1
|
Zeng Y, Peng M, Zhou H, Huang X. Preparation of monolith-based adsorbent mingled with metal organic framework for field microextraction of organic pollutants with significantly distinct properties in water. JOURNAL OF HAZARDOUS MATERIALS 2025; 491:137982. [PMID: 40120264 DOI: 10.1016/j.jhazmat.2025.137982] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/16/2025] [Revised: 03/05/2025] [Accepted: 03/15/2025] [Indexed: 03/25/2025]
Abstract
Field co-extraction of compounds with significantly distinct properties is essential and challenging in the monitoring of organic pollutants. In current study, nitrophenols, aromatic amines and parabens were employed as acidic, basic and neutral model analytes, respectively. To co-capture the analytes efficiently, porous monolith mingled with metal-organic frameworks (MOFs@PM) was prepared by incorporating MIL-53(Al) during in-situ polymerization of ethylene glycol dimethacrylate (EDMA). The prepared MOFs@PM was utilized as the adsorbent of lab-made portable in-tip microextraction apparatus (MEA) for field co-capture of investigated pollutants. Due to the incorporation of MOFs, the extraction efficiencies obtained on MOFs@PM rose by 22.4-192 % over the poly (EDMA) which MOFs did not be mingled. The co-extraction mechanism was studied by molecular simulation method and batch experiments. Under the beneficial conditions, the developed MOFs@PM/MEA technique was used to field separate and simultaneously capture studied analytes and followed by quantified with HPLC. The achieved enhancement factors and limits of detection were in the ranges of 136-172 and 0.011-0.029 μg/L, respectively. Additionally, the reliability and accuracy of the proposed approach was evaluated by recovery and confirmation experiments. Satisfactory results confirm the superior co-extraction performance of MOFs@PM and the wide application prospect of MOFs@PM/MEA technique in field sample preparation.
Collapse
Affiliation(s)
- Yufeng Zeng
- College of the Environment and Ecology, Xiamen University, Xiamen 361005, China; Fujian Provincial Key Laboratory for Coastal Ecology and Environmental Studies, Xiamen University, Xiamen 361005, China; Shenzhen Research Institute of Xiamen University, Shenzhen 518000, China
| | - Mingming Peng
- College of the Environment and Ecology, Xiamen University, Xiamen 361005, China; Fujian Provincial Key Laboratory for Coastal Ecology and Environmental Studies, Xiamen University, Xiamen 361005, China; Shenzhen Research Institute of Xiamen University, Shenzhen 518000, China
| | - Hongbi Zhou
- College of the Environment and Ecology, Xiamen University, Xiamen 361005, China; Fujian Provincial Key Laboratory for Coastal Ecology and Environmental Studies, Xiamen University, Xiamen 361005, China; Shenzhen Research Institute of Xiamen University, Shenzhen 518000, China
| | - Xiaojia Huang
- College of the Environment and Ecology, Xiamen University, Xiamen 361005, China; Fujian Provincial Key Laboratory for Coastal Ecology and Environmental Studies, Xiamen University, Xiamen 361005, China; Shenzhen Research Institute of Xiamen University, Shenzhen 518000, China.
| |
Collapse
|
2
|
Temiz Ş, Ulusoy S, Ulusoy Hİ, Durgun E, Polat Ü, Sarp G. Synthesis and use of new magnetic adsorbent for sensitive, practical and simultaneous analysis Ibuprofen and Ketoprofen molecules in urine samples. J Chromatogr B Analyt Technol Biomed Life Sci 2025; 1251:124404. [PMID: 39689395 DOI: 10.1016/j.jchromb.2024.124404] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2024] [Revised: 11/24/2024] [Accepted: 11/27/2024] [Indexed: 12/19/2024]
Abstract
A new sample preparation and determination method, including HPLC-DAD analysis after Magnetic Solid Phase Extraction (MSPE), was developed to monitor the trace amounts of two types of nonsteroidal anti-inflammatory drugs (NSAIDs), Ibuprofen (IBP) and Ketoprofen (KP). In the proposed method, IBP and KP analytes were extracted from newly synthesized magnetic-based sorbent in a pH 4.0 buffer medium and enriched by desorbing again with ethanol to a smaller volume before chromatographic determinations. The samples were filtered and transferred to HPLC vials before analysis. The experimental variables were optimized step by step such as adsorption time, desorption solvent, pH, etc. After preconcentration of IBP and KP molecules by MSPE, determination of target molecules was carried out by isocratic elution of 30 % Methyl alcohol, 40 % Trifluoro Acetic Acid (TFA) (0.1 %, v:v), 30 % Acetonitrile. By using optimized conditions, the detection limits of target molecules were calculated as 3.43 ng mL-1 and 3.48 ng mL-1 for IBP and KP, respectively. The triplicate measurements made with model solutions containing 100 ng mL-1 of target molecules, RSD %values were found below 3.50 %. The developed method was successfully applied to synthetic urine and pooling urine samples. Finally, the practicality and suitability for green analytical chemistry of the proposed method was evaluated by using Blue Applicability Grade Index (BAGI) and Green Analytical Procedure Index (GAPI).
Collapse
Affiliation(s)
- Şule Temiz
- Department of Analytical Chemistry, Faculty of Pharmacy, Sivas Cumhuriyet University, Sivas, Turkiye
| | - Songül Ulusoy
- Department of Pharmacy, Vocational School of Health Service, Sivas Cumhuriyet University, Sivas, Turkiye.
