Ishiyama Y, Hirano Y, Minagawa Y, Yamato M, Akuta S, Nakanishi A, Fujii T, Okazaki N, Hiranuma C, Koyama I. A Case of Transanal Total Mesorectal Excision Using the Senhance Digital Laparoscopy System for Rectal Cancer. Surg Case Rep 2025; 11:24-0024. [PMID: 39991492 PMCID: PMC11842874 DOI: 10.70352/scrj.cr.24-0024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2024] [Accepted: 12/09/2024] [Indexed: 02/25/2025] Open
Abstract
INTRODUCTION This case report presents the world's first transanal total mesorectal excision (taTME) using the Senhance Digital Laparoscopy System for rectal cancer. Senhance has been gaining attention as an advanced surgical robot, providing better visualization, stable dissection, and reduced surgeon fatigue compared to conventional methods. CASE PRESENTATION A 68-year-old woman underwent Senhance-assisted taTME for a rectal tumor located 4 cm from the anal verge. The procedure was completed safely with a total operation time of 209 minutes, a cockpit time of 85 minutes, and a blood loss of 40 mL. Pathological evaluation confirmed complete resection (R0) with no residual cancer or lymph node metastases. The patient was discharged on postoperative day 7 without complications. CONCLUSIONS This case demonstrates the potential advantages of Senhance-assisted taTME, including improved visualization, stable dissection, and reduced surgeon fatigue. Further studies are needed to evaluate long-term outcomes and establish the role of this technique in rectal cancer surgery.
Collapse
Affiliation(s)
- Yasuhiro Ishiyama
- Department of Gastroenterological Surgery, Saitama Medical University International Medical Center, Hidaka, Saitama, Japan
| | - Yasumitsu Hirano
- Department of Gastroenterological Surgery, Saitama Medical University International Medical Center, Hidaka, Saitama, Japan
| | - Yume Minagawa
- Department of Gastroenterological Surgery, Saitama Medical University International Medical Center, Hidaka, Saitama, Japan
| | - Misuzu Yamato
- Department of Gastroenterological Surgery, Saitama Medical University International Medical Center, Hidaka, Saitama, Japan
| | - Sohei Akuta
- Department of Gastroenterological Surgery, Saitama Medical University International Medical Center, Hidaka, Saitama, Japan
| | - Akihito Nakanishi
- Department of Gastroenterological Surgery, Saitama Medical University International Medical Center, Hidaka, Saitama, Japan
| | - Takatsugu Fujii
- Department of Gastroenterological Surgery, Saitama Medical University International Medical Center, Hidaka, Saitama, Japan
| | - Naoto Okazaki
- Department of Gastroenterological Surgery, Saitama Medical University International Medical Center, Hidaka, Saitama, Japan
| | - Chikashi Hiranuma
- Department of Gastroenterological Surgery, Saitama Medical University International Medical Center, Hidaka, Saitama, Japan
| | - Isamu Koyama
- Department of Gastroenterological Surgery, Saitama Medical University International Medical Center, Hidaka, Saitama, Japan
| |
Collapse
|
2
|
Fujii T, Hirano Y, Ishiyama Y, Yamato M, Akuta S, Yoshizawa M, Okazaki N, Hiranuma C. Comparison of short- and mid-term outcomes between the Senhance digital laparoscopic system and laparoscopic colectomy: a propensity score matching study. Surg Endosc 2025; 39:1153-1159. [PMID: 39715957 DOI: 10.1007/s00464-024-11482-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2024] [Accepted: 12/08/2024] [Indexed: 12/25/2024]
Abstract
BACKGROUND The Senhance digital laparoscopic system (Senhance) is a surgical robot approved for use in Japan after the da Vinci system. Our institution was the first to introduce this system, which has been used primarily for gastrointestinal surgery. Featuring tactile feedback, eye-movement-controlled camera operation, stereoscopic vision, and magnification, the short-term postoperative outcomes of the Senhance in abdominal surgery have been documented. This study aimed to evaluate the safety and feasibility of Senhance by examining mid-term postoperative outcomes. METHODS Between January 2018 and December 2020, 743 patients underwent colorectal cancer colectomy at our institution. We compared 50 cases of Senhance-assisted colectomy with 430 laparoscopic colectomy cases using 1:1 propensity score matching, adjusting for covariates such as sex, age, tumor location, BMI, ASA-PS, cT, and cN. Short- and mid-term surgical outcomes were compared between the Senhance (S) and laparoscopic (L) groups. RESULTS After matching, 47 patients were included in each group. There were no significant differences in the patient backgrounds. The operative time was significantly longer in the S group compared to the L group (median: 240 [101-378] minutes vs. 191 [100-370] minutes, p < 0.01). No significant differences were observed in postoperative complications of Clavien-Dindo grade 2 or higher within 30 days post-surgery, and no robot-related adverse events were reported. The 3-year disease-free survival rates were 88.7% in the S group and 77.1% in the L group (p = 0.178; HR, 1.423; 95% CI 0.916-2.211). The overall survival rate was 97.7% in both groups (p = 0.897; HR, 1.202; 95% CI 0.075-19.26). CONCLUSION Senhance-assisted colectomy is safe with mid-term outcomes comparable to laparoscopic surgery. However, the extended operation time remains challenging, necessitating further studies, including randomized controlled trials and multicenter studies, to validate these findings.
Collapse
Affiliation(s)
- Takatsugu Fujii
- Department of Gastrointestinal Surgery, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka-City, Saitama, Japan.
| | - Yasumitsu Hirano
- Department of Gastrointestinal Surgery, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka-City, Saitama, Japan
| | - Yasuhiro Ishiyama
- Department of Gastrointestinal Surgery, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka-City, Saitama, Japan
| | - Misuzu Yamato
- Department of Gastrointestinal Surgery, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka-City, Saitama, Japan
| | - Sohei Akuta
- Department of Gastrointestinal Surgery, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka-City, Saitama, Japan
| | - Masatoshi Yoshizawa
- Department of Gastrointestinal Surgery, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka-City, Saitama, Japan
| | - Naoto Okazaki
- Department of Gastrointestinal Surgery, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka-City, Saitama, Japan
| | - Chikashi Hiranuma
- Department of Gastrointestinal Surgery, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka-City, Saitama, Japan
| |
Collapse
|
3
|
Subramaniam S, Piozzi GN, Kim SH, Khan JS. Robotic approach to colonic resection: For some or for all patients? Colorectal Dis 2024; 26:1447-1455. [PMID: 38812078 DOI: 10.1111/codi.17046] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/30/2024] [Accepted: 05/08/2024] [Indexed: 05/31/2024]
Abstract
The robotic approach is rapidly gaining momentum in colorectal surgery. Its benefits in pelvic surgery have been extensively discussed and are well established amongst those who perform minimally invasive surgery. However, the same cannot be said for the robotic approach for colonic resection, where its role is still debated. Here we aim to provide an extensive debate between selective and absolute use of the robotic approach for colonic resection by combining the thoughts of experts in the field of robotic and minimally invasive colorectal surgery, dissecting all key aspects for a critical view on this exciting new paradigm in colorectal surgery.
