1
|
Axenhus M, Ödquist M, Abbaszadegan H, Sköldenberg O, Salomonsson B. Glenoid wear and migration pattern of a humeral head resurfacing implant: a prospective study using radio stereometric analysis. JSES Int 2024; 8:1241-1247. [PMID: 39822831 PMCID: PMC11733553 DOI: 10.1016/j.jseint.2024.07.012] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2025] Open
Abstract
Background The humeral head resurfacing arthroplasty (HHR) is normally used as a hemi shoulder arthroplasty and has been in use for the treatment of Gleno-Humeral osteoarthritis (OA) of the shoulder for more than 30 years. Some studies, however, shows that anatomical total shoulder arthroplasty provides better improvement in function than a HHR for patients with OA. Reasons for this may be a progressive glenoid wear (GW) or loosening of the HHR. We, therefore, wanted to investigate the migration pattern of the HHR and also GW by using radio stereometric analysis (RSA). Methods 21 patients (21 shoulders) with OA and a mean age of 64 years were enrolled in the study. They all received the Copeland humeral resurfacing head and were followed for 2 years with RSA. We evaluated the clinical outcome at 2 years with Western Ontario Osteoarthritis of the Shoulder (WOOS), EuroQol 5 dimension 3L and Constant Shoulder Score. In addition, we assessed data on WOOS and revisions until 5 years follow-up by using the local clinic data within the Swedish Shoulder Arthroplasty Register. Results After an initial migration at two months the implants were stable in relation to the humerus with no statistically significant difference between the 2 months and the 2 years value (P = .23). The GW continued to increase during the study period with an initial migration of mean 2.3 mm and at 2 years 3.5 mm with a statistically difference between the 6 months and 2 years value (P = .046). The WOOS, EuroQol 5 dimension 3L and Constant Shoulder Score were all improved at 2 years compared to the preoperative values. We found a weak correlation between GW at 2 years and the WOOS score at 2 and 5 years, but these did not reach statistical significance. There were 4 revisions within 5 years after the primary operation, all due to pain. Conclusion The marker-free RSA can be used in clinical studies for assessing migration in HHR implants and was also for the first time used to measure GW. The Copeland HHR seems to obtain a secure fixation in the humerus but shows continuous GW up to two years.
Collapse
Affiliation(s)
- Michael Axenhus
- Department of Clinical Sciences at Danderyd Hospital, Karolinska Institutet, Stockholm, Sweden
| | - Magnus Ödquist
- Department of Clinical Sciences at Danderyd Hospital, Karolinska Institutet, Stockholm, Sweden
| | - Hassan Abbaszadegan
- Department of Clinical Sciences at Danderyd Hospital, Karolinska Institutet, Stockholm, Sweden
| | - Olof Sköldenberg
- Department of Clinical Sciences at Danderyd Hospital, Karolinska Institutet, Stockholm, Sweden
| | - Björn Salomonsson
- Department of Clinical Sciences at Danderyd Hospital, Karolinska Institutet, Stockholm, Sweden
| |
Collapse
|
2
|
Tøttrup M, Thillemann JK, Thillemann TM, Mechlenburg I, Klebe T, Søballe K, Stilling M. Early offset-increasing migration predicts later revision for humeral head resurfacing implants. A randomized controlled radiostereometry trial with 10-year clinical follow-up. J Orthop Res 2022; 40:2688-2697. [PMID: 35220595 DOI: 10.1002/jor.25298] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2021] [Revised: 02/04/2022] [Accepted: 02/09/2022] [Indexed: 02/04/2023]
Abstract
In a randomized controlled setting, medium-term implant migration and long-term clinical outcomes were compared for the Copeland and the Global C.A.P. humeral head resurfacing implants (HHRI). Thirty-two patients (mean age 63 years) were randomly allocated to a Copeland (n = 14) or Global C.A.P. (n = 18) HHRI. Patients were followed for 5 years with radiostereometry, Constant Shoulder Score, and the Western Ontario Osteoarthritis of the Shoulder Index (WOOS). WOOS and revision status were also obtained cross-sectionally at a mean 10-year follow-up. At the 5-year follow-up, total translation (TT) was 0.75 mm (95% confidence interval [CI]: 0.53-0.97) for the Copeland HHRIs and 1.15 mm (95% CI: 0.85-1.46) for the Global C.A.P. HHRIs (p = 0.04), but the clinical scores were similar at all follow-ups. The cumulative risks of revision at 5 and 10 years were 29% and 43% for Copeland and 35% and 41% for Global C.A.P HHRIs (p > 0.7). No implants were loose at revision, but HHRIs that were later revised followed an early offset-increasing migration pattern with medial translation and lift-off resulting in a mean 0.53 mm (95% CI: 0.18-0.88) higher TT at the 1-year follow-up compared to non-revised HHRIs. In conclusion, the Global C.A.P. HHRI had higher TT compared with the Copeland HHRI, but clinical scores and revision rates were similar. Nonetheless, revision rates were high and challenge the use of HHRIs. Interestingly, an early radiostereometry evaluated HHRI migration pattern with increased off-set predicted later implant revision.
