1
|
Wang J, Fan Z, Liu J, Liu K, Yan C, Ye X, Deng X. Influence of stent strut and its associated injury on thrombus formation: A dissipative particle dynamics study. J Theor Biol 2024; 595:111929. [PMID: 39197677 DOI: 10.1016/j.jtbi.2024.111929] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2024] [Revised: 08/17/2024] [Accepted: 08/19/2024] [Indexed: 09/01/2024]
Abstract
Vascular stent intervention is a pivotal treatment for coronary atherosclerosis, though in-stent thrombosis remains a significant postoperative complication with an unclear underlying mechanism. This study utilized dissipated particle dynamics analysis to investigate the impact of stent and its injury on platelet behavior. The findings suggest that thrombus formation upstream of the stent is mainly initiated by upstream arterial injury, which leads to increased platelet accumulation and activation in that area. While thrombosis downstream of the stent is more directly influenced by the stent itself. The morphology and size of in-stent thrombosis can vary significantly due to the different contributions of the stent and underlying injuries. Additionally, the volume of in-stent thrombosis is affected by the extent of the injury and the viscosity of platelets, showing a notable increase in volume with the lengthening of the injury area and rise in platelet viscosity. This study provides a novel theoretical framework for optimizing stent placement strategies and structural designs by examining the effects of stent struts and associated injuries on thrombus formation.
Collapse
Affiliation(s)
- Jian Wang
- School of Mechanical Engineering, Jiangsu University of Technology, Changzhou, Jiangsu 213001, China
| | - Zhenmin Fan
- School of Mechanical Engineering, Jiangsu University of Technology, Changzhou, Jiangsu 213001, China.
| | - Jiashuai Liu
- School of Mechanical Engineering, Jiangsu University of Technology, Changzhou, Jiangsu 213001, China
| | - Kailei Liu
- School of Mechanical Engineering, Jiangsu University of Technology, Changzhou, Jiangsu 213001, China
| | - ChaoJun Yan
- Cardiac Surgery Department, Southwest Hospital, Army Medical University, Chongqing 400038, China.
| | - Xia Ye
- School of Mechanical Engineering, Jiangsu University of Technology, Changzhou, Jiangsu 213001, China
| | - Xiaoyan Deng
- School of Mechanical Engineering, Jiangsu University of Technology, Changzhou, Jiangsu 213001, China; Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing 100191, China
| |
Collapse
|
2
|
Yang X, Zhang W, Yao J, Sun A, Gao Y, Guo M, Fan Y. The differences between surface degradation and bulk degradation of FEM on the prediction of the degradation time for poly (lactic-co-glycolic acid) stent. Comput Methods Biomech Biomed Engin 2021; 25:65-72. [PMID: 34582282 DOI: 10.1080/10255842.2021.1931846] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
The degradation time is a crucial factor in evaluating the performance of poly (lactic-co-glycolic acid) (PLGA) stents. Bulk degradation mode was commonly used to analyze the stent degradation behavior by finite element approach. However, the PLGA stents may present surface degradation more than bulk degradation under certain conditions, which will greatly affect the degradation time after implantation. In this study, the degradation processes of the poly (lactic-co-glycolic acid) stent were reproduced utilizing finite element analysis. Both bulk degradation and surface degradation modes were considered. The correlation between tensile stress and degradation rate was investigated. The degradation time was analyzed selectively. The stress distribution, fracture, and mass loss were also compared between bulk degradation mode and surface degradation mode. The simulation results showed that, in both evolution modes, the degradation began at the 'peak-valley' region and fracture occurred at the cross of links and rings. Additionally, high levels of Von-Mises stress were observed in these two regions. Compared with bulk degradation, the fracture time of the stent was delayed by 63% in the surface degradation mode. In conclusion, the mass loss rate and scaffolding period showed great differences between surface degradation and bulk degradation. Based on this study, it is suggested that bulk degradation mode is not applicable to the case of inadequate water uptake mode, such as the tracheal stent degradation process. More experimental research should be carried out to accurately predict the scaffolding period after implantation. The mechanical properties of the fracture zone should be strengthened.