Collapse
Affiliation(s)
- Sentilnathan Subramaniam
- Colorectal Surgery Unit, Department of General Surgery, Hospital Selayang, Selangor, Malaysia
- Department of Colorectal Surgery, Portsmouth Hospitals University NHS Trust, Portsmouth, UK
| | | | - Seon-Hahn Kim
- Colorectal Unit, Department of Surgery, Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia
| | - Jim S Khan
- Department of Colorectal Surgery, Portsmouth Hospitals University NHS Trust, Portsmouth, UK
- University of Portsmouth, Portsmouth, UK
| |
Collapse
|
4
|
Long Z, Chi Y, Zhang X, Li H, Yang D, Li D, Jiang Z. An EM-Tracked Approach for Calibrating the 3D Pose of Flexible Endoscopes. Ann Biomed Eng 2024; 52:1435-1447. [PMID: 38402316 DOI: 10.1007/s10439-024-03469-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Accepted: 02/06/2024] [Indexed: 02/26/2024]
Abstract
Flexible endoscopes are ideal instruments for visualizing and diagnosing the inner surfaces of organs via a minimally invasive incision. Calibrating a flexible endoscope is a troublesome yet inevitable process in image-based tools tracking. Aiming to simplify the calibration process, we propose an electromagnetic (EM)-tracked calibration approach that does not require any predefined poses of the EM sensor. A three-stage calibration protocol was presented in an extensor. First, the orientation of the endoscope tube was derived by conducting a circular rotation of the endoscope around its axis utilizing a pair of tightly bearing stands. Second, the 3D position of the endoscope tip was acquired by having the tip come into contact with a flat plane. Third, the pose model of the bending section was derived and transformed into the local coordinate system of the EM sensor attached to the endoscope handle. To assess the accuracy of the proposed calibration approach, two experiments were designed and performed. Experimental results indicate accuracies of 0.09 ± 0.06 deg and 0.03 ± 0.19 deg in the estimation of the endoscope tube orientation and 0.52 ± 0.29, 0.33 ± 0.11, and 0.29 ± 0.17 mm in the x, y, and z estimations of the endoscope tip position, respectively. The proposed approach is accurate and easy to operate, does not require the employment of custom calibration markers, and can be used not only in surgical training systems but also in the endoscopic-based tools tracking.
Collapse
Affiliation(s)
- Zhongjie Long
- Key Laboratory of the Ministry of Education for Modern Measurement & Control Technology, and School of Electromechanical Engineering, Beijing Information Science & Technology University, Beijing, 100192, China.
| | - Yongting Chi
- Key Laboratory of the Ministry of Education for Modern Measurement & Control Technology, and School of Electromechanical Engineering, Beijing Information Science & Technology University, Beijing, 100192, China
| | - Xianbo Zhang
- Key Laboratory of the Ministry of Education for Modern Measurement & Control Technology, and School of Electromechanical Engineering, Beijing Information Science & Technology University, Beijing, 100192, China
| | - Hongbing Li
- Department of Instrument Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Dejin Yang
- Beijing Jishuitan Hospital, Capital Medical School, 4th Clinical College of Peking University, Beijing, 100035, China
| | - Diangeng Li
- Department of Nephrology, Beijing Chao-yang Hospital, Capital Medical University, Beijing, 100020, China
| | - Zhouxiang Jiang
- Key Laboratory of the Ministry of Education for Modern Measurement & Control Technology, and School of Electromechanical Engineering, Beijing Information Science & Technology University, Beijing, 100192, China
| |
Collapse
|
5
|
Boal MWE, Anastasiou D, Tesfai F, Ghamrawi W, Mazomenos E, Curtis N, Collins JW, Sridhar A, Kelly J, Stoyanov D, Francis NK. Evaluation of objective tools and artificial intelligence in robotic surgery technical skills assessment: a systematic review. Br J Surg 2024; 111:znad331. [PMID: 37951600 PMCID: PMC10771126 DOI: 10.1093/bjs/znad331] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Revised: 09/18/2023] [Accepted: 09/19/2023] [Indexed: 11/14/2023]
Abstract
BACKGROUND There is a need to standardize training in robotic surgery, including objective assessment for accreditation. This systematic review aimed to identify objective tools for technical skills assessment, providing evaluation statuses to guide research and inform implementation into training curricula. METHODS A systematic literature search was conducted in accordance with the PRISMA guidelines. Ovid Embase/Medline, PubMed and Web of Science were searched. Inclusion criterion: robotic surgery technical skills tools. Exclusion criteria: non-technical, laparoscopy or open skills only. Manual tools and automated performance metrics (APMs) were analysed using Messick's concept of validity and the Oxford Centre of Evidence-Based Medicine (OCEBM) Levels of Evidence and Recommendation (LoR). A bespoke tool analysed artificial intelligence (AI) studies. The Modified Downs-Black checklist was used to assess risk of bias. RESULTS Two hundred and forty-seven studies were analysed, identifying: 8 global rating scales, 26 procedure-/task-specific tools, 3 main error-based methods, 10 simulators, 28 studies analysing APMs and 53 AI studies. Global Evaluative Assessment of Robotic Skills and the da Vinci Skills Simulator were the most evaluated tools at LoR 1 (OCEBM). Three procedure-specific tools, 3 error-based methods and 1 non-simulator APMs reached LoR 2. AI models estimated outcomes (skill or clinical), demonstrating superior accuracy rates in the laboratory with 60 per cent of methods reporting accuracies over 90 per cent, compared to real surgery ranging from 67 to 100 per cent. CONCLUSIONS Manual and automated assessment tools for robotic surgery are not well validated and require further evaluation before use in accreditation processes.PROSPERO: registration ID CRD42022304901.