Collapse
Affiliation(s)
- Mikkel Tøttrup
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark.,Department of Orthopaedics, Aalborg University Hospital, Farsø, Denmark
| | - Janni Kjaergaard Thillemann
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark.,Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,Department of Orthopaedics, Hospital Unit West, University Clinic of Hand, Hip and Knee Surgery, Holstebro, Denmark
| | - Theis Muncholm Thillemann
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark
| | - Inger Mechlenburg
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,Department of Public Health, Aarhus University, Aarhus, Denmark
| | - Thomas Klebe
- Department of Orthopaedics, Silkeborg Regional Hospital, Silkeborg, Denmark
| | - Kjeld Søballe
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark
| | - Maiken Stilling
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark.,Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark
| |
Collapse
|
3
|
Andersen L, Krueger D, Bernatz J, Binkley N, Anderson PA, Grogan B. Humeral BMD can be Measured With DXA and Is Lower in the Surgical Arm After Total Shoulder Arthroplasty. J Clin Densitom 2022; 25:448-455. [PMID: 36114106 DOI: 10.1016/j.jocd.2022.08.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Accepted: 08/14/2022] [Indexed: 11/19/2022]
Abstract
BACKGROUND As arthroplasty leads to bone loss, we hypothesized that humeral bone mineral density (BMD) is lower after total shoulder arthroplasty (TSA) in the operative versus non-operative arm. However, there is no clinical approach to measure humeral BMD with dual-energy x-ray absorptiometry (DXA). The purposes of this pilot study were to develop DXA methodology to measure humerus BMD, propose humerus regions of interest (ROIs), compare TSA BMD to the non-operative arm, correlate humeral BMD with standard sites, and evaluate measurement reproducibility. METHODOLOGY Thirty-eight adults 1-5 years post-TSA had standard clinical DXA scans plus full humerus scans using the atypical femur fracture feature; precision was assessed in a subset (n = 32). Six custom ROIs were used to measure BMD throughout the humerus. Radius and humeral BMD were compared between arms by paired t-test and correlated ipsilaterally using Pearson's Correlation. Custom ROI BMD precision was assessed using the International Society for Clinical Densitometry (ISCD) advanced precision calculator. RESULTS Study included 38 subjects (24M/14F), with mean (SD) age and time post-surgery of 69.6 (7.7) years and 2.5 (1.3) years respectively. BMD was lower (p < 0.01) at all custom humerus sites (3.8% to 8.2%) on the surgical side but not different at radius sites. Humeral BMD correlated positively with ipsilateral ultra-distal and 1/3 radius (r = 0.54 to 0.86; p < 0.05). Custom BMD precision (%CV) ranged from 6.0-16.0%. CONCLUSIONS Humerus BMD can be measured using DXA and is lower in the TSA arm. Radius BMD correlated with humeral BMD but was not lower in the surgical arm. BMD precision was worse than usual clinical sites; use of software optimized for the femur is a notable limitation and likely contributes to suboptimal precision. Further study to assess the clinical utility of humeral BMD is needed. Automation and optimization of these measurements should improve precision.
Collapse
Affiliation(s)
- Lucas Andersen
- Osteoporosis Clinical Research Program, University of Wisconsin-Madison.
| | - Diane Krueger
- Osteoporosis Clinical Research Program, University of Wisconsin-Madison
| | - James Bernatz
- Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison
| | - Neil Binkley
- Osteoporosis Clinical Research Program, University of Wisconsin-Madison
| | - Paul A Anderson
- Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison
| | - Brian Grogan
- Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison
| |
Collapse
|
4
|
Jensen ML, Olsen BS, Nyring MRK, Yilmaz M, Petersen MM, Flivik G, Rasmussen JV. Implant migration and functional outcome of Reverse Shoulder Lateralized Glenosphere Line Extension System: a study protocol for a randomized controlled trial. Trials 2022; 23:579. [PMID: 35854390 PMCID: PMC9295266 DOI: 10.1186/s13063-022-06482-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Accepted: 06/18/2022] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND Inferior scapular notching is a complication unique to reverse shoulder arthroplasty. The most efficient technique to avoid inferior scapular notching has been reported to be lateralization of the glenoid offset. This study aims to compare radiological and functional outcomes of the DELTA Xtend® Reverse Shoulder System Lateralized Glenosphere Line Extension (intervention group) with the Standard DELTA Xtend® Reverse Shoulder System (control group). We hypothesize that the lateralization improves the patient outcome by decreasing the risk of inferior scapular notching without increasing the risk of migration and loosening of glenoid component. METHODS In this randomized controlled trial, all Danish citizens with rotator cuff arthropathy or degeneration of the glenohumeral joint with severe posterior wear and allocated for a reverse total shoulder arthroplasty at the department of orthopaedic surgery at Herlev and Gentofte Hospital, Copenhagen University Hospital, will be considered for participation. The exclusion criteria are as follows: below 50 years of age, cognitive or linguistic impairment, insufficient glenoid bone stock, previous fracture in the upper extremity and autoimmune-mediated inflammatory arthritis. There will be included a total of 122 patients of which 56 will participate in the radiostereometric analysis. This number of patients allows 20% to drop out. The co-primary outcomes are the pattern and magnitude of the migration of the glenoid component assessed by radiostereometric analysis and the Western Ontario Osteoarthritis of the Shoulder index. The secondary outcomes are inferior scapular notching, patient-reported and functional outcomes (Oxford shoulder score, Constant-Murley score and pain), side effects and complications, changes in bone mineral density and economy. The included patients will be examined before the surgery, within 1 week and 3, 6, 12 and 24 months after. DISCUSSION No previous studies have compared the conventional reverse shoulder arthroplasty with the lateralized reverse shoulder arthroplasty in a randomized controlled trial regarding migration and functional outcome. Furthermore, radiostereometric analysis has not been used to evaluate the migration of reverse shoulder arthroplasty in a randomized controlled trial. This study intends to determine which treatment has the most optimal outcome for the benefit of future patients with an indication for reverse shoulder arthroplasty. TRIAL REGISTRATION The study has been notified to Pactius and has approval number P-2021-231. Furthermore, the study will be registered on Clinicaltrials.gov before starting the inclusion.
