1
|
Tan AYS, Cheng F, Zhang M, Tan MTT, Manickam S, Muthoosamy K. Graphitic carbon nitride/1-pyrenebutyric acid N-hydroxysuccinimide/polythiophene nanocomposite photoelectrochemical biosensor for CA 19-9 detection. Talanta 2025; 293:128065. [PMID: 40253965 DOI: 10.1016/j.talanta.2025.128065] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2024] [Revised: 03/23/2025] [Accepted: 04/01/2025] [Indexed: 04/22/2025]
Abstract
A photoelectrochemical (PEC) biosensor composed entirely of carbon nanomaterials was synthesized to detect carbohydrate antigen 19-9 (CA 19-9). The biosensor platform integrated graphitic carbon nitride (GCN), known for its light sensitivity, polythiophene (PTh), an organic conductive and optically active material, and 1-pyrenebutyric acid N-hydroxysuccinimide (PBASE), which functions both as a biolinker to conjugate CA 19-9 antibody and antigen and as an electron mediator to facilitate electron transfer from GCN to PTh. The formation of a Schottky heterojunction between PTh and GCN reduced the bandgap of GCN from 2.66 to 1.96 eV, which enhanced transfer of photogenerated electrons for cathodic photocurrent generation. The improvement of charge transfer due to heterojunction formation and π-π stacking between GCN and the pyrene group of PBASE is confirmed by cyclic voltammetry (CV), electron impedance spectroscopy (EIS), and chronoamperometry (CA) findings. The highest current of 1.31 μA is observed for combination of 5 wt% PTh with a GCN/PBASE ratio of 1:0.5. Besides evaluating the electron mobility of GCN/PBASE/PTh, CV, EIS, and CA were also used to evaluate the sensor performance. Optimization studies revealed that 0.6 μg of CA 19-9 antibody and 1 h of antigen-antibody immobilization time significantly improved the biosensor response. The GCN/PBASE/PTh biosensor demonstrated high sensitivity to CA 19-9 antigen across a concentration of 50-1000 U/ml and a detection limit as low as 0.052 U/ml. The reported working range is within the limits required for diagnostic testing of patients with hepatic and heart problems as well as for post-treatment monitoring of colorectal and pancreatic cancer patients.
Collapse
Affiliation(s)
- Adriel Yan Sheng Tan
- Guangdong Engineering and Technology Research Centre for Advanced Nanomaterials, School of Environment and Civil Engineering, Dongguan University of Technology, Dongguan, 523808, China; Nanotechnology Research Group, Faculty of Science and Engineering, University of Nottingham Malaysia, Jalan Broga, 43500 Semenyih, Selangor, Malaysia
| | - Faliang Cheng
- Guangdong Engineering and Technology Research Centre for Advanced Nanomaterials, School of Environment and Civil Engineering, Dongguan University of Technology, Dongguan, 523808, China.
| | - Min Zhang
- Guangdong Engineering and Technology Research Centre for Advanced Nanomaterials, School of Environment and Civil Engineering, Dongguan University of Technology, Dongguan, 523808, China
| | - Michelle T T Tan
- Department of Electrical and Electronic Engineering, Faculty of Science and Engineering, University of Nottingham Malaysia, Jalan Broga, 43500 Semenyih, Selangor, Malaysia
| | - Sivakumar Manickam
- Petroleum and Chemical Engineering, Faculty of Engineering, Universiti Teknologi Brunei, Bandar Seri Begawan, BE1410, Brunei Darussalam
| | - Kasturi Muthoosamy
- Nanotechnology Research Group, Faculty of Science and Engineering, University of Nottingham Malaysia, Jalan Broga, 43500 Semenyih, Selangor, Malaysia.
| |
Collapse
|
2
|
Jin W, Chen R, Wu L, Peng C, Song Y, Miao L, Wang L. An "on-off" electrochemical immunosensor for the detection of the glycan antigen CA125 by amplification signals using electropositive COFs. Talanta 2025; 286:127593. [PMID: 39813914 DOI: 10.1016/j.talanta.2025.127593] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2024] [Revised: 01/02/2025] [Accepted: 01/11/2025] [Indexed: 01/18/2025]
Abstract
Cancer Antigen 125 (CA125), is a high molecular weight mucinous glycoprotein found on the surface of ovarian cancer cells. Generally, 90 % of women may appear a high concentration of CA125 when they got the cancer; thus, CA125 can act as a marker for ovarian cancer diagnosis and therapeutic evaluation. COFs have been widely used for disease detection due to their structural stability, high loading capacity and biocompatibility. However, the limited variety of electroactive COFs used as signal probes, fewer enriched signaling molecules, weaker electrical signals generated, and higher oxidation or reduction potentials of electroactive substances, a series of side reactions are easily triggered causing serious interference. To solve the above problems, [Fe(CN)6]3/4- as a signal probe and COFs for signal amplification were selected to creating a highly sensitive electrochemical immunosensor for glycan antigen CA125. Firstly, two-dimensional (2D) EP-TD-COF with ultra-high specific surface area was modified on bare GCE, which could covalently bound numerous Ab1 molecules due to the epoxy-rich functional groups. Then, the electropositive AuNPs@2DCOFBTT-DGMH was prepared by the in situ growth of AuNPs, proved an effective platform for loading Ab2 molecules via Au-S bonds. Based on the positively charged AuNPs@COFBTT-DGMH/Ab2 and negatively charged [Fe(CN)6]3/4- of electrostatic interactions, which could significantly enchaned signal for quantitative and sensitive detection of CA125. The constructed immunosensor exhibits excellent stability performance and high sensitivity, enabling ultrasensitive detection of trace glycan antigens. This study provided a new idea for the use of non-electroactive substances for the construction of electrochemical immunosensors and provided an effective signal amplification strategy.
Collapse
Affiliation(s)
- Wenxiao Jin
- College of Chemistry and Materials, Jiangxi Normal University, 99 Ziyang Avenue, Nanchang, 330022, China
| | - Rongfang Chen
- College of Chemistry and Materials, Jiangxi Normal University, 99 Ziyang Avenue, Nanchang, 330022, China
| | - Likang Wu
- College of Chemistry and Materials, Jiangxi Normal University, 99 Ziyang Avenue, Nanchang, 330022, China
| | - Canwei Peng
- College of Chemistry and Materials, Jiangxi Normal University, 99 Ziyang Avenue, Nanchang, 330022, China
| | - Yonghai Song
- College of Chemistry and Materials, Jiangxi Normal University, 99 Ziyang Avenue, Nanchang, 330022, China.
| | - Longfei Miao
- College of Chemistry and Materials, Jiangxi Normal University, 99 Ziyang Avenue, Nanchang, 330022, China.
