1
|
Sabucedo-Villamarin B, Garcia-Queiruga J, Pena-Verdeal H, Garcia-Resua C, Yebra-Pimentel E, Giraldez MJ. Diagnostic Cut-Off Values Based on Lipid Layer Pattern for Dry Eye Disease Subtypes Assessment. J Clin Med 2025; 14:623. [PMID: 39860629 PMCID: PMC11765754 DOI: 10.3390/jcm14020623] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2024] [Revised: 12/12/2024] [Accepted: 01/17/2025] [Indexed: 01/27/2025] Open
Abstract
Background: The aim of the present study was to establish a cut-off value of the Lipid Layer Pattern (LLP) between participants with different subtypes of Dry Eye Disease (DED) including Deficient Dry Eye (ADDE), Evaporative Dry Eye (EDE), and Mixed Dry Eye (MDE). Methods: 240 participants diagnosed with DED according to the Tear Film and Ocular Surface Society in the Dry Eye Workshop II guidelines were included in the study. Tear Meniscus Height (TMH) using the Tearscope illumination and Meibomian Gland Loss Area (MGLA) using the Keratograph 5M were assessed to categorize the participants into an ADDE group, EDE group, or MDE group. Then, the LLP was assessed using the Tearscope following the Guillon (LLP-G) and Colour (LLP-C) schemes. Results: Receiver Operating Characteristics (ROC) showed that both LLP-G and LLP-C have no diagnostic potential in distinguishing between ADDE and EDE participants (both p ≥ 0.724). However, to differentiate the ADDE participants from the MDE, ROC procedures showed a good diagnostic potential with cut-off values of Closed Meshwork-Wave (AUC ± SD = 0.609 ± 0.049, p = 0.038, sensitivity: 23.9%; specificity: 76.1%) and Grey-White (AUC ± SD = 0.611 ± 0.050, p = 0.034, sensitivity: 40.7%; specificity: 73.9%) for LLP-G and LLP-C, respectively. Also, a significant potential to distinguish between the EDE from MDE participants was found, with cut-off values of Closed Meshwork (AUC ± SD = 0.604 ± 0.049, p = 0.043, sensitivity: 40.8%; specificity: 76.1%) and Grey-White (AUC ± SD = 0.604 ± 0.051, p = 0.038, sensitivity: 44.7%; specificity: 73.9%) for LLP-G and LLP-C, respectively. Conclusions: Using the Tearscope, both LLP-G and LLP-C has diagnostic potential to distinguish MDE participants from the other subtypes of DED.
Collapse
Affiliation(s)
- Belen Sabucedo-Villamarin
- GI-2092-Optometry, Departamento de Física Aplicada (Área de Optometría), Universidade de Santiago de Compostela, Campus Vida s/n, 15701 Santiago de Compostela, Spain; (J.G.-Q.); (C.G.-R.); (E.Y.-P.); (M.J.G.)
| | - Jacobo Garcia-Queiruga
- GI-2092-Optometry, Departamento de Física Aplicada (Área de Optometría), Universidade de Santiago de Compostela, Campus Vida s/n, 15701 Santiago de Compostela, Spain; (J.G.-Q.); (C.G.-R.); (E.Y.-P.); (M.J.G.)
- Instituto de Investigación Sanitaria (IDIS), Travesía da Choupana S/N, 15701 Santiago de Compostela, Spain
| | - Hugo Pena-Verdeal
- GI-2092-Optometry, Departamento de Física Aplicada (Área de Optometría), Universidade de Santiago de Compostela, Campus Vida s/n, 15701 Santiago de Compostela, Spain; (J.G.-Q.); (C.G.-R.); (E.Y.-P.); (M.J.G.)
- Instituto de Investigación Sanitaria (IDIS), Travesía da Choupana S/N, 15701 Santiago de Compostela, Spain
| | - Carlos Garcia-Resua
- GI-2092-Optometry, Departamento de Física Aplicada (Área de Optometría), Universidade de Santiago de Compostela, Campus Vida s/n, 15701 Santiago de Compostela, Spain; (J.G.-Q.); (C.G.-R.); (E.Y.-P.); (M.J.G.)
- Instituto de Investigación Sanitaria (IDIS), Travesía da Choupana S/N, 15701 Santiago de Compostela, Spain
| | - Eva Yebra-Pimentel
- GI-2092-Optometry, Departamento de Física Aplicada (Área de Optometría), Universidade de Santiago de Compostela, Campus Vida s/n, 15701 Santiago de Compostela, Spain; (J.G.-Q.); (C.G.-R.); (E.Y.-P.); (M.J.G.)
