1
|
Lemine AS, Ahmad Z, Al-Thani NJ, Hasan A, Bhadra J. Mechanical properties of human hepatic tissues to develop liver-mimicking phantoms for medical applications. Biomech Model Mechanobiol 2024; 23:373-396. [PMID: 38072897 PMCID: PMC10963485 DOI: 10.1007/s10237-023-01785-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Accepted: 10/17/2023] [Indexed: 03/26/2024]
Abstract
Using liver phantoms for mimicking human tissue in clinical training, disease diagnosis, and treatment planning is a common practice. The fabrication material of the liver phantom should exhibit mechanical properties similar to those of the real liver organ in the human body. This tissue-equivalent material is essential for qualitative and quantitative investigation of the liver mechanisms in producing nutrients, excretion of waste metabolites, and tissue deformity at mechanical stimulus. This paper reviews the mechanical properties of human hepatic tissues to develop liver-mimicking phantoms. These properties include viscosity, elasticity, acoustic impedance, sound speed, and attenuation. The advantages and disadvantages of the most common fabrication materials for developing liver tissue-mimicking phantoms are also highlighted. Such phantoms will give a better insight into the real tissue damage during the disease progression and preservation for transplantation. The liver tissue-mimicking phantom will raise the quality assurance of patient diagnostic and treatment precision and offer a definitive clinical trial data collection.
Collapse
Affiliation(s)
- Aicha S Lemine
- Department of Mechanical and Industrial Engineering, College of Engineering, Qatar University, 2713, Doha, Qatar
- Qatar University Young Scientists Center (QUYSC), Qatar University, 2713, Doha, Qatar
| | - Zubair Ahmad
- Qatar University Young Scientists Center (QUYSC), Qatar University, 2713, Doha, Qatar
- Center for Advanced Materials (CAM), Qatar University, PO Box 2713, Doha, Qatar
| | - Noora J Al-Thani
- Qatar University Young Scientists Center (QUYSC), Qatar University, 2713, Doha, Qatar
| | - Anwarul Hasan
- Department of Mechanical and Industrial Engineering, College of Engineering, Qatar University, 2713, Doha, Qatar
| | - Jolly Bhadra
- Qatar University Young Scientists Center (QUYSC), Qatar University, 2713, Doha, Qatar.
- Center for Advanced Materials (CAM), Qatar University, PO Box 2713, Doha, Qatar.
| |
Collapse
|
2
|
Bisht SR, Paul A, Patel P, Thareja P, Mercado-Shekhar KP. Systematic quantification of differences in shear wave elastography estimates between linear-elastic and viscoelastic material assumptionsa). THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2024; 155:2025-2036. [PMID: 38470185 DOI: 10.1121/10.0025291] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Accepted: 02/27/2024] [Indexed: 03/13/2024]
Abstract
Quantitative, accurate, and standardized metrics are important for reliable shear wave elastography (SWE)-based biomarkers. For over two decades, the linear-elastic material assumption has been employed in SWE modes. In recent years, viscoelasticity estimation methods have been adopted in a few clinical systems. The current study aims to systematically quantify differences in SWE estimates obtained using linear-elastic and viscoelastic material assumptions. An acousto-mechanical simulation framework of acoustic radiation force impulse-based SWE was created to elucidate the effect of material viscosity and shear modulus on SWE estimates. Shear modulus estimates exhibited errors up to 72% when a numerical viscoelastic phantom was assessed as linearly elastic. Shear modulus estimates of polyvinyl alcohol phantoms between rheometry and SWE following the Kelvin-Voigt viscoelastic model assumptions were not significantly different. However, the percentage difference in shear modulus estimates between rheometry and SWE using the linear-elastic assumption was 50.1%-62.1%. In ex vivo liver, the percentage difference in shear modulus estimates between linear-elastic and viscoelastic methods was 76.1%. These findings provide a direct and systematic quantification of the potential error introduced when viscoelastic tissues are imaged with SWE following the linear-elastic assumption. This work emphasizes the need to utilize viscoelasticity estimation methods for developing robust quantitative imaging biomarkers.
