1
|
Veerman QWT, Ten Heggeler RM, Tuijthof GJM, de Graaff F, Fluit R, Hoogeslag RAG. High variability exists in 3D leg alignment analysis, but underlying principles that might lead to agreement on a universal framework could be identified: A systematic review. Knee Surg Sports Traumatol Arthrosc 2025; 33:2063-2077. [PMID: 39460613 DOI: 10.1002/ksa.12512] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/21/2024] [Revised: 09/22/2024] [Accepted: 09/23/2024] [Indexed: 10/28/2024]
Abstract
PURPOSE To (1) investigate the hypothesis that there is high variability in the reported methods to derive axes and joint orientations from three-dimensional (3D) bone models to (a) perform 3D knee-related leg alignment analysis and (b) define coordinate systems for the femur, tibia and leg and (2) identify underlying principles that might lead to agreement on a universal 3D leg alignment analysis framework. METHODS A systematic review of the literature between January 2006 and June 2024 was performed. Articles explicitly reporting methods to derive axes and joint orientations from CT-based 3D bone models for alignment parameters and/or coordinate systems of the femur, tibia and leg were included. Study characteristics and reported methods were extracted and presented as a qualitative synthesis. RESULTS A total of 93 studies were included. There was high variability in the reported methods to derive axes and joint orientations from 3D bone models. Nevertheless, the reported methods could be categorized into four groups, and several underlying principles of the four groups could be identified. Furthermore, the definitions of femoral and tibial coordinate systems were most frequently based on the mechanical axis (femoral, 13/19 [68%]; tibial, 13/26 [50%]) and a central medial-lateral axis (femoral, 16/19 [84%]; tibial, 12/26 [46%]); no leg coordinate system was reported. Interestingly, of the included studies that reported on leg alignment parameters (76/93, 82%), only a minority reported expressing these in a complete coordinate system (25/76, 33%). CONCLUSION There is high variability in 3D knee-related leg alignment analysis. Therefore, universal 3D reference values for alignment parameters cannot yet be defined, and comparison of alignment parameter values between different studies is impossible. However, several underlying principles to the reported methods were identified, which could serve to reach more agreement on a future universal 3D framework for leg alignment analysis. LEVEL OF EVIDENCE Level I.
Collapse
Affiliation(s)
- Quinten W T Veerman
- OCON Centre for Orthopaedic Surgery and Sports Medicine, Hengelo, the Netherlands
- Faculty of Engineering Technology, University of Twente, Enschede, the Netherlands
| | - Romy M Ten Heggeler
- OCON Centre for Orthopaedic Surgery and Sports Medicine, Hengelo, the Netherlands
- Faculty of Engineering Technology, University of Twente, Enschede, the Netherlands
| | | | - Feike de Graaff
- OCON Centre for Orthopaedic Surgery and Sports Medicine, Hengelo, the Netherlands
| | - René Fluit
- Faculty of Science and Engineering, University of Groningen, Groningen, the Netherlands
| | - Roy A G Hoogeslag
- OCON Centre for Orthopaedic Surgery and Sports Medicine, Hengelo, the Netherlands
| |
Collapse
|
2
|
Kage T, Kono K, Tomita T, Yamazaki T, Taketomi S, Yamagami R, Kawaguchi K, Murakami R, Arakawa T, Kobayashi T, Tanaka S, Inui H. In vivo kinematic comparison of bi-cruciate retaining total knee arthroplasty between mechanical alignment and functional alignment methods. Asia Pac J Sports Med Arthrosc Rehabil Technol 2024; 38:14-21. [PMID: 39315350 PMCID: PMC11417494 DOI: 10.1016/j.asmart.2024.09.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2024] [Revised: 07/11/2024] [Accepted: 09/01/2024] [Indexed: 09/25/2024] Open
Abstract
Background/objective This study aimed to clarify the kinematics of bi-cruciate-retaining (BCR) total knee arthroplasty (TKA) by comparing the mechanical alignment (MA) and functional alignment (FA) methods and to evaluate differences between the two alignment methods. Methods The in vivo kinematics of 20 MA TKA and 20 FA TKA knees were investigated under fluoroscopy during squatting using a two-to three-dimensional registration technique. Accordingly, knee flexion angle, axial rotational angle, varus-valgus angle, anteroposterior translation of the medial and lateral low contact points of the femoral component relative to the tibial component and kinematic pathway were evaluated. Results No difference in the knee flexion angle was observed between the MA and FA TKA groups. Femoral external rotation was observed in both groups and no significant difference was observed. Significant varus alignment from extension to early flexion range was observed in the FA TKA group. The posterior translation of the medial side was smaller in the FA TKA group than in the MA TKA group. Conversely, no significant difference in the anteroposterior translation of the lateral side was observed. In the kinematic pathway, a medial pivot motion from 0° to 20° of flexion and a lateral pivot motion beyond 20° of flexion were observed in both groups. Conclusion During squatting in BCR TKA, the FA TKA group significantly showed varus alignment and smaller posterior translation of the medial side than the MA TKA group from extension to early flexion range.