Collapse
Affiliation(s)
- Marie Louise Jensen
- Department of Orthopedic Surgery, Herlev and Gentofte Hospital, Copenhagen University Hospital, Copenhagen, Denmark.
- Department of Orthopedic Surgery, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark.
| | - Bo S Olsen
- Department of Orthopedic Surgery, Herlev and Gentofte Hospital, Copenhagen University Hospital, Copenhagen, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Marc R K Nyring
- Department of Orthopedic Surgery, Herlev and Gentofte Hospital, Copenhagen University Hospital, Copenhagen, Denmark
- Department of Orthopedic Surgery, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
| | - Müjgan Yilmaz
- Department of Orthopedic Surgery, Herlev and Gentofte Hospital, Copenhagen University Hospital, Copenhagen, Denmark
- Department of Orthopedic Surgery, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
| | - Michael M Petersen
- Department of Orthopedic Surgery, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Gunnar Flivik
- Department of Orthopedic Surgery, Skaane University Hospital, Lund University, Lund, Sweden
| | - Jeppe V Rasmussen
- Department of Orthopedic Surgery, Herlev and Gentofte Hospital, Copenhagen University Hospital, Copenhagen, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
5
|
Jürgens-Lahnstein JH, Petersen ET, Laursen M, Hauskov Iversen C, Kaptein BL, Lindgren L, Stilling M. Development, construction, and validation of a thinner uniplanar calibration cage for radiostereometry. J Orthop Res 2022; 40:1645-1653. [PMID: 34664740 DOI: 10.1002/jor.25193] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Revised: 09/15/2021] [Accepted: 09/30/2021] [Indexed: 02/04/2023]
Abstract
Radiostereometric analysis (RSA) is an accurate and precise radiographic method that can be used to measure micromotion of implants and study joint kinematics in vivo. A calibration cage with radiopaque markers is used to calibrate the RSA images; however, the thickness (250 mm) of the calibration cage restricts the available area for the patient and equipment during RSA recordings. A thinner calibration cage would increase the recording area, facilitate handling of the cage, and ease integration of the cage with the RSA system. We developed a thinner calibration cage without compromise of accuracy and precision. First, we performed numerical simulations of an RSA system, and showed that the calibration cage thickness could be decreased to 140 mm maintaining accuracy and precision using 40 fiducial and 30 control markers. Second, we constructed a new calibration cage (NRT cage) according to the simulation results. Third, we validated the new calibration cage against two state-of-the-art calibration cages (Umeaa cage and Leiden cage) in a phantom study. All cages performed similar for marker-based analysis, except for y-rotation, where the Umeaa cage (SD = 0.064 mm) was less precise compared to the NRT (SD = 0.038 mm) and Leiden cages (0.042 mm) (p = .01). For model-based analysis the NRT cage had superior precision for translations (SD ≤ 0.054 mm) over the Leiden cage (SD ≤ 0.118 mm) and Umeaa cage (SD ≤ 0.093 mm) (p < .01). The combined study confirmed that the new and thinner calibration cage maintained accuracy and precision at the level of existing thicker calibration cages.
Collapse
Affiliation(s)
| | - Emil Toft Petersen
- Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark.,Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Mogens Laursen
- Department of Orthopaedics, Aalborg University Hospital, Aalborg, Denmark
| | | | - Bart L Kaptein
- Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands
| | - Lars Lindgren
- Department of Radiology, Aarhus University Hospital, Aarhus, Denmark
| | - Maiken Stilling
- Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark.,Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| |
Collapse
|
6
|
Ten Brinke B, Hesseling B, Eygendaal D, Hoelen MA, Mathijssen NMC. Early fixation of the humeral component in stemless total shoulder arthroplasty : a radiostereometric and clinical study with 24-month follow-up. Bone Joint J 2022; 104-B:76-82. [PMID: 34969283 DOI: 10.1302/0301-620x.104b1.bjj-2021-0945.r1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS Stemless humeral implants have been developed to overcome stem-related complications in total shoulder arthroplasty (TSA). However, stemless implant designs may hypothetically result in less stable initial fixation, potentially affecting long-term survival. The aim of this study is to investigate early fixation and migration patterns of the stemless humeral component of the Simpliciti Shoulder System and to evaluate clinical outcomes. METHODS In this prospective cohort study, radiostereometric analysis (RSA) radiographs were obtained in 24 patients at one day, six weeks, six months, one year, and two years postoperatively. Migration was calculated using model-based RSA. Clinical outcomes were evaluated using the visual analogue scale (VAS), the Oxford Shoulder Score (OSS), the Constant-Murley Score (CMS), and the Disabilities of the Arm, Shoulder and Hand (DASH) score. RESULTS At two years, median translation along the x-, y-, and z-axis was -0.12 mm (interquartile range (IQR) -0.18 to 0.02), -0.17 mm (IQR -0.27 to -0.09), and 0.09 mm (IQR 0.02 to 0.31). Median rotation around the x-, y-, and z-axis was 0.12° (IQR -0.50 to 0.57), -0.98° (IQR -1.83 to 1.23), and 0.09° (IQR -0.76 to 0.30). Overall, 20 prostheses stabilized within 12 months postoperatively. Four prostheses showed continuous migration between 12 and 24 months. At two-year follow-up, with the exception of one revised prosthesis, all clinical scores improved significantly (median VAS difference at rest: -3.0 (IQR -1.5 to -6.0); OSS 22.0 (IQR 15.0 to 25.0); CMS 29.5 (IQR 15.0 to 35.75); and DASH -30.0 (IQR -20.6 to -41.67) (all p < 0.001)) with the exception of one revised prosthesis. CONCLUSION In conclusion, we found that 20 out of 24 implants stabilized within 12 months postoperatively. The significance of continuous migration in four implants is unclear and future research on the predictive value of early migration for future loosening in TSA is required. Clinical results revealed a clinically relevant improvement. Cite this article: Bone Joint J 2022;104-B(1):76-82.