Collapse
Affiliation(s)
- Sapna R Bisht
- Department of Biological Sciences and Engineering, Indian Institute of Technology Gandhinagar, Gandhinagar, Gujarat 382355, India
| | - Abhijit Paul
- Department of Biological Sciences and Engineering, Indian Institute of Technology Gandhinagar, Gandhinagar, Gujarat 382355, India
| | - Panchami Patel
- Department of Chemical Engineering, Indian Institute of Technology Gandhinagar, Gandhinagar, Gujarat 382355, India
| | - Prachi Thareja
- Department of Chemical Engineering, Indian Institute of Technology Gandhinagar, Gandhinagar, Gujarat 382355, India
| | - Karla P Mercado-Shekhar
- Department of Biological Sciences and Engineering, Indian Institute of Technology Gandhinagar, Gandhinagar, Gujarat 382355, India
| |
Collapse
|
3
|
Helisaz H, Belanger E, Black P, Bacca M, Chiao M. Quantifying the Impact of Cancer on the Viscoelastic Properties of the Prostate Gland using a Quasi-Linear Viscoelastic Model. Acta Biomater 2024; 173:184-198. [PMID: 37939817 DOI: 10.1016/j.actbio.2023.11.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Revised: 10/27/2023] [Accepted: 11/01/2023] [Indexed: 11/10/2023]
Abstract
Pathological disorders can alter the mechanical properties of biological tissues, and studying such changes can help to better understand the disease progression. The prostate gland is no exception, as previous studies have shown that cancer can affect its mechanical properties. However, most of these studies have focused on the elastic properties of the tissue and have overlooked the impact of cancer on its viscous response. To address this gap, we used a quasi-linear viscoelastic model to investigate the impact of cancer on both the elastic and viscous characteristics of the prostate gland. By comparing the viscoelastic properties of segments influenced by cancer and those unaffected by cancer in 49 fresh prostates, removed within two hours after prostatectomy surgery, we were able to determine the influence of cancer grade and tumor volume on the tissue. Our findings suggest that tumor volume significantly affects both the elastic modulus and viscosity of the prostate (p-value less than 2%). Specifically, we showed that cancer increases Young's modulus and shear relaxation modulus by 20%. These results have implications for using mechanical properties of the prostate as a potential biomarker for cancer. However, developing an in vivo apparatus to measure these properties remains a challenge that needs to be addressed in future research. STATEMENT OF SIGNIFICANCE: This study is the first to explore how cancer impacts the mechanical properties of prostate tissues using a quasi-linear viscoelastic model. We examined 49 fresh prostate samples collected immediately after surgery and correlated their properties with cancer presence identified in pathology reports. Our results demonstrate a 20% change in the viscoelastic properties of the prostate due to cancer. We initially validated our approach using tissue-mimicking phantoms and then applied it to differentiate between cancerous and normal prostate tissues. These findings offer potential for early cancer detection by assessing these properties. However, conducting these tests in vivo remains a challenge for future research.
Collapse
Affiliation(s)
- Hamed Helisaz
- Department of Mechanical Engineering, University of British Columbia, V6T 1Z4, BC, Canada
| | - Eric Belanger
- Department of Pathology and Laboratory Medicine, University of British Columbia, V6T 1Z4, BC, Canada
| | - Peter Black
- Department of Urologic Sciences, University of British Columbia, Vancouver, V6T 1Z4, BC, Canada
| | - Mattia Bacca
- Department of Mechanical Engineering, University of British Columbia, V6T 1Z4, BC, Canada
| | - Mu Chiao
- Department of Mechanical Engineering, University of British Columbia, V6T 1Z4, BC, Canada.
