1
|
Spiliopoulos S, Giannikouris IE, Katsanos K, Filippou P, Efthymiou E, Reppas L, Kitrou P, Palialexis K, Filippiadis D, Brountzos E. VOLume flow assistance for optimizing outcomes of dysfunctional autologous arteriovenous fistula Angioplasty: the VOLA Pilot Study. Eur Radiol 2022; 32:368-376. [PMID: 34195887 DOI: 10.1007/s00330-021-08139-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Revised: 06/01/2021] [Accepted: 06/06/2021] [Indexed: 02/05/2023]
Abstract
OBJECTIVES To investigate the feasibility of VF-assisted angioplasty (VFA) in dysfunctional AVF using sequential intraprocedural duplex ultrasound (DUS), to utilize intraprocedural VF as a quantifiable, functional endpoint in endovascular treatment. METHODS This prospective study included 20 consecutive patients (23 lesions; 16 men; mean age 67 ± 16 years) with dysfunctional AVF undergoing fluoroscopically guided balloon angioplasty between June 2019 and May 2020. Primary endpoints were quantification of outcome using sequential DUS VF analysis following each dilation, 6-month target lesion re-intervention (TLR)-free rate, standard technical success, procedural success (achievement of a postprocedural VF value equal (or 10% less) or superior to the baseline steady-state access), and correlation between procedural success and TLR-free rate. Secondary endpoints included 6-month lesion late lumen loss (LLL), correlation between balloon diameter used and intraprocedural VF values, and correlation between VF and LLL at 6 months follow-up. RESULTS Mean VF increase was 168.5% ± 102.5% (range: 24.24-493.33%). Procedural success was 80% (16/20 cases). VFA improved procedural success by 20% (4/20 cases) compared to standard assessment (< 30% residual stenosis and palpable thrill). TLR-free rate was 78.3% and 67.3% at 6 and 12 months. Significantly less TLR was noted in cases of procedural success (82.4% vs. 66.7% 6 months; p = 0.041). Unweighted linear regression showed a significant positive relationship between diameter of balloon and VF (146.9 ± 42.3 mL/min VF gain per mm of balloon diameter; p = 0.001, R2 = 0.23) and a significant negative relationship between LLL and VF decline at follow-up (102.0 ± 34.6 mL/min loss per mm of LLL; p = 0.01, R2 = 0.35). Optimal VF cutoff value and percentile increase to predict access failure were 720 mL/min (sensitivity 58.3%, specificity 71.4%) and 153% (sensitivity 66.7%, specificity 85.7%), respectively. CONCLUSION Intraprocedural VF assessment could be used to optimize AVF angioplasty. KEY POINTS • A newly proposed functional endpoint of angioplasty in dysfunctional dialysis fistula was evaluated and angioplasty outcome was quantified using volume flow (VF) assessment with sequential intraprocedural DUS. • Intraprocedural VF assessment improved immediate procedural success; increased balloon diameter was correlated with VF gain and late lumen loss with VF decline. • Intraprocedural VF values ≥ to baseline steady-state values were correlated with less re-interventions.
Collapse
Affiliation(s)
- Stavros Spiliopoulos
- 2nd Department of Radiology, Interventional Radiology Unit, Medical School, National and Kapodistrian University of Athens, "Attikon" University General Hospital, Rimini 1st St, 12461, Chaidari, Athens, Greece.