| | - Halil İbrahim Ulusoy
- Department of Analytical Chemistry, Faculty of Pharmacy, Sivas Cumhuriyet University, Sivas, Turkiye
| | - Esra Durgun
- Department of Analytical Chemistry, Faculty of Pharmacy, Sivas Cumhuriyet University, Sivas, Turkiye
| | - Ümmügülsüm Polat
- Department of Analytical Chemistry, Faculty of Pharmacy, Sivas Cumhuriyet University, Sivas, Turkiye
| | - Gökhan Sarp
- Department of Analytical Chemistry, Faculty of Pharmacy, Erciyes University, Kayseri, Turkiye
| |
Collapse
|
3
|
Shahsavani A, Fakhari AR. Fast and efficient extraction and determination of nonsteroidal anti-inflammatory drugs using poly(8-hydroxyquinoline)-coated magnetic graphene oxide nanocomposite prior to capillary electrophoresis analysis in wastewater, breast milk, and urine samples. Electrophoresis 2024; 45:1701-1714. [PMID: 39076068 DOI: 10.1002/elps.202400023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 06/29/2024] [Accepted: 07/14/2024] [Indexed: 07/31/2024]
Abstract
In this study, magnetic graphene oxide coated with poly(8-hydroxyquinoline) was successfully synthesized, characterized, and utilized as a novel sorbent for the ultrasonic-assisted dispersive magnetic solid-phase extraction of naproxen and ibuprofen. These analytes served as representative analytes for two nonsteroidal anti-inflammatory drugs in various real samples. Characterization techniques, such as IR, X-ray powder diffraction, field emission scanning electron microscopy, energy-dispersive X-ray-mapping, and Brunauer-Emmett-Teller (BET), were used to confirm the correctness synthesis and preparation of the nanocomposites. Effective parameters on the extraction efficiency were investigated to maximize the analytical performance of the developed method. The dynamic range (1-1000 µg L-1), coefficients of determination (R2 ≥ 0.997), the limits of detection (0.3-1.0 µg L-1), and limit of quantification (1.0-3.0 µg L-1), intra-day and inter-day precisions (3.5%-7.2%) were achieved. The method validation results showed extraction recovery ranging from 80.4% to 96.0% and preconcentration factors ranging from 137 to 140.
Collapse
Affiliation(s)
| | - Ali Reza Fakhari
- Faculty of Chemistry, Shahid Beheshti University, Tehran, I.R. IRAN
| |
Collapse
|
4
|
Bian Y, Liu T, Wang XJ, Zhang Y, Zhang F. Core-shell magnetic covalent organic polymer nanocomposites as an adsorbent for the extraction of flavonoids. Mikrochim Acta 2024; 191:498. [PMID: 39088087 DOI: 10.1007/s00604-024-06588-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2024] [Accepted: 07/23/2024] [Indexed: 08/02/2024]
Abstract
A novel 3D magnetic nanocomposite material based on covalent organic polymers was successfully synthesized and utilized as an efficient sorbent for magnetic solid-phase extraction. It exhibited a regular core-shell structure, large specific surface area, superior stability, and paramagnetism. To evaluate its extraction efficiency, six flavonoids were tested, demonstrating maximum adsorption capacities ranging from 90 to 218 mg/g. Additionally, the material exhibited remarkable reusability and mechanical stability, maintaining its original state over eight cycles with consistent recovery. An analytical strategy combining magnetic solid-phase extraction with high performance liquid chromatography and tandem mass spectrometry was developed for the determination of flavonoids in orange, honey, soybean, and Dioscorea bulbifera L. samples. The low limits of detection (0.01-0.1 ng/mL) and limits of quantification (0.05-0.5 ng/mL), as well as satisfactory recovery (80.4-114.8%), were obtained. The linear range started from the limits of quantification to 500 ng/mL with R2 ≥ 0.9929. These results suggest that the prepared adsorbent possesses excellent adsorption capabilities for flavonoids, highlighting its significant potential for detecting these compounds in complex sample matrices.
Collapse
Affiliation(s)
- Yu Bian
- Institute of Food Safety, Chinese Academy of Inspection and Quarantine, Beijing, 100176, China
- School of Traditional Chinese Materia Medica, Shenyang Pharmaceutical University, Shenyang, 110016, China
| | - Tong Liu
- Institute of Food Safety, Chinese Academy of Inspection and Quarantine, Beijing, 100176, China
| | - Xiu-Juan Wang
- Institute of Food Safety, Chinese Academy of Inspection and Quarantine, Beijing, 100176, China
- Key Laboratory of Food Quality and Safety for State Market Regulation, Beijing, 100176, China
| | - Yuan Zhang
- School of Pharmacy, China Medical University, Shenyang, 110122, China
| | - Feng Zhang
- Institute of Food Safety, Chinese Academy of Inspection and Quarantine, Beijing, 100176, China.
- Key Laboratory of Food Quality and Safety for State Market Regulation, Beijing, 100176, China.
| |
Collapse
|
5
|
Shahsavani A, Fakhari AR. Facile extraction and determination of organophosphorus pesticides using poly (8-hydroxyquinoline) functionalized magnetic multi-walled carbon nanotubes nanocomposite in water, fruits, and vegetables samples. Food Chem 2024; 447:138848. [PMID: 38458129 DOI: 10.1016/j.foodchem.2024.138848] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Revised: 02/20/2024] [Accepted: 02/21/2024] [Indexed: 03/10/2024]
Abstract
This study presents a dispersive micro-solid phase extraction (D-μ-SPE) approach for extracting and determining of two organophosphorus pesticides (OPPs), including diazinon and chlorpyrifos as model analytes in various samples. For this purpose, we synthesized, characterized, and utilized magnetic multi-walled carbon nanotubes coated with poly 8-hydroxyquinoline (MWCNTs/Fe3O4@PHQ) as a novel sorbent. The impact of various parameters, including sorbent type, sample pH, sample volume, sorbent amount, desorption solvent (type and volume), extraction time, and ionic strength on the extraction efficiency was investigated and optimized. Following the extraction, the desorbed pesticides in acetone were analyzed using gas chromatography with an FID detector. Under the optimized experimental conditions, the proposed method showed excellent linearity in the range of 3-1000 µg/L, low detection limit (0.9-1.5 µg/L), good relative recoveries (86-101.5 %), and high precision (RSD < 6.5 %). Finally, the applicability of this method was evaluated by analyzing the target OPPs in a variety of real samples, and obtained satisfactory results.
Collapse
Affiliation(s)
- Abolfath Shahsavani
- Faculty of Chemistry, Shahid Beheshti University, G. C., P.O. Box 198396-3113, Evin, Tehran, I.R. Iran
| | - Ali Reza Fakhari
- Faculty of Chemistry, Shahid Beheshti University, G. C., P.O. Box 198396-3113, Evin, Tehran, I.R. Iran.