| |
Collapse
|
4
|
Zhang XQ, Zheng RQ, Jin JY, Wang JF, Zhang T, Zeng J. US Shear-Wave Elastography Dispersion for Characterization of Chronic Liver Disease. Radiology 2022; 305:597-605. [PMID: 35916675 DOI: 10.1148/radiol.212609] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/07/2022]
Abstract
Background Little is known about the benefits of the use of dispersion slope (DS) as a viscosity-related parameter derived from two-dimensional (2D) shear-wave elastography (SWE) in the stratification of hepatic pathologic stages. Purpose To evaluate whether DS as an additional parameter can improve the diagnostic performance in detecting liver necroinflammation, fibrosis, and steatosis. Materials and Methods In this prospective study, consecutive participants with chronic liver disease who underwent liver biopsy and 2D SWE were recruited between July 2019 and September 2020. DS and liver stiffness (LS) measurements were obtained with use of a 2D SWE system immediately before biopsy. The biopsy specimens were assessed to obtain the scores of fibrosis, necroinflammation, and steatosis. Differences in the area under the receiver operating characteristic curve (AUC) were used to compare the diagnostic performance of DS, LS, and a combination of DS and LS. Results There were 159 participants evaluated (among them, 79 participants with chronic hepatitis B and 11 participants with nonalcoholic fatty liver disease). The distributions of DS values among various necroinflammatory activities (P = .02) and fibrosis stages (P < .001) were different. Moreover, DS was only associated with fibrosis after subgroup analysis based on the fibrosis stages and necroinflammatory activities (P < .001). The AUCs of DS in detecting clinically significant fibrosis (fibrosis stage ≥F2), cirrhosis (fibrosis stage of F4), and moderate to severe necroinflammatory activity (necroinflammatory activity ≥A2) were 0.72 (95% CI: 0.64, 0.79), 0.71 (95% CI: 0.63, 0.78), and 0.64 (95% CI: 0.55, 0.71), respectively. The differences of AUCs were not apparent for the DS and LS combination model after excluding DS (fibrosis stage ≥F2: 0.00 [95% CI: 0.00, 0.01], fibrosis stage of F4: -0.01 [95% CI: -0.02, 0.00], and necroinflammatory activity ≥A2: 0.00 [95% CI: 0.00, 0.01]). Conclusion The addition of dispersion slope derived from two-dimensional shear-wave elastography did not improve the diagnostic performance in detecting liver fibrosis, necroinflammation, or steatosis in patients with primarily viral hepatitis. ClinicalTrials.gov registration no.: NCT03777293 © RSNA, 2022 Online supplemental material is available for this article.
Collapse
Affiliation(s)
- Xiao-Qing Zhang
- From the Department of Medical Ultrasound, Guangdong Key Laboratory of Liver Disease Research, Third Affiliated Hospital of Sun Yat-Sen University, 600 Tianhe Rd, Guangzhou 510630, China
| | - Rong-Qin Zheng
- From the Department of Medical Ultrasound, Guangdong Key Laboratory of Liver Disease Research, Third Affiliated Hospital of Sun Yat-Sen University, 600 Tianhe Rd, Guangzhou 510630, China
| | - Jie-Yang Jin
- From the Department of Medical Ultrasound, Guangdong Key Laboratory of Liver Disease Research, Third Affiliated Hospital of Sun Yat-Sen University, 600 Tianhe Rd, Guangzhou 510630, China
| | - Jin-Fen Wang
- From the Department of Medical Ultrasound, Guangdong Key Laboratory of Liver Disease Research, Third Affiliated Hospital of Sun Yat-Sen University, 600 Tianhe Rd, Guangzhou 510630, China
| | - Ting Zhang
- From the Department of Medical Ultrasound, Guangdong Key Laboratory of Liver Disease Research, Third Affiliated Hospital of Sun Yat-Sen University, 600 Tianhe Rd, Guangzhou 510630, China
| | - Jie Zeng
- From the Department of Medical Ultrasound, Guangdong Key Laboratory of Liver Disease Research, Third Affiliated Hospital of Sun Yat-Sen University, 600 Tianhe Rd, Guangzhou 510630, China
| |
Collapse
|
5
|
Rus G, Faris IH, Torres J, Callejas A, Melchor J. Why Are Viscosity and Nonlinearity Bound to Make an Impact in Clinical Elastographic Diagnosis? SENSORS (BASEL, SWITZERLAND) 2020; 20:E2379. [PMID: 32331295 PMCID: PMC7219338 DOI: 10.3390/s20082379] [Citation(s) in RCA: 45] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/25/2020] [Revised: 04/17/2020] [Accepted: 04/20/2020] [Indexed: 12/24/2022]
Abstract
The adoption of multiscale approaches by the biomechanical community has caused a major improvement in quality in the mechanical characterization of soft tissues. The recent developments in elastography techniques are enabling in vivo and non-invasive quantification of tissues' mechanical properties. Elastic changes in a tissue are associated with a broad spectrum of pathologies, which stems from the tissue microstructure, histology and biochemistry. This knowledge is combined with research evidence to provide a powerful diagnostic range of highly prevalent pathologies, from birth and labor disorders (prematurity, induction failures, etc.), to solid tumors (e.g., prostate, cervix, breast, melanoma) and liver fibrosis, just to name a few. This review aims to elucidate the potential of viscous and nonlinear elastic parameters as conceivable diagnostic mechanical biomarkers. First, by providing an insight into the classic role of soft tissue microstructure in linear elasticity; secondly, by understanding how viscosity and nonlinearity could enhance the current diagnosis in elastography; and finally, by compounding preliminary investigations of those elastography parameters within different technologies. In conclusion, evidence of the diagnostic capability of elastic parameters beyond linear stiffness is gaining momentum as a result of the technological and imaging developments in the field of biomechanics.
