1
|
Xing X, Hu Q, Liu Y, Wang Y, Cheng H. Comparative analysis of the surface properties and corrosion resistance of Co-Cr dental alloys fabricated by different methods. J Prosthet Dent 2022; 127:497.e1-497.e11. [PMID: 34998583 DOI: 10.1016/j.prosdent.2021.11.019] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2021] [Revised: 11/19/2021] [Accepted: 11/19/2021] [Indexed: 11/15/2022]
Abstract
STATEMENT OF PROBLEMS The complex oral environment leads to the corrosion of dental alloy materials and the release of metal ions that may have a negative impact on health. Digital manufacturing is increasingly being used in dentistry, but whether digitally manufactured prostheses have better resistance to corrosion than traditional cast prostheses is unclear. PURPOSE The purpose of this in vitro study was to determine the surface properties and corrosion resistance of dental cobalt-chromium (Co-Cr) alloys fabricated by lost-wax casting (CAST), selective laser melting (SLM), and computer numerical control milling (CNC). MATERIAL AND METHODS The surface characteristics of the specimens were analyzed via scanning electron microscopy and energy-dispersive spectroscopy (SEM-EDS), metallurgical observation, and X-ray diffraction (XRD). For corrosion resistance, the specimens were immersed in artificial saliva at a pH 2.3 and 6.8 for 1, 4, and 7 weeks. Then, inductively coupled plasma-mass spectrometry (ICP-MS) was used to detect the main metal ion. Electrochemical impedance spectroscopy (EIS) was conducted based on a 3-electrode system to assess the electrochemical corrosion resistance. An ANOVA test was used to evaluate statistically significant differences among the groups (α=.05). RESULTS The SLM and CNC specimens showed more homogenous microstructures, less ion release at different times and pH, and more charge transfer resistance than CAST specimens. CONCLUSIONS Compared with casting, SLM-printing and CNC-milling have advantages in terms of surface properties and corrosion resistance.
Collapse
Affiliation(s)
- Xiaojie Xing
- Graduate student, Graduate Prosthodontics, Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Lab of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, Fujian, PR China
| | - Qin Hu
- Graduate student, Graduate Prosthodontics, Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Lab of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, Fujian, PR China
| | - Yuan Liu
- Graduate student, Graduate Prosthodontics, Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Lab of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, Fujian, PR China
| | - Yinghui Wang
- Researcher, Institute of Stomatology & Research Center of Dental Esthetics and Biomechanics, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, Fujian, PR China
| | - Hui Cheng
- Professor, Institute of Stomatology & Research Center of Dental Esthetics and Biomechanics, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, Fujian, PR China.
| |
Collapse
|
2
|
Javadi A, Solouk A, Haghbin Nazarpak M, Bagheri F. Surface engineering of titanium-based implants using electrospraying and dip coating methods. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2019; 99:620-630. [PMID: 30889737 DOI: 10.1016/j.msec.2019.01.027] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/13/2018] [Revised: 12/23/2018] [Accepted: 01/07/2019] [Indexed: 12/20/2022]
Abstract
Titanium and its alloys due to their low density, good mechanical and biological properties are of the most common orthopedic metals. One of the main challenges regarding to titanium implants is their loosening after long term implantation in patient's body. Many methods such as alteration in surface topography with focus on improving osseointegration or biocompatibility in overall are supposed to overcome this issue. In this research, titanium surface topography is altered via electrospraying a solution of titanium salt, carrier polymer (polyvinylpyrrolidone) and solvents. The dip coated samples in the same solution are prepared and investigated as control. The electrosprayed or dip coated samples were pyrolysised in furnace at 500 °C to remove polymeric components. Then the stabilized microstructures on the surfaces were evaluated via scanning electron microscopy (SEM), water contact angle (WCA) measurement, X-ray diffraction (XRD) and atomic force microscope (AFM). Also, in order to study the bioactivity of modified samples, they were immersed in simulated body fluid (SBF) and their precipitates were studied. The cellular investigations were done by studying the cell morphology, MTT and alkaline phosphatase (ALP) activity assays. The results showed improvement in bioactivity and cellular response for DP3 and SP15 more than other samples implying the promising potential of these two approaches for titanium implant surface modification.
Collapse
Affiliation(s)
- Akbar Javadi
- Department of Biomedical Engineering, Amirkabir University of Technology (Tehran Polytechnic), Tehran, Iran
| | - Atefeh Solouk
- Department of Biomedical Engineering, Amirkabir University of Technology (Tehran Polytechnic), Tehran, Iran.
| | - Masoumeh Haghbin Nazarpak
- New Technologies Research Center (NTRC), Amirkabir University of Technology (Tehran Polytechnic), Tehran, Iran.