| | - Li Wang
- College of Chemistry and Materials, Jiangxi Normal University, 99 Ziyang Avenue, Nanchang, 330022, China
| |
Collapse
|
3
|
Xie H, Zhu S, Wen P, Zhou D, Yin Y, Lan Y, Lee TC, Zhang Y, Pu Q. Raspberry-Like Plasmonic Nanoaggregates with Programmable Hierarchical Structures for Reproducible SERS Detection of Wastewater Pollutants and Biomarkers. Anal Chem 2024; 96:17620-17630. [PMID: 39445382 PMCID: PMC11541892 DOI: 10.1021/acs.analchem.4c03533] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2024] [Revised: 09/30/2024] [Accepted: 10/15/2024] [Indexed: 10/25/2024]
Abstract
Conventional solid-based SERS substrates often face challenges with inconsistent sample distribution, while liquid-based SERS substrates are prone to aggregation and precipitation, resulting in irreproducible signals in both cases. In this study, we tackled this dilemma by designing and synthesizing raspberry-like plasmonic nanoaggregates that exhibit a high density of hotspots and are colloidally stable at the same time. In particular, the nanoaggregates consist of a core made of functionalized polystyrene (PS) microspheres, which act as a template for rapid self-assembly of Au@Ag core-shell nanoparticles to form raspberry-like hierarchical nanoaggregates within 5 min of mixing. The optimized nanoaggregates can be used as reproducible and stable SERS substrates for a range of wastewater pollutants (e.g., rhodamine 6G (R6G) and malachite green (MG)) and nucleobases (e.g., adenine and uracil), with the detection limits as low as 1 × 10-10, 1 × 10-16, 3 × 10-8, and 3 × 10-7 M, respectively. Additionally, the trace detection of adenine in clinical urine samples has been successfully demonstrated. Our modular assembly approach opens up new possibilities in SERS substrate design and advanced trace-chemical detection technologies.
Collapse
Affiliation(s)
- Huimin Xie
- College
of Chemistry and Chemical Engineering, Lanzhou
University, Lanzhou 730000, China
| | - Shuyu Zhu
- College
of Chemistry and Chemical Engineering, Lanzhou
University, Lanzhou 730000, China
| | - Ping Wen
- College
of Chemistry and Chemical Engineering, Lanzhou
University, Lanzhou 730000, China
| | - Deyue Zhou
- Institute
for Materials Discovery, University College
London, London WC1H 0AJ, U.K.
| | - Yidan Yin
- Institute
for Materials Discovery, University College
London, London WC1H 0AJ, U.K.
| | - Yang Lan
- Department
of Chemical Engineering, University College
London, London WC1E 7JE, U.K.
| | - Tung-Chun Lee
- Institute
for Materials Discovery, University College
London, London WC1H 0AJ, U.K.
| | - Yuewen Zhang
- College
of Chemistry and Chemical Engineering, Lanzhou
University, Lanzhou 730000, China
| | - Qiaosheng Pu
- College
of Chemistry and Chemical Engineering, Lanzhou
University, Lanzhou 730000, China
| |
Collapse
|
4
|
Zhao T, Jin B. A label-free electrochemical biosensor based on a bimetallic organic framework for the detection of carbohydrate antigen 19-9. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:6173-6182. [PMID: 39189647 DOI: 10.1039/d4ay01432d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/28/2024]
Abstract
Carbohydrate antigen 19-9 (CA19-9) is an important marker for pancreatic cancer, ovarian cancer and other tumors, and its rapid and stable detection is the basis for early diagnosis and treatment. In this paper, a label-free electrochemical immunosensor for the sensitive detection of CA19-9 has been developed. First, the synthesis of two novel core-shell bimetallic nanomaterials, namely Ce-MOF-on-Fe-MOF and Fe-MOF-on-Ce-MOF, was accomplished using the MOF-on-MOF approach. The poor electrical conductivity of MOF materials was addressed by incorporating polyethylenimide (PEI) functionalized rGO with Ce-MOF-on-Fe-MOF and Fe-MOF-on-Ce-MOF nanomaterials. Simultaneously, toluidine blue (Tb) was employed as a redox probe and physically adsorbed onto the synthesized materials, resulting in the formation of two nanomaterials: rGO@Ce-MOF-on-Fe-MOF@Tb and rGO@Fe-MOF-on-Ce-MOF@Tb. The fundamental characterization reveals that the sensing performance of the rGO@Ce-MOF-on-Fe-MOF@TB-based immune sensor surpasses that of the rGO@Fe-MOF-on-Ce-MOF@TB-based immune sensor, which is attributed to the fact that, unlike the interlayer-constrained structure of Fe-MOF-on-Ce-MOF, in Ce-MOF-on-Fe-MOF, Ce-MOF penetrates into Fe-MOF to form a heterogeneous structure due to the relatively large pore size of Fe-MOF, which better combines the excellent biocompatibility and strong anchoring effect of Fe MOFs on antibodies, as well as the high electrochemical activity and conductivity of Ce-MOF, to enhance sensing performance. The proposed label-free immunosensor based on rGO@Ce-MOF-on-Fe-MOF@Tb has a wide linear range (1-100 000 mU mL-1), a low detection limit (0.34 mU mL-1), good stability, reproducibility, and repeatability, and satisfactory applicability, which provides a potential platform for clinical applications.
Collapse
Affiliation(s)
- Tongxiao Zhao
- Department of Chemistry, Anhui University, Hefei 230601, China.
| | - Baokang Jin
- Department of Chemistry, Anhui University, Hefei 230601, China.
| |
Collapse
|
5
|
Lu C, Tang Z, Wang D, Chen L, Zhao J. Advances in polyoxometalate-based electrochemical sensors in the last three years. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:5133-5145. [PMID: 39007918 DOI: 10.1039/d4ay01090f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/16/2024]
Abstract
As a famous subclass of metal-oxide cluster materials, polyoxometalates (POMs) feature variable architectures, reversible multi-electron transport capability, catalytic activity, and redox capacity. These attributes endow POMs with great potential as promising electrode materials in electrochemical sensors (ECSs). Up to now, POM-based ECSs have been passionately studied, and diverse POM-based redox ECSs, aptasensors and immunosensors have emerged. And these POM-based ECSs generally demonstrate fast response, low detection limit, strong selectivity and high antijamming capability. This review mainly focuses on the remarkable advancement of POM-based ECSs in environmental monitoring, food safety and biomedicine from 2021, aiming to furnish theoretical insights that inform the design and development of innovative sensors.
