1
|
Guo L, Lee HK, Oh S, Koirala GR, Kim TI. Smart Bioelectronics for Real-Time Diagnosis and Therapy of Body Organ Functions. ACS Sens 2025. [PMID: 40310273 DOI: 10.1021/acssensors.5c00024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/02/2025]
Abstract
Noncommunicable diseases (NCDs) associated with cardiovascular, neurological, and gastrointestinal disorders remain a leading cause of global mortality, sounding the alarm for the urgent need for better diagnostic and therapeutic solutions. Wearable and implantable biointegrated electronics offer a groundbreaking solution, combining real-time, high-resolution monitoring with innovative treatment capabilities tailored to specific organ functions. In this comprehensive review, we focus on the diseases affecting the brain, heart, gastrointestinal organs, bladder, and adrenal gland, along with their associated physiological parameters. Additionally, we provide an overview of the characteristics of these parameters and explore the potential of bioelectronic devices for in situ sensing and therapeutic applications and highlight the recent advancements in their deployment across specific organs. Finally, we analyze the current challenges and prospects of implementing closed-loop feedback control systems in integrated sensor-therapy applications. By emphasizing organ-specific applications and advocating for closed-loop systems, this review highlights the potential of future bioelectronics to address physiological needs and serves as a guide for researchers navigating the interdisciplinary fields of diagnostics, therapeutics, and personalized medicine.
Collapse
Affiliation(s)
- Lili Guo
- School of Chemical Engineering, Sungkyunkwan University (SKKU), 2066 Seobu-ro, Jangan-gu, Suwon 16419, Republic of Korea
| | - Hin Kiu Lee
- School of Chemical Engineering, Sungkyunkwan University (SKKU), 2066 Seobu-ro, Jangan-gu, Suwon 16419, Republic of Korea
| | - Suyoun Oh
- School of Chemical Engineering, Sungkyunkwan University (SKKU), 2066 Seobu-ro, Jangan-gu, Suwon 16419, Republic of Korea
| | - Gyan Raj Koirala
- School of Chemical Engineering, Sungkyunkwan University (SKKU), 2066 Seobu-ro, Jangan-gu, Suwon 16419, Republic of Korea
- Biomedical Institute for Convergence at SKKU (BICS), Sungkyunkwan University (SKKU), 2066 Seobu-ro, Jangan-gu, Suwon 16419, Republic of Korea
| | - Tae-Il Kim
- School of Chemical Engineering, Sungkyunkwan University (SKKU), 2066 Seobu-ro, Jangan-gu, Suwon 16419, Republic of Korea
- Biomedical Institute for Convergence at SKKU (BICS), Sungkyunkwan University (SKKU), 2066 Seobu-ro, Jangan-gu, Suwon 16419, Republic of Korea
| |
Collapse
|
2
|
Mella VSA, Cooper CE, Karr M, Krockenberger A, Madani G, Webb EB, Krockenberger MB. Hot climate, hot koalas: the role of weather, behaviour and disease on thermoregulation. CONSERVATION PHYSIOLOGY 2024; 12:coae032. [PMID: 38803425 PMCID: PMC11129715 DOI: 10.1093/conphys/coae032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2023] [Revised: 04/08/2024] [Accepted: 04/30/2024] [Indexed: 05/29/2024]
Abstract
Thermoregulation is critical for endotherms living in hot, dry conditions, and maintaining optimal core body temperature (Tb) in a changing climate is an increasingly challenging task for mammals. Koalas (Phascolarctos cinereus) have evolved physiological and behavioural strategies to maintain homeostasis and regulate their Tb but are thought to be vulnerable to prolonged heat. We investigated how weather, behaviour and disease influence Tb for wild, free-living koalas during summer in north-west New South Wales. We matched Tb with daily behavioural observations in an ageing population where chlamydial disease is prevalent. Each individual koala had similar Tb rhythms (average Tb = 36.4 ± 0.05°C), but male koalas had higher Tb amplitude and more pronounced daily rhythm than females. Disease disrupted the 24-hr circadian pattern of Tb. Koala Tb increased with ambient temperature (Ta). On the hottest day of the study (maximum Ta = 40.8°C), we recorded the highest (Tb = 40.8°C) but also the lowest (Tb = 32.4°C) Tb ever documented for wild koalas, suggesting that they are more heterothermic than previously recognized. This requires individuals to predict days of extreme Ta from overnight and early morning conditions, adjusting Tb regulation accordingly, and it has never been reported before for koalas. The large diel amplitude and low minimum Tb observed suggest that koalas at our study site are energetically and nutritionally compromised, likely due to their age. Behaviour (i.e. tree hugging and drinking water) was not effective in moderating Tb. These results indicate that Ta and koala Tb are strongly interconnected and reinforce the importance of climate projections for predicting the future persistence of koalas throughout their current distribution. Global climate models forecast that dry, hot weather will continue to escalate and drought events will increase in frequency, duration and severity. This is likely to push koalas and other arboreal folivores towards their thermal limit.