Collapse
Affiliation(s)
- Bart Ten Brinke
- Department of Orthopaedic Surgery, Reinier de Graaf Hospital, Delft, Netherlands
| | - Brechtje Hesseling
- Department of Orthopaedic Surgery, Reinier de Graaf Hospital, Delft, Netherlands
| | - Denise Eygendaal
- Department of Orthopaedic Surgery, Erasmus Medical Center, Delft, Netherlands
| | - Max A Hoelen
- Department of Orthopaedic Surgery, Reinier de Graaf Hospital, Delft, Netherlands
| | - Nina M C Mathijssen
- Department of Orthopaedic Surgery, Reinier de Graaf Hospital, Delft, Netherlands
| |
Collapse
|
7
|
Fraser AN, Bøe B, Fjalestad T, Madsen JE, Röhrl SM. Stable glenoid component of reverse total shoulder arthroplasty at 2 years as measured with model-based radiostereometric analysis (RSA). Acta Orthop 2021; 92:644-650. [PMID: 34196600 PMCID: PMC8635662 DOI: 10.1080/17453674.2021.1943932] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Reverse total shoulder arthroplasty (TSA) is used for treating cuff arthropathy, displaced proximal humeral fractures (PHF), and in revision shoulder surgery, despite sparse evidence on long-term results. We assessed stability of the glenoid component in reverse TSA, using model-based RSA.Patients and methods - 20 patients (mean age 76 years, 17 female), operated on with reverse TSA at Oslo University Hospital, in 2015-2017 were included. Indications for surgeries were PHFs, malunion, cuff arthropathy, and chronic shoulder dislocation. RSA markers were placed in the scapular neck, the coracoid, and the acromion. RSA radiographs were conducted postoperatively, at 3 months, 1 year, and 2 years. RSA analysis was performed using RSAcore with Reversed Engineering (RE) modality, with clinical precision < 0.25 mm for all translations (x, y, z) and < 0.7° for rotations (x, z). Scapular "notching" was assessed in conventional radiographs.Results - 1 patient was excluded due to revision surgery. More than half of the patients displayed measurable migration at 2 years: 6 patients with linear translations below 1 mm and 8 patients who showed rotational migration. Except for one outlier, the measured rotations were below 2°. The migration pattern suggested implant stability at 2 years. 10 patients showed radiolographic signs of "notching", and the mean Oxford Shoulder Score (OSS) at 2 years was 29 points (15-36 points).Interpretation - Stability analysis of the glenoid component of reversed total shoulder arthroplasty using reversed engineering (RE) model-based RSA indicated component stability at 2 years.
Collapse
Affiliation(s)
- Alexander Nilsskog Fraser
- Institute of Clinical Medicine; University of Oslo,Diakonhjemmet Hospital,Norway,Correspondence: Alexander Nilsskog FRASER,
| | - Berte Bøe
- Division of Orthopaedic Surgery, Oslo University Hospital
| | - Tore Fjalestad
- Division of Orthopaedic Surgery, Oslo University Hospital
| | - Jan Erik Madsen
- Division of Orthopaedic Surgery, Oslo University Hospital,Institute of Clinical Medicine; University of Oslo
| | | |
Collapse
|
8
|
Nyring MRK, Olsen BS, Yilmaz M, Petersen MM, Flivik G, Rasmussen JV. Early migration of stemless and stemmed humeral components after total shoulder arthroplasty for osteoarthritis-study protocol for a randomized controlled trial. Trials 2020; 21:830. [PMID: 33028390 PMCID: PMC7541322 DOI: 10.1186/s13063-020-04763-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2020] [Accepted: 09/22/2020] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND Glenohumeral osteoarthritis can, in the most severe cases, require surgery with insertion of a shoulder arthroplasty. A design with a stem in the humeral bone canal is currently regarded as the standard treatment option in patients who have an intact rotator cuff function, but complications related to the stem including humeral fractures can have devastating consequences. By using a stemless humeral component, stem-related complications can be reduced. The aim of this study is to compare the Comprehensive Nano stemless total shoulder arthroplasty (intervention group) with the Comprehensive stemmed total shoulder arthroplasty (control group). MATERIALS AND METHODS This is a randomized controlled trial comparing the stemless and the stemmed total shoulder arthroplasty. All Danish citizens with glenohumeral osteoarthritis indicating a total shoulder arthroplasty referred to the orthopedic department at Copenhagen University Hospital in Herlev/Gentofte will be offered participation. The following exclude from participation: below 18 years of age, cognitive or linguistic impairment, insufficient function of the rotator cuff, poor bone quality, and ASA groups 4-5. A total of 122 patients will be included of which 56 will be part of a radiostereometric analysis (RSA) study of humeral component migration. The primary outcomes are magnitude of migration of the humeral component assessed by RSA and patient-reported outcome by Western Ontario Osteoarthritis of the Shoulder index (WOOS). The secondary outcomes are additional patient-reported outcomes, functional outcome, readmission, complications, revisions, and changes in bone mineral density (BMD) of the proximal humerus assessed by duel energy x-ray absorptiometry (DXA) and economy (cost-utility analysis). The patients are examined before the operation and 3, 6, 12, and 24 months postoperative. DISCUSSION To our knowledge, RSA has never been used to access migration of a stemmed or a stemless humeral component nor has the stemmed and the stemless humeral component been compared with regard to pain relief and shoulder function in a randomized clinical trial. Today, the two designs are considered equal in the treatment of osteoarthritis. The study will provide surgeons and patients with information about shoulder arthroplasty for osteoarthritis and assist them in decision-making. TRIAL REGISTRATION ClinicalTrials.gov NCT04105478 . Registered on 25 September 2019.