Collapse
Affiliation(s)
- Xianda Yang
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Weirong Zhang
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Jie Yao
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Anqiang Sun
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Yuanming Gao
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China.,School of Engineering Medicine, Beihang University, Beijing, China
| | - Meng Guo
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Yubo Fan
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China.,School of Engineering Medicine, Beihang University, Beijing, China
| |
Collapse
|
3
|
He S, Liu W, Qu K, Yin T, Qiu J, Li Y, Yuan K, Zhang H, Wang G. Effects of different positions of intravascular stent implantation in stenosed vessels on in-stent restenosis: An experimental and numerical simulation study. J Biomech 2020; 113:110089. [PMID: 33181394 DOI: 10.1016/j.jbiomech.2020.110089] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2020] [Revised: 09/08/2020] [Accepted: 10/16/2020] [Indexed: 11/29/2022]
Abstract
Percutaneous coronary intervention (PCI) has been widely used in the treatment of atherosclerosis, while in-stent restenosis (ISR) has not been completely resolved. Studies have shown that changes in intravascular mechanical environment are related to ISR. Hence, an in-depth understanding of the effects of stent intervention on vascular mechanics is important for clinically optimizing stent implantation and relieving ISR. Nine rabbits with stenotic carotid artery were collected by balloon injury. Intravascular stents were implanted into different longitudinal positions (proximal, middle and distal relative to the stenotic area) of the stenotic vessels for numerical simulations. Optical coherence tomography (OCT) scanning was performed to reconstruct the three-dimensional configuration of the stented carotid artery and blood flow velocity waveforms were collected by Doppler ultrasound. The numerical simulations were performed through direct solution of Naiver-Stokes equation in ANSYS. Results showed that the distributions of time-averaged wall shear stress (TAWSS), oscillating shear index (OSI) and relative residual time (RRT) in near-end segment were distinctively different from other regions of the stent which considered to promote restenosis for all three models. Spearman rank-correlation analysis showed a significant correlation between hemodynamic descriptors and the stent longitudinal positions (rTAWSS = -0.718, rOSI = 0.898, rRRT = 0.818, p < 0.01). Histology results of the near-end segment showed neointima thickening deepened with the longitudinal positions of stent which was consistent with the numerical simulations. The results suggest that stent implantation can promote restenosis at the near-end segment. As the stenting position moves to distal end, the impact on ISR is more significant.
Collapse
Affiliation(s)
- Shicheng He
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, PR China; State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, PR China
| | - Wanling Liu
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, PR China
| | - Kai Qu
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, PR China
| | - Tieying Yin
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, PR China
| | - Juhui Qiu
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, PR China.
| | - Yan Li
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, PR China
| | - Kunshan Yuan
- National United Engineering Laboratory for Biomedical Material Modification, Dezhou, Shandong 251100, PR China
| | - Haijun Zhang
- National United Engineering Laboratory for Biomedical Material Modification, Dezhou, Shandong 251100, PR China
| | - Guixue Wang
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, PR China.
| |
Collapse
|
4
|
Carotid Artery Stenting in Asymptomatic Carotid Artery Stenosis: JACC Review Topic of the Week. J Am Coll Cardiol 2020; 75:648-656. [PMID: 32057380 DOI: 10.1016/j.jacc.2019.11.054] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/08/2019] [Accepted: 11/19/2019] [Indexed: 01/22/2023]
Abstract
The advance of therapies to reduce the stroke impact of asymptomatic carotid artery stenosis has proved difficult over the last decade. Disagreement concerning the underlying randomized control trials has limited entry into the care arena of endovascular therapies. Recently, advances in percutaneous therapies for carotid artery disease have been reported and provide a substantial database supporting the further incorporation of endovascular-based therapies in patients who need revascularization and meet selection criteria. With a second randomized control trial now published, it is time for a re-evaluation of endovascular therapy as a component of carotid artery care. This review describes the advances in the field in the last 5 years, clarifying the current position of these therapies in the care of the patient with asymptomatic carotid artery disease.
Collapse
|