1
|
Salimi-Jazi F, Thomas AL, Wood LSY, Rafeeqi T, Axelrod S, Navalgund A, Axelrod L, Dunn JCY. Perioperative Gastrointestinal Myoelectric Activity Measurement Using Wireless External Patches. J Surg Res 2024; 302:186-199. [PMID: 39098117 PMCID: PMC11490404 DOI: 10.1016/j.jss.2024.07.037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Revised: 07/01/2024] [Accepted: 07/07/2024] [Indexed: 08/06/2024]
Abstract
BACKGROUND Stomach, small intestine, and colon have distinct patterns of contraction related to their function to mix and propel enteric contents. In this study, we aim to measure gut myoelectric activity in the perioperative course using external patches in an animal model. METHODS Four external patches were placed on the abdominal skin of female Yucatan pigs to record gastrointestinal myoelectric signals for 3 to 5 d. Pigs subsequently underwent anesthesia and placement of internal electrodes on stomach, small intestine, and colon. Signals were collected by a wireless transmitter. Frequencies associated with peristalsis were analyzed for both systems for 6 d postoperatively. RESULTS In awake pigs, we found frequency peaks in several ranges, from 4 to 6.5 cycles per minute (CPM), 8 to 11 CPM, and 14 to 18 CPM, which were comparable between subjects and concordant between internal and external recordings. The possible effect of anesthesia during the 1 or 2 h before surgical manipulation was observed as a 59% (±36%) decrease in overall myoelectric activity compared to the immediate time before anesthesia. The myoelectrical activity recovered quickly postoperatively. Comparing the absolute postsurgery activity levels to the baseline for each pig revealed higher overall activity after surgery by a factor of 1.69 ± 0.3. CONCLUSIONS External patch measurements correlated with internal electrode recordings. Anesthesia and surgery impacted gastrointestinal myoelectric activity. Recordings demonstrated a rebound phenomenon in myoelectric activity in the postoperative period. The ability to monitor gastrointestinal tract myoelectric activity noninvasively over multiple days could be a useful tool in diagnosing gastrointestinal motility disorders.
Collapse
Affiliation(s)
- Fereshteh Salimi-Jazi
- Division of Pediatric Surgery, Department of Surgery, Stanford University School of Medicine, Stanford, California
| | - Anne-Laure Thomas
- Division of Pediatric Surgery, Department of Surgery, Stanford University School of Medicine, Stanford, California
| | - Lauren S Y Wood
- Division of Pediatric Surgery, Department of Surgery, Stanford University School of Medicine, Stanford, California
| | - Talha Rafeeqi
- Division of Pediatric Surgery, Department of Surgery, Stanford University School of Medicine, Stanford, California
| | - Steve Axelrod
- G-Tech Medical, Fogarty Innovation, Mountain View, California
| | - Anand Navalgund
- G-Tech Medical, Fogarty Innovation, Mountain View, California
| | - Lindsay Axelrod
- G-Tech Medical, Fogarty Innovation, Mountain View, California
| | - James C Y Dunn
- Division of Pediatric Surgery, Department of Surgery, Stanford University School of Medicine, Stanford, California; Department of Bioengineering, Stanford University, Stanford, California.
| |
Collapse
|
2
|
Oczka D, Augustynek M, Penhaker M, Kubicek J. Electrogastrography measurement systems and analysis methods used in clinical practice and research: comprehensive review. Front Med (Lausanne) 2024; 11:1369753. [PMID: 39011457 PMCID: PMC11248517 DOI: 10.3389/fmed.2024.1369753] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Accepted: 06/03/2024] [Indexed: 07/17/2024] Open
Abstract
Electrogastrography (EGG) is a non-invasive method with high diagnostic potential for the prevention of gastroenterological pathologies in clinical practice. In this study, a review of the measurement systems, procedures, and methods of analysis used in electrogastrography is presented. A critical review of historical and current literature is conducted, focusing on electrode placement, measurement apparatus, measurement procedures, and time-frequency domain methods of filtration and analysis of the non-invasively measured electrical activity of the stomach. As a result, 129 relevant articles with primary aim on experimental diet were reviewed in this study. Scopus, PubMed, and Web of Science databases were used to search for articles in English language, according to the specific query and using the PRISMA method. The research topic of electrogastrography has been continuously growing in popularity since the first measurement by professor Alvarez 100 years ago, and there are many researchers and companies interested in EGG nowadays. Measurement apparatus and procedures are still being developed in both commercial and research settings. There are plenty variable electrode layouts, ranging from minimal numbers of electrodes for ambulatory measurements to very high numbers of electrodes for spatial measurements. Most authors used in their research anatomically approximated layout with two++ active electrodes in bipolar connection and commercial electrogastrograph with sampling rate of 2 or 4 Hz. Test subjects were usually healthy adults and diet was controlled. However, evaluation methods are being developed at a slower pace, and usually the signals are classified only based on dominant frequency. The main review contributions include the overview of spectrum of measurement systems and procedures for electrogastrography developed by many authors, but a firm medical standard has not yet been defined. Therefore, it is not possible to use this method in clinical practice for objective diagnosis. Systematic Review Registration https://www.prisma-statement.org/.