Collapse
Affiliation(s)
- Tomofumi Kage
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan
| | - Kenichi Kono
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan
| | - Tetsuya Tomita
- Graduate School of Health Sciences, Morinomiya University of Medical Sciences, 1-26-16 Nankokita, Suminoe-ku, Osaka, 559-8611, Japan
| | - Takaharu Yamazaki
- Department of Information Systems, Faculty of Engineering, Saitama Institute of Technology, 1690 Fusaiji, Fukaya, Saitama 369-0293, Japan
| | - Shuji Taketomi
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan
| | - Ryota Yamagami
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan
| | - Kohei Kawaguchi
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan
| | - Ryo Murakami
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan
| | - Takahiro Arakawa
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan
| | - Takashi Kobayashi
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan
| | - Sakae Tanaka
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan
| | - Hiroshi Inui
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan
- Department of Orthopaedic Surgery, Saitama Medical Center, Saitama Medical University, 1981 Kamoda, Kawagoe City, Saitama 350-8500, Japan
| |
Collapse
|
3
|
Inui H, Yamagami R, Kono K, Kawaguchi K, Kage T, Murakami R, Nakamura H, Saita K, Taketomi S, Tanaka S. Short-term clinical results of bicruciate-retaining total knee arthroplasty using personalized alignment. BMC Musculoskelet Disord 2023; 24:965. [PMID: 38087214 PMCID: PMC10714564 DOI: 10.1186/s12891-023-07083-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Accepted: 11/30/2023] [Indexed: 12/18/2023] Open
Abstract
BACKGROUND Bicruciate-retaining (BCR) prosthesis has been introduced to recreate normal knee movement by preserving both the anterior and posterior cruciate ligaments. However, the use of BCR total knee arthroplasty (TKA) is still debatable because of several disappointing reports. We have been performing BCR TKAs with personalized alignment (PA). This study aimed to reveal the limb alignment and soft tissue balance of FA-BCR TKAs and compare the clinical outcomes of FA-BCR TKAs with those of unicompartmental knee arthroplasty (UKA). METHODS Fifty BCR TKAs and 58 UKAs were included in this study. The joint component gaps of BCR TKA were evaluated intraoperatively and the postoperative hip-knee-ankle (HKA) angle, medial proximal tibial angle (MPTA), and lateral distal femoral angle (LDFA) were measured using full-length standing radiography. The short-term clinical outcomes of BCR TKAs were compared with those of UKA using the scoring system of 2011 Knee Society Scoring (KSS) and the knee injury and osteoarthritis outcome score (KOOS) at an average of 2 years postoperatively (1-4yeras). RESULTS The coronal alignment values of PA-BCR TKA were as follows: HKA angle, 177.9° ± 2.3°; MPTA, 85.4° ± 1.9°; and LDFA, 87.5° ± 1.9°. The joint component gaps at flexion angles of 10°, 30°, 60°, and 90° were 11.1 ± 1.2, 10.9 ± 1.4, 10.7 ± 1.3, and 11.2 ± 1.4 mm for the medial compartment and 12.9 ± 1.5, 12.6 ± 1.8, 12.5 ± 1.8 and 12.5 ± 1.7 mm for the lateral compartment, respectively. The patient expectation score and maximum extension angle of PA-BCR TKA were significantly better than those of UKAs. CONCLUSIONS The short-term clinical outcomes of PA-BCR TKA were comparable or a slightly superior to those of UKAs.
Collapse
Affiliation(s)
- Hiroshi Inui
- Saitama Medical Center, Saitama Medical University, 1981 Kamoda, Kawagoe City, Saitama, 350-8500, Japan.
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan.
| | - Ryota Yamagami
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
| | - Kenichi Kono
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
| | - Kohei Kawaguchi
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
| | - Tomofumi Kage
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
| | - Ryo Murakami
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
| | - Haruhiko Nakamura
- Saitama Medical Center, Saitama Medical University, 1981 Kamoda, Kawagoe City, Saitama, 350-8500, Japan
| | - Kazuo Saita
- Saitama Medical Center, Saitama Medical University, 1981 Kamoda, Kawagoe City, Saitama, 350-8500, Japan
| | - Shuji Taketomi
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
| | - Sakae Tanaka
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
| |
Collapse
|
4
|
Yamamoto A, Kaneko T, Takada K, Yoshizawa S. The importance of selecting a cruciate-retaining total knee prosthesis for a patient with a large physiological posterior tibial slope: a case report. J Surg Case Rep 2022; 2022:rjac584. [PMID: 36570546 PMCID: PMC9769956 DOI: 10.1093/jscr/rjac584] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Accepted: 11/27/2022] [Indexed: 12/24/2022] Open
Abstract
For Japanese individuals, deep bending is inevitable in their daily lives, such as during seiza sitting and kneeling. Thus, achieving a good post-operative range of motion is an important factor in improving patient satisfaction. Even normal knees often have a posterior tibial slope of more than 10°. We report the case of a 76-year-old woman who underwent proximal tibial osteotomy at 8° with the Vanguard Knee cruciate retaining total knee arthroplasty (TKA) system. She required the revision TKA 10 years later due to ultra-high-molecular-weight polyethylene wear and breakage of the posteromedial tibial component.
Collapse
Affiliation(s)
- Ayakane Yamamoto
- Ichinomiya Onsen Hot Hospital, Adult Reconstruction Center, 1745 Tsuboi, Ichinomiyacho, Fuefuki-city, Yamanashi 405-0077, Japan
| | - Takao Kaneko
- Correspondence address. Ichinomiya Onsen Hot Hospital, Adult Reconstruction Center, 1745 Tsuboi, Ichinomiyacho, Fuefuki-city, Yamanashi 405-0077, Japan. Tel: +81-553-47-3131; Fax: + 81-553-47-3434; E-mail:
| | - Kazutaka Takada
- Ichinomiya Onsen Hot Hospital, Adult Reconstruction Center, 1745 Tsuboi, Ichinomiyacho, Fuefuki-city, Yamanashi 405-0077, Japan
| | - Shu Yoshizawa
- Ichinomiya Onsen Hot Hospital, Adult Reconstruction Center, 1745 Tsuboi, Ichinomiyacho, Fuefuki-city, Yamanashi 405-0077, Japan
| |
Collapse
|