Collapse
Affiliation(s)
- Valentina S A Mella
- Sydney School of Veterinary Science, The University of Sydney, Sydney, New South Wales 2006, Australia
- School of Life and Environmental Sciences, The University of Sydney, Sydney, New South Wales 2006, Australia
| | - Christine E Cooper
- School of Molecular and Life Sciences, Curtin University, Perth, Western Australia 6102, Australia
| | - Madeline Karr
- School of Life and Environmental Sciences, The University of Sydney, Sydney, New South Wales 2006, Australia
| | - Andrew Krockenberger
- Division of Research and Innovation, James Cook University, Cairns, Queensland 4878, Australia
| | - George Madani
- School of Environmental and Life Sciences, The University of Newcastle, Callaghan, NSW 2308, Australia
| | - Elliot B Webb
- School of Life and Environmental Sciences, The University of Sydney, Sydney, New South Wales 2006, Australia
- Department of Planning and Environment, Science, Economics and Insights Division, Parramatta, New South Wales 2150, Australia
| | - Mark B Krockenberger
- Sydney School of Veterinary Science, The University of Sydney, Sydney, New South Wales 2006, Australia
| |
Collapse
|
3
|
Lu H, Aratake S, Naito H, Nogawa M, Nemoto T, Togawa T, Tanaka S. Development of a Core Body Thermometer Applicable for High-Temperature Environment Based on the Zero-Heat-Flux Method. SENSORS (BASEL, SWITZERLAND) 2023; 23:1970. [PMID: 36850568 PMCID: PMC9959565 DOI: 10.3390/s23041970] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/10/2023] [Revised: 02/04/2023] [Accepted: 02/07/2023] [Indexed: 06/18/2023]
Abstract
Monitoring core body temperature (CBT) allows observation of heat stress and thermal comfort in various environments. By introducing a Peltier element, we improved the zero-heat-flux core body thermometer for hot environments. In this study, we performed a theoretical analysis, designed a prototype probe, and evaluated its performance through simulator experiments with human subjects. The finite element analysis shows that our design can reduce the influence of external temperature variations by as much as 1%. In the simulator experiment, the prototype probe could measure deep temperatures within an error of less than 0.1 °C, regardless of outside temperature change. In the ergometer experiment with four subjects, the average difference between the prototype probe and a commercial zero-heat-flux probe was +0.1 °C, with a 95% LOA of -0.23 °C to +0.21 °C. In the dome sauna test, the results measured in six of the seven subjects exhibited the same trend as the reference temperature. These results show that the newly developed probe with the Peltier module can measure CBT accurately, even when the ambient temperature is higher than CBT up to 42 °C.
Collapse
Affiliation(s)
- Hanzi Lu
- Graduate School of Natural Science & Technology, Kanazawa University, Kanazawa 920-1164, Japan
| | - Shun Aratake
- Graduate School of Natural Science & Technology, Kanazawa University, Kanazawa 920-1164, Japan
| | - Hisashi Naito
- Institute of Science and Engineering, Kanazawa University, Kanazawa 920-1164, Japan
| | - Masamichi Nogawa
- Faculty of Health Sciences, Komatsu University, Komatsu 923-0961, Japan
| | - Tetsu Nemoto
- Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Kanazawa 920-0942, Japan
| | - Tatsuo Togawa
- Advanced Research Center for Human Sciences, Waseda University, Tokorozawa 359-1192, Japan
| | - Shinobu Tanaka
- Institute of Science and Engineering, Kanazawa University, Kanazawa 920-1164, Japan
| |
Collapse
|
4
|
A self-powered ingestible wireless biosensing system for real-time in situ monitoring of gastrointestinal tract metabolites. Nat Commun 2022; 13:7405. [PMID: 36456568 PMCID: PMC9715945 DOI: 10.1038/s41467-022-35074-y] [Citation(s) in RCA: 32] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2022] [Accepted: 11/17/2022] [Indexed: 12/03/2022] Open
Abstract
Information related to the diverse and dynamic metabolite composition of the small intestine is crucial for the diagnosis and treatment of various diseases. However, our current understanding of the physiochemical dynamics of metabolic processes within the small intestine is limited due to the lack of in situ access to the intestinal environment. Here, we report a demonstration of a battery-free ingestible biosensing system for monitoring metabolites in the small intestine. As a proof of concept, we monitor the intestinal glucose dynamics on a porcine model. Battery-free operation is achieved through a self-powered glucose biofuel cell/biosensor integrated into a circuit that performs energy harvesting, biosensing, and wireless telemetry via a power-to-frequency conversion scheme using magnetic human body communication. Such long-term biochemical analysis could potentially provide critical information regarding the complex and dynamic small intestine metabolic profiles.