Collapse
Affiliation(s)
- David Oczka
- Department of Cybernetics and Biomedical Engineering, VSB-Technical University of Ostrava, Ostrava, Czechia
| | - Martin Augustynek
- Department of Cybernetics and Biomedical Engineering, VSB-Technical University of Ostrava, Ostrava, Czechia
| | - Marek Penhaker
- Department of Cybernetics and Biomedical Engineering, VSB-Technical University of Ostrava, Ostrava, Czechia
| | - Jan Kubicek
- Department of Cybernetics and Biomedical Engineering, VSB-Technical University of Ostrava, Ostrava, Czechia
| |
Collapse
|
3
|
Seo SHB, Wells CI, Dickson T, Rowbotham D, Gharibans A, Calder S, Bissett I, O'Grady G, Erickson JC. Validation of body surface colonic mapping (BSCM) against high resolution colonic manometry for evaluation of colonic motility. Sci Rep 2024; 14:4842. [PMID: 38418514 PMCID: PMC10902299 DOI: 10.1038/s41598-024-54429-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Accepted: 02/13/2024] [Indexed: 03/01/2024] Open
Abstract
Abnormal cyclic motor pattern (CMP) activity is implicated in colonic dysfunction, but the only tool to evaluate CMP activity, high-resolution colonic manometry (HRCM), remains expensive and not widely accessible. This study aimed to validate body surface colonic mapping (BSCM) through direct correlation with HRCM. Synchronous meal-test recordings were performed in asymptomatic participants with intact colons. A signal processing method for BSCM was developed to detect CMPs. Quantitative temporal analysis was performed comparing the meal responses and motility indices (MI). Spatial heat maps were also compared. Post-study questionnaires evaluated participants' preference and comfort/distress experienced from either test. 11 participants were recruited and 7 had successful synchronous recordings (5 females/2 males; median age: 50 years [range 38-63]). The best-correlating MI temporal analyses achieved a high degree of agreement (median Pearson correlation coefficient (Rp) value: 0.69; range 0.47-0.77). HRCM and BSCM meal response start and end times (Rp = 0.998 and 0.83; both p < 0.05) and durations (Rp = 0.85; p = 0.03) were similar. Heat maps demonstrated good spatial agreement. BSCM is the first non-invasive method to be validated by demonstrating a direct spatio-temporal correlation to manometry in evaluating colonic motility.
Collapse
Affiliation(s)
- Sean H B Seo
- Department of Surgery, The University of Auckland, Auckland, New Zealand
| | - Cameron I Wells
- Department of Surgery, The University of Auckland, Auckland, New Zealand
- Department of Surgery, Auckland District Health Board, Auckland, New Zealand
| | - Tully Dickson
- Department of Surgery, The University of Auckland, Auckland, New Zealand
| | - David Rowbotham
- Department of Gastroenterology, Auckland City Hospital, Te Whatu Ora Health New Zealand, Auckland, New Zealand
| | - Armen Gharibans
- Alimetry Ltd, Auckland, New Zealand
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Stefan Calder
- Alimetry Ltd, Auckland, New Zealand
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Ian Bissett
- Department of Surgery, The University of Auckland, Auckland, New Zealand
- Department of Surgery, Auckland District Health Board, Auckland, New Zealand
| | - Greg O'Grady
- Department of Surgery, The University of Auckland, Auckland, New Zealand
- Alimetry Ltd, Auckland, New Zealand
| | - Jonathan C Erickson
- Alimetry Ltd, Auckland, New Zealand.
- Department of Physics and Engineering, Washington and Lee University, Lexington, USA.
| |
Collapse
|
4
|
Drake CE, Cheng LK, Muszynski ND, Somarajan S, Paskaranandavadivel N, Angeli-Gordon TR, Du P, Bradshaw LA, Avci R. Electroanatomical mapping of the stomach with simultaneous biomagnetic measurements. Comput Biol Med 2023; 165:107384. [PMID: 37633085 DOI: 10.1016/j.compbiomed.2023.107384] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 07/17/2023] [Accepted: 08/14/2023] [Indexed: 08/28/2023]
Abstract
Gastric motility is coordinated by bioelectric slow waves (SWs) and dysrhythmic SW activity has been linked with motility disorders. Magnetogastrography (MGG) is the non-invasive measurement of the biomagnetic fields generated by SWs. Dysrhythmia identification using MGG is currently challenging because source models are not well developed and the impact of anatomical variation is not well understood. A novel method for the quantitative spatial co-registration of serosal SW potentials, MGG, and geometric models of anatomical structures was developed and performed on two anesthetized pigs to verify feasibility. Electrode arrays were localized using electromagnetic transmitting coils. Coil localization error for the volume where the stomach is normally located under the sensor array was assessed in a benchtop experiment, and mean error was 4.2±2.3mm and 3.6±3.3° for a coil orientation parallel to the sensor array and 6.2±5.7mm and 4.5±7.0° for a perpendicular coil orientation. Stomach geometries were reconstructed by fitting a generic stomach to up to 19 localization coils, and SW activation maps were mapped onto the reconstructed geometries using the registered positions of 128 electrodes. Normal proximal-to-distal and ectopic SW propagation patterns were recorded from the serosa and compared against the simultaneous MGG measurements. Correlations between the center-of-gravity of normalized MGG and the mean position of SW activity on the serosa were 0.36 and 0.85 for the ectopic and normal propagation patterns along the proximal-distal stomach axis, respectively. This study presents the first feasible method for the spatial co-registration of MGG, serosal SW measurements, and subject-specific anatomy. This is a significant advancement because these data enable the development and validation of novel non-invasive gastric source characterization methods.
Collapse
Affiliation(s)
- Chad E Drake
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Leo K Cheng
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand; Department of Surgery, Vanderbilt University, Nashville, TN, USA
| | | | | | | | | | - Peng Du
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | | | - Recep Avci
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand.
| |
Collapse
|