| |
Collapse
|
6
|
Martínez-Pérez-Cejuela H, Gionfriddo E. Evolution of Green Sample Preparation: Fostering a Sustainable Tomorrow in Analytical Sciences. Anal Chem 2024; 96:7840-7863. [PMID: 38687329 DOI: 10.1021/acs.analchem.4c01328] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/02/2024]
Affiliation(s)
- H Martínez-Pérez-Cejuela
- Department of Chemistry, University at Buffalo, The State University of New York, Buffalo, New York 14260-3000, United States
| | - E Gionfriddo
- Department of Chemistry, University at Buffalo, The State University of New York, Buffalo, New York 14260-3000, United States
| |
Collapse
|
7
|
Shirani M, Faraji M, Rashidi Nodeh H, Akbari-adergani B, Sepahi S. An efficient deep eutectic magnetic nano gel for rapid ultrasound-assisted dispersive µ-solid phase extraction of residue of tetracyclines in food samples. JOURNAL OF FOOD SCIENCE AND TECHNOLOGY 2023; 60:2802-2812. [PMID: 37711576 PMCID: PMC10497477 DOI: 10.1007/s13197-023-05798-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Revised: 04/20/2023] [Accepted: 06/06/2023] [Indexed: 09/16/2023]
Abstract
In the present study, a magnetic nano gel as the sorbent which is the combination of octatonic acid: cumarin as eutectic solvent and Fe3O4@SiO2 was introduced as the sorbent in ultrasound-assisted dispersive µ-solid phase extraction process coupled with high performance liquid chromatography with photo diode array detector for simultaneous separation and determination of tetracyclines residues in food samples. FT-IR, SEM, VSM were used for the characterization of the synthetized magnetic nano gel. Under obtained optimum conditions, the obtained linear ranges were 1.5-500 (µg L-1), 2.5-750 (µg L-1), 2-750 (µg L-1), and 2.5-500 (µg L-1) for tetracycline, oxytetracycline, chlortetracycline, and doxycycline, respectively. Moreover, the below level of quantification (BLQ) (based on S/N = 3) of 0.47 µg L-1, 0.11 µg L-1, 0.85 µg L-1, 0.66 µg L-1, 0.81 µg L-1 and the limit of quantification (based on S/N = 10) of 1.61, 2.74, 2.23 (µg L-1), and 2.66 were achieved for tetracycline, oxytetracycline, chlortetracycline, and doxycycline, respectively. The intra-day and inter-day precision (%) of the procedure were less than 3.2 and 3.8, respectively. The recoveries over 95% confirmed high sufficiency of the proposed method for application in complex matrices such as honey, milk, and egg. Graphical abstract Supplementary Information The online version contains supplementary material available at 10.1007/s13197-023-05798-w.
Collapse
Affiliation(s)
- Mahboube Shirani
- Department of Chemistry, Faculty of Science, University of Jiroft, P. O. Box 7867161167, Jiroft, Iran
| | - Mohammad Faraji
- Research Group of Food, Halal and Agricultural Products, Research Department of Food Technology and Agricultural Products, Standard Research Institute (SRI), P.O. Box 31745-139, Karaj, Iran
| | - Hamid Rashidi Nodeh
- Department of Food Science and Technology, Faculty of Food Industry and Agriculture, Standard Research Institute, Karaj, Iran
| | - Behrouz Akbari-adergani
- Food and Drug Laboratory Research Center, Food and Drug Administration, Ministry of Health and Medical Education, Tehran, Islamic Republic of Iran
| | - Soheila Sepahi
- Laboratories of Food and Drug Control, Vice Chancellery for Food and Drug, Isfahan University of Medical Sciences, Isfahan, Iran
| |
Collapse
|
8
|
Bodaghabadi F, Amiri A, Mirzaei M. Magnetic solid-phase extraction of polycyclic aromatic hydrocarbons from water samples using magnetic carbon nanofiber/MIL-101(Cr) nanocomposites. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:5526-5534. [PMID: 37846501 DOI: 10.1039/d3ay01356a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2023]
Abstract
In this study, magnetic carbon nanofibers (Fe3O4@CNF) were modified with MIL-101(Cr) (Fe3O4@CNF@MIL-101) and used as sorbents for magnetic solid-phase extraction (MSPE) to extract polycyclic aromatic hydrocarbons (PAHs) from real water samples. Gas chromatography coupled with a flame ionization detector (GC-FID) was used for the determination of the PAHs. The effect of experimental variables on the extraction efficiency of PAHs was investigated and optimized. These variables include the quantity of sorbent, the kind and volume of the elution solvent, the duration of extraction and desorption, and the salt concentration. The linear range was found to be 0.01 to 200 ng mL-1 with correlation coefficients ranging from 0.9906 to 0.9931 after the effective extraction parameters were optimized. Its detection limits (LOD) were also calculated to be between 0.003 and 0.005 ng mL-1 (S/N = 3). The method's repeatability was tested at three different concentration levels (0.1, 1, and 10 ng mL-1), and relative standard deviations (RSDs%) were obtained in the range of 2.3 to 5.0%. Finally, using the MSPE-GC-FID method, PAHs were extracted from tap water, wastewater, seawater, and spring water samples. The relative recoveries were in the range of 95.7 to 99.8%.
Collapse
Affiliation(s)
- Faezeh Bodaghabadi
- Department of Chemistry, Faculty of Science, Ferdowsi University of Mashhad, Mashhad 9177948974, Iran.
| | - Amirhassan Amiri
- Department of Chemistry, Faculty of Science, Ferdowsi University of Mashhad, Mashhad 9177948974, Iran.
| | - Masoud Mirzaei
- Department of Chemistry, Faculty of Science, Ferdowsi University of Mashhad, Mashhad 9177948974, Iran.
- Khorasan Science and Technology Park (KSTP), 12th km of Mashhad-Quchan Road, Mashhad, 9185173911, Khorasan Razavi, Iran
| |
Collapse
|
9
|
Fathi AA, Afshar Mogaddam MR, Sorouraddin SM, Farajzadeh MA, Mohebbi A. Selective extraction of apixaban from plasma by dispersive solid-phase microextraction using magnetic metal organic framework combined with molecularly imprinted polymer nanocomposite. J Sep Sci 2023; 46:e2201055. [PMID: 37387553 DOI: 10.1002/jssc.202201055] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Revised: 06/14/2023] [Accepted: 06/16/2023] [Indexed: 07/01/2023]
Abstract
This research aims to synthesize a specific and efficient sorbent to use in the extraction of apixaban from human plasma samples and its determination by high-performance liquid chromatography-tandem mass spectrometry. High specific surface area of metal-organic framework, magnetic property of iron oxide nanoparticles, selectively of molecular imprinted polymer toward the analyte, and the combination of dispersive solid-phase extraction method with a sensitive analysis system provided an efficient analytical method. In this study, first, a molecularly imprinted polymer combined with magnetic metal organic framework nanocomposite was prepared and then characterized using different techniques. Then the sorbent particles were used for selective extraction of the analyte from plasma samples. The efficiency of the method was improved by optimizing effective parameters. According to the validation results, wide linear range (1.02-200 ng mL-1 ), acceptable coefficient of determination (0.9938), low limit of detection (0.32 ng mL-1 ) and limit of quantification (1.02 ng mL-1 ), high extraction recovery (78%), and good precision (relative standard deviations ≤ 2.9% for intra- (n = 6) and interday (n = 6) precisions) were obtainable using the proposed method. These outcomes showed the high potential of the proposed method for screening apixaban in the human plasma samples.