Collapse
Affiliation(s)
- Matthew W E Boal
- The Griffin Institute, Northwick Park & St Marks’ Hospital, London, UK
- Wellcome/ESPRC Centre for Interventional Surgical Sciences (WEISS), University College London (UCL), London, UK
- Division of Surgery and Interventional Science, Research Department of Targeted Intervention, UCL, London, UK
| | - Dimitrios Anastasiou
- Wellcome/ESPRC Centre for Interventional Surgical Sciences (WEISS), University College London (UCL), London, UK
- Medical Physics and Biomedical Engineering, UCL, London, UK
| | - Freweini Tesfai
- The Griffin Institute, Northwick Park & St Marks’ Hospital, London, UK
- Wellcome/ESPRC Centre for Interventional Surgical Sciences (WEISS), University College London (UCL), London, UK
| | - Walaa Ghamrawi
- The Griffin Institute, Northwick Park & St Marks’ Hospital, London, UK
| | - Evangelos Mazomenos
- Wellcome/ESPRC Centre for Interventional Surgical Sciences (WEISS), University College London (UCL), London, UK
- Medical Physics and Biomedical Engineering, UCL, London, UK
| | - Nathan Curtis
- Department of General Surgey, Dorset County Hospital NHS Foundation Trust, Dorchester, UK
| | - Justin W Collins
- Division of Surgery and Interventional Science, Research Department of Targeted Intervention, UCL, London, UK
- University College London Hospitals NHS Foundation Trust, London, UK
| | - Ashwin Sridhar
- Division of Surgery and Interventional Science, Research Department of Targeted Intervention, UCL, London, UK
- University College London Hospitals NHS Foundation Trust, London, UK
| | - John Kelly
- Division of Surgery and Interventional Science, Research Department of Targeted Intervention, UCL, London, UK
- University College London Hospitals NHS Foundation Trust, London, UK
| | - Danail Stoyanov
- Wellcome/ESPRC Centre for Interventional Surgical Sciences (WEISS), University College London (UCL), London, UK
- Computer Science, UCL, London, UK
| | - Nader K Francis
- The Griffin Institute, Northwick Park & St Marks’ Hospital, London, UK
- Division of Surgery and Interventional Science, Research Department of Targeted Intervention, UCL, London, UK
- Yeovil District Hospital, Somerset Foundation NHS Trust, Yeovil, Somerset, UK
| |
Collapse
|
6
|
Koo B, Son K, Lee JM, Kim SY, Jin MU, Lee KB. Prediction of learning curves of wired and wireless intraoral scanners. Sci Rep 2023; 13:21661. [PMID: 38066236 PMCID: PMC10709622 DOI: 10.1038/s41598-023-48855-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2023] [Accepted: 11/30/2023] [Indexed: 12/18/2023] Open
Abstract
This clinical study aimed to predict the learning curve of wireless and wired intraoral scanners (IOSs) and to compare the reduction patterns of working time. Overall, 14 participants were enrolled in the study. The intraoral scanning procedure was repeated four times, each using wireless and wired IOSs (i700; MEDIT). The work time from the first to the 600th iterations was predicted using the Wright model. Regarding statistical analysis, the Mann-Whitney U-test was performed for comparison between wireless and wired IOSs and between groups with and without an IOS usage experience, and the Friedman test was performed to evaluate the time reduction (α = 0.05). There was a significant difference between wireless and wired IOSs in the first (P = 0.008) and the third (P = 0.035) iterations. Moreover, the time for 600 iterations was statistically significantly different between wireless and wired IOSs (P < 0.05); however, there was no significant difference after the sixth iteration (e.g., seventh iteration: P = 0.062). In wireless IOS, no significant difference was found between participants with and without an IOS usage experience after the 34th iteration (P = 0.053). The difference in the learning effect between wireless and wired IOSs can be overcome by initial learning; however, an IOS usage experience can affect the learning time of wireless IOSs.
Collapse
Affiliation(s)
- Boncheol Koo
- Department of Prosthodontics, School of Dentistry, Kyungpook National University, 2177 Dalgubuldaero, Jung-gu, Daegu, 41940, Republic of Korea
| | - Keunbada Son
- Advanced Dental Device Development Institute (A3DI), Kyungpook National University, Daegu, Republic of Korea
| | - Ji-Min Lee
- Advanced Dental Device Development Institute (A3DI), Kyungpook National University, Daegu, Republic of Korea
- Department of Dental Science, Graduate School, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea
| | - So-Yeun Kim
- Department of Prosthodontics, School of Dentistry, Kyungpook National University, 2177 Dalgubuldaero, Jung-gu, Daegu, 41940, Republic of Korea
| | - Myoung-Uk Jin
- Department of Conservative Dentistry, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea.
| | - Kyu-Bok Lee
- Department of Prosthodontics, School of Dentistry, Kyungpook National University, 2177 Dalgubuldaero, Jung-gu, Daegu, 41940, Republic of Korea.
- Advanced Dental Device Development Institute (A3DI), Kyungpook National University, Daegu, Republic of Korea.
| |
Collapse
|
7
|
Kim M, Zhang Y, Jin S. Soft tissue surgical robot for minimally invasive surgery: a review. Biomed Eng Lett 2023; 13:561-569. [PMID: 37872994 PMCID: PMC10590359 DOI: 10.1007/s13534-023-00326-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Revised: 09/08/2023] [Accepted: 09/26/2023] [Indexed: 10/25/2023] Open
Abstract
Purpose The current state of soft tissue surgery robots is surveyed, and the key technologies underlying their success are analyzed. State-of-the-art technologies are introduced, and future directions are discussed. Methods Relevant literature is explored, analyzed, and summarized. Results Soft tissue surgical robots had rapidly spread in the field of laparoscopic surgery based on the multi-degree-of-freedom movement of intra-abdominal surgical tools and stereoscopic imaging that are not possible in conventional surgery. The three key technologies that have made surgical robots successful are wire-driven mechanisms for multi-degree-of-freedom movement, master devices for intuitive remote control, and stereoscopic imaging technology. Recently, human-robot interaction technologies have been applied to develop user interfaces such as vision assistance and haptic feedback, and research on autonomous surgery has begun. Conclusion Robotic surgery not only replaces conventional laparoscopic surgery but also allows for complex surgeries that are not possible with laparoscopic surgery. On the other hand, it is also criticized for its high cost and lack of clinical superiority or patient benefit compared to conventional laparoscopic surgery. As various robots compete in the market, the cost of surgical robots is expected to decrease. Surgical robots are expected to continue to evolve in the future due to the need to reduce the workload of medical staff and improve the level of care demanded by patients.