Collapse
|
5
|
Teunissen LPJ, Jansen KMB, Janssen E, Kingma BRM, de Korte JQ, Eijsvogels TMH. Impact of different climatic conditions on peak core temperature of elite athletes during exercise in the heat: a Thermo Tokyo simulation study. BMJ Open Sport Exerc Med 2022; 8:e001313. [PMID: 35813127 PMCID: PMC9234798 DOI: 10.1136/bmjsem-2022-001313] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/15/2022] [Indexed: 11/04/2022] Open
Abstract
Objectives To evaluate how separate and combined climatic parameters affect peak core temperature during exercise in the heat using computer simulations fed with individual data. Methods The impact of eight environmental conditions on rectal temperature (Tre) was determined for exercise under heat stress using the Fiala-thermal-Physiology-and-Comfort simulation model. Variations in ambient temperature (Ta±6°C), relative humidity (RH±15%) and solar radiation (SR+921 W/m2) were assessed in isolation and combination (worst-case/best-case scenarios) and compared with baseline (Ta32°C, RH 75%, SR 0 W/m2). The simulation model was fed with personal, anthropometric and individual exercise characteristics. Results 54 athletes exercised for 46±10 min at baseline conditions and achieved a peak core temperature of 38.9±0.5°C. Simulations at a higher Ta (38°C) and SR (921 W/m2) resulted in a higher peak Tre compared with baseline (+0.6±0.3°C and +0.5±0.2°C, respectively), whereas a higher RH (90%) hardly affected peak Tre (+0.1±0.1°C). A lower Ta (26°C) and RH (60%) reduced peak Tre by −0.4±0.2°C and a minor −0.1±0.1°C, respectively. The worst-case simulation yielded a 1.5±0.4°C higher Tre than baseline and 2.0±0.7°C higher than the best-case condition. Conclusion Combined unfavourable climatic conditions produce a greater increase in peak core temperature than the sum of its parts in elite athletes exercising in the heat.
Collapse
Affiliation(s)
- Lennart P J Teunissen
- Department of Design Engineering, Delft University of Technology, Delft, The Netherlands
| | - Kaspar M B Jansen
- Department of Design Engineering, Delft University of Technology, Delft, The Netherlands
| | - Emiel Janssen
- Department of Design Engineering, Delft University of Technology, Delft, The Netherlands
| | - Boris R M Kingma
- Department of Training & Performance Innovations, TNO, Unit Defence, Safety & Security, Soesterberg, The Netherlands
| | - Johannus Q de Korte
- Radboud Institute for Health Sciences, Department of Physiology, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Thijs M H Eijsvogels
- Radboud Institute for Health Sciences, Department of Physiology, Radboud University Medical Center, Nijmegen, The Netherlands
| |
Collapse
|
6
|
de Korte JQ, Veenstra BJ, van Rijswick M, Derksen EJK, Hopman MTE, Bongers CCWG, Eijsvogels TMH. A Heart Rate Based Algorithm to Estimate Core Temperature Responses in Elite Athletes Exercising in the Heat. Front Sports Act Living 2022; 4:882254. [PMID: 35813051 PMCID: PMC9256956 DOI: 10.3389/fspor.2022.882254] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2022] [Accepted: 05/20/2022] [Indexed: 11/13/2022] Open
Abstract
Purpose Non-invasive non-obtrusive continuous and real-time monitoring of core temperature (Tc) may enhance pacing strategies, the efficacy of heat mitigation measures, and early identification of athletes at risk for heat-related disorders. The Estimated Core Temperature (ECTemp™) algorithm uses sequential heart rate (HR) values to predict Tc. We examined the validity of ECTemp™ among elite athletes exercising in the heat. Methods 101 elite athletes performed an exercise test in simulated hot and humid environmental conditions (ambient temperature: 31.6 ± 1.0°C, relative humidity: 74 ± 5%). Tc was continuously measured using a validated ingestible telemetric temperature capsule system. In addition, HR was continuously measured and used to compute the estimated core temperature (Tc-est) using the ECTemp™ algorithm. Results Athletes exercised for 44 ± 10 min and n = 5,025 readouts of Tc (range: 35.8-40.4°C), HR (range: 45-207 bpm), and Tc-est (range: 36.7-39.9°C) were collected. Tc-est demonstrated a small yet significant bias of 0.15 ± 0.29°C (p < 0.001) compared to Tc, with a limit of agreement of ±0.45°C and a root mean square error of 0.35 ± 0.18°C. Utilizing the ECTemp™ algorithm as a diagnostic test resulted in a fair to excellent sensitivity (73-96%) and specificity (72-93%) for Tc-est thresholds between 37.75 and 38.75°C, but a low to very-low sensitivity (50-0%) for Tc-est thresholds >39.0°C, due to a high prevalence of false-negative observations. Conclusion ECTemp™ provides a valuable and representative indication of thermal strain in the low- to mid-range of Tc values observed during exercise in the heat. It may, therefore, be a useful non-invasive and non-obtrusive tool to inform athletes and coaches about the estimated core temperature during controlled hyperthermia heat acclimation protocols. However, the ECTemp™ algorithm, in its current form, should not solely be used to identify athletes at risk for heat-related disorders due to low sensitivity and high false-negative rate in the upper end of the Tc spectrum.
Collapse
Affiliation(s)
- Johannus Q. de Korte
- Department of Physiology, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, Netherlands
| | - Bertil J. Veenstra
- Institute of Training Medicine & Training Physiology, TGTF, Royal Netherlands Army, Utrecht, Netherlands
| | - Mark van Rijswick
- Institute of Training Medicine & Training Physiology, TGTF, Royal Netherlands Army, Utrecht, Netherlands
| | - Eline J. K. Derksen
- Department of Physiology, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, Netherlands
| | - Maria T. E. Hopman
- Department of Physiology, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, Netherlands
| | - Coen C. W. G. Bongers
- Department of Physiology, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, Netherlands
| | - Thijs M. H. Eijsvogels
- Department of Physiology, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, Netherlands
| |
Collapse
|
7
|
Impact of thermal sensation on exercise performance in the heat: a Thermo Tokyo sub-study. Eur J Appl Physiol 2021; 122:437-446. [PMID: 34797439 DOI: 10.1007/s00421-021-04845-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Accepted: 11/10/2021] [Indexed: 10/19/2022]
Abstract
PURPOSE Thermal perception, including thermal sensation (TS), influences exercise performance in the heat. TS is a widely used measure and we examined the impact of initial TS (iTS) on performance loss during exercise in simulated Tokyo environmental conditions among elite athletes. METHODS 105 Elite outdoor athletes (endurance, skill, power and mixed trained) participated in this crossover study. Participants performed a standardized exercise test in control (15.8 ± 1.2 °C, 55 ± 6% relative humidity (RH)) and simulated Tokyo (31.6 ± 1.0 °C, 74 ± 5% RH) conditions to determine performance loss. TS was assessed ± 5 min prior to exercise (iTS) and every 5 min during the incremental exercise test (TS). Based on iTS in the Tokyo condition, participants were allocated to a neutral (iTS = 0, n = 11), slightly warm (iTS = 1, n = 50), or warm-to-hot (iTS = 2/3, n = 44) subgroup. RESULTS For the whole cohort iTS was 1 [1-2] and TS increased to 3 [3-3] at the end of exercise in the Tokyo condition. Average performance loss was 26.0 ± 10.7% in the Tokyo versus control condition. The slightly warm subgroup had less performance loss (22.3 ± 11.3%) compared to the warm-to-hot subgroup (29.4 ± 8.5%, p = 0.003), whereas the neutral subgroup did not respond different (28.8 ± 11.0%, p = 0.18) from the slightly warm subgroup. CONCLUSION iTS impacted the magnitude of performance loss among elite athletes exercising in hot and humid conditions. Athletes with a warm-to-hot iTS had more performance loss compared to counterparts with a slightly warm iTS, indicating that pre-cooling strategies and/or heat acclimation may be of additional importance for athletes in the warm-to-hot iTS group to mitigate the impact of heat stress.