Collapse
Affiliation(s)
- Changyuan Lu
- School of Environmental Engineering, Yellow River Conservancy Technical Institute, Kaifeng 475004, China
- Henan Key Laboratory of Polyoxometalate Chemistry, College of Chemistry and Chemical Engineering, Henan University, Kaifeng 475004, China.
| | - Zhigang Tang
- Henan Key Laboratory of Polyoxometalate Chemistry, College of Chemistry and Chemical Engineering, Henan University, Kaifeng 475004, China.
| | - Dan Wang
- Henan Key Laboratory of Polyoxometalate Chemistry, College of Chemistry and Chemical Engineering, Henan University, Kaifeng 475004, China.
| | - Lijuan Chen
- Henan Key Laboratory of Polyoxometalate Chemistry, College of Chemistry and Chemical Engineering, Henan University, Kaifeng 475004, China.
| | - Junwei Zhao
- Henan Key Laboratory of Polyoxometalate Chemistry, College of Chemistry and Chemical Engineering, Henan University, Kaifeng 475004, China.
| |
Collapse
|
6
|
Cotchim S, Kongkaew S, Thavarungkul P, Kanatharana P, Limbut W. A dual-electrode label-free immunosensor based on in situ prepared Au-MoO 3-Chi/porous graphene nanoparticles for point-of-care detection of cholangiocarcinoma. Talanta 2024; 272:125755. [PMID: 38364561 DOI: 10.1016/j.talanta.2024.125755] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2023] [Revised: 02/01/2024] [Accepted: 02/05/2024] [Indexed: 02/18/2024]
Abstract
A novel label-free electrochemical immunosensor was prepared for the detection of carbohydrate antigen 19-9 (CA19-9) and carcinoembryonic antigen (CEA) as biomarkers of cholangiocarcinoma (CCA). A nanocomposite of gold nanoparticles, molybdenum trioxide, and chitosan (Au-MoO3-Chi) was layer-by-layer assembled on the porous graphene (PG) modified a dual screen-printed electrode using a self-assembling technique, which increased surface area and conductivity and enhanced the adsorption of immobilized antibodies. The stepwise self-assembling procedure of the modified electrode was further characterized morphologically and functionally. The electroanalytical detection of biomarkers was based on the interaction between the antibody and antigen of each marker via linear sweep voltammetry using ferrocyanide/ferricyanide as an electrochemical redox indicator. Under optimized conditions, the fabricated immunosensor showed linear relationships between current change (ΔI) and antigen concentrations in two ranges: 0.0025-0.1 U mL-1 and 0.1-1.0 U mL-1 for CA19-9, and 0.001-0.01 ng mL-1 and 0.01-1.0 ng mL-1 for CEA. The limits of detection (LOD) were 1.0 mU mL-1 for CA19-9 and 0.5 pg mL-1 for CEA. Limits of quantitation (LOQ) were 3.3 mU mL-1 for CA19-9 and 1.6 pg mL-1 for CEA. The selectivity of the developed immunosensor was tested on mixtures of antigens and was then successfully applied to determine CA19-9 and CEA in human serum samples, producing satisfactory results consistent with the clinical method.
Collapse
Affiliation(s)
- Suparat Cotchim
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Supatinee Kongkaew
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Panote Thavarungkul
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Proespichaya Kanatharana
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Warakorn Limbut
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Forensic Science Innovation and Service Center, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand.
| |
Collapse
|
7
|
Ahmadipour M, Bhattacharya A, Sarafbidabad M, Syuhada Sazali E, Krishna Ghoshal S, Satgunam M, Singh R, Rezaei Ardani M, Missaoui N, Kahri H, Pal U, Ling Pang A. CA19-9 and CEA biosensors in pancreatic cancer. Clin Chim Acta 2024; 554:117788. [PMID: 38246211 DOI: 10.1016/j.cca.2024.117788] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2023] [Revised: 01/15/2024] [Accepted: 01/15/2024] [Indexed: 01/23/2024]
Abstract
Cancer is a complex pathophysiological condition causing millions of deaths each year. Early diagnosis is essential especially for pancreatic cancer. Existing diagnostic tools rely on circulating biomarkers such as Carbohydrate Antigen 19-9 (CA19-9) and Carcinoembryonic Antigen (CEA). Unfortunately, these markers are nonspecific and may be increased in a variety of disorders. Accordingly, diagnosis of pancreatic cancer generally involves more invasive approaches such as biopsy as well as imaging studies. Recent advances in biosensor technology have allowed the development of precise diagnostic tools having enhanced analytical sensitivity and specificity. Herein we examine these advances in the detection of cancer in general and in pancreatic cancer specifically. Furthermore, we highlight novel technologies in the measurement of CA19-9 and CEA and explore their future application in the early detection of pancreatic cancer.
Collapse
Affiliation(s)
- Mohsen Ahmadipour
- Institute of Power Engineering, Universiti Tenaga Nasional, 43650 Serdang, Selangor, Malaysia.
| | - Anish Bhattacharya
- Advanced Optical Materials Research Group, Department of Physics, Faculty of Science, Universiti Teknologi Malaysia, 81310 Skudai, Johor, Malaysia; Ibnu Sina Institute of Laser Centre, Universiti Teknologi Malaysia, 81310 Skudai, Johor, Malaysia
| | - Mohsen Sarafbidabad
- Biomedical Engineering Department, Faculty of Engineering, University of Isfahan, Isfahan, Iran
| | - Ezza Syuhada Sazali
- Advanced Optical Materials Research Group, Department of Physics, Faculty of Science, Universiti Teknologi Malaysia, 81310 Skudai, Johor, Malaysia; Ibnu Sina Institute of Laser Centre, Universiti Teknologi Malaysia, 81310 Skudai, Johor, Malaysia
| | - Sib Krishna Ghoshal
- Advanced Optical Materials Research Group, Department of Physics, Faculty of Science, Universiti Teknologi Malaysia, 81310 Skudai, Johor, Malaysia; Ibnu Sina Institute of Laser Centre, Universiti Teknologi Malaysia, 81310 Skudai, Johor, Malaysia
| | - Meenaloshini Satgunam
- Institute of Power Engineering, Universiti Tenaga Nasional, 43650 Serdang, Selangor, Malaysia; Department of Mechanical Engineering, Universiti Tenaga Nasional, 43650 Serdang, Selangor, Malaysia
| | - Ramesh Singh
- Institute of Power Engineering, Universiti Tenaga Nasional, 43650 Serdang, Selangor, Malaysia; Center of Advanced Manufacturing and Materials Processing (AMMP), Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur, Malaysia
| | - Mohammad Rezaei Ardani
- School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, Engineering Campus, 14300 Nibong Tebal, Pulau Pinang, Malaysia
| | - Nadhem Missaoui
- Laboratory of Interfaces and Advanced Materials, Faculty of Sciences, University of Monastir, Monastir, Tunisia
| | - Hamza Kahri
- Laboratory of Interfaces and Advanced Materials, Faculty of Sciences, University of Monastir, Monastir, Tunisia
| | - Ujjwal Pal
- Department of Analytical and Structural Chemistry, CSIR-Indian Institute of Chemical Technology, Hyderabad, India
| | - Ai Ling Pang
- Department of Chemical Science, Faculty of Science, Universiti Tunku Abdul Rahman, 31900 Kampar, Perak, Malaysia
| |
Collapse
|
8
|
Haarindraprasad RP, Thurga Devi N, Thevendran R, Maheswaran S. Spiked nanorosette: A novel zinc oxide-gold textured nanostructure for impedance biosensing of target DNA signatures. Biotechnol J 2023; 18:e2300092. [PMID: 37139895 DOI: 10.1002/biot.202300092] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Revised: 04/23/2023] [Accepted: 04/26/2023] [Indexed: 05/05/2023]
Abstract
The creation of nanostructure is profound for the generation of nanobiosensors in several medical diagnosis. Here, we employed an aqueous hydrothermal route using Zinc-oxide (ZnO) and Gold (Au), which under optimal conditions formed an ultra-crystalline rose-like nanostructure textured with nanowires on the surface, coined as "spiked nanorosette." The spiked nanorosette structures was further characterized to possess crystallites of ZnO and Au grains with average sizes of 27.60 and 32.33 nm, respectively. The intensity for both ZnO (002) and Au (111) planes of the nanocomposite was inferred to be controlled by fine-tuning the percentage of Au nanoparticles doped in the ZnO/Au matrix, as referred by X-ray diffraction analysis. The formation of ZnO/Au-hybrid nanorosettes were additionally verified by the distinct corresponding peaks from photoluminescence and X-ray photoelectron spectroscopy, supported by electrical validations. The biorecognition properties of the spiked nanorosettes were also examined using custom targeted and non-target DNA sequences. The DNA targeting capabilities of the nanostructures were analyzed by Fourier Transform Infrared and electrochemical impedance spectroscopy. The fabricated nanowire-embedded nanorosette exhibited a detection limit at the lower picomolar range of 1 × 10-12 M, with high selectivity, stability and reproducibility and good linearity, under optimal conditions. Impedance-based techniques are more sensitive to the detection of nucleic acid molecule whereas this novel spiked nanorosette demonstrate promising attributes as excellent nanostructures for nanobiosensor developments and their potential future application for nucleic-acids or disease diagnostics.