- Instituto de Investigación Sanitaria (IDIS), Travesía da Choupana S/N, 15701 Santiago de Compostela, Spain
| | - Maria J. Giraldez
- GI-2092-Optometry, Departamento de Física Aplicada (Área de Optometría), Universidade de Santiago de Compostela, Campus Vida s/n, 15701 Santiago de Compostela, Spain; (J.G.-Q.); (C.G.-R.); (E.Y.-P.); (M.J.G.)
- Instituto de Investigación Sanitaria (IDIS), Travesía da Choupana S/N, 15701 Santiago de Compostela, Spain
| |
Collapse
|
2
|
Garcia-Queiruga J, Pena-Verdeal H, Sabucedo-Villamarin B, Garcia-Resua C, Giraldez MJ, Yebra-Pimentel E. Temporal Progression of Entry Factors into the Vicious Circle of Dry Eye in Untreated Sufferers. Life (Basel) 2024; 14:806. [PMID: 39063561 PMCID: PMC11278086 DOI: 10.3390/life14070806] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2024] [Revised: 06/12/2024] [Accepted: 06/21/2024] [Indexed: 07/28/2024] Open
Abstract
BACKGROUND Dry eye disease (DED) is characterized by the loss of ocular surface homeostasis with specific signs and symptoms. Studying the progression of a multifactorial disease is exceedingly challenging for researchers because several factors can influence it. The present study aims to study changes in tear meniscus height (TMH), lipid layer pattern (LLP), and bulbar hyperemia over time in untreated DED participants. METHODS This retrospective longitudinal study included 73 participants (146 eyes) diagnosed with DED since at least 2013. Participants underwent new examinations between 2021 and 2023, grouped by 8-, 6-, or 4-year follow-up periods. TMH, LLP, and bulbar hyperemia were assessed in both examinations. No participant received pharmacological treatment for DED. RESULTS Differences in TMH, bulbar hyperemia, and LLP between sessions were obtained in the 8-year group (p ≤ 0.027). Differences in bulbar hyperemia and LLP between sessions were obtained in the 6-year group (p ≤ 0.022). The only differences in LLP between sessions were obtained in the 4-year group (p < 0.005). CONCLUSION Changes in TMH were obtained after periods of eight years from the first eye examination. Also, changes in bulbar hyperemia were obtained at periods of 8 and 6 years; however, changes in LLP could be found from 4-year follow-ups.
Collapse
Affiliation(s)
- Jacobo Garcia-Queiruga
- GI-2092 Optometry, Departamento de Física Aplicada, Facultad de Óptica y Optometría, Universidade de Santiago de Compostela, Campus Vida s/n, 15701 Santiago de Compostela, Spain; (B.S.-V.); (C.G.-R.)
- AC-24 Optometry, Instituto de Investigación Sanitaria de Santiago de Compostela (IDIS), Travesía da Choupana, 15701 Santiago de Compostela, Spain
| | - Hugo Pena-Verdeal
- GI-2092 Optometry, Departamento de Física Aplicada, Facultad de Óptica y Optometría, Universidade de Santiago de Compostela, Campus Vida s/n, 15701 Santiago de Compostela, Spain; (B.S.-V.); (C.G.-R.)
- AC-24 Optometry, Instituto de Investigación Sanitaria de Santiago de Compostela (IDIS), Travesía da Choupana, 15701 Santiago de Compostela, Spain
| | - Belen Sabucedo-Villamarin
- GI-2092 Optometry, Departamento de Física Aplicada, Facultad de Óptica y Optometría, Universidade de Santiago de Compostela, Campus Vida s/n, 15701 Santiago de Compostela, Spain; (B.S.-V.); (C.G.-R.)
| | - Carlos Garcia-Resua
- GI-2092 Optometry, Departamento de Física Aplicada, Facultad de Óptica y Optometría, Universidade de Santiago de Compostela, Campus Vida s/n, 15701 Santiago de Compostela, Spain; (B.S.-V.); (C.G.-R.)
- AC-24 Optometry, Instituto de Investigación Sanitaria de Santiago de Compostela (IDIS), Travesía da Choupana, 15701 Santiago de Compostela, Spain
| | - Maria J. Giraldez
- GI-2092 Optometry, Departamento de Física Aplicada, Facultad de Óptica y Optometría, Universidade de Santiago de Compostela, Campus Vida s/n, 15701 Santiago de Compostela, Spain; (B.S.-V.); (C.G.-R.)
- AC-24 Optometry, Instituto de Investigación Sanitaria de Santiago de Compostela (IDIS), Travesía da Choupana, 15701 Santiago de Compostela, Spain
| | - Eva Yebra-Pimentel
- GI-2092 Optometry, Departamento de Física Aplicada, Facultad de Óptica y Optometría, Universidade de Santiago de Compostela, Campus Vida s/n, 15701 Santiago de Compostela, Spain; (B.S.-V.); (C.G.-R.)