Collapse
Affiliation(s)
- Minhyo Kim
- School of Mechanical Engineering, Pusan National University, 2, Busandaehak-ro 63beon-gil, Geumjeong-gu, Busan, 46241 Republic of Korea
| | - Youqiang Zhang
- School of Mechanical Engineering, Pusan National University, 2, Busandaehak-ro 63beon-gil, Geumjeong-gu, Busan, 46241 Republic of Korea
| | - Sangrok Jin
- School of Mechanical Engineering, Pusan National University, 2, Busandaehak-ro 63beon-gil, Geumjeong-gu, Busan, 46241 Republic of Korea
| |
Collapse
|
8
|
Krebs TF, Kayser T, Lorenzen U, Grünewald M, Kayser M, Saltner A, Durmaz LO, Reese LJ, Brownlee E, Reischig K, Baastrup J, Meinzer A, Kalz A, Becker T, Bergholz R. Evaluation of the Versius Robotic System for Infant Surgery-A Study in Piglets of Less than 10 kg Body Weight. CHILDREN (BASEL, SWITZERLAND) 2023; 10:children10050831. [PMID: 37238379 DOI: 10.3390/children10050831] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/11/2023] [Revised: 04/19/2023] [Accepted: 04/21/2023] [Indexed: 05/28/2023]
Abstract
BACKGROUND We were able to demonstrate the feasibility of a new robotic system (Versius, CMR Surgical, Cambridge, UK) for procedures in small inanimate cavities. The aim of this consecutive study was to test the Versius® system for its feasibility, performance, and safety of robotic abdominal and thoracic surgery in piglets simulating infants with a body weight lower than 10 kg. METHODS A total of 24 procedures (from explorative laparoscopy to thoracoscopic esophageal repair) were performed in 4 piglets with a mean age of 12 days and a mean body weight of 6.4 (7-7.5) kg. Additional urological procedures were performed after euthanasia of the piglet. The Versius® robotic system was used with 5 mm wristed instruments and a 10 mm 3D 0° or 30° camera. The setup consisted of the master console and three to four separate arms. The performance of the procedure, the size, position, and the distance between the ports, the external and internal collisions, and complications of the procedures were recorded and analyzed. RESULTS We were able to perform all surgical procedures as planned. We encountered neither surgical nor robot-associated complications in the live model. Whereas all abdominal procedures could be performed successfully under general anesthesia, one piglet was euthanized early before the thoracic interventions, likely due to pulmonary inflammatory response. Technical limitations were based on the size of the camera (10 mm) being too large and the minimal insertion depth of the instruments for calibration of the fulcrum point. CONCLUSIONS Robotic surgery on newborns and infants appears technically feasible with the Versius® system. Software adjustments for fulcrum point calibration need to be implemented by the manufacturer as a result of our study. To further evaluate the Versius® system, prospective trials are needed, comparing it to open and laparoscopic surgery as well as to other robotic systems.
Collapse
Affiliation(s)
- Thomas Franz Krebs
- Department of General-, Visceral-, Thoracic-, Transplant- and Pediatric Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
- Department of Pediatric Surgery, Ostschweizer Children's Hospital, Claudiusstrasse 6, 9006 St. Gallen, Switzerland
| | - Timo Kayser
- Department of General-, Visceral-, Thoracic-, Transplant- and Pediatric Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
| | - Ulf Lorenzen
- Department of Anesthesia and Intensive Care Medicine, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
| | - Matthias Grünewald
- Department of Anesthesia and Intensive Care Medicine, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
- Department of Anesthesia and Intensive Care Medicine, Ev. Amalie Sieveking Hospital, Haselkamp 33, 22359 Hamburg, Germany
| | - Marit Kayser
- Department of General-, Visceral-, Thoracic-, Transplant- and Pediatric Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
| | - Anna Saltner
- Department of General-, Visceral-, Thoracic-, Transplant- and Pediatric Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
| | - Lidya-Olgu Durmaz
- Department of General-, Visceral-, Thoracic-, Transplant- and Pediatric Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
| | - Lina Johanna Reese
- Department of General-, Visceral-, Thoracic-, Transplant- and Pediatric Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
| | - Ewan Brownlee
- Department of Paediatric Surgery and Urology, Southampton Children's Hospital, University Hospital Southampton, Southampton SO16 6YD, UK
| | - Katja Reischig
- Department of General-, Visceral-, Thoracic-, Transplant- and Pediatric Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
- Kurt-Semm-Center for Minimally Invasive and Robotic Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
| | - Jonas Baastrup
- Department of General-, Visceral-, Thoracic-, Transplant- and Pediatric Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
- Kurt-Semm-Center for Minimally Invasive and Robotic Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
| | - Andreas Meinzer
- Department of General-, Visceral-, Thoracic-, Transplant- and Pediatric Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
- Kurt-Semm-Center for Minimally Invasive and Robotic Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
| | - Almut Kalz
- Kurt-Semm-Center for Minimally Invasive and Robotic Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
| | - Thomas Becker
- Department of General-, Visceral-, Thoracic-, Transplant- and Pediatric Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
- Kurt-Semm-Center for Minimally Invasive and Robotic Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
| | - Robert Bergholz
- Department of General-, Visceral-, Thoracic-, Transplant- and Pediatric Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
- Kurt-Semm-Center for Minimally Invasive and Robotic Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
| |
Collapse
|
9
|
Abstract
Abstract
Because of the increasing use of laparoscopic surgeries, robotic technologies have been developed to overcome the challenges these surgeries impose on surgeons. This paper presents an overview of the current state of surgical robots used in laparoscopic surgeries. Four main categories were discussed: handheld laparoscopic devices, laparoscope positioning robots, master–slave teleoperated systems with dedicated consoles, and robotic training systems. A generalized control block diagram is developed to demonstrate the general control scheme for each category of surgical robots. In order to review these robotic technologies, related published works were investigated and discussed. Detailed discussions and comparison tables are presented to compare their effectiveness in laparoscopic surgeries. Each of these technologies has proved to be beneficial in laparoscopic surgeries.
Collapse
|
10
|
Sassani JC, Clark SG, McGough CE, Shepherd JP, Bonidie M. Sacrocolpopexy experience with a novel robotic surgical platform. Int Urogynecol J 2022; 33:3255-3260. [PMID: 35312804 DOI: 10.1007/s00192-022-05155-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Accepted: 02/20/2022] [Indexed: 12/01/2022]
Abstract
INTRODUCTION AND HYPOTHESIS The objective was to describe early experience performing sacrocolpopexy using a novel robotic surgical platform. METHODS This is a case series of all women who underwent robotic-assisted sacrocolpopexy using a new robotics platform (TransEnterix Senhance) between January 2019 and July 2021. All sacrocolpopexies were performed by a single Female Pelvic Medicine and Reconstructive surgeon at a large academic institution. Perioperative information including complications was abstracted from the medical record. Anatomical recurrence was defined as any anatomical point at or past the hymen (≥0). Data are descriptive, with Mann-Whitney U test used for comparison of operative time between the first and second half of the patients. RESULTS A total of 25 sacrocolpopexies were performed using the new robotics platform. Mean age was 62.3 years (±9.2) and mean BMI was 26.5 (±3.8). Ten (40.0%) patients had a prior hysterectomy. Most (n = 21, 84.0%) had stage III or IV prolapse preoperatively. Mean operative time was 210.2 min (±48.6) and median estimated blood loss was 35 ml (IQR 25-50). Mean operative time decreased between the first and second half of the patients (231.7 min vs 190.3 min, p = 0.047). There were no major intraoperative complications. Median follow-up time was 16 weeks (IQR 4-34) and there were no subjective recurrences or retreatments during this period. Two patients (8.0%) had anatomical recurrence without subjective bother. There were two postoperative readmissions (8.0%) within 30 days for small bowel obstruction, one treated surgically and the other with nonsurgical management. CONCLUSIONS Our case series demonstrates feasibility and successful early adoption of a new robotics platform for robotic sacrocolpopexy.