Collapse
|
8
|
Awad A, Trenfield SJ, Pollard TD, Ong JJ, Elbadawi M, McCoubrey LE, Goyanes A, Gaisford S, Basit AW. Connected healthcare: Improving patient care using digital health technologies. Adv Drug Deliv Rev 2021; 178:113958. [PMID: 34478781 DOI: 10.1016/j.addr.2021.113958] [Citation(s) in RCA: 94] [Impact Index Per Article: 23.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2021] [Revised: 07/12/2021] [Accepted: 08/29/2021] [Indexed: 12/22/2022]
Abstract
Now more than ever, traditional healthcare models are being overhauled with digital technologies of Healthcare 4.0 increasingly adopted. Worldwide, digital devices are improving every stage of the patient care pathway. For one, sensors are being used to monitor patient metrics 24/7, permitting swift diagnosis and interventions. At the treatment stage, 3D printers are under investigation for the concept of personalised medicine by allowing patients access to on-demand, customisable therapeutics. Robots are also being explored for treatment, by empowering precision surgery, rehabilitation, or targeted drug delivery. Within medical logistics, drones are being leveraged to deliver critical treatments to remote areas, collect samples, and even provide emergency aid. To enable seamless integration within healthcare, the Internet of Things technology is being exploited to form closed-loop systems that remotely communicate with one another. This review outlines the most promising healthcare technologies and devices, their strengths, drawbacks, and opportunities for clinical adoption.
Collapse
Affiliation(s)
- Atheer Awad
- UCL School of Pharmacy, University College London, 29-39 Brunswick Square, London WC1N 1AX, UK
| | - Sarah J Trenfield
- UCL School of Pharmacy, University College London, 29-39 Brunswick Square, London WC1N 1AX, UK
| | - Thomas D Pollard
- UCL School of Pharmacy, University College London, 29-39 Brunswick Square, London WC1N 1AX, UK
| | - Jun Jie Ong
- UCL School of Pharmacy, University College London, 29-39 Brunswick Square, London WC1N 1AX, UK
| | - Moe Elbadawi
- UCL School of Pharmacy, University College London, 29-39 Brunswick Square, London WC1N 1AX, UK
| | - Laura E McCoubrey
- UCL School of Pharmacy, University College London, 29-39 Brunswick Square, London WC1N 1AX, UK
| | - Alvaro Goyanes
- UCL School of Pharmacy, University College London, 29-39 Brunswick Square, London WC1N 1AX, UK; FabRx Ltd., Henwood House, Henwood, Ashford, Kent TN24 8DH, UK; Departamento de Farmacología, Farmacia y Tecnología Farmacéutica, I+D Farma (GI-1645), Facultad de Farmacia, Health Research Institute of Santiago de Compostela (IDIS), Universidade de Santiago de Compostela, 15782, Spain
| | - Simon Gaisford
- UCL School of Pharmacy, University College London, 29-39 Brunswick Square, London WC1N 1AX, UK; FabRx Ltd., Henwood House, Henwood, Ashford, Kent TN24 8DH, UK
| | - Abdul W Basit
- UCL School of Pharmacy, University College London, 29-39 Brunswick Square, London WC1N 1AX, UK; FabRx Ltd., Henwood House, Henwood, Ashford, Kent TN24 8DH, UK.