Collapse
Affiliation(s)
- Marc Randall Kristensen Nyring
- Department of Orthopedic Surgery, Herlev and Gentofte Hospital, University of Copenhagen, Copenhagen, Denmark.
- Department of Orthopedic Surgery, Rigshospitalet, Copenhagen, Denmark.
| | - Bo S Olsen
- Department of Orthopedic Surgery, Herlev and Gentofte Hospital, University of Copenhagen, Copenhagen, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Müjgan Yilmaz
- Department of Orthopedic Surgery, Rigshospitalet, Copenhagen, Denmark
| | - Michael M Petersen
- Department of Orthopedic Surgery, Rigshospitalet, Copenhagen, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Gunnar Flivik
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
- Department of Orthopedic Surgery, Skaane University Hospital, Lund, Sweden
| | - Jeppe V Rasmussen
- Department of Orthopedic Surgery, Herlev and Gentofte Hospital, University of Copenhagen, Copenhagen, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
9
|
Brodén C, Giles JW, Popat R, Fetherston S, Olivecrona H, Sandberg O, Maguire GQ, Noz ME, Sköldenberg O, Emery R. Accuracy and precision of a CT method for assessing migration in shoulder arthroplasty: an experimental study. Acta Radiol 2020; 61:776-782. [PMID: 31684750 DOI: 10.1177/0284185119882659] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Radiostereometric analysis (RSA) is the gold standard to measure early implant migration which is a predictive factor for implant survival. PURPOSE To validate an alternative computed tomography (CT) technique to measure implant migration in shoulder arthroplasty. MATERIAL AND METHODS A cadaver proximal humerus and a scapula, which had tantalum beads incorporated within them, were prepared to accept a short-stemmed humeral component and a two-pegged glenoid component of a commercial total shoulder arthroplasty (TSA) system. A five degree of freedom micrometer and goniometer equipped rig was used to translate and rotate the implant components relative to the respective bone to predetermined positions. Double CT examinations were performed for each position and CT motion analysis software (CTMA) was used to assess these movements. The accuracy and precision of the software was estimated using the rig's micrometers and goniometers as the gold standard. The technique's effective dose was also assessed. RESULTS The accuracy was in the range of 0.07-0.23 mm in translation and 0.22-0.71° in rotation. The precision was in the range of 0.08-0.15 mm in translation and 0.23-0.54° in rotation. The mean effective dose for the CT scans was calculated to be 0.27 mSv. CONCLUSION In this experimental setting, accuracy, precision, and effective dose of the CTMA technique were found to be comparable to that of RSA. Therefore, we believe clinical studies are warranted to determine if CTMA is a suitable alternative to traditional RSA for migration measurements in TSA.
Collapse
Affiliation(s)
- Cyrus Brodén
- Department of Surgery and Cancer, Imperial College London, St Mary’s Hospital, London, UK
- Karolinska Institutet, Department of Clinical Sciences, Danderyd Hospital, Division of Orthopaedics, Stockholm, Sweden
| | - Joshua W Giles
- Department of Mechanical Engineering, University of Victoria, Victoria, BC, Canada
- Mechatronics in Medicine Laboratory, Mechanical Engineering, Imperial College London, London, UK
| | - Ravi Popat
- Department of Bioengineering, Imperial College London, London, UK
| | - Shirley Fetherston
- Department of Radiology, St Mary’s Hospital, Imperial College Healthcare NHS Trust, London, UK
| | - Henrik Olivecrona
- Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden
| | | | - Gerald Q Maguire
- School of Electrical Engineering and Computer Science, KTH Royal Institute of Technology, Stockholm, Sweden
| | - Marilyn E Noz
- Department of Radiology, New York University School of Medicine, New York, NY, USA
| | - Olof Sköldenberg
- Karolinska Institutet, Department of Clinical Sciences, Danderyd Hospital, Division of Orthopaedics, Stockholm, Sweden
| | - Roger Emery
- Department of Surgery and Cancer, Imperial College London, St Mary’s Hospital, London, UK
| |
Collapse
|
10
|
Craig RS, Goodier H, Singh JA, Hopewell S, Rees JL, Cochrane Musculoskeletal Group. Shoulder replacement surgery for osteoarthritis and rotator cuff tear arthropathy. Cochrane Database Syst Rev 2020; 4:CD012879. [PMID: 32315453 PMCID: PMC7173708 DOI: 10.1002/14651858.cd012879.pub2] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
BACKGROUND Shoulder replacement surgery is an established treatment for patients with end-stage glenohumeral osteoarthritis or rotator cuff tear arthropathy who have not improved with non-operative treatment. Different types of shoulder replacement are commonly used, but their relative benefits and risks compared versus one another and versus other treatments are uncertain. This expanded scope review is an update of a Cochrane Review first published in 2010. OBJECTIVES To determine the benefits and harms of shoulder replacement surgery in adults with osteoarthritis (OA) of the shoulder, including rotator cuff tear arthropathy (RCTA). SEARCH METHODS We searched the Cochrane Central Register of Controlled Trials, MEDLINE, Embase, CINAHL, SportDiscus, and Web of Science up to January 2019. We