Collapse
Affiliation(s)
- Jessica C Sassani
- Division of Urogynecology, Department of Obstetrics, Gynecology & Reproductive Sciences, University of Pittsburgh Medical Center, Pittsburgh, PA, USA.
| | - Stephanie Glass Clark
- Division of Urogynecology, Department of Obstetrics, Gynecology & Reproductive Sciences, University of Pittsburgh Medical Center, Pittsburgh, PA, USA
| | - Christine E McGough
- Department of Obstetrics, Gynecology & Reproductive Sciences, University of Pittsburgh Medical Center, Pittsburgh, PA, USA
| | - Jonathan P Shepherd
- Department of Obstetrics & Gynecology, University of Connecticut Health Center, Farmington, CT, USA
| | - Michael Bonidie
- Division of Urogynecology, Department of Obstetrics, Gynecology & Reproductive Sciences, University of Pittsburgh Medical Center, Pittsburgh, PA, USA
| |
Collapse
|
11
|
Abstract
Among the various robotic devices that exist for urologic surgery, the most common are synergistic telemanipulator systems. Several have achieved clinical feasibility and have been licensed for use in humans: the standard da Vinci, Avatera, Hinotori, Revo-i, Senhance, Versius, and Surgenius. Handheld and hands-on synergistic systems are also clinically relevant for use in urologic surgeries, including minimally invasive and endoscopic approaches. Future trends of robotic innovation include an exploration of more robust haptic systems that offer kinesthetic and tactile feedback; miniaturization and microrobotics; enhanced visual feedback with greater magnification and higher fidelity detail; and autonomous robots.
Collapse
|
12
|
Han ES, Advincula AP. Robotic Surgery: Advancements and Inflection Points in the Field of Gynecology. Obstet Gynecol Clin North Am 2021; 48:759-776. [PMID: 34756295 DOI: 10.1016/j.ogc.2021.07.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Robotics has become an essential part of the surgical armamentarium for a growing number of surgeons around the world. New companies seek to compete with established robotic systems that have dominated the market to date. Evolving robotic surgery platforms have introduced technologic and design advancements to optimize ergonomics, improve visualization, provide haptic feedback, and make systems smaller and cheaper. With the introduction of any new technology in the operating room, it is imperative that safeguards be in place to ensure its appropriate use. Current processes for granting of hospital robotic surgery privileges are inadequate and must be strengthened and standardized.
Collapse
Affiliation(s)
- Esther S Han
- Columbia University Irving Medical Center, 622 West 168th Street, PH16-139, New York, NY 10032, USA
| | - Arnold P Advincula
- Columbia University Irving Medical Center, 622 West 168th Street, PH16-139, New York, NY 10032, USA.
| |
Collapse
|
13
|
Farinha R, Puliatti S, Mazzone E, Amato M, Rosiello G, Yadav S, De Groote R, Piazza P, Bravi CA, Koukourikis P, Rha KH, Cacciamani G, Micali S, Wiklund P, Rocco B, Mottrie A. Potential Contenders for the Leadership in Robotic Surgery. J Endourol 2021; 36:317-326. [PMID: 34579555 DOI: 10.1089/end.2021.0321] [Citation(s) in RCA: 51] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
Purpose: To summarize the scientific published literature on new robotic surgical platforms with potential use in the urological field, reviewing their evolution from presentation until the present day. Our goal is to describe the current characteristics and possible prospects for these platforms. Materials and Methods: A nonsystematic search of the PubMed, Cochrane library's Central, EMBASE, MEDLINE, and Scopus databases was conducted to identify scientific literature about new robotic platforms other than the Da Vinci® system, reviewing their evolution from inception until December 2020. Only English language publications were included. The following keywords were used: "new robotic platforms," "Revo-I robot," "Versius robot," and "Senhance robot." All relevant English-language original studies were analyzed by one author (R.F.) and summarized after discussion with an independent third party (E.M., S.Y., S.P., and M.A.). Results: Since 1995, Intuitive Surgical, Inc., with the Da Vinci surgical system, is the leading company in the robotic surgical market. However, Revo-I®, Versius®, and Senhance® are the other three platforms that recently appeared on the market with available articles published in peer-reviewed journals. Among these three new surgical systems, the Senhance robot has the most substantial scientific proof of its capacity to perform minimally invasive urological surgery and as such, it might become a contender of the Da Vinci robot. Conclusions: The Da Vinci surgical platform has allowed the diffusion of robotic surgery worldwide and showed the different advantages of this type of technique. However, its use has some drawbacks, especially its price. New robotic platforms characterized by unique features are under development. Of note, they might be less expensive compared with the Da Vinci robotic system. We found that these new platforms are still at the beginning of their technical and scientific validation. However, the Senhance robot is in a more advanced stage, with clinical studies supporting its full implementation.
Collapse
Affiliation(s)
- Rui Farinha
- ORSI Academy, Melle, Belgium.,Department of Urology, OLV, Aalst, Belgium.,Urology Department, Centro Hospitalar Universitário de Lisboa Central, Lisbon, Portugal.,Urology Department, Lusíadas Hospital, Lisbon, Portugal
| | - Stefano Puliatti
- ORSI Academy, Melle, Belgium.,Department of Urology, OLV, Aalst, Belgium.,Department of Urology, University of Modena and Reggio Emilia, Modena, Italy
| | - Elio Mazzone
- Unit of Urology, Division of Oncology, URI, IRCCS Ospedale San Raffaele, Milan, Italy.,Department of Urology, Vita-Salute San Raffaele University, Milan, Italy
| | - Marco Amato
- ORSI Academy, Melle, Belgium.,Department of Urology, OLV, Aalst, Belgium.,Department of Urology, University of Modena and Reggio Emilia, Modena, Italy
| | - Giuseppe Rosiello
- Unit of Urology, Division of Oncology, URI, IRCCS Ospedale San Raffaele, Milan, Italy.,Department of Urology, Vita-Salute San Raffaele University, Milan, Italy
| | - Siddharth Yadav
- Department of Urology & Renal Transplant, Vardhman Mahavir Medical College and Safdarjung Hospital, New Delhi, India
| | - Ruben De Groote
- ORSI Academy, Melle, Belgium.,Department of Urology, OLV, Aalst, Belgium
| | - Pietro Piazza
- ORSI Academy, Melle, Belgium.,Department of Urology, OLV, Aalst, Belgium.,Division of Urology, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy
| | - Carlo Andrea Bravi
- ORSI Academy, Melle, Belgium.,Department of Urology, OLV, Aalst, Belgium.,Unit of Urology, Division of Oncology, URI, IRCCS Ospedale San Raffaele, Milan, Italy.,Department of Urology, Vita-Salute San Raffaele University, Milan, Italy
| | - Periklis Koukourikis
- Department of Urology and Urological Science Institute, Yonsei University College of Medicine, Seoul, Korea.,Second Department of Urology, Medical School, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Koon Ho Rha
- Department of Urology and Urological Science Institute, Yonsei University College of Medicine, Seoul, Korea
| | - Giovanni Cacciamani
- USC Institute of Urology and Catherine and Joseph Aresty Department of Urology, University of Southern California, Los Angeles, California, USA