- AC-24 Optometry, Instituto de Investigación Sanitaria de Santiago de Compostela (IDIS), Travesía da Choupana, 15701 Santiago de Compostela, Spain
| |
Collapse
|
3
|
Pena-Verdeal H, Garcia-Queiruga J, Sabucedo-Villamarin B, Garcia-Resua C, Giraldez MJ, Yebra-Pimentel E. A Comprehensive Study on Tear Meniscus Height Inter-Eye Differences in Aqueous Deficient Dry Eye Diagnosis. J Clin Med 2024; 13:659. [PMID: 38337353 PMCID: PMC10856492 DOI: 10.3390/jcm13030659] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2023] [Revised: 01/18/2024] [Accepted: 01/22/2024] [Indexed: 02/12/2024] Open
Abstract
(1) Background: Dry eye disease (DED) is a chronic ocular surface condition that requires precise diagnostic tools. The present study aimed to investigate the diagnostic potential of the absolute inter-eye difference (|OD-OS|) in tear meniscus height (TMH) for the detection of the presence of aqueous deficient dry eye (ADDE). (2) Methods: A sample of 260 participants with dry eye complaints underwent ocular surface examinations thorough diagnostic assessments based on the Tear Film and Ocular Surface Society guidelines (TFOS DEWS II). Participants were subsequently categorized as No ADDE and ADDE based on TMH. Statistical analyses to determine the optimal TMH|OD-OS| cut-off value in a randomly selected study group (200 participants) were performed, while a separate validation analysis of the cut-off value obtained in a random cross-validation group (60 participants) was also performed. (3) Results: The significant diagnostic capability of TMH|OD-OS| (area under the curve = 0.719 ± 0.036, p < 0.001) was found. The identified cut-off value of 0.033 mm demonstrated reliable specificity (77.6%) and moderate sensitivity (59.1%). Cross-validation confirmed the cut-off value's association with the TFOS DEWS II diagnostic criterion (Cramer's V = 0.354, p = 0.006). (4) Conclusions: The present study provides evidence for the diagnostic potential of TMH|OD-OS| in identifying ADDE. The identified cut-off value enhances the specificity and offers moderate sensitivity, providing an objective tool for clinical decision making.
Collapse
Affiliation(s)
- Hugo Pena-Verdeal
- GI-2092—Optometría, Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, Universidade de Santiago de Compostela, Campus Vida S/N, 15705 Santiago de Compostela, Spain; (B.S.-V.); (C.G.-R.); (M.J.G.); (E.Y.-P.)
- Instituto de Investigación Sanitaria (IDIS), Travesía da Choupana S/N, 15706 Santiago de Compostela, Spain
| | - Jacobo Garcia-Queiruga
- GI-2092—Optometría, Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, Universidade de Santiago de Compostela, Campus Vida S/N, 15705 Santiago de Compostela, Spain; (B.S.-V.); (C.G.-R.); (M.J.G.); (E.Y.-P.)
- Instituto de Investigación Sanitaria (IDIS), Travesía da Choupana S/N, 15706 Santiago de Compostela, Spain
| | - Belen Sabucedo-Villamarin
- GI-2092—Optometría, Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, Universidade de Santiago de Compostela, Campus Vida S/N, 15705 Santiago de Compostela, Spain; (B.S.-V.); (C.G.-R.); (M.J.G.); (E.Y.-P.)
| | - Carlos Garcia-Resua
- GI-2092—Optometría, Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, Universidade de Santiago de Compostela, Campus Vida S/N, 15705 Santiago de Compostela, Spain; (B.S.-V.); (C.G.-R.); (M.J.G.); (E.Y.-P.)
- Instituto de Investigación Sanitaria (IDIS), Travesía da Choupana S/N, 15706 Santiago de Compostela, Spain
| | - Maria J. Giraldez
- GI-2092—Optometría, Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, Universidade de Santiago de Compostela, Campus Vida S/N, 15705 Santiago de Compostela, Spain; (B.S.-V.); (C.G.-R.); (M.J.G.); (E.Y.-P.)
- Instituto de Investigación Sanitaria (IDIS), Travesía da Choupana S/N, 15706 Santiago de Compostela, Spain
| | - Eva Yebra-Pimentel
- GI-2092—Optometría, Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, Universidade de Santiago de Compostela, Campus Vida S/N, 15705 Santiago de Compostela, Spain; (B.S.-V.); (C.G.-R.); (M.J.G.); (E.Y.-P.)
- Instituto de Investigación Sanitaria (IDIS), Travesía da Choupana S/N, 15706 Santiago de Compostela, Spain
| |
Collapse
|