Collapse
Affiliation(s)
- Rajintra Prasad Haarindraprasad
- Faculty of Engineering and Computer Technology (FECT), AIMST University, Bedong-Semeling, Kedah, Malaysia
- Centre for Excellence in Biomaterials Engineering (CoEBE), AIMST University, Bedong-Semeling, Kedah, Malaysia
| | - Nathan Thurga Devi
- Clinical Research Centre, Hospital Sultan Abdul Halim, Sungai Petani, Kedah, Malaysia
| | - Ramesh Thevendran
- Department of Biotechnology, Faculty of Applied Sciences, AIMST University, Bedong, Kedah, Malaysia
| | - Solayappan Maheswaran
- Department of Biotechnology, Faculty of Applied Sciences, AIMST University, Bedong, Kedah, Malaysia
- Centre of Excellence for Nanobiotechnology & Nanomedicine (CoExNano), Faculty of Applied Sciences, AIMST University, Bedong, Kedah, Malaysia
| |
Collapse
|
9
|
Rahmani H, Mansouri Majd S, Salimi A, Ghasemi F. Ultrasensitive immunosensor for monitoring of CA 19-9 pancreatic cancer marker using electrolyte-gated TiS 3 nanoribbons field-effect transistor. Talanta 2023; 257:124336. [PMID: 36863296 DOI: 10.1016/j.talanta.2023.124336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2022] [Revised: 02/04/2023] [Accepted: 02/07/2023] [Indexed: 02/12/2023]
Abstract
Measuring CA 19-9 antigen level is critical for early diagnosis of pancreatic cancer, monitoring the treatment process, and predicting disease recurrence. The purpose of this research is to assess the application of novel few-layered TiS3 nanoribbons material as a channel material in electrolyte-gated field-effect transistor immunosensor for rapid detection of CA 19-9 antigen as a cancer marker. Accordingly, TiS3 nanoribbons were produced through liquid-phase exfoliation of as-synthesized TiS3 whiskers in N, N-dimethylformamide. Then, dispersed TiS3 nanoribbons were drop cast onto the FET surface to form an active channel material between source and drain electrodes. Subsequently, the channel surface was modified by utilizing 1-naphthylamine (NA) and glutaraldehyde (GA) to strengthen the binding of monoclonal antibody 19-9 to TiS3 nanoribbons. Spectroscopic and microscopic methods were utilized for comprehensive characterizations. Electrical characterization of electrolyte-gated TiS3 nanoribbons field-effect transistor represented a depletion-mode n-type behavior with field-effect mobility of 0.059 cm2/Vs, current on/off ratio of 10.88 and subthreshold swing (SS) of 450.9 mV/decade. With increasing in CA 19-9 antigen concentration from 1.0 × 10-12 U/mL to 1.0 × 10-5 U/mL, a decrease in the drain current occurred with high sensitivity of 0.04 μA/decade and a detection limit of 1.3 × 10-13 U/mL. Additionally, the proposed TiS3 nanoribbons FET immunosensor exhibited outstanding selectivity, and its good performance was compared with an enzyme-linked immunosorbent assay (ELISA) for spiked real human serum samples. The good and satisfactory obtained results of the proposed immunosensor suggest that the developed platform can be a superb candidate for cancer diagnosis and therapeutic monitoring.
Collapse
Affiliation(s)
- Hedyeh Rahmani
- Department of Chemistry, University of Kurdistan, 66177-15175, Sanandaj, Iran
| | | | - Abdollah Salimi
- Department of Chemistry, University of Kurdistan, 66177-15175, Sanandaj, Iran; Research Center for Nanotechnology, University of Kurdistan, 66177-15175, Sanandaj, Iran.
| | - Foad Ghasemi
- Nanoscale Physics Device Lab (NPDL), Department of Physics, University of Kurdistan, 66177-15175, Sanandaj, Iran
| |
Collapse
|
10
|
Ekwujuru EU, Olatunde AM, Klink MJ, Ssemakalu CC, Chili MM, Peleyeju MG. Electrochemical and Photoelectrochemical Immunosensors for the Detection of Ovarian Cancer Biomarkers. SENSORS (BASEL, SWITZERLAND) 2023; 23:4106. [PMID: 37112447 PMCID: PMC10142013 DOI: 10.3390/s23084106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Revised: 03/20/2023] [Accepted: 03/28/2023] [Indexed: 06/19/2023]
Abstract
Photoelectrochemical (PEC) sensing is an emerging technological innovation for monitoring small substances/molecules in biological or non-biological systems. In particular, there has been a surge of interest in developing PEC devices for determining molecules of clinical significance. This is especially the case for molecules that are markers for serious and deadly medical conditions. The increased interest in PEC sensors to monitor such biomarkers can be attributed to the many apparent advantages of the PEC system, including an enhanced measurable signal, high potential for miniaturization, rapid testing, and low cost, amongst others. The growing number of published research reports on the subject calls for a comprehensive review of the various findings. This article is a review of studies on electrochemical (EC) and PEC sensors for ovarian cancer biomarkers in the last seven years (2016-2022). EC sensors were included because PEC is an improved EC; and a comparison of both systems has, expectedly, been carried out in many studies. Specific attention was given to the different markers of ovarian cancer and the EC/PEC sensing platforms developed for their detection/quantification. Relevant articles were sourced from the following databases: Scopus, PubMed Central, Web of Science, Science Direct, Academic Search Complete, EBSCO, CORE, Directory of open Access Journals (DOAJ), Public Library of Science (PLOS), BioMed Central (BMC), Semantic Scholar, Research Gate, SciELO, Wiley Online Library, Elsevier and SpringerLink.
