1
|
Liu W, Wang H, Li P, Li C, Li D, He Z, Zhang Y, Huang J, Hua J, Xu R, Xia L, Guo Y, Sun X. Electrochemiluminescence detection of diazinon in vegetables based on the synergistic interaction of WO 3-x dots with Au@SiO 2 nanocapsules. Food Chem 2024; 447:139011. [PMID: 38492303 DOI: 10.1016/j.foodchem.2024.139011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2024] [Revised: 02/27/2024] [Accepted: 03/09/2024] [Indexed: 03/18/2024]
Abstract
In this work, a simple synthesis of low-toxicity transition metal material of WO3-x dots was used as a co-reactant with Au@SiO2 as a core-shell material and a signal amplification factor to collaboratively promote Ru(bpy)32+ electrochemiluminescence (ECL) for the construction of a highly sensitive aptasensor for the detection of diazinon (DZN) in vegetables. Electrodes modified with multi-walled carbon nanotubes-chitosan composite membranes (MWCNTs-CS) were used to load and immobilize more Ru(bpy)32+.can load more Ru(bpy)32+. WO3-x dots synthesized by a simple method showed excellent ECL efficiency as a novel co-reactant for Ru(bpy)32+. Under optimized conditions, this aptasensor for DZN has a wide detection range (10 pg mL-1 - 1 μg mL-1.) and a low detection limit (0.0197 ng L-1). The aptasensor has shown good results in the analysis of real samples in the experiment. This work provides a new approach to the construction of a novel electrochemiluminescence sensor for the detection of pesticides.
Collapse
Affiliation(s)
- Wenzheng Liu
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Haifang Wang
- Dongzhimen Hospital, Beijing University of Chinese Medicine, Beijing 100700, China
| | - Peisen Li
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Chengqiang Li
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Donghan Li
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Zhenying He
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Yuhao Zhang
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Jingcheng Huang
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Jin Hua
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Rui Xu
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Lianming Xia
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China.
| | - Yemin Guo
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China.
| | - Xia Sun
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| |
Collapse
|
2
|
Wang X, Jia C, Wang S, Dong Y. Coreactant-free strong Ru(bpy) 32+ ECL at ionic liquid modified electrode and its application in sensitive detection of glucose based on resonance energy transfer. Talanta 2024; 270:125584. [PMID: 38142614 DOI: 10.1016/j.talanta.2023.125584] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Revised: 12/18/2023] [Accepted: 12/20/2023] [Indexed: 12/26/2023]
Abstract
In this work, we have realized the strong anodic ECL emission of Ru(bpy)32+ at ionic liquid (N-butylpyridinium tetrafluoroborate) modified electrode without additional coreactant. Methylene blue (MB) could accept the energy of Ru(bpy)32+ ECL to construct resonance energy transfer (ECL-RET) system, leading to the decrease of ECL signal. In the presence of glucose oxidase, hydrogen peroxide generated from the oxidation process of glucose could oxidize MB and block the ECL-RET route, resulting in the recovery of ECL signal. As a consequence, the designed sensor showed outstanding performance for "signal-on" detection of glucose in the concentration range of 10 μM to 1 mM, and the detection limit was determined as 1.75 μM. Importantly, this study revealed new roles of ILs in the fabrication of coreactant-free ECL sensing, which might open up a promising route for the potential design and implement in clinical analysis.
Collapse
Affiliation(s)
- Xinyi Wang
- Institute of Engineering, School of Chemistry and Chemical Engineering, Anhui University of Technology, Maanshan, 243002, China.
| | - Changbo Jia
- Institute of Engineering, School of Chemistry and Chemical Engineering, Anhui University of Technology, Maanshan, 243002, China
| | - Shangbing Wang
- Institute of Engineering, School of Chemistry and Chemical Engineering, Anhui University of Technology, Maanshan, 243002, China.
| | - Yongping Dong
- Institute of Engineering, School of Chemistry and Chemical Engineering, Anhui University of Technology, Maanshan, 243002, China.
| |
Collapse
|
3
|
Shan X, Lu J, Li C, Wu Q, Li H, Yang S, Guo Y, Song Y, Li R, Tian L. Ultrasensitive solid-state electrochemiluminescence sensor based on lotus root shaped carbon fiber, CdSe QDs and Fe 3O 4 synergically amplify Ru(bpy) 32+ luminophore signal for detection of cyfluthrin. Mikrochim Acta 2024; 191:215. [PMID: 38512545 DOI: 10.1007/s00604-024-06283-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Accepted: 02/23/2024] [Indexed: 03/23/2024]
Abstract
An efficient and innovative electrochemiluminescence (ECL) sensor was developed for trace detection of cyfluthrin. The sensor utilized materials such as lotus root shaped carbon fiber (Co CNFs), cadmium selenide quantum dots (CdSe QDs), and Fe3O4 to amplify Ru(bpy)32+ signals. Co CNFs, with its large specific surface area and porosity, served the purpose of not only enhancing the stability of the sensor by fixing CdSe QDs and Ru(bpy)32+ on the Co CNFs/GCE, but also facilitating electron transfer. CdSe QDs was involved in the luminescence reaction and collaborated with Ru(bpy)32+ to enhance the sensor's sensitivity, while Fe3O4 promoted electron transfer in the system due to its large surface area. The solid-state ECL sensor achieved satisfactory signal under the synergistic action of these components. The ECL signal of the sensor was quenched by cyfluthrin, and a favorable linear relationship was observed between the sensor and cyfluthrin in the concentration range 1 × 10-12 to 1 × 10-6 M. The detection limit of the sensor was 3.3 × 10-13 M (S/N = 3). The utilization of lotus root shaped carbon fiber, CdSe QDs, and Fe3O4 in the Ru(bpy)32+ system demonstrated a synergistic effect for cyfluthrin detection, presenting a new approach for the rapid determination analysis of pesticide residues in foods.