Collapse
Affiliation(s)
- Ali Akbar Fathi
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran
- Neurosciences Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Mohammad Reza Afshar Mogaddam
- Food and Drug Safety Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
- Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | | | - Mir Ali Farajzadeh
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran
- Engineering Faculty, Near East University, Nicosia, Turkey
| | - Ali Mohebbi
- Food and Drug Safety Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| |
Collapse
|
10
|
Barzin M, Pooladi M. Polyaniline-co-polyindole functionalized magnetic porous carbon derived from MIL-53(Fe) for separation/enrichment of nitrophenols pollutants before determination with high-performance liquid chromatography-ultraviolet detection. J Sep Sci 2023; 46:e2300193. [PMID: 37248655 DOI: 10.1002/jssc.202300193] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2023] [Revised: 05/17/2023] [Accepted: 05/20/2023] [Indexed: 05/31/2023]
Abstract
Herein, a novel polyaniline-co-polyindole functionalized magnetic porous carbon derived from MIL-53(Fe) was prepared and employed as an excellent nano-adsorbent to preconcentrate trace amounts of nitro-phenols in water and wastewater samples. Briefly, magnetic MIL-53(Fe) was synthesized by the addition of magnetite nanoparticles, terephthalic acid, and FeCl3 to the reaction medium. The magnetic MIL-53(Fe) was pyrolyzed under nitrogen protection to obtain a magnetic porous carbon nanocomposite, and finally, the nanomaterial was functionalized with polyaniline-co-polyindole via oxidation polymerization. The obtained nano-adsorbent was characterized via X-ray diffraction, Fourier-transform infrared spectroscopy, vibrating sample magnetometry, and transmission and scanning electron microscopies. After that, the fabricated nano-material was utilized as an excellent nano-adsorbent for the preconcentration of trace nitro-phenols (2-nitrophenol, 4-nitrophenol, and 2,4-dinitrophenol) in environmental water, and wastewater samples. The detection limits were obtained from 0.1 to 0.15 μg/L after performing the optimization process. The new method was in the range of 0.4-300 μg/L. The proposed method exhibited a good precision from 3.2% to 9.6% for within-day assay, and 5.2%-13.2% for between-day assay at three concentration levels (1, 50, and 250 μg/L). Eventually, this method was utilized to preconcentrate/determine the target analytes in three water, and wastewater samples, satisfactory (relative standard deviations, 5.4%-9.3%; relative recovery, 88%-109%).
Collapse
Affiliation(s)
- Mahnaz Barzin
- Department of Medicinal Chemistry, Pharmaceutical Science Branch, Islamic Azad University, Tehran, Iran
| | - Mohsen Pooladi
- Department of Chemistry, Karaj Branch, Islamic Azad University, Karaj, Iran
| |
Collapse
|
11
|
Mohseni SF, Manoochehri M, Afshar Taromi F. A novel poly(2-mercaptobenzothiazole) coated magnetic nanoadsorbent derived from ZIF-8 for preconcentration/determination of palladium and silver. RSC Adv 2022; 12:35849-35859. [PMID: 36545095 PMCID: PMC9752480 DOI: 10.1039/d2ra06193g] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2022] [Accepted: 12/02/2022] [Indexed: 12/23/2022] Open
Abstract
Herein, a novel poly(2-mercaptobenzothiazole) coated magnetic nanoadsorbent derived from zeolitic-imidazole framework-8 (ZIF-8) was synthesized and then employed for the extraction/preconcentration of trace amounts of palladium and silver in various real matrixes. In this way, magnetite was fabricated first, and then functionalized with tetraethyl orthosilicate. After that, the synthesized magnetite@silica was coated with the ZIF-8 to obtain magnetic ZIF-8. Afterward, the magnetic ZIF-8 was pyrolyzed under the protection of a nitrogen atmosphere to get a magnetic carbon nanoadsorbent. Finally, the magnetic carbon was functionalized with a conductive polymer (poly-2-mercaptobenzothiazole). Fabrication of the nanoadsorbent was affirmed with scanning and transmission electron microscopies, elemental analysis, X-ray diffraction, Fourier transform infrared spectroscopy, and vibrating sample magnetometry. The method is linear from 0.25 to 200 μg L-1 for silver, and from 0.5 to 250 μg L-1 for palladium. The detection limits are 0.07 and 0.15 μg L-1 for Ag and Pd, respectively. The precision was evaluated at three concentration levels (1, 75, 200 μg L-1, n = 5) and all the relative standard deviation (RSD) values were lower than 10.3%. In the end, the new method was utilized for the preconcentration/determination of trace amounts of palladium and silver in various real matrixes, satisfactorily (relative recovery: 86% to 104%; RSD%: 4.0-9.5%).