Collapse
Affiliation(s)
- Ezinne U. Ekwujuru
- Department of Biotechnology and Chemistry, Vaal University of Technology, Vanderbijlpark 1911, South Africa
| | | | - Michael J. Klink
- Department of Biotechnology and Chemistry, Vaal University of Technology, Vanderbijlpark 1911, South Africa
| | - Cornelius C. Ssemakalu
- Department of Biotechnology and Chemistry, Vaal University of Technology, Vanderbijlpark 1911, South Africa
| | - Muntuwenkosi M. Chili
- Department of Biotechnology and Chemistry, Vaal University of Technology, Vanderbijlpark 1911, South Africa
- Centre for Academic Development, Vaal University of Technology, Vanderbijlpark 1911, South Africa
| | - Moses G. Peleyeju
- Department of Biotechnology and Chemistry, Vaal University of Technology, Vanderbijlpark 1911, South Africa
- Centre for Academic Development, Vaal University of Technology, Vanderbijlpark 1911, South Africa
| |
Collapse
|
11
|
Gholamin D, Karami P, Pahlavan Y, Johari-Ahar M. Highly sensitive photoelectrochemical immunosensor for detecting cancer marker CA19-9 based on a new SnSe quantum dot. Mikrochim Acta 2023; 190:154. [PMID: 36961600 DOI: 10.1007/s00604-023-05718-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2022] [Accepted: 02/23/2023] [Indexed: 03/25/2023]
Abstract
A sandwich-type photoelectrochemical (PEC) immunosensor was constructed on a screen-printed electrode (SPE) using gold-coated tin selenide quantum dots (Au-SnSe QDs) to determine the carbohydrate antigen 19 9 (CA19-9). Water-soluble Au-SnSe QDs were prepared by coating low-cost SnSe QDs, prepared by reacting tin(II) 2-ethyl hexanoate with selenium ions (HNaSe) without needing to add an external capping agent (SnSe QDs). SnSe-based QDs were characterized using high-resolution transmission electron microscopy (HR-TEM) and dynamic light scattering (DLS). DSP (dithio-bis (succinimidyl propionate)) as a linker was attached on Au@SnSe QDs and conjugated with CA19-9 monoclonal antibodies (Ab2-DSP-Au@SnSE QD). For capture probe assembling, an Au nano-layer was electrochemically deposited on a SPE by HAuCl4 reduction using 12 cycles of cyclic voltammetry (0 to - 1.4 V) at the scan rate of 50 mV s-1, then covered by self-assembly of DSP and covalent conjugation of CA19-9 Ab1. Our developed PEC immunosensor showed a significant photoelectrochemical response, recorded using chronoamperometry (0.3 V), for the presence of CA19-9 antigen in serum samples under light irradiation, with a detection limit (LOD) of 0.0011 U mL-1 and a dynamic range of 0.005-100 U mL-1. The recovery of CA19-9 determination from serum samples was 101 to 113%.
Collapse
Affiliation(s)
- Danial Gholamin
- Biosensor Sciences and Technologies Research Center, Ardabil University of Medical Sciences, Ardabil, Iran
- Department of Medicinal Chemistry, School of Pharmacy, Ardabil University of Medical Sciences, Ardabil, Iran
| | - Pari Karami
- Biosensor Sciences and Technologies Research Center, Ardabil University of Medical Sciences, Ardabil, Iran
| | - Yasamin Pahlavan
- Biosensor Sciences and Technologies Research Center, Ardabil University of Medical Sciences, Ardabil, Iran
| | - Mohammad Johari-Ahar
- Biosensor Sciences and Technologies Research Center, Ardabil University of Medical Sciences, Ardabil, Iran.
- Department of Medicinal Chemistry, School of Pharmacy, Ardabil University of Medical Sciences, Ardabil, Iran.
| |
Collapse
|
12
|
Rao Bommi J, Kummari S, Lakavath K, Sukumaran RA, Panicker LR, Marty JL, Yugender Goud K. Recent Trends in Biosensing and Diagnostic Methods for Novel Cancer Biomarkers. BIOSENSORS 2023; 13:398. [PMID: 36979610 PMCID: PMC10046866 DOI: 10.3390/bios13030398] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Revised: 03/13/2023] [Accepted: 03/15/2023] [Indexed: 06/18/2023]
Abstract
Cancer is one of the major public health issues in the world. It has become the second leading cause of death, with approximately 75% of cancer deaths transpiring in low- or middle-income countries. It causes a heavy global economic cost estimated at more than a trillion dollars per year. The most common cancers are breast, colon, rectum, prostate, and lung cancers. Many of these cancers can be treated effectively and cured if detected at the primary stage. Nowadays, around 50% of cancers are detected at late stages, leading to serious health complications and death. Early diagnosis of cancer diseases substantially increases the efficient treatment and high chances of survival. Biosensors are one of the potential screening methodologies useful in the early screening of cancer biomarkers. This review summarizes the recent findings about novel cancer biomarkers and their advantages over traditional biomarkers, and novel biosensing and diagnostic methods for them; thus, this review may be helpful in the early recognition and monitoring of treatment response of various human cancers.
Collapse
Affiliation(s)
| | - Shekher Kummari
- Department of Chemistry, Indian Institute of Technology Palakkad, Palakkad 678 557, Kerala, India
| | - Kavitha Lakavath
- Department of Chemistry, Indian Institute of Technology Palakkad, Palakkad 678 557, Kerala, India
| | - Reshmi A. Sukumaran
- Department of Chemistry, Indian Institute of Technology Palakkad, Palakkad 678 557, Kerala, India
| | - Lakshmi R. Panicker
- Department of Chemistry, Indian Institute of Technology Palakkad, Palakkad 678 557, Kerala, India
| | - Jean Louis Marty
- Université de Perpignan Via Domitia, 52 Avenue Paul Alduy, 66860 Perpignan, France
| | - Kotagiri Yugender Goud
- Department of Chemistry, Indian Institute of Technology Palakkad, Palakkad 678 557, Kerala, India
| |
Collapse
|
13
|
Fauzi N, Mohd Asri RI, Mohamed Omar MF, Manaf AA, Kawarada H, Falina S, Syamsul M. Status and Prospects of Heterojunction-Based HEMT for Next-Generation Biosensors. MICROMACHINES 2023; 14:325. [PMID: 36838025 PMCID: PMC9966278 DOI: 10.3390/mi14020325] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/31/2022] [Revised: 01/20/2023] [Accepted: 01/24/2023] [Indexed: 06/18/2023]
Abstract
High electron mobility transistor (HEMT) biosensors hold great potential for realizing label-free, real-time, and direct detection. Owing to their unique properties of two-dimensional electron gas (2DEG), HEMT biosensors have the ability to amplify current changes pertinent to potential changes with the introduction of any biomolecules, making them highly surface charge sensitive. This review discusses the recent advances in the use of AlGaN/GaN and AlGaAs/GaAs HEMT as biosensors in the context of different gate architectures. We describe the fundamental mechanisms underlying their operational functions, giving insight into crucial experiments as well as the necessary analysis and validation of data. Surface functionalization and biorecognition integrated into the HEMT gate structures, including self-assembly strategies, are also presented in this review, with relevant and promising applications discussed for ultra-sensitive biosensors. Obstacles and opportunities for possible optimization are also surveyed. Conclusively, future prospects for further development and applications are discussed. This review is instructive for researchers who are new to this field as well as being informative for those who work in related fields.