also searched clinical trial registers, conference proceedings, and reference lists from previous systematic reviews and included studies. SELECTION CRITERIA We included randomised studies comparing any type of shoulder replacement surgery versus any other surgical or non-surgical treatment, no treatment, or placebo. We also included randomised studies comparing any type of shoulder replacement or technique versus another. Study participants were adults with osteoarthritis of the glenohumeral joint or rotator cuff tear arthropathy. We assessed the following major outcomes: pain, function, participant-rated global assessment of treatment success, quality of life, adverse events, serious adverse events, and risk of revision or re-operation or treatment failure. DATA COLLECTION AND ANALYSIS Two review authors independently assessed trial quality and extracted data. We collected trial data on benefits and harms. MAIN RESULTS We included 20 studies involving 1083 participants (1105 shoulders). We found five studies comparing one type of shoulder replacement surgery to another type of shoulder replacement surgery, including three studies comparing conventional stemmed total shoulder replacement (TSR) surgery to stemmed humeral hemiarthroplasty. The remaining 15 studies compared one type of shoulder replacement to the same type of replacement performed with a technical modification or a different prosthetic component. We found no studies comparing shoulder replacement surgery to any other type of surgical treatment or to any type of non-surgical treatment. We found no studies comparing reverse total shoulder replacement surgery to any other type of treatment or to any type of replacement. Trial size varied from 16 to 161 participants. Participant mean age ranged from 63 to 81 years. 47% of participants were male. Sixteen trials reported participants with a diagnosis of osteoarthritis and intact rotator cuff tendons. Four trials reported patients with osteoarthritis and a rotator cuff tear or rotator cuff tear arthropathy. All studies were at unclear or high risk of bias for at least two domains, and only one study was free from high risk of bias (included in the main comparison). The most common sources of bias were lack of blinding of participants and assessors, attrition, and major baseline imbalance. Three studies allowed a comparison of conventional stemmed TSR surgery versus stemmed humeral hemiarthroplasty in people with osteoarthritis. At two years, low-quality evidence from two trials (downgraded for bias and imprecision) suggested there may be a small but clinically uncertain improvement in pain and function. On a scale of 0 to 10 (0 is no pain), mean pain was 2.78 points after stemmed humeral hemiarthroplasty and 1.49 points lower (0.1 lower to 2.88 lower) after conventional stemmed TSR. On a scale of 0 to 100 (100 = normal function), the mean function score was 72.8 points after stemmed humeral hemiarthroplasty and 10.57 points higher (2.11 higher to 19.02 higher) after conventional stemmed TSR. There may be no difference in quality of life based on low-quality evidence, downgraded for risk of bias and imprecision. On a scale of 0 to 100 (100 = normal), mean mental quality of life was rated as 57.4 points after stemmed humeral hemiarthroplasty and 1.0 point higher (5.1 lower to 7.1 higher) after conventional stemmed TSR. We are uncertain whether there is any difference in the rate of adverse events or the rate of revision, re-operation, or treatment failure based on very low-quality evidence (downgraded three levels for risk of bias and serious imprecision). The rate of any adverse event following stemmed humeral hemiarthroplasty was 286 per 1000, and following conventional stemmed TSR 143 per 1000, for an absolute difference of 14% fewer events (25% fewer to 21% more). Adverse events included fractures, dislocations, infections, and rotator cuff failure. The rate of revision, re-operation, or treatment failure was 103 per 1000, and following conventional stemmed TSR 77 per 1000, for an absolute difference of 2.6% fewer events (8% fewer to 15% more). Participant-rated global assessment of treatment success was not reported. AUTHORS' CONCLUSIONS Although it is an established procedure, no high-quality randomised trials have been conducted to determine whether shoulder replacement might be more effective than other treatments for osteoarthritis or rotator cuff tear arthropathy of the shoulder. We remain uncertain about which type or technique of shoulder replacement surgery is most effective in different situations. When humeral hemiarthroplasty was compared to TSR surgery for osteoarthritis, low-quality evidence led to uncertainty about whether there is a clinically important benefit for patient-reported pain or function and suggested there may be little or no difference in quality of life. Evidence is insufficient to show whether TSR is associated with greater or less risk of harm than humeral hemiarthroplasty. Available randomised studies did not provide sufficient data to reliably inform conclusions about adverse events and harm. Although reverse TSR is now the most commonly performed type of shoulder replacement, we found no studies comparing reverse TSR to any other type of treatment.