| |
Collapse
|
9
|
de Korte JQ, Bongers CCWG, Hopman MTE, Teunissen LPJ, Jansen KMB, Kingma BRM, Ballak SB, Maase K, Moen MH, van Dijk JW, Daanen HAM, Eijsvogels TMH. Performance and thermoregulation of Dutch Olympic and Paralympic athletes exercising in the heat: Rationale and design of the Thermo Tokyo study: The journal Temperature toolbox. Temperature (Austin) 2021; 8:209-222. [PMID: 34485618 PMCID: PMC8409773 DOI: 10.1080/23328940.2021.1925618] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
The environmental conditions during the Tokyo Olympic and Paralympic Games are expected to be challenging, which increases the risk for participating athletes to develop heat-related illnesses and experience performance loss. To allow safe and optimal exercise performance of Dutch elite athletes, the Thermo Tokyo study aimed to determine thermoregulatory responses and performance loss among elite athletes during exercise in the heat, and to identify personal, sports-related, and environmental factors that contribute to the magnitude of these outcomes. For this purpose, Dutch Olympic and Paralympic athletes performed two personalized incremental exercise tests in simulated control (15°C, relative humidity (RH) 50%) and Tokyo (32°C, RH 75%) conditions, during which exercise performance and (thermo)physiological parameters were obtained. Thereafter, athletes were invited for an additional visit to conduct anthropometric, dual-energy X-ray absorptiometry (DXA), and 3D scan measurements. Collected data also served as input for a thermophysiological computer simulation model to estimate the impact of a wider range of environmental conditions on thermoregulatory responses. Findings of this study can be used to inform elite athletes and their coaches on how heat impacts their individual (thermo)physiological responses and, based on these data, advise which personalized countermeasures (i.e. heat acclimation, cooling interventions, rehydration plan) can be taken to allow safe and maximal performance in the challenging environmental conditions of the Tokyo 2020 Olympic and Paralympic Games.
Collapse
Affiliation(s)
- Johannus Q de Korte
- Department of Physiology, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
| | - Coen C W G Bongers
- Department of Physiology, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands.,Faculty of Health Sciences, Thermal Ergonomics Laboratory, The University of Sydney, Sydney, Australia
| | - Maria T E Hopman
- Department of Physiology, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
| | - Lennart P J Teunissen
- Department of Design Engineering, Delft University of Technology, Delft, The Netherlands
| | - Kaspar M B Jansen
- Department of Design Engineering, Delft University of Technology, Delft, The Netherlands
| | - Boris R M Kingma
- Department of Training and Performance Innovations, Unit Defence, Safety and Security, TNO, the Netherlands Organization for Applied Sciences, Soesterberg, The Netherlands.,Department of Nutrition, Exercise and Sports, Section for Integrative Physiology, University of Copenhagen, Copenhagen, Denmark
| | - Sam B Ballak
- Sport Science & Innovation Papendal, Sportcentrum Papendal, Arnhem, The Netherlands
| | - Kamiel Maase
- Netherlands Olympic Committee Netherlands Sports Federation, Arnhem, The Netherlands
| | - Maarten H Moen
- Netherlands Olympic Committee Netherlands Sports Federation, Arnhem, The Netherlands
| | - Jan-Willem van Dijk
- Institute of Sport and Exercise Studies, HAN University of Applied Sciences, Nijmegen, The Netherlands
| | - Hein A M Daanen
- Faculty of Behavioural and Movement Sciences, VU University Amsterdam, Amsterdam, The Netherlands.,Sizing Science, Soesterberg, The Netherlands
| | - Thijs M H Eijsvogels
- Department of Physiology, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
| |
Collapse
|
10
|
de Korte JQ, Bongers CCWG, Hopman MTE, Eijsvogels TMH. Exercise Performance and Thermoregulatory Responses of Elite Athletes Exercising in the Heat: Outcomes of the Thermo Tokyo Study. Sports Med 2021; 51:2423-2436. [PMID: 34396493 PMCID: PMC8514392 DOI: 10.1007/s40279-021-01530-w] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/29/2021] [Indexed: 11/30/2022]
Abstract
Objective We examined the impact of simulated Tokyo 2020 environmental condition on exercise performance, thermoregulatory responses and thermal perception among Dutch elite athletes. Methods 105 elite athletes from different sport disciplines performed two exercise tests in simulated control (15.9 ± 1.2 °C, relative humidity (RH) 55 ± 6%) and Tokyo (31.6 ± 1.0 °C, RH 74 ± 5%) environmental conditions. Exercise tests consisted of a 20-min warm-up (70% HRmax), followed by an incremental phase until volitional exhaustion (5% workload increase every 3 min). Gastrointestinal temperature (Tgi), heart rate, exercise performance and thermal perception were measured. Results Time to exhaustion was 16 ± 8 min shorter in the Tokyo versus the control condition (− 26 ± 11%, whereas peak power output decreased with 0.5 ± 0.3 W/kg (16 ± 7%). Greater exercise-induced increases in Tgi (1.8 ± 0.6 °C vs. 1.5 ± 0.5 °C, p < 0.001) and higher peak Tgi (38.9 ± 0.6 °C vs. 38.7 ± 0.4 °C, p < 0.001) were found in the Tokyo versus control condition. Large interindividual variations in exercise-induced increase in Tgi (range 0.7–3.5 °C) and peak Tgi (range 37.6–40.4 °C) were found in the Tokyo condition, with greater Tgi responses in endurance versus mixed- and skill-trained athletes. Peak thermal sensation and thermal comfort scores deteriorated in the Tokyo condition, with aggravated responses for power versus endurance- and mixed-trained athletes. Conclusion Large performance losses and Tgi increases were found among elite athletes exercising in simulated Tokyo conditions, with a substantial interindividual variation and significantly different responses across sport disciplines. These findings highlight the importance of an individual approach to optimally prepare athletes for safe and maximal exercise performance during the Tokyo Olympics. Supplementary Information The online version contains supplementary material available at 10.1007/s40279-021-01530-w.