| | - Salvatore Micali
- Department of Urology, University of Modena and Reggio Emilia, Modena, Italy
| | - Peter Wiklund
- Department of Urology, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Bernardo Rocco
- Department of Urology, University of Modena and Reggio Emilia, Modena, Italy
| | - Alexandre Mottrie
- ORSI Academy, Melle, Belgium.,Department of Urology, OLV, Aalst, Belgium
| |
Collapse
|
14
|
Krebs TF, Egberts JH, Lorenzen U, Krause MF, Reischig K, Meiksans R, Baastrup J, Meinzer A, Alkatout I, Cohrs G, Wieker H, Lüthje A, Vieten S, Schultheiss G, Bergholz R. Robotic infant surgery with 3 mm instruments: a study in piglets of less than 10 kg body weight. J Robot Surg 2021; 16:215-228. [PMID: 33772434 PMCID: PMC8863694 DOI: 10.1007/s11701-021-01229-0] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2021] [Accepted: 03/16/2021] [Indexed: 11/29/2022]
Abstract
No data exist concerning the appication of a new robotic system with 3 mm instruments (Senhance®, Transenterix) in infants and small children. Therefore, the aim of this study was to test the system for its feasibility, performance and safety of robotic pediatric abdominal and thoracic surgery in piglets simulating infants with a body weight lower than 10 kg. 34 procedures (from explorative laparoscopy to thoracoscopic esophageal repair) were performed in 12 piglets with a median age of 23 (interquartile range: 12–28) days and a median body weight of 6.9 (6.1–7.3) kg. The Senhance® robotic system was used with 3 mm instruments, a 10 mm 3D 0° or 30° videoscope and advanced energy devices, the setup consisted of the master console and three separate arms. The amount, size, and position of the applied ports, their distance as well as the distance between the three operator arms of the robot, external and internal collisions, and complications of the procedures were recorded and analyzed. We were able to perform all planned surgical procedures with 3 mm robotic instruments in piglets with a median body weight of less than 7 kg. We encountered two non-robot associated complications (bleeding from the inferior caval and hepatic vein) which led to termination of the live procedures. Technical limitations were the reaction time and speed of robotic camera movement with eye tracking, the excessive bending of the 3 mm instruments and intermittent need of re-calibration of the fulcrum point. Robotic newborn and infant surgery appears technically feasible with the Senhance® system. Software adjustments for camera movement and sensitivity of the fulcrum point calibration algorithm to adjust for the increased compliance of the abdominal wall of infants, therefore reducing the bending of the instruments, need to be implemented by the manufacturer as a result of our study. To further evaluate the Senhance® system, prospective trials comparing it to open, laparoscopic and other robotic systems are needed.
Collapse
Affiliation(s)
- Thomas F Krebs
- Department of General-, Visceral-, Thoracic-, Transplant- and Pediatric Surgery, Faculty of Medicine, Christian-Albrechts-University of Kiel, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105, Kiel, Germany.,Department of Pediatric Surgery, Children's Hospital of East Switzerland, Claudiusstrasse 6, 9006, St. Gallen, Switzerland
| | - Jan-Hendrik Egberts
- Department of General-, Visceral-, Thoracic-, Transplant- and Pediatric Surgery, Faculty of Medicine, Christian-Albrechts-University of Kiel, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105, Kiel, Germany
| | - Ulf Lorenzen
- Department of Anesthesia and Intensive Care Medicine, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105, Kiel, Germany
| | - Martin F Krause
- Department of Pediatrics I and Pediatric Intensive Care Medicine, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105, Kiel, Germany
| | - Katja Reischig
- Department of General-, Visceral-, Thoracic-, Transplant- and Pediatric Surgery, Faculty of Medicine, Christian-Albrechts-University of Kiel, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105, Kiel, Germany
| | - Roberts Meiksans
- Department of General-, Visceral-, Thoracic-, Transplant- and Pediatric Surgery, Faculty of Medicine, Christian-Albrechts-University of Kiel, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105, Kiel, Germany
| | - Jonas Baastrup
- Department of General-, Visceral-, Thoracic-, Transplant- and Pediatric Surgery, Faculty of Medicine, Christian-Albrechts-University of Kiel, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105, Kiel, Germany
| | - Andreas Meinzer
- Department of General-, Visceral-, Thoracic-, Transplant- and Pediatric Surgery, Faculty of Medicine, Christian-Albrechts-University of Kiel, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105, Kiel, Germany
| | - Ibrahim Alkatout
- Department of Obstetrics and Gynecology, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105, Kiel, Germany
| | - Gesa Cohrs
- Department of Neurosurgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105, Kiel, Germany
| | - Henning Wieker
- Department of Cranio-Maxillo-Facial Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105, Kiel, Germany
| | - Annette Lüthje
- Department of Animal Welfare, CAU Kiel, Olshausenstr. 40, 24098, Kiel, Germany
| | - Sarah Vieten
- Department of Animal Welfare, CAU Kiel, Olshausenstr. 40, 24098, Kiel, Germany
| | - Gerhard Schultheiss
- Department of Animal Welfare, CAU Kiel, Olshausenstr. 40, 24098, Kiel, Germany
| | - Robert Bergholz
- Department of General-, Visceral-, Thoracic-, Transplant- and Pediatric Surgery, Faculty of Medicine, Christian-Albrechts-University of Kiel, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105, Kiel, Germany.
| |
Collapse
|
15
|
Medical student experience with robot-assisted surgery after limited laparoscopy exposure. J Robot Surg 2020; 15:443-450. [PMID: 32705574 PMCID: PMC8134305 DOI: 10.1007/s11701-020-01129-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Accepted: 07/16/2020] [Indexed: 11/04/2022]
Abstract
The purpose of the study was to evaluate the objective and subjective experience of medical students completing robotic surgery tasks after limited laparoscopy exposure. Twenty-three medical students without previous laparoscopy and robotic surgery experience self-enrolled into 0 min (n = 11), 20 min (n = 6), and 40 min (n = 6) laparoscopy training groups. Subjects completed rope passing and ball placement tasks on a laparoscopy trainer before repeating similar tasks on the Senhance Surgical System, a robot-assisted digital laparoscopy device. Videos were recorded to evaluate objective measures including time, completion rate, clutch use, out of view instruments, ball drops, and manual adjustments. The NASA-TLX survey was administered to assess subjective experience using workload and task demand measures. There were no statistically significant differences in objective performance between the groups (p > 0.05). Subjects who completed laparoscopy training reported higher workloads, but these differences were not statistically significant (p > 0.05). NASA-TLX workload was correlated with time performance on Pearson and Spearman tests (r = 0.623, rho = 0.681, p < 0.01). Initial experience of medical students with robot-assisted surgery did not differ significantly after limited laparoscopy exposure.
