1
|
Yin C, Liu Y, Hu T, Chen X. Graphitic Carbon Nitride Nanomaterials-Based Electrochemical Sensing Interfaces for Monitoring Heavy Metal Ions in Aqueous Environments. NANOMATERIALS (BASEL, SWITZERLAND) 2025; 15:564. [PMID: 40214609 PMCID: PMC11990414 DOI: 10.3390/nano15070564] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/10/2025] [Revised: 04/02/2025] [Accepted: 04/03/2025] [Indexed: 04/14/2025]
Abstract
The persistent threat of heavy metal ions (e.g., Pb2+, Hg2+, Cd2+) in aqueous environments to human health underscores an urgent need for advanced sensing platforms capable of rapid and precise pollutant monitoring. Graphitic carbon nitride (g-C3N4), a metal-free polymeric semiconductor, has emerged as a revolutionary material for constructing next-generation environmental sensors due to its exceptional physicochemical properties, including tunable electronic structure, high chemical/thermal stability, large surface area, and unique optical characteristics. This review systematically explores the integration of g-C3N4 with functional nanomaterials (e.g., metal nanoparticles, metal oxide nanomaterials, carbonaceous materials, and conduction polymer) to engineer high-performance sensing interfaces for heavy metal detection. The structure-property relationship is critically analyzed, emphasizing how morphology engineering (nanofibers, nanosheets, and mesoporous) and surface functionalization strategies enhance sensitivity and selectivity. Advanced detection mechanisms are elucidated, including electrochemical signal amplification, and photoinduced electron transfer processes enabled by g-C3N4's tailored bandgap and surface active sites. Furthermore, this review addresses challenges in real-world deployment, such as scalable nanomaterial synthesis, matrix interference mitigation, and long-term reliable detection. This work provides valuable insights for advancing g-C3N4-based electrochemical sensing technologies toward sustainable environmental monitoring and intelligent pollution control systems.
Collapse
Affiliation(s)
- Cheng Yin
- School of Resources and Environmental Engineering, Anhui Water Conservancy Technical College, Hefei 231603, China;
| | - Yao Liu
- School of Resources and Environmental Engineering, Hefei University of Technology, Hefei 230009, China;
| | - Tingting Hu
- School of Resources and Environmental Engineering, Hefei University of Technology, Hefei 230009, China;
| | - Xing Chen
- School of Resources and Environmental Engineering, Hefei University of Technology, Hefei 230009, China;
- Key Lab of Aerospace Structural Parts Forming Technology and Equipment of Anhui Province, Institute of Industry and Equipment Technology, Hefei University of Technology, Hefei 230009, China
| |
Collapse
|
2
|
Huang Z, Yang G, Deng Q, Zhang X, Wei X, Li J. A molecularly imprinted electrochemiluminescence sensor based on mimic enzyme ZIF-90 and MnO 2/g-C 3N 4 magnetic particles for detection of methidathion. Mikrochim Acta 2024; 191:678. [PMID: 39420129 DOI: 10.1007/s00604-024-06753-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2024] [Accepted: 09/28/2024] [Indexed: 10/19/2024]
Abstract
Methidathion (MTDT), a common organophosphorus pesticide with high insecticidal activity, is widely used for pest control. However, the misuse of MTDT leads to widespread residues and endangers human health. Therefore, it is crucial to develop a simple and highly sensitive method for the detection of MTDT residues. Herein, ZIF-90/MnO2/g-C3N4/Fe3O4 composite particles were synthesized: The MnO2 nanosheets could absorb the energy of the excited g-C3N4 to quench the ECL of g-C3N4 while ZIF-90 acted as a mimetic enzyme to catalyze the formation of thiocholine from MTDT. The thiocholine caused the reduction of MnO2 to Mn2+, restoring the ECL signal of g-C3N4. Combined with molecular imprinting technique, an electrochemiluminescence sensor was constructed for the determination of MTDT. The determination range was 1.00 × 10-9 ~ 7.00 × 10-7 g/L, and the detection limit was 6.58 × 10-10 g/L. Structurally similar organophosphorus pesticides showed no cross-reactivity. The method has high sensitivity and specificity, and has been successfully applied to the determination of MTDT residue in fruits with recoveries in the range 93.75% ~ 102.37%.