Collapse
Affiliation(s)
- Najihah Fauzi
- Institute of Nano Optoelectronics Research and Technology (INOR), Universiti Sains Malaysia, Sains@USM, Bayan Lepas 11900, Pulau Pinang, Malaysia
| | - Rahil Izzati Mohd Asri
- Institute of Nano Optoelectronics Research and Technology (INOR), Universiti Sains Malaysia, Sains@USM, Bayan Lepas 11900, Pulau Pinang, Malaysia
| | - Mohamad Faiz Mohamed Omar
- Collaborative Microelectronic Design Excellence Center (CEDEC), Universiti Sains Malaysia, Sains@USM, Bayan Lepas 11900, Pulau Pinang, Malaysia
| | - Asrulnizam Abd Manaf
- Collaborative Microelectronic Design Excellence Center (CEDEC), Universiti Sains Malaysia, Sains@USM, Bayan Lepas 11900, Pulau Pinang, Malaysia
| | - Hiroshi Kawarada
- Faculty of Science and Engineering, Waseda University, Tokyo 169-8555, Japan
- The Kagami Memorial Laboratory for Materials Science and Technology, Waseda University, Nishiwaseda, Shinjuku, Tokyo 169-0051, Japan
| | - Shaili Falina
- Collaborative Microelectronic Design Excellence Center (CEDEC), Universiti Sains Malaysia, Sains@USM, Bayan Lepas 11900, Pulau Pinang, Malaysia
- Faculty of Science and Engineering, Waseda University, Tokyo 169-8555, Japan
| | - Mohd Syamsul
- Institute of Nano Optoelectronics Research and Technology (INOR), Universiti Sains Malaysia, Sains@USM, Bayan Lepas 11900, Pulau Pinang, Malaysia
- Faculty of Science and Engineering, Waseda University, Tokyo 169-8555, Japan
| |
Collapse
|
14
|
Vaid K, Dhiman J, Kumar S, Kumar V. Citrate and glutathione capped gold nanoparticles for electrochemical immunosensing of atrazine: Effect of conjugation chemistry. ENVIRONMENTAL RESEARCH 2023; 217:114855. [PMID: 36427637 DOI: 10.1016/j.envres.2022.114855] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2022] [Revised: 11/09/2022] [Accepted: 11/17/2022] [Indexed: 06/16/2023]
Abstract
Recently, the exposure of pesticides/herbicides to the living organisms is increased especially due to agricultural malpractices and industrial processes. In particular, the exposure of pesticides/herbicides (e.g., atrazine) can impart several harsh effects on the human health. The development of efficient detection systems can be crucial in monitoring the atrazine in water and food/plant products, which can be decisive in controlling the deadly exposures of atrazine. Herein, we have developed electrochemical immunosensors for atrazine by employing monoclonal anti-atrazine antibody conjugated gold nanoparticles. Two types of gold nanoparticles (i.e., citrate and glutathione (GSH)-capped AuNPs) were used to modify gold working electrode and utilized for the development of atrazine immunosensors. The conjugation of immunoprobe on working electrode was especially designed to obtain stable and efficient sensing signals. The nanosensing immunoprobes fabricated using citrate-AuNPs and GSH-AuNPs exhibited comparable responses for a wide linear working range of 50 ng/L- 30 μg/L with limit of detection (LOD) values of 0.08 and 0.06 ng/L for atrazine, respectively.
Collapse
Affiliation(s)
- Kalyan Vaid
- National Agri-Food Biotechnology Institute (NABI), S.A.S. Nagar, Punjab, 140306, India; Centre for Nanoscience and Nanotechnology, Panjab University, Chandigarh, 160014, India; CSIR-Central Scientific Instruments Organisation, Sector 30-C, Chandigarh, 160030, India
| | - Jasmeen Dhiman
- National Agri-Food Biotechnology Institute (NABI), S.A.S. Nagar, Punjab, 140306, India
| | - Suresh Kumar
- Department of Applied Sciences, UIET, Panjab University, Chandigarh, 160014, India
| | - Vanish Kumar
- National Agri-Food Biotechnology Institute (NABI), S.A.S. Nagar, Punjab, 140306, India; Department of Biotechnology, Thapar Institute of Engineering and Technology, Patiala, 147004, Punjab, India.
| |
Collapse
|
15
|
An impedimetric immunosensor based on PAMAM decorated electrospun polystyrene fibers for detection of interleukin-10 cytokine. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116953] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
16
|
Wang X, Liao X, Zhang B, Chen S, Zhang M, Mei L, Zhang L, Qiao X, Hong C. Fabrication of a novel electrochemical immunosensor for the sensitive detection of carcinoembryonic antigen using a double signal attenuation strategy. Anal Chim Acta 2022; 1232:340455. [DOI: 10.1016/j.aca.2022.340455] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2022] [Revised: 09/24/2022] [Accepted: 09/26/2022] [Indexed: 11/01/2022]
|
17
|
Faradaic electrochemical impedimetric analysis on MoS2/Au-NPs decorated surface for C-reactive protein detection. J Taiwan Inst Chem Eng 2022. [DOI: 10.1016/j.jtice.2022.104450] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
18
|
Electrochemical Immunoassay for Tumor Marker CA19-9 Detection Based on Self-Assembled Monolayer. Molecules 2022; 27:molecules27144578. [PMID: 35889454 PMCID: PMC9324264 DOI: 10.3390/molecules27144578] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Revised: 07/12/2022] [Accepted: 07/17/2022] [Indexed: 12/10/2022] Open
Abstract
A CA19-9 electrochemical immunosensor was constructed using a hybrid self-assembled membrane modified with a gold electrode and applied to detect real samples. Hybrid self-assembled membranes were selected for electrode modification and used to detect antigens. First, the pretreated working electrodes were placed in a 3-mercaptopropionic acid (MPA)/β-mercaptoethanol (ME) mixture for 24 h for self-assembly. The electrodes were then placed in an EDC/NHS mixture for 1 h. Layer modification was performed by stepwise dropwise addition of CA19-9 antibody, BSA, and antigen. Differential pulse voltammetry was used to characterize this immunosensor preparation process. The assembled electrochemical immunosensor enables linear detection in the concentration range of 0.05–500 U/mL of CA19-9, and the detection limit was calculated as 0.01 U/mL. The results of the specificity measurement test showed that the signal change of the interfering substance was much lower than the response value of the detected antigen, indicating that the sensor has good specificity and strong anti-interference ability. The repeatability test results showed that the relative standard deviations were less than 5%, showing good accuracy and precision. The CA19-9 electrochemical immunosensor was used for the actual sample detection, and the experimental results of the standard serum addition method showed that the RSD values of the test concentrations were all less than 10%. The recoveries were 102.4–115.0%, indicating that the assay has high precision, good accuracy, and high potential application value.