Collapse
Affiliation(s)
- Xiangyu Shan
- College of Chemistry, Changchun Normal University, Changchun, 130032, People's Republic of China
| | - Juan Lu
- College of Chemistry, Changchun Normal University, Changchun, 130032, People's Republic of China.
| | - Chao Li
- College of Chemistry, Changchun Normal University, Changchun, 130032, People's Republic of China
| | - Qian Wu
- College of Chemistry, Changchun Normal University, Changchun, 130032, People's Republic of China
| | - Huiling Li
- College of Chemistry, Changchun Normal University, Changchun, 130032, People's Republic of China
| | - Shuning Yang
- College of Chemistry, Changchun Normal University, Changchun, 130032, People's Republic of China
| | - Yanjia Guo
- College of Chemistry, Changchun Normal University, Changchun, 130032, People's Republic of China
| | - Yujia Song
- College of Chemistry, Changchun Normal University, Changchun, 130032, People's Republic of China
| | - Ruidan Li
- College of Chemistry, Changchun Normal University, Changchun, 130032, People's Republic of China
| | - Li Tian
- College of Chemistry, Changchun Normal University, Changchun, 130032, People's Republic of China
| |
Collapse
|
4
|
Chi L, Zhang C, Wu X, Qian X, Sun H, He M, Guo C. Research Progress on Biomimetic Nanomaterials for Electrochemical Glucose Sensors. Biomimetics (Basel) 2023; 8:biomimetics8020167. [PMID: 37092419 PMCID: PMC10123724 DOI: 10.3390/biomimetics8020167] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2023] [Revised: 04/16/2023] [Accepted: 04/17/2023] [Indexed: 04/25/2023] Open
Abstract
Diabetes has become a chronic disease that necessitates timely and accurate detection. Among various detection methods, electrochemical glucose sensors have attracted much attention because of low cost, real-time detection, and simple and easy operation. Nonenzymatic biomimetic nanomaterials are the vital part in electrochemical glucose sensors. This review article summarizes the methods to enhance the glucose sensing performance of noble metal, transition metal oxides, and carbon-based materials and introduces biomimetic nanomaterials used in noninvasive glucose detection in sweat, tear, urine, and saliva. Based on these, this review provides the foundation for noninvasive determination of trace glucose for diabetic patients in the future.
Collapse
Affiliation(s)
- Lili Chi
- School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| | - Chunmei Zhang
- School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| | - Xuanyu Wu
- School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
- School of Environmental Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| | - Xianghao Qian
- School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| | - Hao Sun
- School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| | - Mengru He
- School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| | - Chunxian Guo
- School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| |
Collapse
|
7
|
Lu J, Shan X, Wu Q, Sun Z, Zhang X, Zhao Y, Tian L. Solid-state electrochemiluminescence sensor based on zeolitic imidazolate framework-67 electrospinning nanofibers for chlorpyrifos detection. Mikrochim Acta 2022; 189:298. [PMID: 35902435 DOI: 10.1007/s00604-022-05398-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Accepted: 06/23/2022] [Indexed: 01/31/2023]
Abstract
A novel solid-state electrochemiluminescence (ECL) sensor for chlorpyrifos (CPF) detection was constructed based on zeolitic imidazolate framework-67 electrospinning nanofibers (ZIF-67 NFs). Silver nanoparticles (Ag NPs), ZIF-67 NFs, tris(2,2'-bipyridyl) ruthenium(II) [Ru(bpy)32+], and Nafion were successively deposited on the surface of the electrode. Ag NPs played a role in promoting electron transfer, and ZIF-67 NFs played a role in fixing Ru(bpy)32+ and promoting electron transfer due to its large specific surface area and porosity. Nafion formed a film on the outermost layer of the electrode to further improve the stability of the system. Therefore, the modified electrode showed stable and obvious ECL signal in PBS solution containing 10 μL 0.01 M TprA (pH 8.0). CPF quenched the ECL signal of the system, and the quenching value was linear with the logarithm of CPF concentration in the range 1.0 × 10-13 to 1.0 × 10-6 M. The detection limit was 3.3 × 10-14 M (S/N = 3). In this study, ZIF-67 NFs were used as an ECL promoter for the first time, broadening the application range of ZIF-67 NFs.
Collapse
Affiliation(s)
- Juan Lu
- College of Chemistry, Changchun Normal University, Changchun, 130032, People's Republic of China.
| | - Xiangyu Shan
- College of Chemistry, Changchun Normal University, Changchun, 130032, People's Republic of China
| | - Qian Wu
- College of Chemistry, Changchun Normal University, Changchun, 130032, People's Republic of China
| | - Zhuo Sun
- College of Chemistry, Changchun Normal University, Changchun, 130032, People's Republic of China
| | - Xin Zhang
- College of Chemistry, Changchun Normal University, Changchun, 130032, People's Republic of China
| | - Yingjie Zhao
- College of Chemistry, Changchun Normal University, Changchun, 130032, People's Republic of China
| | - Li Tian
- College of Chemistry, Changchun Normal University, Changchun, 130032, People's Republic of China.
| |
Collapse
|