Collapse
Affiliation(s)
- Ziyu Huang
- College of Chemistry and Bioengineering, Guilin University of Technology, Guangxi, 541004, China
| | - Guangwei Yang
- College of Environmental Science and Engineering, Guilin University of Technology, Guilin, 541004, China
| | - Qiuling Deng
- College of Chemistry and Bioengineering, Guilin University of Technology, Guangxi, 541004, China
| | - Xuhui Zhang
- College of Chemistry and Bioengineering, Guilin University of Technology, Guangxi, 541004, China
| | - Xiaoping Wei
- College of Chemistry and Bioengineering, Guilin University of Technology, Guangxi, 541004, China.
| | - Jianping Li
- College of Chemistry and Bioengineering, Guilin University of Technology, Guangxi, 541004, China.
- College of Environmental Science and Engineering, Guilin University of Technology, Guilin, 541004, China.
| |
Collapse
|
3
|
Jian K, Fu L, Zhang Y, Zhang H, Guo X, Zhao X. Microwave synthesis of chitosan-based carbon dots for Al 3+ detection and biological application. Int J Biol Macromol 2024; 260:129413. [PMID: 38262835 DOI: 10.1016/j.ijbiomac.2024.129413] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2023] [Revised: 12/28/2023] [Accepted: 01/09/2024] [Indexed: 01/25/2024]
Abstract
Yellow fluorescent carbon dots (Y-CDs) were prepared via microwave method using chitosan and o-phenylenediamine as the main raw materials. The obtained Y-CDs possesses good water solubility, excellent biocompatibility and luminous stability. During the microwave pyrolysis carbonization process, the surface of Y-CDs was modified with the functional groups such as amino and carboxyl, which can bind to Al3+ by forming complexes, further improving the selectivity and sensitivity of the Al3+ detection. And the fluorescence of Y-CDs was quenched by Al3+ by static quenching process. More importantly, Y-CDs as fluorescent sensor was further applied for the determination of Al3+ in the real water samples with high reliability and accuracy. In addition, Y-CDs present potential application in biological imaging. The cultivated zebrafish embryos with Y-CDs displayed clearly in vivo uptake and metabolic fluorescence images, further confirming its low toxicity and excellent biocompatibility.
Collapse
Affiliation(s)
- Ke Jian
- School of Chemistry and Chemical Engineering, Qingdao University, Qingdao 266071, China
| | - Liming Fu
- School of Chemistry and Chemical Engineering, Qingdao University, Qingdao 266071, China
| | - Yujie Zhang
- School of Chemistry and Chemical Engineering, Qingdao University, Qingdao 266071, China
| | - Hongmei Zhang
- School of Chemistry and Chemical Engineering, Qingdao University, Qingdao 266071, China
| | - Xiangjun Guo
- School of Chemistry and Chemical Engineering, Qingdao University, Qingdao 266071, China
| | - Xihui Zhao
- School of Chemistry and Chemical Engineering, Qingdao University, Qingdao 266071, China; State Key Laboratory of Bio-fibers and Eco-textiles and Ecological Textiles, Institute of Marine Biobased Materials, Qingdao University, Qingdao 266071, China.