Collapse
|
19
|
Sharma P, Chauhan R, Pande V, Basu T, Rajesh, Kumar A. Rapid sensing ofTilletia indica - Teliospore in wheat extractby apiezoelectric label free immunosensor. Bioelectrochemistry 2022; 147:108175. [PMID: 35749887 DOI: 10.1016/j.bioelechem.2022.108175] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 06/01/2022] [Accepted: 06/04/2022] [Indexed: 11/02/2022]
Abstract
'Tilletia indica', a fungal pathogen causes Karnal bunt disease in wheat. It has been renowned as a quarantine pest in more than 50 countries, therefore, urged a threat to wheat in the international market. To date, conventional methods employed to detect the disease involve the tentative identification of spores (teliospores) based on morphology. For effective and specific disease control, it is essential to get the specific protein of the analyte (teliospore) to target. In present study, a label-free immunosensor has been developed to detect Karnal bunt disease. A specifically synthesized anti-teliosporic monoclonal antibody (mAb) was immobilized on a self-assembled monolayer of 11-mercaptoundecanoic acid (11-MUA) to detect teliospore. All modified electrodes were morphologically characterized by scanning electron microscopy (SEM), atomic force microscopy(AFM), Fourier transform infra-red spectroscopy (FT-IR) techniques and analytically characterized by quartz crystal microbalance (QCM) and cyclic voltammetry (CV). The linearity range was 19 pg mL-1-10 ng mL-1, while the detection limit (LOD) was 4.4 pg mL-1 and 12.5 pg mL-1, respectively. The stability, reproducibility, and repeatability of the immunoelectrode was examined by CV, and found stable upto 18 days with negligible variation. The binding affinity (association constant (Ka)) of the developed immunoelectrode was 1.9 × 10-2 ng mL-1. The real sample has been tested in spiked wheat samples and found about 95-103 % recovery with 2.8-4.4 % relative error.
Collapse
Affiliation(s)
- Priyanka Sharma
- Department of Biotechnology, Kumaun University, Bhimtal Campus, Bhimtal, Nainital, Uttarakhand, 263136, India; Department of Molecular Biology and Genetic Engineering, College of Basic Sciences & Humanities, G.B. Pant University of Agriculture & Technology, Pant Nagar 263145, Uttarakhand, India.
| | - Ruchika Chauhan
- Department of Molecular Biology and Genetic Engineering, College of Basic Sciences & Humanities, G.B. Pant University of Agriculture & Technology, Pant Nagar 263145, Uttarakhand, India
| | - Veena Pande
- Department of Biotechnology, Kumaun University, Bhimtal Campus, Bhimtal, Nainital, Uttarakhand, 263136, India
| | - Tinku Basu
- Amity Centre for Nanomedicine, Amity University Uttar Pradesh, Noida 201303, India
| | - Rajesh
- CSIR- National Physical Laboratory, Dr. K.S. Krishnan Marg, New Delhi 110012, India
| | - Anil Kumar
- Department of Molecular Biology and Genetic Engineering, College of Basic Sciences & Humanities, G.B. Pant University of Agriculture & Technology, Pant Nagar 263145, Uttarakhand, India; Director Education, Rani Lakshmi Bai Central Agricultural University, Jhansi 284003, India.
| |
Collapse
|
20
|
Bagheri AR, Aramesh N, Chen J, Liu W, Shen W, Tang S, Lee HK. Polyoxometalate-based materials in extraction, and electrochemical and optical detection methods: A review. Anal Chim Acta 2022; 1209:339509. [PMID: 35569843 DOI: 10.1016/j.aca.2022.339509] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2021] [Revised: 01/12/2022] [Accepted: 01/14/2022] [Indexed: 02/07/2023]
Abstract
Polyoxometalates (POMs) as metal-oxide anions have exceptional properties like high negative charges, remarkable redox abilities, unique ligand properties and availability of organic grafting. Moreover, the amenability of POMs to modification with different materials makes them suitable as precursors to further obtain new composites. Due to their unique attributes, POMs and their composites have been utilized as adsorbents, electrodes and catalysts in extraction, and electrochemical and optical detection methods, respectively. A survey of the recent progress and developments of POM-based materials in these methods is therefore desirable, and should be of great interest. In this review article, POM-based materials, their properties as well as their identification methods, and analytical applications as adsorbents, electrodes and catalysts, and corresponding mechanisms of action, where relevant, are reviewed. Some current issues of the utilization of these materials and their future prospects in analytical chemistry are discussed.
Collapse
Affiliation(s)
| | - Nahal Aramesh
- Department of Chemistry, Isfahan University, Isfahan, 81746-73441, Iran
| | - Jisen Chen
- School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, 212003, Jiangsu Province, China
| | - Wenning Liu
- Department of Environmental Toxicology, University of California, Davis, CA, 95616, USA
| | - Wei Shen
- School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, 212003, Jiangsu Province, China
| | - Sheng Tang
- School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, 212003, Jiangsu Province, China.
| | - Hian Kee Lee
- Department of Chemistry, National University of Singapore, 3 Science Drive 3, 117543, Singapore.
| |
Collapse
|
21
|
Jahani PM, Aflatoonian MR, Rayeni RA, Di Bartolomeo A, Mohammadi SZ. Graphite carbon nitride-modified screen-printed electrode as a highly sensitive and selective sensor for detection of amaranth. Food Chem Toxicol 2022; 163:112962. [DOI: 10.1016/j.fct.2022.112962] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2022] [Revised: 03/12/2022] [Accepted: 03/22/2022] [Indexed: 12/27/2022]
|
22
|
Karimi-Maleh H, Darabi R, Shabani-Nooshabadi M, Baghayeri M, Karimi F, Rouhi J, Alizadeh M, Karaman O, Vasseghian Y, Karaman C. Determination of D&C Red 33 and Patent Blue V Azo dyes using an impressive electrochemical sensor based on carbon paste electrode modified with ZIF-8/g-C 3N 4/Co and ionic liquid in mouthwash and toothpaste as real samples. Food Chem Toxicol 2022; 162:112907. [PMID: 35271984 DOI: 10.1016/j.fct.2022.112907] [Citation(s) in RCA: 119] [Impact Index Per Article: 39.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2022] [Revised: 02/22/2022] [Accepted: 03/05/2022] [Indexed: 12/17/2022]
Abstract
Synthetic azo dyes are widely used in a variety of industries, but many of them pose a risk to human health, particularly when consumed in large quantities. As a result, their existence in products should be closely monitored. D&C red 33 and Patent Blue V are mostly used in cosmetics, especially in toothpaste and mouthwashes. A novel carbon paste electrode modified with ZIF-8/g-C3N4/Co nanocomposite and 1-methyl-3-butylimidazolium bromide as an ionic liquid was employed as a highly sensitive reproducible electrochemical sensor for the simultaneous determination of these common dyes. ZIF structure has unique properties such as high surface area, suitable conductivity, and excellent porosity. The electrochemical behavior of the suggested electrode was investigated by cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS). To characterize the synthesized nanocomposites, scanning electron microscopy (SEM), X-ray diffraction (XRD) and Fourier transform infrared spectroscopy (FTIR) were applied to investigate the structure of nanocomposites. Under the optimized conditions, the modified sensor offered a wide linear concentration range 0.08-10 μM (R2 = 0.9906) and 10-900 μM (R2 = 0.9932) with a low limit of detection of 0.034 μM. The value of diffusion coefficient (D), and the electron transfer coefficient (α) was calculated to be 310 × 10-5, and 0.9 respectively. This technique offered a successful performance for the determination of target analyte in the real samples with acceptable results between 96% and 107%.
