetic study.
J Pharm Biomed Anal 2022;
219:114949. [PMID:
35863168 DOI:
10.1016/j.jpba.2022.114949]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2022] [Revised: 07/13/2022] [Accepted: 07/15/2022] [Indexed: 12/01/2022]
Abstract
Although ICG-001, chemically synthesised from a bicyclic β-turn peptidomimetic template, represents various pharmacological activities, no validated determination methods in biological samples have been reported. This study was designed to establish a quantitative determination method for ICG-001 in rat plasma using high-performance liquid chromatography coupled with tandem mass spectrometry (HPLC-MS/MS) to validate the analytical method, including stability, and to characterise its pharmacokinetic behaviour in rats. After simple protein precipitation with acetonitrile, ICG-001 was eluted on a reversed-phase column using a mobile phase of water and acetonitrile (3:7 v/v, including 0.1% formic acid). The protonated precursor ion [M+H]+ and the major fragment ion were confirmed at m/z 549.2 and 141.4, respectively, for ICG-001. ICG-001 was stable under bench and storage conditions. The analytical method met the criteria for Food and Drug Administration-validated bioanalytical methods, and was successfully applied to a pharmacokinetic study for the first time following subcutaneous and intravenous administration.