| |
Collapse
|
4
|
Xhanari K, Finšgar M. Recent advances in the modification of electrodes for trace metal analysis: a review. Analyst 2023; 148:5805-5821. [PMID: 37697964 DOI: 10.1039/d3an01252b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/13/2023]
Abstract
This review paper summarizes the research published in the last five years on using different compounds and/or materials as modifiers for electrodes employed in trace heavy metal analysis. The main groups of modifiers are identified, and their single or combined application on the surface of the electrodes is discussed. Nanomaterials, film-forming substances, and polymers are among the most used compounds employed mainly in the modification of glassy carbon, screen-printed, and carbon paste electrodes. Composites composed of several compounds and/or materials have also found growing interest in the development of modified electrodes. Environmentally friendly substances and natural products (mainly biopolymers and plant extracts) have continued to be included in the modification of electrodes for trace heavy metal analysis. The main analytical performance parameters of the modified electrodes as well as possible interferences affecting the determination of the target analytes, are discussed. Finally, a critical evaluation of the main findings from these studies and an outlook discussing possible improvements in this area of research are presented.
Collapse
Affiliation(s)
- Klodian Xhanari
- University of Maribor, Faculty of Chemistry and Chemical Engineering, Smetanova ulica 17, 2000 Maribor, Slovenia.
- University of Tirana, Faculty of Natural Sciences, Boulevard "Zogu I", 1001 Tirana, Albania
| | - Matjaž Finšgar
- University of Maribor, Faculty of Chemistry and Chemical Engineering, Smetanova ulica 17, 2000 Maribor, Slovenia.
| |
Collapse
|
5
|
Pourmadadi M, Rajabzadeh-Khosroshahi M, Saeidi Tabar F, Ajalli N, Samadi A, Yazdani M, Yazdian F, Rahdar A, Díez-Pascual AM. Two-Dimensional Graphitic Carbon Nitride (g-C 3N 4) Nanosheets and Their Derivatives for Diagnosis and Detection Applications. J Funct Biomater 2022; 13:204. [PMID: 36412845 PMCID: PMC9680252 DOI: 10.3390/jfb13040204] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Revised: 10/21/2022] [Accepted: 10/23/2022] [Indexed: 12/14/2022] Open
Abstract
The early diagnosis of certain fatal diseases is vital for preventing severe consequences and contributes to a more effective treatment. Despite numerous conventional methods to realize this goal, employing nanobiosensors is a novel approach that provides a fast and precise detection. Recently, nanomaterials have been widely applied as biosensors with distinctive features. Graphite phase carbon nitride (g-C3N4) is a two-dimensional (2D) carbon-based nanostructure that has received attention in biosensing. Biocompatibility, biodegradability, semiconductivity, high photoluminescence yield, low-cost synthesis, easy production process, antimicrobial activity, and high stability are prominent properties that have rendered g-C3N4 a promising candidate to be used in electrochemical, optical, and other kinds of biosensors. This review presents the g-C3N4 unique features, synthesis methods, and g-C3N4-based nanomaterials. In addition, recent relevant studies on using g-C3N4 in biosensors in regard to improving treatment pathways are reviewed.
Collapse
Affiliation(s)
- Mehrab Pourmadadi
- School of Chemical Engineering, College of Engineering, University of Tehran, Tehran 14179-35840, Iran
| | | | - Fatemeh Saeidi Tabar
- School of Chemical Engineering, College of Engineering, University of Tehran, Tehran 14179-35840, Iran
| | - Narges Ajalli
- School of Chemical Engineering, College of Engineering, University of Tehran, Tehran 14179-35840, Iran
| | - Amirmasoud Samadi
- School of Chemical Engineering, College of Engineering, University of Tehran, Tehran 14179-35840, Iran
- Department of Chemical and Biomolecular Engineering, 6000 Interdisciplinary Science & Engineering Building (ISEB), Irvine, CA 92617, USA
