Parikh SA, Schneider PA, Mullin CM, Rogers T, Gray WA. Mortality in randomised controlled trials using paclitaxel-coated devices for femoropopliteal interventional procedures: an updated patient-level meta-analysis.
Lancet 2023;
402:1848-1856. [PMID:
37890499 DOI:
10.1016/s0140-6736(23)02189-x]
[Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/08/2023] [Revised: 09/22/2023] [Accepted: 09/27/2023] [Indexed: 10/29/2023]
Abstract
BACKGROUND
Numerous randomised clinical trials and real-world studies have supported the safety of paclitaxel-coated devices for the treatment of femoropopliteal occlusive disease. However, a 2018 summary-level meta-analysis suggested an increased mortality risk for paclitaxel-coated devices compared with uncoated control devices. This study presents an updated analysis of deaths using the most complete and current data available from pivotal trials of paclitaxel-coated versus control devices.
METHODS
Ten trials comparing paclitaxel-coated versus control devices were included in a patient-level pooled analysis. Cox regression models were used to evaluate the effect of paclitaxel exposure on risk of death in both intention-to-treat (ITT; primary analysis) and three as-treated analysis sets accounting for treatment group crossover at the index procedure and over time. The effect of paclitaxel dose and baseline covariates were also evaluated.
FINDINGS
A total of 2666 participants were included with a median follow-up of 4·9 years. No significant increase in deaths was observed for patients treated with paclitaxel-coated devices. This was true in the ITT analysis (hazard ratio [HR] 1·14, 95% CI 0·93-1·40), the as-treated analysis (HR 1·13, 95% CI 0·92-1·39), and in two crossover analyses: 1·07 (0·87-1·31) when late crossovers were censored and 1·04 (0·84-1·28) when crossovers were analysed from the date of paclitaxel exposure. There was no significant effect of paclitaxel dose on mortality risk.
INTERPRETATION
This meta-analysis found no association between paclitaxel-coated device exposure and risk of death, providing reassurance to patients, physicians, and regulators on the safety of paclitaxel-coated devices.
FUNDING
Becton Dickinson, Boston Scientific, Cook, Medtronic, Philips, Surmodics, and TriReme Medical.
Collapse