Collapse
Affiliation(s)
- Seyedeh Fatemeh Mohseni
- Department of Chemistry, Central Tehran Branch, Islamic Azad University1467686831TehranIran+98 2188385798+98 9127242698
| | - Mahboobeh Manoochehri
- Department of Chemistry, Central Tehran Branch, Islamic Azad University1467686831TehranIran+98 2188385798+98 9127242698
| | - Faramarz Afshar Taromi
- Department of Polymer Engineering and Color Technology, Amirkabir University of Technology424 Hafez Avenue, P. O. Box: 15875-4413TehranIran
| |
Collapse
|
12
|
Haghighat H. A new magnetic metal–organic framework composite synthesized via a post-synthetic functionalization approach for ultra-trace extraction/determination of mercury in real matrixes. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107770] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
13
|
Shaban M, Hayadokht H, Hanaee J, Jahanbeen Sardroudi J, Entezari-Maleki T, Soltani S. Synthesis, characterization, and the investigation of the applicability of citric acid functionalized Fe2O3 nanoparticles for the extraction of carvedilol from human plasma using DFT calculations and clinical samples analysis. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107398] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
14
|
Yilmaz E, Sarp G, Uzcan F, Ozalp O, Soylak M. Application of magnetic nanomaterials in bioanalysis. Talanta 2021; 229:122285. [PMID: 33838779 DOI: 10.1016/j.talanta.2021.122285] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 02/04/2021] [Accepted: 02/26/2021] [Indexed: 12/21/2022]
Abstract
The importance of magnetic nanomaterials and magnetic hybrid materials, which are classified as new generation materials, in analytical applications is increasingly understood, and research on the adaptation of these materials to analytical methods has gained momentum. Development of sample preparation techniques and sensor systems using magnetic nanomaterials for the analysis of inorganic, organic and biomolecules in biological samples, which are among the samples that analytical chemists work on most, are among the priority issues. Therefore in this review, we focused on the use of magnetic nanomaterials for the bioanalytical applications including inorganic and organic species and biomolecules in different biological samples such as primarily blood, serum, plasma, tissue extracts, urine and milk. We summarized recent progresses, prevailing techniques, applied formats, and future trends in sample preparation-analysis methods and sensors based on magnetic nanomaterials (Mag-NMs). First, we provided a brief introduction of magnetic nanomaterials, especially their magnetic properties that can be utilized for bioanalytical applications. Second, we discussed the synthesis of these Mag-NMs. Third, we reviewed recent advances in bioanalytical applications of the Mag-NMs in different formats. Finally, recently literature studies on the relevance of Mag-NMs for bioanalysis applications were presented.
Collapse
Affiliation(s)
- Erkan Yilmaz
- Department of Analytical Chemistry, Faculty of Pharmacy, Erciyes University, Kayseri, Turkey; Technology Research and Application Center (TAUM), Erciyes University, Kayseri, Turkey; ERNAM-Nanotechnology Application and Research Center, Erciyes University, Kayseri, Turkey
| | - Gokhan Sarp
- Department of Analytical Chemistry, Faculty of Pharmacy, Erciyes University, Kayseri, Turkey; Technology Research and Application Center (TAUM), Erciyes University, Kayseri, Turkey; ERNAM-Nanotechnology Application and Research Center, Erciyes University, Kayseri, Turkey
| | - Furkan Uzcan
- Technology Research and Application Center (TAUM), Erciyes University, Kayseri, Turkey; Department of Chemistry, Faculty of Sciences, Erciyes University, Kayseri, Turkey
| | - Ozgur Ozalp
- Technology Research and Application Center (TAUM), Erciyes University, Kayseri, Turkey; Department of Chemistry, Faculty of Sciences, Erciyes University, Kayseri, Turkey
| | - Mustafa Soylak
- Technology Research and Application Center (TAUM), Erciyes University, Kayseri, Turkey; Department of Chemistry, Faculty of Sciences, Erciyes University, Kayseri, Turkey.
| |
Collapse
|
15
|
Xu X, Feng X, Liu Z, Xue S, Zhang L. 3D flower-liked Fe 3O 4/C for highly sensitive magnetic dispersive solid-phase extraction of four trace non-steroidal anti-inflammatory drugs. Mikrochim Acta 2021; 188:52. [PMID: 33496871 DOI: 10.1007/s00604-021-04708-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Accepted: 01/10/2021] [Indexed: 10/22/2022]
Abstract
A low cost-effective and simple synthesis method was adopted to acquire three-dimensional flower-like structure Fe3O4/C that has large specific area, suitable pore structure and sufficient saturation magnetism. The obtained Fe3O4/C exhibits outstanding preconcentration ability and was applied to extracting non-steroidal anti-inflammatory drugs from complex environmental and biological samples. The parameters of magnetic solid-phase extraction were optimized by univariate and multivariate methods (Box-Behnken design). The high degree of linearity from 2.5 to 1000.0 ng mL-1 (R2 ≥ 0.9976), the limits of detection from 0.25 to 0.5 ng mL- 1 (S/N = 3), and the limits of quantitation from 1.0 to 2.0 ng mL- 1 (S/N = 10) were yielded by adopting this novel method after the optimization. Moreover, the recoveries of non-steroidal anti-inflammatory drugs from 89.6 to 107.0% were acquired in spiked plasma, urine and lake samples. In addition, the adsorption of non-steroidal anti-inflammatory drugs on Fe3O4/C was explored by adsorption isotherms and kinetic studies. Furthermore, the adsorption mechanism for non-steroidal anti-inflammatory drugs by Fe3O4/C was proposed, which was hydrogen bonding and π-π interaction between non-steroidal anti-inflammatory drugs and Fe3O4/C. Graphical abstract.
Collapse
Affiliation(s)
- Xu Xu
- College of Chemistry, Liaoning University, 66 Chongshan Middle Road, Shenyang, 110036, People's Republic of China.
| | - Xue Feng
- College of Chemistry, Liaoning University, 66 Chongshan Middle Road, Shenyang, 110036, People's Republic of China
| | - Zhen Liu
- College of Chemistry, Liaoning University, 66 Chongshan Middle Road, Shenyang, 110036, People's Republic of China
| | - Shan Xue
- College of Chemistry, Liaoning University, 66 Chongshan Middle Road, Shenyang, 110036, People's Republic of China
| | - Lei Zhang
- College of Chemistry, Liaoning University, 66 Chongshan Middle Road, Shenyang, 110036, People's Republic of China.
| |
Collapse
|
16
|
Gutiérrez-Serpa A, González-Martín R, Sajid M, Pino V. Greenness of magnetic nanomaterials in miniaturized extraction techniques: A review. Talanta 2020; 225:122053. [PMID: 33592775 DOI: 10.1016/j.talanta.2020.122053] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Revised: 12/16/2020] [Accepted: 12/17/2020] [Indexed: 12/20/2022]
Abstract
Green analytical chemistry principles should be followed, as much as possible, and particularly during the development of analytical sample preparation methods. In the past few years, outstanding materials such as ionic liquids, metal-organic frameworks, carbonaceous materials, molecularly imprinted materials, and many others, have been introduced in a wide variety of miniaturized techniques in order to reduce the amount of solvents and sorbents required during the analytical sample preparation step while pursuing more efficient extraction methods. Among them, magnetic nanomaterials (MNMs) have gained special attention due to their versatile properties. Mainly, their ability to be separated from the sample matrix using an external magnetic field (thus enormously simplifying the entire process) and their easy combination with other materials, which implies the inclusion of a countless number of different functionalities, highly specific in some cases. Therefore, MNMs can be used as sorbents or as magnetic support for other materials which do not have magnetic properties, the latter permiting their combination with novel materials. The greenness of these magnetic sorbents in miniaturized extractions techniques is generally demonstrated in terms of their ease of separation and amount of sorbent required, while the nature of the material itself is left unnoticed. However, the synthesis of MNMs is not always as green as their applications, and the resulting MNMs are not always as safe as desired. Is the analytical sample preparation field ready for using green magnetic nanomaterials? This review offers an overview, from a green analytical chemistry perspective, of the current state of the use of MNMs as sorbents in microextraction strategies, their preparation, and the analytical performance offered, together with a critical discussion on where efforts should go.