| | | | - Konstantinos Katsanos
- Department of Interventional Radiology, School of Medicine, Patras University Hospital, Rion, Greece
| | - Panagiotis Filippou
- 2nd Department of Radiology, Interventional Radiology Unit, Medical School, National and Kapodistrian University of Athens, "Attikon" University General Hospital, Rimini 1st St, 12461, Chaidari, Athens, Greece
| | - Evgenia Efthymiou
- 2nd Department of Radiology, Interventional Radiology Unit, Medical School, National and Kapodistrian University of Athens, "Attikon" University General Hospital, Rimini 1st St, 12461, Chaidari, Athens, Greece
| | - Lazaros Reppas
- 2nd Department of Radiology, Interventional Radiology Unit, Medical School, National and Kapodistrian University of Athens, "Attikon" University General Hospital, Rimini 1st St, 12461, Chaidari, Athens, Greece
| | - Panagiotis Kitrou
- Department of Interventional Radiology, School of Medicine, Patras University Hospital, Rion, Greece
| | - Konstantinos Palialexis
- 2nd Department of Radiology, Interventional Radiology Unit, Medical School, National and Kapodistrian University of Athens, "Attikon" University General Hospital, Rimini 1st St, 12461, Chaidari, Athens, Greece
| | - Dimitrios Filippiadis
- 2nd Department of Radiology, Interventional Radiology Unit, Medical School, National and Kapodistrian University of Athens, "Attikon" University General Hospital, Rimini 1st St, 12461, Chaidari, Athens, Greece
| | - Elias Brountzos
- 2nd Department of Radiology, Interventional Radiology Unit, Medical School, National and Kapodistrian University of Athens, "Attikon" University General Hospital, Rimini 1st St, 12461, Chaidari, Athens, Greece
| |
Collapse
|
2
|
Tan RY, Chong TT, Tsai FC, Pang SC, Lee KG, Gogna A, Ong AH, Tan CS. A pilot study on adjunctive use of parametric colour-coded digital subtraction angiography in endovascular interventions of haemodialysis access. BMC Med Imaging 2018; 18:28. [PMID: 30219054 PMCID: PMC6139131 DOI: 10.1186/s12880-018-0270-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2018] [Accepted: 08/24/2018] [Indexed: 11/10/2022] Open
Abstract
Background Two-dimensional digital subtraction angiography (DSA) is the gold standard for angiographic evaluation of dysfunctional haemodialysis access. We aim to investigate the utility of parametric colour coded DSA in providing hemodynamic analysis during haemodialysis access interventions. Methods We retrospectively studied 20 patients who underwent access intervention and applied parametric colour-coding on selected DSA acquisitions before and after percutaneous transluminal angioplasty (PTA). The difference in time to peak (dTTP) contrast enhancement and time attenuation curve (TAC) of pre- and post-stenotic regions of interest (ROIs) were obtained and compared after treatment. Results Improvements were seen in mean percent of stenosis after PTA (p < 0.0001) for all cases. Median dTTP improved from 0.52 (IQR 0.26, 0.8) to 0.25 (IQR 0, 0.26) seconds (p = 0.001). Median 50% contrast washout time improved from 0.77 (IQR 0.39, 1.17) to 0.42 (IQR 0.23, 0.59) seconds (p = 0.031). Significant correlation was seen for dTTP vs. percent of stenosis (r = 0.723, p = 0.043) pre-PTA and for change in dTTP vs. percent change in stenosis post-PTA (r = 0.786, p = 0.021) for inflow lesions. Such correlation was however not seen in outflow lesions. Conclusions Adjunctive use of parametric colour-coded DSA may provide potentially useful hemodynamic information during vascular access interventions. Larger prospective studies are needed to validate our findings.
Collapse
Affiliation(s)
- Ru Yu Tan
- Department of Renal Medicine, Singapore General Hospital, Singapore, Singapore.
| | - Tze Tec Chong
- Department of Vascular Surgery, Singapore General Hospital, Singapore, Singapore
| | - Fu Chieh Tsai
- Department of Vascular and Interventional Radiology, Singapore General Hospital, Singapore, Singapore
| | - Suh Chien Pang
- Department of Renal Medicine, Singapore General Hospital, Singapore, Singapore
| | - Kian Guan Lee
- Department of Renal Medicine, Singapore General Hospital, Singapore, Singapore
| | - Apoorva Gogna
- Department of Vascular and Interventional Radiology, Singapore General Hospital, Singapore, Singapore
| | | | - Chieh Suai Tan
- Department of Renal Medicine, Singapore General Hospital, Singapore, Singapore
| |
Collapse
|
3
|
Sidhu A, Tan KT, Noel-Lamy M, Simons ME, Rajan DK. Does Technical Success of Angioplasty in Dysfunctional Hemodialysis Accesses Correlate with Access Patency? Cardiovasc Intervent Radiol 2016; 39:1400-6. [PMID: 27334570 DOI: 10.1007/s00270-016-1401-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/11/2016] [Accepted: 06/15/2016] [Indexed: 10/21/2022]
Abstract
PURPOSE To study if <30 % residual stenosis post angioplasty (PTA) correlates with primary access circuit patency, and if any variables predict technical success. MATERIALS AND METHODS A prospective observational study was performed between January 2009 and December 2012, wherein 76 patients underwent 154 PTA events in 56 prosthetic grafts (AVG) and 98 autogenous fistulas (AVF). Data collected included patient age, gender, lesion location and laterality, access type and location, number of prior interventions, and transonic flow rates pre- and postintervention. Impact of technical outcome on access patency was assessed. Univariate logistic regression was used to assess the impact of variables on technical success with significant factors assessed with a multiple variable model. RESULTS Technical success rates of PTA in AVFs and AVGs were 79.6 and 76.7 %, respectively. Technical failures of PTA were associated with an increased risk of patency loss among circuits with AVFs (p < 0.05), but not with AVGs (p = 0.7). In AVFs, primary access patency rates between technical successes and failures at three and 6 months were 74.4 versus 61.9 % (p = 0.3) and 53.8 versus 23.8 % (p < 0.05), respectively. In AVGs, primary access patency rates between technical successes and failures at three and six months were 72.1 versus 53.9 % (p = 0.5) and 33.6 versus 38.5 % (p = 0.8), respectively. Transonic flow rates did not significantly differ among technically successful or failed outcomes at one or three months. CONCLUSION Technical failures of PTA had a significant impact on access patency among AVFs with a trend toward poorer access patency within AVGs.