Collapse
Affiliation(s)
- Johannus Q de Korte
- Department of Physiology (392), Radboud University Medical Centre, Radboud Institute for Health Sciences, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands
| | - Coen C W G Bongers
- Department of Physiology (392), Radboud University Medical Centre, Radboud Institute for Health Sciences, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands
| | - Maria T E Hopman
- Department of Physiology (392), Radboud University Medical Centre, Radboud Institute for Health Sciences, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands
| | - Thijs M H Eijsvogels
- Department of Physiology (392), Radboud University Medical Centre, Radboud Institute for Health Sciences, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands.
| |
Collapse
|
11
|
Périard JD, Eijsvogels TMH, Daanen HAM. Exercise under heat stress: thermoregulation, hydration, performance implications, and mitigation strategies. Physiol Rev 2021; 101:1873-1979. [PMID: 33829868 DOI: 10.1152/physrev.00038.2020] [Citation(s) in RCA: 195] [Impact Index Per Article: 48.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Abstract
A rise in body core temperature and loss of body water via sweating are natural consequences of prolonged exercise in the heat. This review provides a comprehensive and integrative overview of how the human body responds to exercise under heat stress and the countermeasures that can be adopted to enhance aerobic performance under such environmental conditions. The fundamental concepts and physiological processes associated with thermoregulation and fluid balance are initially described, followed by a summary of methods to determine thermal strain and hydration status. An outline is provided on how exercise-heat stress disrupts these homeostatic processes, leading to hyperthermia, hypohydration, sodium disturbances, and in some cases exertional heat illness. The impact of heat stress on human performance is also examined, including the underlying physiological mechanisms that mediate the impairment of exercise performance. Similarly, the influence of hydration status on performance in the heat and how systemic and peripheral hemodynamic adjustments contribute to fatigue development is elucidated. This review also discusses strategies to mitigate the effects of hyperthermia and hypohydration on exercise performance in the heat by examining the benefits of heat acclimation, cooling strategies, and hyperhydration. Finally, contemporary controversies are summarized and future research directions are provided.