Collapse
Affiliation(s)
- Richard S Craig
- University of OxfordNuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences (NDORMS)Botnar Research CentreOld RoadOxfordUKOX3 7LD
| | - Henry Goodier
- University of OxfordNuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences (NDORMS)Botnar Research CentreOld RoadOxfordUKOX3 7LD
| | - Jasvinder A Singh
- Birmingham VA Medical CenterDepartment of MedicineFaculty Office Tower 805B510 20th Street SouthBirminghamALUSA35294
| | - Sally Hopewell
- University of OxfordNuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences (NDORMS)Botnar Research CentreOld RoadOxfordUKOX3 7LD
| | - Jonathan L Rees
- University of OxfordNuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences (NDORMS)Botnar Research CentreOld RoadOxfordUKOX3 7LD
| | | |
Collapse
|
11
|
Geervliet PC, Willems JH, Sierevelt IN, Visser CPJ, van Noort A. Overstuffing in resurfacing hemiarthroplasty is a potential risk for failure. J Orthop Surg Res 2019; 14:474. [PMID: 31888675 PMCID: PMC6936124 DOI: 10.1186/s13018-019-1522-1] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/26/2019] [Accepted: 12/17/2019] [Indexed: 12/17/2022] Open
Abstract
PURPOSE Literature describes the concern of an overstuffed shoulder joint after a resurfacing humeral head implant (RHHI). The purpose of this study was to evaluate inter-observer variability of (1) the critical shoulder angle (CSA), (2) the length of the gleno-humeral offset (LGHO), and (3) the anatomic center of rotation (COR) in a patient population operated with a Global Conservative Anatomic Prosthesis (CAP) RHHI. The measurements were compared between the revision and non-revision groups to find predictive indicators for failure. METHODS Pre- and postoperative radiographs were retrieved from 48 patients who underwent RHHI from 2007 to 2009 using a Global CAP hemiarthroplasty for end-stage osteoarthritis. This cohort consisted of 36 females (12 men) with a mean age of 77 years (SD 7.5). Two musculoskeletal radiologist and two specialized shoulder orthopedic surgeons measured the CSA, LGHO, and COR of all patients. RESULTS The inter-observer reliability showed excellent reliability for the CSA, LGHO, and the COR, varying between 0.91 and 0.98. The mean COR of the non-revision group was 4.9 mm (SD 2.5) compared to mean COR of the revision group, 8 mm (SD 2.2) (p < 0.01). The COR is the predictor of failure (OR 1.90 (95%Cl 1.19-3.02)) with a cut of point of 5.8 mm. The mean CSA was 29.8° (SD 3.9) There was no significant difference between the revision and non-revision groups (p = 0.34). The mean LGHO was 2.6 mm (SD 3.3) post-surgery. The mean LGHO of the revision group was 3.9 (SD 1.7) (p = 0.04) post-surgery. Despite the difference in mean LGHO, this is not a predictor for failure. CONCLUSION The CSA, LGHO, and COR can be used on radiographs and have a high inter-observer agreement. In contrast with the CSA and LGHO, we found a correlation between clinical failure and revision surgery in case of a deviation of the COR greater than 5 mm. TRIAL REGISTRATION Institutional review board, number: ACLU 2016.0054, Ethical Committee number: CBP M1330348. Registered 7 November 2006.
Collapse
Affiliation(s)
- Pieter C. Geervliet
- NoordWest Clinics, Department of Orthopedic Surgery, Shoulder Unit, Wilhelminalaan 12, 1815 JD Alkmaar, the Netherlands
| | - Jore H. Willems
- NoordWest Clinics, Department of Orthopedic Surgery, Shoulder Unit, Wilhelminalaan 12, 1815 JD Alkmaar, the Netherlands
| | | | | | - Arthur van Noort
- Spaarne Hospital, Spaarnepoort 1, 2134 TM Hoofddorp, the Netherlands
| |
Collapse
|
12
|
Sandau N, Brorson S, Olsen BS, Sørensen AK, Jensen SL, Schantz K, Ovesen J, Rasmussen JV. Low inter-observer agreement among experienced shoulder surgeons assessing overstuffing of glenohumeral resurfacing hemiarthroplasty based on plain radiographs. J Orthop Surg Res 2018; 13:299. [PMID: 30482217 PMCID: PMC6258391 DOI: 10.1186/s13018-018-1008-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/19/2017] [Accepted: 11/19/2018] [Indexed: 02/14/2023] Open
Abstract
Background In a clinical setting, a visual evaluation of post-implant radiographs is often used to assess the restoration of glenohumeral joint anatomy after resurfacing hemiarthroplasty and is a part of the decision-making process, in combination with other parameters, when evaluating patients with inferior clinical results. However, the reliability of this method of visual evaluation has not been reported. The aim of this study was to investigate the inter- and intra-observer agreement among experienced shoulder surgeons assessing overstuffing, implant positioning, and size following resurfacing hemiarthroplasty using plain standardized radiographs. Methods Six experienced shoulder surgeons independently classified implant inclination, size of the implant and if the joint seemed overstuffed, in 219 cases of post-implant radiographs. All cases were classified twice 3 weeks apart. Only radiographs with an anterior-posterior projection with a freely visible joint space were used. Non-weighted Cohen’s kappa values were calculated for each coder pair and the mean used as an estimate of the overall inter-observer agreement. Results The overall inter-observer agreement for implant size (kappa, 0.48 and 0.41) and inclination angle was moderate in both rounds (kappa, 0.46 and 0.44), but only a fair agreement was found concerning the evaluation for stuffing of the joint (kappa, 0.24 and 0.28). Intra-observer agreement for implant size and stuffing ranged from fair to substantial while the agreement for inclination was moderate to substantial. Conclusions Our results indicate that a visual evaluation of plain radiographs may be inadequate to evaluate overstuffing, implant positioning, and size following resurfacing hemiarthroplasty using plain standardized radiographs. Future studies may contribute to elucidate whether reliability increases if consensus on clear definitions and standardized methods of evaluation is made.
Collapse
Affiliation(s)
- Nicolai Sandau
- Department of Orthopedic Surgery, Herlev & Gentofte Hospital, Herlev Ringvej 75, 2730, Herlev, Denmark.