| | - Mahsa Yazdani
- School of Chemical Engineering, College of Engineering, University of Tehran, Tehran 14179-35840, Iran
- Department of Biomedical Engineering, State University of New York at Buffalo, Buffalo, NY 14260, USA
| | - Fatemeh Yazdian
- Department of Life Science Engineering, Faculty of New Science and Technologies, University of Tehran, Tehran 14179-35840, Iran
| | - Abbas Rahdar
- Department of Physics, Faculty of science, University of Zabol, Zabol 538-98615, Iran
| | - Ana M. Díez-Pascual
- Universidad de Alcalá, Facultad de Ciencias, Departamento de Química Analítica, Química Física e Ingeniería Química, Ctra. Madrid-Barcelona, Km. 33.6, 28805 Alcalá de Henares, Madrid, Spain
| |
Collapse
|
6
|
Malik R, Joshi N, Tomer VK. Functional graphitic carbon (IV) nitride: A versatile sensing material. Coord Chem Rev 2022. [DOI: 10.1016/j.ccr.2022.214611] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
7
|
Electrochemical Devices to Monitor Ionic Analytes for Healthcare and Industrial Applications. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10010022] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Recent advances in electrochemical devices have sparked exciting opportunities in the healthcare, environment, and food industries. These devices can be fabricated at low costs and are capable of multiplex monitoring. This overcomes challenges presnted in traditional sensors for biomolecules and provides us a unique gateway toward comprehensive analyses. The advantages of electrochemical sensors are derived from their direct integration with electronics and their high selectivity along with sensitivity to sense a wide range of ionic analytes at an economical cost. This review paper aims to summarize recent innovations of a wide variety of electrochemical sensors for ionic analytes for health care and industrial applications. Many of these ionic analytes are important biomarkers to target for new diagnostic tools for medicine, food quality monitoring, and pollution detection. In this paper, we will examine various fabrication techniques, sensing mechanisms, and will also discuss various future opportunities in this research direction.
Collapse
|
8
|
Chen S, Yu J, Chen Z, Huang Z, Song Y. Simultaneous electrochemical sensing of heavy metal ions based on a g-C 3N 4/CNT/NH 2-MIL-88(Fe) nanocomposite. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:5830-5837. [PMID: 34842866 DOI: 10.1039/d1ay01682b] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
The presence of Cd2+, Pb2+, Cu2+ and Hg2+ in drinking-water can be harmful to human health, even if their concentration is fairly low. Hence, it is significant to detect these heavy metal ions in sewage to evaluate the quality of water. Herein, amino-functionalized metal-organic frameworks (NH2-MIL-88(Fe)) embedded with graphitic carbon nitride (g-C3N4) nanosheets and acid-functionalized carbon nanotubes were prepared via a one-pot synthesis. The composite can be directly modified on the surface of glass carbon electrodes without the assistance of Nafion or other binders. The modified glass carbon electrodes can be used to simultaneously detect Cd2+, Pb2+, Cu2+ and Hg2+ in water via square wave stripping voltammetry. The doping of g-C3N4 in the composite, rich in N-containing functional groups, participates in the adsorption of metal ions on the surface of the electrodes. The porous composite provides accommodation room for metals generated by electro-reduction. The detection limit for Cd2+, Pb2+, Cu2+ and Hg2+ is 39.6 nM, 7.6 nM, 11.9 nM, and 9.6 nM, respectively. And the sensitivity for Cd2+, Pb2+, Cu2+ and Hg2+ is 0.0789 mA μM-1 cm-2, 0.4122 mA μM-1 cm-2, 0.2616 mA μM-1 cm-2, and 0.3251 mA μM-1 cm-2, respectively. This work not only enriches the functional design of Fe-MOF materials, but also develops a method for the determination of metal ions using the adsorption sites in g-C3N4.