Collapse
Affiliation(s)
- Hassan Karimi-Maleh
- School of Resources and Environment, University of Electronic Science and Technology of China, Chengdu, 611731, PR China; Department of Chemical Engineering, Quchan University of Technology, Quchan, Iran; Department of Chemical Sciences, University of Johannesburg, Doornfontein Campus, 2028, Johannesburg, South Africa.
| | - Rozhin Darabi
- Institute of Nano Science and Nano Technology, University of Kashan, Kashan, Iran; Department of Analytical Chemistry, Faculty of Chemistry, University of Kashan, Kashan, Iran
| | - Mehdi Shabani-Nooshabadi
- Institute of Nano Science and Nano Technology, University of Kashan, Kashan, Iran; Department of Analytical Chemistry, Faculty of Chemistry, University of Kashan, Kashan, Iran.
| | - Mehdi Baghayeri
- Department of Chemistry, Faculty of Science, Hakim Sabzevari University, Sabzevar, 397, Iran
| | - Fatemeh Karimi
- Department of Chemical Engineering, Quchan University of Technology, Quchan, Iran
| | - Jalal Rouhi
- Faculty of Physics, University of Tabriz, Tabriz, 51566, Iran
| | - Marzieh Alizadeh
- Pharmaceutical Sciences Research Center, Shiraz University of Medical Sciences, Shiraz, Iran; Laboratory of Basic Sciences, Mohammad Rasul Allah Research Tower, Shiraz University of Medical Sciences, Shiraz, 234567890, Iran
| | - Onur Karaman
- Department of Medical Imaging Techniques, Vocational School of Health Services, Akdeniz University, Antalya, 07070, Turkey
| | - Yasser Vasseghian
- Department of Chemistry, Soongsil University, Seoul, 06978, South Korea
| | - Ceren Karaman
- Department of Electricity and Energy, Vocational School of Technical Sciences, Akdeniz University, Antalya, 07070, Turkey.
| |
Collapse
|
23
|
Gheorghe DC, Ilie-Mihai RM, Stefan-van Staden RI, Lungu-Moscalu A, van Staden JKF. Fast screening method for early diagnostic of gastric cancer based on utilization of a chitosan - S-doped graphene - based needle stochastic sensors. J Pharm Biomed Anal 2022; 214:114725. [PMID: 35303648 DOI: 10.1016/j.jpba.2022.114725] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Revised: 03/05/2022] [Accepted: 03/10/2022] [Indexed: 12/26/2022]
Abstract
Needle stochastic sensors were developed for the assay of carbohydrate antigen 19-9 (CA 19-9) and carcinoembryonic antigen (CEA) in different biological samples (e.g., whole blood, tissues, urine, and saliva). Sulfur doped graphene powders were modified with chitosan; paraffin oil was added to form a homogeneous paste that was used as active side of the stochastic sensors. High sensitivities and low limits of determination were achieved for the assay of CA19-9 and CEA in biological samples. The validation of the proposed screening method (which is utilizing the stochastic sensors as screening tools) was made by using real biological samples obtained from confirmed patients with gastric cancer; very good correlations for the concentrations of CEA and CA19-9 were obtained using the needle stochastic sensors.
Collapse
Affiliation(s)
- Damaris-Cristina Gheorghe
- Laboratory of Electrochemistry and PATLAB, National Institute of Research for Electrochemistry and Condensed Matter, 202 Splaiul Independentei Str., 060021 Bucharest-6, Romania; Faculty of Applied Chemistry and Material Science, University Politehnica of Bucharest, Bucharest, Romania
| | - Ruxandra-Maria Ilie-Mihai
- Laboratory of Electrochemistry and PATLAB, National Institute of Research for Electrochemistry and Condensed Matter, 202 Splaiul Independentei Str., 060021 Bucharest-6, Romania.
| | - Raluca-Ioana Stefan-van Staden
- Laboratory of Electrochemistry and PATLAB, National Institute of Research for Electrochemistry and Condensed Matter, 202 Splaiul Independentei Str., 060021 Bucharest-6, Romania; Faculty of Applied Chemistry and Material Science, University Politehnica of Bucharest, Bucharest, Romania.
| | - Alexandrina Lungu-Moscalu
- Laboratory of Electrochemistry and PATLAB, National Institute of Research for Electrochemistry and Condensed Matter, 202 Splaiul Independentei Str., 060021 Bucharest-6, Romania
| | - Jacobus Koos Frederick van Staden
- Laboratory of Electrochemistry and PATLAB, National Institute of Research for Electrochemistry and Condensed Matter, 202 Splaiul Independentei Str., 060021 Bucharest-6, Romania
| |
Collapse
|
24
|
Koçak B, İpek Y. Electrochemical Detection of Ivermectin Used for the Treatment of COVID-19 with Glutardialdehyde-Modified Glassy Carbon Electrode. Electrocatalysis (N Y) 2022; 13:108-115. [PMID: 35003379 PMCID: PMC8728705 DOI: 10.1007/s12678-021-00704-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/24/2021] [Indexed: 12/20/2022]
Abstract
In this study, the surface of the glassy carbon electrode was modified with glutardialdehyde. The modified glassy carbon electrode showed electrocatalytic activity against ivermectin. The glassy carbon electrode modified with glutardialdehyde showed high sensitivity, selectivity, and stability in the determination of ivermectin. The peak current of glutardialdehyde oxidation obtained by differential pulse voltammetry decreased inversely with the ivermectin concentration. Ivermectin inhibited the oxidation reaction of glutardialdehyde and caused a decrease in current. This change made the analysis of ivermectin electrochemically possible. In order to demonstrate the applicability of the developed method in real samples, recovery studies were carried out in tap water and urine. The highest sensitivity (0.45 µA/((µmol·L-1)(cm2))) was achieved with urine sample and the lowest detection limit as 2.66 × 10-6 mol·L-1 was obtained with BRT solution sample. Graphical abstract
Collapse
Affiliation(s)
- Berna Koçak
- Department of Chemistry and Chemical Process Technologies, Vocational School of Tunceli, Munzur University, 62000 Tunceli, Turkey
- Rare Earth Elements Research and Application Center, Munzur University, 62000 Tunceli, Turkey
| | - Yeliz İpek
- Department of Chemistry and Chemical Process Technologies, Vocational School of Tunceli, Munzur University, 62000 Tunceli, Turkey
- Rare Earth Elements Research and Application Center, Munzur University, 62000 Tunceli, Turkey
| |
Collapse
|