Collapse
Affiliation(s)
- Adrián Gutiérrez-Serpa
- Departamento de Química, Unidad Departamental de Química Analítica, Universidad de La Laguna (ULL), La Laguna, Tenerife, 38206, Spain; Instituto Universitario de Enfermedades Tropicales y Salud Pública de Canarias, Universidad de La Laguna (ULL), La Laguna, Tenerife, 38206, Spain
| | - Raúl González-Martín
- Departamento de Química, Unidad Departamental de Química Analítica, Universidad de La Laguna (ULL), La Laguna, Tenerife, 38206, Spain
| | - Muhammad Sajid
- Center for Environment and Water, Research Institute, King Fahd University of Petroleum and Minerals, Dhahran, 31261, Saudi Arabia
| | - Verónica Pino
- Departamento de Química, Unidad Departamental de Química Analítica, Universidad de La Laguna (ULL), La Laguna, Tenerife, 38206, Spain; Instituto Universitario de Enfermedades Tropicales y Salud Pública de Canarias, Universidad de La Laguna (ULL), La Laguna, Tenerife, 38206, Spain.
| |
Collapse
|
17
|
Hu K, Cheng J, Zhang W, Pang T, Wu X, Zhang Z, Huang Y, Zhao W, Zhang S. Simultaneous extraction of diverse organic pollutants from environmental water using a magnetic covalent organic framework composite. Anal Chim Acta 2020; 1140:132-144. [DOI: 10.1016/j.aca.2020.10.019] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Revised: 10/08/2020] [Accepted: 10/14/2020] [Indexed: 12/17/2022]
|
18
|
Simultaneous extraction of chromium and cadmium from bean samples by SrFe12O19@CTAB magnetic nanoparticles and determination by ETAAS: An experimental design methodology. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105588] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
19
|
Arcoleo A, Bianchi F, Careri M. Helical multi-walled carbon nanotube-coated fibers for solid-phase microextraction determination of polycyclic aromatic hydrocarbons at ultra-trace levels in ice and snow samples. J Chromatogr A 2020; 1631:461589. [PMID: 33022570 DOI: 10.1016/j.chroma.2020.461589] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2020] [Revised: 09/15/2020] [Accepted: 09/28/2020] [Indexed: 01/09/2023]
Abstract
Polycyclic Aromatic Hydrocarbons (PAHs) detected in polar environment are recognized tracers of anthropogenic pollution. High sensitivity and selectivity are required for their analysis in ice and snow samples due to the presence at ultra-trace levels. In this study a solid-phase microextraction (SPME) gas chromatography-mass spectrometry (GC-MS) method for simultaneous determination of the 16 US-EPA priority pollutant PAHs in polar snow and ice samples was developed and validated. Helical multiwalled carbon nanotubes (HMWCNTs) were proposed for the first time as novel SPME coating. For optimization purposes a Central Composite Design and the multicriteria method of the desirability functions were applied to investigate the influence of extraction parameters, i.e. time and temperature as main factors. The optimal values were 68 °C for the extraction temperature and 60 min for the extraction time. The developed SPME-GC-MS method exhibited detection limits of 16 PAHs in the 0.1-1.2 ng/L range, a repeatability and an intermediate precision within 15% and 22% relative standard deviation, respectively, and good recovery rates in the 93.7 (± 0.1)-119.7 (± 0.2)% range for real spiked water sample, showing better analytical performance compared to commercial PDMS fibers. Enrichment factors in the 2670 (± 290)-142120 (± 580) range were calculated and a long fiber shelf-life with the possibility to reuse the fiber more than 200 times was achieved. Finally, the proposed method was successfully applied to the determination of PAHs in surface snow samples collected in April 2019 at Ny-Ålesund, Svalbard. Its application to the detection of PAHs in samples collected during monitoring campaigns in the polar regions is expected in the near future.
Collapse
Affiliation(s)
- Angela Arcoleo
- Dipartimento di Scienze Chimiche, della Vita e della Sostenibilità Ambientale, Università di Parma, Parco Area delle Scienze 17/A, 43124 Parma, Italy
| | - Federica Bianchi
- Dipartimento di Scienze Chimiche, della Vita e della Sostenibilità Ambientale, Università di Parma, Parco Area delle Scienze 17/A, 43124 Parma, Italy
| | - Maria Careri
- Dipartimento di Scienze Chimiche, della Vita e della Sostenibilità Ambientale, Università di Parma, Parco Area delle Scienze 17/A, 43124 Parma, Italy.
| |
Collapse
|
20
|
Ghorbani M, Aghamohammadhassan M, Ghorbani H, Zabihi A. Trends in sorbent development for dispersive micro-solid phase extraction. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105250] [Citation(s) in RCA: 53] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
21
|
Amine-functionalized magnetic activated carbon as an adsorbent for preconcentration and determination of acidic drugs in environmental water samples using HPLC-DAD. OPEN CHEM 2020. [DOI: 10.1515/chem-2020-0162] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023] Open
Abstract
AbstractIn the present study, a convenient and highly effective method was developed for the quantification of acidic drugs in wastewater and river water samples. Ultrasonic-assisted magnetic solid phase extraction employing magnetic waste tyre-based activated carbon nanocomposite functionalized with [3-(2-aminoethylamino)propyl]trimethoxysilane as a cost-effective and efficient adsorbent was used for the extraction and preconcentration of acidic drugs (naproxen [NAP], ketoprofen (KET) and diclofenac [DIC]). The quantification of target analytes was achieved by high‐performance liquid chromatography with diode array detector. Under optimum conditions, the detection limit, quantification limit and relative standard deviation obtained for the analytes of interest ranged from 0.38 to 0.76, 1.26 to 2.54 µg L−1 and 2.02 to 4.06%, respectively. The applicability of the developed method was assessed by the spike recovery tests and the relative recoveries proved that the method is reliable for the determination of acidic drugs in wastewater. Thereafter, the method was applied successfully for the determination of NAP, KET and DIC in river water, influent and effluent wastewater.