Collapse
Affiliation(s)
- Shouhui Chen
- College of Chemistry and Chemical Engineering, Jiangxi Normal University, 99 Ziyang Road, Nanchang 330022, China.
| | - Jingguo Yu
- College of Chemistry and Chemical Engineering, Jiangxi Normal University, 99 Ziyang Road, Nanchang 330022, China.
| | - Zhen Chen
- College of Chemistry and Chemical Engineering, Jiangxi Normal University, 99 Ziyang Road, Nanchang 330022, China.
| | - Zhenzhong Huang
- College of Chemistry and Chemical Engineering, Jiangxi Normal University, 99 Ziyang Road, Nanchang 330022, China.
| | - Yonghai Song
- College of Chemistry and Chemical Engineering, Jiangxi Normal University, 99 Ziyang Road, Nanchang 330022, China.
| |
Collapse
|
9
|
Yu H, Guo W, Lu X, Xu H, Yang Q, Tan J, Zhang W. Reduced graphene oxide nanocomposite based electrochemical biosensors for monitoring foodborne pathogenic bacteria: A review. Food Control 2021. [DOI: 10.1016/j.foodcont.2021.108117] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|
10
|
Martinez Jimenez M, Avila A, de Barros A, Lopez EO, Alvarez F, Riul A, Perez-Taborda JA. Polyethyleneimine-Functionalized Carbon Nanotube/Graphene Oxide Composite: A Novel Sensing Platform for Pb(II) Acetate in Aqueous Solution. ACS OMEGA 2021; 6:18190-18199. [PMID: 34308050 PMCID: PMC8296609 DOI: 10.1021/acsomega.1c02085] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Accepted: 06/03/2021] [Indexed: 05/03/2023]
Abstract
Heavy metal pollution is posing a severe health risk on living organisms. Therefore, significant research efforts are focused on their detection. Here, we developed a sensing platform sensor for the selective detection of lead(II) acetate. The sensor is based on self-assembled polyethyleneimine-functionalized carbon nanotubes (PEI-CNTs) and graphene oxide films deposited onto gold interdigitated electrodes. The graphene-based nanostructure showed a resistive behavior, and the fabricated layer-by-layer film was used to detect Pb(II) acetate in an aqueous solution by comparison of three electrochemical methods: impedance spectroscopy, amperometry, and potentiometry stripping analysis. The results obtained from different methods show that the detection limit was down to 36 pmol/L and the sensitivity up to 4.3 μAL/μmol, with excellent repeatability. The detection mechanism was associated with the high affinity of heavy metal ions with the functional groups present in the PEI-CNTs and GO, allowing high performance and sensitivity. The achieved results are important for the research toward integrated monitoring and sensing platforms for Pb(II) contamination in drinking water.
Collapse
Affiliation(s)
- Mawin
J. Martinez Jimenez
- Colombian
Society of Engineering Physics (SCIF), Pereira 660003, Colombia
- Department
of Applied Physics, “Gleb Wataghin” Institute of Physics, University of Campinas—UNICAMP, Campinas 13083-970, São Paulo, Brazil
| | - Alba Avila
- Centro
de Microelectrónica (CMUA), Departamento de Ingeniería
Eléctrica y Electrónica, Universidad
de los Andes, Bogotá 111711, Colombia
| | - Anerise de Barros
- Laboratory
of Functional Materials, Institute of Chemistry, University of Campinas—UNICAMP, P.O. Box 6154, Campinas 13083-970, São Paulo, Brazil
| | - Elvis Oswaldo Lopez
- Department
of Experimental Low Energy Physics, Brazilian
Center for Research in Physics (CBPF), Rua Dr. Xavier Sigaud 150, Rio de Janeiro 22290-180, Brazil
| | - Fernando Alvarez
- Department
of Applied Physics, “Gleb Wataghin” Institute of Physics, University of Campinas—UNICAMP, Campinas 13083-970, São Paulo, Brazil
| | - Antonio Riul
- Department
of Applied Physics, “Gleb Wataghin” Institute of Physics, University of Campinas—UNICAMP, Campinas 13083-970, São Paulo, Brazil
| | - Jaime Andres Perez-Taborda
- Colombian
Society of Engineering Physics (SCIF), Pereira 660003, Colombia
- Centro
de Microelectrónica (CMUA), Departamento de Ingeniería
Eléctrica y Electrónica, Universidad
de los Andes, Bogotá 111711, Colombia
| |
Collapse
|