Collapse
|
16
|
Kaštelan Ž, Knežević N, Hudolin T, Kuliš T, Penezić L, Goluža E, Gidaro S, Ćorušić A. Extraperitoneal radical prostatectomy with the Senhance Surgical System robotic platform. Croat Med J 2020. [PMID: 31894922 PMCID: PMC6952894 DOI: 10.3325/cmj.2019.60.556] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Affiliation(s)
| | | | | | - Tomislav Kuliš
- Tomislav Kuliš, Department of Urology, University Hospital Centre Zagreb, Zagreb, Croatia,
| | | | | | | | | |
Collapse
|
17
|
Abstract
Just as laparoscopic surgery provided a giant leap in safety and recovery for patients over open surgery methods, robotic-assisted surgery (RAS) is doing the same to laparoscopic surgery. The first laparoscopic-RAS systems to be commercialized were the Intuitive Surgical, Inc. (Sunnyvale, CA, USA) da Vinci and the Computer Motion Zeus. These systems were similar in many aspects, which led to a patent dispute between the two companies. Before the dispute was settled in court, Intuitive Surgical bought Computer Motion, and thus owned critical patents for laparoscopic-RAS. Recently, the patents held by Intuitive Surgical have begun to expire, leading to many new laparoscopic-RAS systems being developed and entering the market. In this study, we review the newly commercialized and prototype laparoscopic-RAS systems. We compare the features of the imaging and display technology, surgeons console and patient cart of the reviewed RAS systems. We also briefly discuss the future directions of laparoscopic-RAS surgery. With new laparoscopic-RAS systems now commercially available we should see RAS being adopted more widely in surgical interventions and costs of procedures using RAS to decrease in the near future.
Collapse
|
18
|
Son K, Lee KB. Prediction of learning curves of 2 dental CAD software programs, part 2: Differences in learning effects by type of dental personnel. J Prosthet Dent 2019; 123:747-752. [PMID: 31590976 DOI: 10.1016/j.prosdent.2019.05.026] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2019] [Revised: 05/23/2019] [Accepted: 05/23/2019] [Indexed: 01/28/2023]
Abstract
STATEMENT OF PROBLEM Dental computer-aided design (CAD) software programs are essential elements of the digital workflow. Therefore, it is necessary to study the learning effect of dental CAD software programs for efficient use. PURPOSE The purpose of this in vitro study was to predict the learning curve of dental CAD software programs according to dental personnel by using the Wright model and to investigate the tendency of dental personnel to reduce working time according to repeated learning. MATERIAL AND METHODS A total of 36 participants were recruited, including an equal number of dentists, dental technicians, and dental students (12 each). A custom abutment design was evaluated by using exocad CAD and Deltanine CAD software programs. The design was carried out in the following order: 4 steps repeated 3 times each. This study applied the formula of the Wright model to predict 500 repetitive times. In the statistical analysis, 3-repetition and 500-repetition times were analyzed with the Kruskal-Wallis H test and Friedman test (α=.05), and a post hoc comparison was performed by using the Mann-Whitney U-test and Bonferroni correction method (α=.017). RESULTS Three repetitions resulted in shorter working time in the dental technician group. The 3-repetition time decreased statistically for all dental personnel (P<.001). The time for 500 repetitions showed a statistically significant difference according to the type of dental personnel (P=.036), but no significant difference was found after the fourth iteration (fifth iteration: P=.076). Furthermore, the estimated time of 500 iterations decreased statistically significantly from the first to the 500th iteration (P<.001). CONCLUSIONS All dental personnel showed learning effects of dental CAD software programs. Although the dental technician group initially showed less working time, after initial learning, the same learning effect appeared, regardless of the type of dental personnel.
Collapse
Affiliation(s)
- KeunBaDa Son
- Graduate student, Department of Dental Science, Graduate School, Kyungpook National University, Daegu, Republic of Korea
| | - Kyu-Bok Lee
- Professor, Department of Prosthodontics, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea.
| |
Collapse
|
19
|
Samalavicius NE, Janusonis V, Siaulys R, Jasėnas M, Deduchovas O, Venckus R, Ezerskiene V, Paskeviciute R, Klimaviciute G. Robotic surgery using Senhance ® robotic platform: single center experience with first 100 cases. J Robot Surg 2019; 14:371-376. [PMID: 31301021 DOI: 10.1007/s11701-019-01000-6] [Citation(s) in RCA: 64] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2019] [Accepted: 07/08/2019] [Indexed: 01/04/2023]
Abstract
Until recently, robotic surgery has been associated only with the da Vinci robotic system. A novel Senhance® robotic system (TransEnterix Surgical Inc., Morrisville, NC, USA) was introduced almost 5 years ago. Published reports on experience using this robotic platform are very limited. We present a prospective analysis of the first 100 robotic surgeries in abdominal surgery, gynecology, and urology in Klaipeda University Hospital, Klaipeda, Lithuania. Out of 100 operated patients during the mentioned period, 49 were female and 51 men, age range 27-79 years, on an average 55 years. 39 underwent robotic abdominal surgical procedures, 31-urological, and 30 gynecological surgeries. Duration of surgery varied from 30 min to 6 h and 5 min, on an average 2 h 25 min. Almost half 49 (49%) were operated on for malignant diseases: prostate cancer-27, renal cell carcinoma-1, endometrial cancer-7, ovarian cancer-1, colorectal cancer-13 (7 colon and 6 rectum). In-hospital stay was on an average 4 days, range 1-15 days. There were 3 (3%) conversions: two to laparoscopy (both undergoing robotic radical prostatectomy) and one to open (undergoing total hysterectomy). 6 (6%) complications occurred during 30 postoperative days, 2 demanding surgery. According to the Clavien-Dido classification, they were grade II in 3, grade III a in 1 and grade III b in 2 cases. There was no mortality in this patient population. Our experience with different types of robotic surgeries allows us to state that the Senhance® robotic system is feasible and safe in general surgery, gynecology, and urology, and wider implementation of this system worldwide is simply a question of time.
Collapse
Affiliation(s)
- Narimantas Evaldas Samalavicius
- Department of Surgery, Klaipeda University Hospital, 41 Liepojos Str., 92288, Klaipeda, Lithuania.