Collapse
|
22
|
Sabeghi MB, Ghasempour HR, Koohi MK, Karimi N. Synthesis and application of a novel functionalized magnetic MIL-101(Cr) nanocomposite for determination of aflatoxins in pistachio samples. RESEARCH ON CHEMICAL INTERMEDIATES 2020. [DOI: 10.1007/s11164-020-04194-9] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
|
23
|
Chu C, Li J, Wang S, Weng L, Jiang L, Zhang H, Liu C, Yan J. A Simple and Sensitive Dispersive Micro-Solid-Phase Extraction Coupled with High-Performance Liquid Chromatography for Quantification of Honokiol and Magnolol in Complex Matrices. J AOAC Int 2020; 103:1406-1411. [DOI: 10.1093/jaoacint/qsaa049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2019] [Revised: 03/24/2020] [Accepted: 04/03/2020] [Indexed: 11/14/2022]
Abstract
Abstract
Background
Honokiol and magnolol were considered as markers for the analysis of Cortex Magnoliae Officinalis, its related Chinese Patent Medicines and their metabolites. However, the determination of these two analytes in a water-soluble sample is difficult and therefore requires a more efficient method.
Objective
To develop a sensitive method for the determination of honokiol and magnolol in a water-soluble sample for better quality control of Cortex Magnoliae Officinalis and its related Chinese Patent Medicines.
Method
In this work, a combination of dispersive micro-solid-phase extraction (DMSPE) and high-performance liquid chromatography (HPLC) has been developed for simultaneous preconcentration and determination of honokiol and magnolol in complex bio-samples. Several experimental factors affecting the extraction efficiency were optimized by single factor test.
Results
Under the optimized extraction conditions, the proposed method exhibited good linearity of not less than 0.9998, satisfactory precision with relative standard deviation of less than 1.3%, and acceptable mean recoveries of 97.3% and 101.5% for honokiol and magnolol, respectively. Furthermore, the method exhibits extremely high sensitivity with detection limits of 0.0097 and 0.0231 ng/mL, which is even more sensitive than those methods developed by MS.
Conclusions
The method established in this study is fast, economic, accurate, easy to operate, and importantly well suited to the extraction and analysis of honokiol and magnolol in a real complex sample matrix.
Collapse
Affiliation(s)
- Chu Chu
- College of Pharmaceutical Science, Zhejiang University of Technology, Hangzhou, People's Republic of China
| | - Jing Li
- College of Pharmaceutical Science, Zhejiang University of Technology, Hangzhou, People's Republic of China
| | - Shan Wang
- College of Pharmaceutical Science, Zhejiang University of Technology, Hangzhou, People's Republic of China
| | - Lvnan Weng
- College of Pharmaceutical Science, Zhejiang University of Technology, Hangzhou, People's Republic of China
| | - Luyi Jiang
- College of Pharmaceutical Science, Zhejiang University of Technology, Hangzhou, People's Republic of China
| | - Huan Zhang
- College of Pharmaceutical Science, Zhejiang University of Technology, Hangzhou, People's Republic of China
| | - Caijing Liu
- College of Pharmaceutical Science, Zhejiang University of Technology, Hangzhou, People's Republic of China
| | - Jizhong Yan
- College of Pharmaceutical Science, Zhejiang University of Technology, Hangzhou, People's Republic of China
| |
Collapse
|
24
|
Preparation of electrospun polyacrylonitrile/Ni-MOF-74 nanofibers for extraction of atenolol and captopril prior to HPLC-DAD. Mikrochim Acta 2020; 187:508. [DOI: 10.1007/s00604-020-04483-5] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2020] [Accepted: 08/05/2020] [Indexed: 12/31/2022]
|
25
|
Rahimpour E, Alvani-Alamdari S, Jouyban A. A Comprehensive Review on Developed Pharmaceutical Analysis Methods by Iranian Analysts in 2018. PHARMACEUTICAL SCIENCES 2020. [DOI: 10.34172/ps.2020.10] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
This article summarizes the publishing activities including bioanalytical and pharmaceutical analyses researches carried out in Iran in 2018 in order to connect academic researchers to those in industry, medical care units and hospitals. A wide spectrum of analytical methods has been used to determine and/or evaluate drug levels in the biological samples, based on physical, chemical and biochemical principles. We have compiled a concise survey of the literature covering 125 reports and tabulated the relevant analytical parameters. Chromatographic and electrochemical methods were found to be the technique of choice for many workers and almost 83% studies were performed by using these methods. This is the first annual review of the literature searching in SCOPUS database for published bioanalytical and pharmaceutical analysis researches in Iran.