Collapse
Affiliation(s)
- Arshdeep Sidhu
- Division of Vascular and Interventional Radiology, Peter Munk Cardiac Center, University Health Network, University of Toronto, 585 University Ave, NCSB 1C-553, Toronto, ON, M5G 2N2, Canada.,Department of Radiology, Providence Hospital and Medical Centers, 16001 W 9 Mile Rd., Southfield, MI, 48075, USA
| | - Kong T Tan
- Division of Vascular and Interventional Radiology, Peter Munk Cardiac Center, University Health Network, University of Toronto, 585 University Ave, NCSB 1C-553, Toronto, ON, M5G 2N2, Canada
| | - Maxime Noel-Lamy
- Division of Vascular and Interventional Radiology, Peter Munk Cardiac Center, University Health Network, University of Toronto, 585 University Ave, NCSB 1C-553, Toronto, ON, M5G 2N2, Canada
| | - Martin E Simons
- Division of Vascular and Interventional Radiology, Peter Munk Cardiac Center, University Health Network, University of Toronto, 585 University Ave, NCSB 1C-553, Toronto, ON, M5G 2N2, Canada
| | - Dheeraj K Rajan
- Division of Vascular and Interventional Radiology, Peter Munk Cardiac Center, University Health Network, University of Toronto, 585 University Ave, NCSB 1C-553, Toronto, ON, M5G 2N2, Canada.
| |
Collapse
|
5
|
García-Medina J. Invasive radiologic management of hemodialysis fistulas: measuring flow with an endovascular catheter. RADIOLOGIA 2014; 57:150-5. [PMID: 24731515 DOI: 10.1016/j.rx.2013.11.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2013] [Revised: 11/05/2013] [Accepted: 11/18/2013] [Indexed: 10/25/2022]
Abstract
OBJECTIVES To analyze the values of flow obtained with an endovascular catheter, and to determine whether they are more reliable than angiographic and clinical findings for planning and for determining the outcome of invasive radiologic treatment of hemodialysis fistulas, as well as to determine the safety of this technique during interventional radiology procedures. MATERIAL AND METHODS We used endovascular catheters to measure flow in 341 vascular accesses for hemodialysis (162 [47.6%] distal fistulas, 132 [38.4%] humeral fistulas, and 47 [14%] arteriovenous grafts) in 598 procedures (a total of 3,051 flow measurements). Dysfunction was most commonly due to high pressures and flow deficits. RESULTS The catheter was used to measure the results of radiologic treatment in 419 (70%) cases and only to measure the control of flow in the hemodialysis access in 179 (30%) cases. In the cases where lesions of the access had been treated radiologically, the flow improved by a mean of 1,232ml/min. In 2 (0.35%) cases, the tip of the catheter perforated the wall of the vein; this complication was resolved by inflating a low pressure balloon. CONCLUSIONS Endovascular catheters are useful for measuring flow in invasive vascular radiology procedures for hemodialysis. In assessing the hemodynamic status of a vascular access, they are most helpful in determining whether stenosis is present.
Collapse
Affiliation(s)
- J García-Medina
- Sección de Radiología Vascular, Servicio de Radiología, Hospital General Universitario Reina Sofía, Murcia, España.
| |
Collapse
|
6
|
Leontiev O, Shlansky-Goldberg RD, Stavropoulos SW, Mondschein JI, Itkin M, Clark TW, Trerotola SO. Should All Inflow Stenoses Be Treated in Failing Autogenous Hemodialysis Fistulae? J Vasc Interv Radiol 2014; 25:542-7. [DOI: 10.1016/j.jvir.2013.12.566] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2013] [Revised: 12/20/2013] [Accepted: 12/21/2013] [Indexed: 11/16/2022] Open
|