- Clinic of Internal, Family Medicine and Oncology, Faculty of Medicine, Vilnius University, 2 Santariskiu Str., 08660, Vilnius, Lithuania.
| | - Vinsas Janusonis
- Department of Surgery, Klaipeda University Hospital, 41 Liepojos Str., 92288, Klaipeda, Lithuania
- Faculty of Health Sciences, Klaipeda University, 84 H. Manto Str., 92294, Klaipeda, Lithuania
| | - Raimondas Siaulys
- Department of Surgery, Klaipeda University Hospital, 41 Liepojos Str., 92288, Klaipeda, Lithuania
| | - Marius Jasėnas
- Department of Surgery, Klaipeda University Hospital, 41 Liepojos Str., 92288, Klaipeda, Lithuania
| | - Olegas Deduchovas
- Department of Surgery, Klaipeda University Hospital, 41 Liepojos Str., 92288, Klaipeda, Lithuania
| | - Raimondas Venckus
- Department of Surgery, Klaipeda University Hospital, 41 Liepojos Str., 92288, Klaipeda, Lithuania
| | - Viktorija Ezerskiene
- Department of Surgery, Klaipeda University Hospital, 41 Liepojos Str., 92288, Klaipeda, Lithuania
| | - Renata Paskeviciute
- Department of Surgery, Klaipeda University Hospital, 41 Liepojos Str., 92288, Klaipeda, Lithuania
| | - Geda Klimaviciute
- Department of Surgery, Klaipeda University Hospital, 41 Liepojos Str., 92288, Klaipeda, Lithuania
| |
Collapse
|
20
|
Bergholz R, Botden S, Verweij J, Tytgat S, Van Gemert W, Boettcher M, Ehlert H, Reinshagen K, Gidaro S. Evaluation of a new robotic-assisted laparoscopic surgical system for procedures in small cavities. J Robot Surg 2019; 14:191-197. [PMID: 30993523 DOI: 10.1007/s11701-019-00961-y] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2019] [Accepted: 04/09/2019] [Indexed: 12/13/2022]
Abstract
No data exists concerning the application of a new robotic system with 3-mm instruments (Senhance™, Transenterix, Milano, Italy) in small cavities. Therefore, the aim of this study was to test the system for its performance of intracorporal suturing in small boxes simulating small body cavities. Translucent plastic boxes of decreasing volumes (2519-90 ml) were used. The procedures (two single stitches, each with two consecutive surgical square knots) were performed by a system-experienced and three system-inexperienced surgeons in each box, starting within the largest box, consecutively exchanging the boxes into smaller ones. With this approach, the total amount of procedures performed by each surgeon increased with decreasing volume of boxes being operated in. Outcomes included port placement, time, task completion, internal and external instrument/instrument collisions and instrument/box collisions. The procedures could be performed in all boxes. The operating time decreased gradually in the first three boxes (2519-853 ml), demonstrating a learning curve. The increase of operating time from boxes of 599 ml and lower may be attributed to the increased complexity of the procedure in small cavities as in the smallest box with the dimensions of 2.9 × 6.3 × 4.9 cm. This is also reflected by the parallel increase of internal instrument-instrument collisions. With the introduction of 3-mm instruments in a new robotic surgical system, we were able to perform intracorporal suturing and knot tying in cavities as small as 90 ml. Whether this system is comparable to conventional three-port 3-mm laparoscopic surgery in small cavities-such as in pediatric surgery-has to be evaluated in further studies.
Collapse
Affiliation(s)
- Robert Bergholz
- Department of Pediatric Surgery, UKE Children's Hospital, University Medical Center Hamburg-Eppendorf (UKE), Campus Ost 45, Room: 01.5.050.1, Martinistrasse 52, Postbox 37, 20246, Hamburg, Germany.
| | - Sanne Botden
- Department of Pediatric Surgery, Radboudumc-Amalia Children's Hospital, Nijmegen, The Netherlands
| | - Johannes Verweij
- Department of Pediatric Surgery, Wilhemina Children's Hospital, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Stefaan Tytgat
- Department of Pediatric Surgery, Wilhemina Children's Hospital, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Wim Van Gemert
- Department of Pediatric Surgery, University Medical Center Maastricht, University of Maastricht, P. Debyelaan 25, 6229HX, Maastricht, The Netherlands
| | - Michael Boettcher
- Department of Pediatric Surgery, UKE Children's Hospital, University Medical Center Hamburg-Eppendorf (UKE), Campus Ost 45, Room: 01.5.050.1, Martinistrasse 52, Postbox 37, 20246, Hamburg, Germany
| | - Heiko Ehlert
- Central OR Management for General and Hepatobiliary Surgery, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany
| | - Konrad Reinshagen
- Department of Pediatric Surgery, UKE Children's Hospital, University Medical Center Hamburg-Eppendorf (UKE), Campus Ost 45, Room: 01.5.050.1, Martinistrasse 52, Postbox 37, 20246, Hamburg, Germany
| | - Stefano Gidaro
- Department of Medical, Oral and Biotechnological Sciences, University G. D'Annunzio, Chieti-Pescara, Italy
| |
Collapse
|
21
|
Rumolo V, Rosati A, Tropea A, Biondi A, Scambia G. Senhance robotic platform for gynecologic surgery: a review of literature. Updates Surg 2019; 71:419-427. [PMID: 30659479 DOI: 10.1007/s13304-018-00620-1] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2018] [Accepted: 12/29/2018] [Indexed: 12/27/2022]
Abstract
The advantages of endoscopic procedures are well demonstrated in various surgical procedures. In this field, the technological improvement has been significant. One of the most relevant was made by the introduction of robotic surgery that, thanks to the instruments articulation and the precision of movement, made possible to perform even the most complex procedures. The terms "Alf-X" OR "Senhance" OR "robot" OR "robotic" were systematically used to search the PubMed and Scopus databases. The principal findings considered in the present review were: the study design, the number of patients included in each study, operative time, estimated blood loss (EBL), conversion rate to standard laparoscopy (SLPS) or laparotomy (LPT), post-operative complications, post-operative hospital stay, and the possible advantages and disadvantages reported by the authors of the studies. A total of eight studies were considered eligible for the present review. The average operative time for TH reported was 110-140 min. In two case-control studies, the operative time was significantly prolonged (P < 0.05) for robotic procedures when compared with SLPS. The EBL was ≤ 100 ml in all studies. Whereas no statistically significant differences were shown in the two case-control studies in terms of conversion to LPT, all studies were in accordance with the post-operative hospital stay, reporting an average of 2 days for total hysterectomy and 1 day for adnexal surgery.
Collapse
Affiliation(s)
- Valerio Rumolo
- Unità Operativa Ginecologia Oncologica, Dipartimento Scienze della Salute della Donna e del Bambino, Fondazione Policlinico Universitario A. Gemelli, IRCCS, L.go Agostino Gemelli 8, Rome, Italy.
| | - Andrea Rosati
- Unità Operativa Ginecologia Oncologica, Dipartimento Scienze della Salute della Donna e del Bambino, Fondazione Policlinico Universitario A. Gemelli, IRCCS, L.go Agostino Gemelli 8, Rome, Italy
| | - Alessandro Tropea
- Department for the Treatment and Study of Abdominal Diseases and Abdominal Transplantation, IRCCS-ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad alta specializzazione), University of Pittsburgh Medical Center Italy, Palermo, Italy
| | - Antonio Biondi
- Department of General Surgery and Medical Surgical Specialties, University of Catania, Catania, Italy
| | - Giovanni Scambia
- Unità Operativa Ginecologia Oncologica, Dipartimento Scienze della Salute della Donna e del Bambino, Fondazione Policlinico Universitario A. Gemelli, IRCCS, L.go Agostino Gemelli 8, Rome, Italy
| |
Collapse
|