Collapse
Affiliation(s)
- Guillermo Rus
- Ultrasonics Group (TEP-959), Department of Structural Mechanics, University of Granada, 18071 Granada, Spain; (G.R.); (I.H.F.); (A.C.)
- Biomechanics Group (TEC-12), Instituto de Investigación Biosanitaria, ibs.GRANADA, 18012 Granada, Spain;
- Excellence Research Unit “ModelingNature” MNat UCE.PP2017.03, University of Granada, 18071 Granada, Spain
| | - Inas H. Faris
- Ultrasonics Group (TEP-959), Department of Structural Mechanics, University of Granada, 18071 Granada, Spain; (G.R.); (I.H.F.); (A.C.)
- Biomechanics Group (TEC-12), Instituto de Investigación Biosanitaria, ibs.GRANADA, 18012 Granada, Spain;
| | - Jorge Torres
- Ultrasonics Group (TEP-959), Department of Structural Mechanics, University of Granada, 18071 Granada, Spain; (G.R.); (I.H.F.); (A.C.)
- Biomechanics Group (TEC-12), Instituto de Investigación Biosanitaria, ibs.GRANADA, 18012 Granada, Spain;
| | - Antonio Callejas
- Ultrasonics Group (TEP-959), Department of Structural Mechanics, University of Granada, 18071 Granada, Spain; (G.R.); (I.H.F.); (A.C.)
- Biomechanics Group (TEC-12), Instituto de Investigación Biosanitaria, ibs.GRANADA, 18012 Granada, Spain;
| | - Juan Melchor
- Biomechanics Group (TEC-12), Instituto de Investigación Biosanitaria, ibs.GRANADA, 18012 Granada, Spain;
- Excellence Research Unit “ModelingNature” MNat UCE.PP2017.03, University of Granada, 18071 Granada, Spain
- Department of Statistics and Operations Research, University of Granada, 18071 Granada, Spain
| |
Collapse
|
6
|
Viscoelasticity in natural tissues and engineered scaffolds for tissue reconstruction. Acta Biomater 2019; 97:74-92. [PMID: 31400521 DOI: 10.1016/j.actbio.2019.08.013] [Citation(s) in RCA: 84] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2019] [Revised: 07/23/2019] [Accepted: 08/06/2019] [Indexed: 02/05/2023]
Abstract
Viscoelasticity of living tissues plays a critical role in tissue homeostasis and regeneration, and its implication in disease development and progression is being recognized recently. In this review, we first explored the state of knowledge regarding the potential application of tissue viscoelasticity in disease diagnosis. In order to better characterize viscoelasticity with local resolution and non-invasiveness, emerging characterization methods have been developed with the potential to be supplemented to existing facilities. To understand cellular responses to matrix viscoelastic behaviors in vitro, hydrogels made of natural polymers have been developed and the relationships between their molecular structure and viscoelastic behaviors, are elucidated. Moreover, how cells perceive the viscoelastic microenvironment and cellular responses including cell attachment, spreading, proliferation, differentiation and matrix production, have been discussed. Finally, some future perspective on an integrated mechanobiological comprehension of the viscoelastic behaviors involved in tissue homeostasis, cellular responses and biomaterial design are highlighted. STATEMENT OF SIGNIFICANCE: Tissue- or organ-scale viscoelastic behavior is critical for homeostasis, and the molecular basis and cellular responses of viscoelastic materials at micro- or nano-scale are being recognized recently. We summarized the potential applications of viscoelasticity in disease diagnosis enabled by emerging non-invasive characterization technologies, and discussed the underlying mechanism of viscoelasticity of hydrogels and current understandings of cell regulatory functions of them. With a growing understanding of the molecular basis of hydrogel viscoelasticity and recognition of its regulatory functions on cell behaviors, it is important to bring the clinical insights on how these characterization technologies and engineered materials may contribute to disease diagnosis and treatment. This review explains the basics in characterizing viscoelasticity with our hope to bridge the gap between basic research and clinical applications.
Collapse
|