| | - Stig Brorson
- Department of Orthopedic Surgery, Zealand University Hospital, Lykkebækvej 1, 4600, Køge, Denmark
| | - Bo S Olsen
- Department of Orthopedic Surgery, Herlev & Gentofte Hospital, Herlev Ringvej 75, 2730, Herlev, Denmark
| | - Anne Kathrine Sørensen
- Department of Orthopedic Surgery, Herlev & Gentofte Hospital, Herlev Ringvej 75, 2730, Herlev, Denmark
| | - Steen L Jensen
- Department of Orthopedic Surgery, Aalborg University Hospital, Højgårdsvej 11, 9640, Farsø, Denmark
| | - Kim Schantz
- Department of Orthopedic Surgery, Zealand University Hospital, Lykkebækvej 1, 4600, Køge, Denmark
| | - Janne Ovesen
- Department of Orthopedic Surgery, Aarhus University Hospital, Palle Juul Jensens Boulevard 99, 8000, Aarhus, Denmark
| | - Jeppe V Rasmussen
- Department of Orthopedic Surgery, Herlev & Gentofte Hospital, Herlev Ringvej 75, 2730, Herlev, Denmark
| |
Collapse
|
13
|
Ten Brinke B, Beumer A, Koenraadt KLM, Eygendaal D, Kraan GA, Mathijssen NMC. The accuracy and precision of radiostereometric analysis in upper limb arthroplasty. Acta Orthop 2017; 88:320-325. [PMID: 28464752 PMCID: PMC5434603 DOI: 10.1080/17453674.2017.1291872] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Radiostereometric analysis (RSA) is an accurate method for measurement of early migration of implants. Since a relation has been shown between early migration and future loosening of total knee and hip prostheses, RSA plays an important role in the development and evaluation of prostheses. However, there have been few RSA studies of the upper limb, and the value of RSA of the upper limb is not yet clear. We therefore performed a systematic review to investigate the accuracy and precision of RSA of the upper limb. Patients and methods - PRISMA guidelines were followed and the protocol for this review was published online at PROSPERO under registration number CRD42016042014. A systematic search of the literature was performed in the databases Embase, Medline, Cochrane, Web of Science, Scopus, Cinahl, and Google Scholar on April 25, 2015 based on the keywords radiostereometric analysis, shoulder prosthesis, elbow prosthesis, wrist prosthesis, trapeziometacarpal joint prosthesis, humerus, ulna, radius, carpus. Articles concerning RSA for the analysis of early migration of prostheses of the upper limb were included. Quality assessment was performed using the MINORS score, Downs and Black checklist, and the ISO RSA Results - 23 studies were included. Precision values were in the 0.06-0.88 mm and 0.05-10.7° range for the shoulder, the 0.05-0.34 mm and 0.16-0.76° range for the elbow, and the 0.16-1.83 mm and 11-124° range for the TMC joint. Accuracy data from marker- and model-based RSA were not reported in the studies included. Interpretation - RSA is a highly precise method for measurement of early migration of orthopedic implants in the upper limb. However, the precision of rotation measurement is poor in some components. Challenges with RSA in the upper limb include the symmetrical shape of prostheses and the limited size of surrounding bone, leading to over-projection of the markers by the prosthesis. We recommend higher adherence to RSA guidelines and encourage investigators to publish long-term follow-up RSA studies.
Collapse
Affiliation(s)
- Bart Ten Brinke
- Department of Orthopaedic Surgery, Amphia Ziekenhuis, Breda;,Department of Orthopaedic Surgery, Reinier de Graaf Hospital, Delft;,Correspondence:
| | | | - Koen L M Koenraadt
- FORCE Foundation, Department of Orthopaedic Surgery, Amphia Ziekenhuis, Breda
| | - Denise Eygendaal
- Department of Orthopaedic Surgery, Amphia Ziekenhuis, Breda;,Department of Orthopaedic Surgery, Academic Medical Center, Amsterdam, the Netherlands
| | - Gerald A Kraan
- Department of Orthopaedic Surgery, Reinier de Graaf Hospital, Delft
| | | |
Collapse
|
14
|
Schmidutz F, Sprecher CM, Milz S, Gohlke F, Hertel R, Braunstein V. Resurfacing of the humeral head: An analysis of the bone stock and osseous integration under the implant. J Orthop Res 2015; 33:1382-90. [PMID: 25808101 DOI: 10.1002/jor.22902] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2014] [Accepted: 03/10/2015] [Indexed: 02/04/2023]
Abstract
Cementless-surface-replacement-arthroplasty (CSRA) of the shoulder aims for functional joint restoration with minimal bone loss. Good clinical results have been reported, but due to the radiopaque metal shell no data is available on the structure, osseous integration, and bone stock under the implant. 14 hemi-CSRAs (4 manufacturers) with two geometries (crown [n = 7]/ stem [n = 7] fixation) were retrieved from patients undergoing revision due to glenoidal erosion. Histological sections cutting through the implant centre and bone were analysed. Quantitative histomorphometry evaluated the bone-implant-contact and compared the bone-area to native humeral retrievals (n = 7). The bone-implant-interface was further assessed by scanning-electron-microscopy (SEM) and energy-dispersive-x-ray (EDX). Qualitative histology revealed a reduced and inhomogeneous bone stock. Obvious signs of stress shielding were observed with bone predominantly visible at the stem and implant rim. Quantitative histomorphometry confirmed the significantly reduced bone-area (9.2 ± 3.9% [crown 9.9 ± 4.3%, stem 8.6 ± 3.6%]) compared to native humeri (21.2 ± 9.1%; p < 0.05). Bone-implant-contact was 20.5 ± 5.8% (crown 21.8 ± 6.2%, stem 19.2 ± 5.6%) which was confirmed by SEM and EDX. Altogether, CRSA shows satisfactory bone ingrowth at the interface suggesting sufficient primary stability to allow osseous integration. However, clear signs of stress shielding with an inhomogeneous and reduced bone stock were observed. The impact on the long-term-results is unclear requiring further investigation.
Collapse
Affiliation(s)
- Florian Schmidutz
- AO Research Institute Davos, Switzerland.,Department of Orthopaedic Surgery, University of Munich (LMU), Germany
| | | | - Stefan Milz
- AO Research Institute Davos, Switzerland.,University of Munich (LMU), Anatomische Anstalt, Germany
| | | | | | - Volker Braunstein
- AO Research Institute Davos, Switzerland.,Ortho-Plus Munich, Germany.,Department of General-, Trauma-, Hand and Plastic Surgery, University of Munich (LMU), Germany
| |
Collapse
|