Collapse
Affiliation(s)
- Elaheh Rahimpour
- harmaceutical Analysis Research Center and Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
- Food and Drug Safety Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Sima Alvani-Alamdari
- Biotechnology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Abolghasem Jouyban
- harmaceutical Analysis Research Center and Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
- Digestive Diseases Research Institute, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
26
|
Fontanals N, Borrull F, Marcé RM. Overview of mixed-mode ion-exchange materials in the extraction of organic compounds. Anal Chim Acta 2020; 1117:89-107. [DOI: 10.1016/j.aca.2020.03.053] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2020] [Revised: 03/25/2020] [Accepted: 03/26/2020] [Indexed: 12/18/2022]
|
27
|
Guo X, Li Y, Zhang B, Yang L, Di X, Di X. Development of dispersive solid phase extraction based on dissolvable Fe3O4-layered double hydroxide for high-performance liquid chromatographic determination of phenoxy acid herbicides in water samples. Microchem J 2020. [DOI: 10.1016/j.microc.2019.104443] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
28
|
Preparation of magnetite/multiwalled carbon nanotubes/metal-organic framework composite for dispersive magnetic micro solid phase extraction of parabens and phthalate esters from water samples and various types of cream for their determination with liquid chromatography. J Chromatogr A 2019; 1608:460426. [DOI: 10.1016/j.chroma.2019.460426] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Revised: 07/30/2019] [Accepted: 08/03/2019] [Indexed: 01/20/2023]
|
29
|
Nazari N, Masrournia M, Es'haghi Z, Bozorgmehr M. Magnetite‐graphene oxide sheets as support for hemimicelles/admicelles based microextraction of acidic, basic and neutral compounds prior to gas chromatography determination. SEPARATION SCIENCE PLUS 2019. [DOI: 10.1002/sscp.201900051] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Affiliation(s)
- Najmeh Nazari
- Department of ChemistryFaculty of Sciences, Mashhad BranchIslamic Azad University Mashhad Iran
| | - Mahboubeh Masrournia
- Department of ChemistryFaculty of Sciences, Mashhad BranchIslamic Azad University Mashhad Iran
| | | | | |
Collapse
|
30
|
Maciel EVS, de Toffoli AL, Neto ES, Nazario CED, Lanças FM. New materials in sample preparation: Recent advances and future trends. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.115633] [Citation(s) in RCA: 46] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
31
|
|
32
|
A nanosized magnetic metal-organic framework of type MIL-53(Fe) as an efficient sorbent for coextraction of phenols and anilines prior to their quantitation by HPLC. Mikrochim Acta 2019; 186:597. [PMID: 31375929 DOI: 10.1007/s00604-019-3698-9] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2019] [Accepted: 07/13/2019] [Indexed: 10/26/2022]
Abstract
The authors describe the synthesis of a magnetic metal-organic framework (MOF) of type MIL-53(Fe) for coextraction of phenols and anilines from various environmental samples. A quick method for dispersive micro-solid phase extraction (D-μ-SPE) was developed for coextraction of the analytes 4-nitrophenol (4-NP), 4-chlorophenol (4-CP), 4-chloroaniline (4-CA), 1-amino-2-naphtol (1-A2N) and 2, 4-dichloroaniline (2, 4-DCA). The MOF was characterized by SEM, TEM, FT-IR, EDS, thermogravimetry, VSM and XRD. The method was optimized by response surface methodology combined with desirability function approach, specifically with respect to pH value of the sample, amount of sorbent, sorption time, salt concentration, sample volume, type and volume of the eluent, and elution time. Following elution with acetonitrile, the analytes were quantified by HPLC with photodiode array detection. Responses are linear in 0.1-2000 μg·L-1 concentration ranges. The limits of detection and relative standard deviations (for n = 5) are in the range of 0.03-0.2 μg·L-1 and 3.5-12.6%, respectively. Enrichment factors are 113, 61, 87, 144 and 114 for 4-NP, 4-CP, 4-CA, 1-A2N and 2,4-DCA, respectively. Recoveries from spiked samples ranged from 39.5 to 93.3%. The magnetic sorbent was successfully applied to the coextraction and determination of the analytes in river, rain and hookah water samples. Graphical abstract Schematic presentation for the synthesis of (a) Fe3O4 nanoparticles (NPs) and (b) Fe3O4@MIL-53(Fe). Fe3O4@MIL-53(Fe) was employed as a new nanosorbent in dispersive micro-solid phase extraction of phenols and anilines. The limits of detection are in the range of 0.03-0.2 μg·L-1.
Collapse
|
33
|
Dispersive micro-solid phase extraction using magnetic ZnFe2O4 nanotubes as adsorbent for preconcentration of Co(II), Ni(II), Mn(II) and Cd(II) followed by ICP-MS determination. Microchem J 2019. [DOI: 10.1016/j.microc.2019.02.066] [Citation(s) in RCA: 42] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
34
|
Liu Y, Guo L, Huang H, Dou J, Huang Q, Gan D, Chen J, Li Y, Zhang X, Wei Y. Facile preparation of magnetic composites based on carbon nanotubes: Utilization for removal of environmental pollutants. J Colloid Interface Sci 2019; 545:8-15. [DOI: 10.1016/j.jcis.2019.03.009] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2019] [Revised: 02/28/2019] [Accepted: 03/04/2019] [Indexed: 10/27/2022]
|
35
|
Chen S, Yan J, Li J, Lu D. Magnetic ZnFe2O4 nanotubes for dispersive micro solid-phase extraction of trace rare earth elements prior to their determination by ICP-MS. Mikrochim Acta 2019; 186:228. [DOI: 10.1007/s00604-019-3342-8] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2018] [Accepted: 02/27/2019] [Indexed: 12/12/2022]
|
36
|
Asfaram A, Sadeghi H, Goudarzi A, Panahi Kokhdan E, Salehpour Z. Ultrasound combined with manganese-oxide nanoparticles loaded on activated carbon for extraction and pre-concentration of thymol and carvacrol in methanolic extracts of Thymus daenensis, Salvia officinalis, Stachys pilifera, Satureja khuzistanica, and mentha, and water samples. Analyst 2019; 144:1923-1934. [DOI: 10.1039/c8an02338g] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
A dispersive micro solid-phase extraction (DMSPE) technique was developed using manganese-oxide nanoparticles loaded on activated carbon (Mn3O4-NPs-AC) as an effective sorbent combined with ultrasound for the extraction and determination of a trace amount of thymol and carvacrol in methanolic extracts of Thymus daenensis, Salvia officinalis, Stachys pilifera, Satureja khuzistanica and mentha, and water samples.
Collapse
Affiliation(s)
- Arash Asfaram
- Medicinal Plants Research Center
- Yasuj University of Medical Sciences
- Yasuj
- Iran
| | - Hossein Sadeghi
- Medicinal Plants Research Center
- Yasuj University of Medical Sciences
- Yasuj
- Iran
| | - Alireza Goudarzi
- Department of Polymer Engineering
- Golestan University
- Gorgan 49188-88369
- Iran
| | | | - Zeinab Salehpour
- Medicinal Plants Research Center
- Yasuj University of Medical Sciences
- Yasuj
- Iran
| |
Collapse
|
37
|
Moradi Z, Alipanahpour Dil E, Asfaram A. Dispersive micro-solid phase extraction based on Fe3O4@SiO2@Ti-MOF as a magnetic nanocomposite sorbent for the trace analysis of caffeic acid in the medical extracts of plants and water samples prior to HPLC-UV analysis. Analyst 2019; 144:4351-4361. [DOI: 10.1039/c9an00120d] [Citation(s) in RCA: 54] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
In this work, Fe3O4@SiO2@Ti-MOF-NCs, as an efficient sorbent, have been synthesized in a laboratory and utilized for extracting CA in the medical extracts of plants and water samples before their analysis by HPLC.
Collapse
Affiliation(s)
- Zohreh Moradi
- Department of Chemistry
- Yasouj University
- Yasouj 75918-74831
- Iran
| | | | - Arash Asfaram
- Medicinal Plants Research Center
- Yasuj University of Medical Sciences
- Yasuj
- Iran
| |
Collapse
|