Collapse
Affiliation(s)
- Julien D Périard
- University of Canberra Research Institute for Sport and Exercise, Bruce, Australia
| | - Thijs M H Eijsvogels
- Department of Physiology, Radboud Institute for Health Sciences, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Hein A M Daanen
- Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| |
Collapse
|
12
|
Affiliation(s)
- Jihong Min
- Andrew and Peggy Cherng Department of Medical EngineeringDivision of Engineering and Applied ScienceCalifornia Institute of Technology Pasadena CA 91125 USA
| | - Yiran Yang
- Andrew and Peggy Cherng Department of Medical EngineeringDivision of Engineering and Applied ScienceCalifornia Institute of Technology Pasadena CA 91125 USA
| | - Zhiguang Wu
- Andrew and Peggy Cherng Department of Medical EngineeringDivision of Engineering and Applied ScienceCalifornia Institute of Technology Pasadena CA 91125 USA
| | - Wei Gao
- Andrew and Peggy Cherng Department of Medical EngineeringDivision of Engineering and Applied ScienceCalifornia Institute of Technology Pasadena CA 91125 USA
| |
Collapse
|
13
|
van Delden M, Bongers CCWG, Broekens D, Daanen HAM, Eijsvogels TMH. Thermoregulatory burden of elite sailing athletes during exercise in the heat: A pilot study. Temperature (Austin) 2018; 6:66-76. [PMID: 30906812 PMCID: PMC6422492 DOI: 10.1080/23328940.2018.1540964] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2018] [Revised: 10/08/2018] [Accepted: 10/13/2018] [Indexed: 11/25/2022] Open
Abstract
Exercising in a hot and humid environment increases core body temperature, which may limit exercise performance. The risk of exercise-induced hyperthermia and associated performance decrement in Olympic sailing athletes is largely unknown. Therefore, this study aimed to compare thermoregulatory responses and performance indicators of elite sailors in a cool versus hot and humid environment. Seven elite athletes from four different Olympic sailing classes (Laser, RS:X, Finn, 470) performed cycling and/or rowing exercise in a cool (18°C) and hot (33°C) environment, while core body temperature (TC), skin temperature (TSK), exercise performance (covered distance), and rating of perceived exertion were measured continuously. TC increased significantly more in the hot environment (37.6 ± 0.2°C to 39.1 ± 0.1°C) compared to the cool environment (37.5 ± 0.1°C to 38.5 ± 0.2°C; p = 0.002), but the increase in TC between conditions differed substantially within individuals (range: 0.3°C – 0.9°C). Exercise performance decreased by 6.2 ± 2.9% in the hot environment (p = 0.013, range: 2.3%–9.5%), but more importantly, exercise performance was strongly inversely related to peak TC (R = −0.78, p = 0.039). Rating of perceived exertion (cool: 14.2 ± 0.6; hot: 13.9 ± 1.2) and increase in TSK (cool: 0.5 ± 1.0°C; hot: 0.9 ± 0.3°C) did not differ between conditions (p = 0.59 and p = 0.36, respectively). To conclude, a larger increase in TC and substantial exercise performance decrement were observed in the hot versus cool environment. As a further matter, large inter-individual differences were observed across athletes with an inverse relationship between TC and exercise performance, which stresses the importance of appropriate and personalized interventions to reduce thermoregulatory burden of elite sailors during exercise in the heat.
Collapse
Affiliation(s)
- Michelle van Delden
- Radboud Institute for Health Sciences, Department of Physiology, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Coen C W G Bongers
- Radboud Institute for Health Sciences, Department of Physiology, Radboud University Medical Center, Nijmegen, The Netherlands
| | | | - Hein A M Daanen
- Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Thijs M H Eijsvogels
- Radboud Institute for Health Sciences, Department of Physiology, Radboud University Medical Center, Nijmegen, The Netherlands.,Research Institute for Sport and Exercise Science, Liverpool John Moores University, Liverpool, UK
| |
Collapse
|
14
|
Bogerd CP, Velt KB, Annaheim S, Bongers CCWG, Eijsvogels TMH, Daanen HAM. Comparison of two telemetric intestinal temperature devices with rectal temperature during exercise. Physiol Meas 2018; 39:03NT01. [PMID: 29406308 DOI: 10.1088/1361-6579/aaad52] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE The discomfort caused by rectal probes and esophageal probes for the estimation of body core temperature has triggered the development of gastrointestinal (GI) capsules that are easily accepted by athletes and workers due to their non-invasive characteristics. We compare two new GI capsule devices with rectal temperature during cycle ergometer exercise and rest. APPROACH Eight participants followed a protocol of (i) 30 min exercise with a power output of 130 W, (ii) 5 min rest, (iii) 10 min self-paced maximum exercise, and (iv) 15 min rest. Core temperature was measured using two GI-capsule devices (e-Celsius and myTemp) and rectal temperature. MAIN RESULTS The myTemp system provided only slightly different temperatures to the rectal temperature probe during rest and exercise. However, the factory-calibrated e-Celsius system showed a systematic rectal temperature underestimation of 0.2 °C that is corrected in the 2018 versions. Both GI capsules reacted faster to temperature changes in the body compared to the rectal temperature probe during the rest period following maximum exercise. SIGNIFICANCE The GI-capsules react faster to temperature changes in the body compared to the rectal temperature probe, in particular during the rest period following exercise.
Collapse
Affiliation(s)
- C P Bogerd
- TNO, Training and Performance Innovations/CBRN Protection, Postbus 23, 3769 ZG Soesterberg, Netherlands
| | | | | | | | | | | |
Collapse
|