| | - Fatemeh Bagheri
- Department of Biotechnology, Faculty of Chemical Engineering, Tarbiat Modares University, Tehran, Iran
| |
Collapse
|
3
|
Hamidi MFFA, Harun WSW, Samykano M, Ghani SAC, Ghazalli Z, Ahmad F, Sulong AB. A review of biocompatible metal injection moulding process parameters for biomedical applications. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2017; 78:1263-1276. [PMID: 28575965 DOI: 10.1016/j.msec.2017.05.016] [Citation(s) in RCA: 61] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/08/2016] [Revised: 04/30/2017] [Accepted: 05/04/2017] [Indexed: 01/07/2023]
Abstract
Biocompatible metals have been revolutionizing the biomedical field, predominantly in human implant applications, where these metals widely used as a substitute to or as function restoration of degenerated tissues or organs. Powder metallurgy techniques, in specific the metal injection moulding (MIM) process, have been employed for the fabrication of controlled porous structures used for dental and orthopaedic surgical implants. The porous metal implant allows bony tissue ingrowth on the implant surface, thereby enhancing fixation and recovery. This paper elaborates a systematic classification of various biocompatible metals from the aspect of MIM process as used in medical industries. In this study, three biocompatible metals are reviewed-stainless steels, cobalt alloys, and titanium alloys. The applications of MIM technology in biomedicine focusing primarily on the MIM process setting parameters discussed thoroughly. This paper should be of value to investigators who are interested in state of the art of metal powder metallurgy, particularly the MIM technology for biocompatible metal implant design and development.
Collapse
Affiliation(s)
- M F F A Hamidi
- Institute of Postgraduate Studies, Universiti Malaysia Pahang, Lebuhraya Tun Razak, 26300 Gambang, Kuantan, Pahang, Malaysia
| | - W S W Harun
- Green Research for Advanced Materials Laboratory, Human Engineering Group, Faculty of Mechanical Engineering, Universiti Malaysia Pahang, 26600 Pekan, Pahang, Malaysia.
| | - M Samykano
- Structural and Material Degradation Group, Faculty of Mechanical Engineering, Universiti Malaysia Pahang, 26600 Pekan, Pahang, Malaysia
| | - S A C Ghani
- Green Research for Advanced Materials Laboratory, Human Engineering Group, Faculty of Mechanical Engineering, Universiti Malaysia Pahang, 26600 Pekan, Pahang, Malaysia
| | - Z Ghazalli
- Green Research for Advanced Materials Laboratory, Human Engineering Group, Faculty of Mechanical Engineering, Universiti Malaysia Pahang, 26600 Pekan, Pahang, Malaysia
| | - F Ahmad
- Department of Mechanical Engineering, Universiti Teknologi PETRONAS, Malaysia
| | - A B Sulong
- Department of Mechanical & Materials Engineering, Faculty of Engineering & Built Environment, Universiti Kebangsaan Malaysia, 43600 UKM, Bangi, Malaysia
| |
Collapse
|
4
|
Asri RIM, Harun WSW, Samykano M, Lah NAC, Ghani SAC, Tarlochan F, Raza MR. Corrosion and surface modification on biocompatible metals: A review. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2017; 77:1261-1274. [PMID: 28532004 DOI: 10.1016/j.msec.2017.04.102] [Citation(s) in RCA: 216] [Impact Index Per Article: 27.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2016] [Accepted: 04/18/2017] [Indexed: 12/12/2022]
Abstract
Corrosion prevention in biomaterials has become crucial particularly to overcome inflammation and allergic reactions caused by the biomaterials' implants towards the human body. When these metal implants contacted with fluidic environments such as bloodstream and tissue of the body, most of them became mutually highly antagonistic and subsequently promotes corrosion. Biocompatible implants are typically made up of metallic, ceramic, composite and polymers. The present paper specifically focuses on biocompatible metals which favorably used as implants such as 316L stainless steel, cobalt-chromium-molybdenum, pure titanium and titanium-based alloys. This article also takes a close look at the effect of corrosion towards the implant and human body and the mechanism to improve it. Due to this corrosion delinquent, several surface modification techniques have been used to improve the corrosion behavior of biocompatible metals such as deposition of the coating, development of passivation oxide layer and ion beam surface modification. Apart from that, surface texturing methods such as plasma spraying, chemical etching, blasting, electropolishing, and laser treatment which used to improve corrosion behavior are also discussed in detail. Introduction of surface modifications to biocompatible metals is considered as a "best solution" so far to enhanced corrosion resistance performance; besides achieving superior biocompatibility and promoting osseointegration of biocompatible metals and alloys.
Collapse
Affiliation(s)
- R I M Asri
- Institute of Postgraduate Studies, Universiti Malaysia Pahang, Lebuhraya Tun Razak, Gambang, 26300 Kuantan, Pahang, Malaysia
| | - W S W Harun
- Green Research for Advanced Materials Laboratory, Human Engineering Group, Faculty of Mechanical Engineering, Universiti Malaysia Pahang, 26600 Pekan, Pahang, Malaysia.
| | - M Samykano
- Structural and Material Degradation Group, Faculty of Mechanical Engineering, Universiti Malaysia Pahang, 26600 Pekan, Pahang, Malaysia
| | - N A C Lah
- Structural and Material Degradation Group, Faculty of Mechanical Engineering, Universiti Malaysia Pahang, 26600 Pekan, Pahang, Malaysia
| | - S A C Ghani
- Green Research for Advanced Materials Laboratory, Human Engineering Group, Faculty of Mechanical Engineering, Universiti Malaysia Pahang, 26600 Pekan, Pahang, Malaysia
| | - F Tarlochan
- Department of Mechanical and Industrial Engineering, College of Engineering, Qatar University, Doha, Qatar
| | - M R Raza
- Department of Mechanical Engineering, COMSATS Institute of Information Technology, Sahiwal 57000, Pakistan
| |
Collapse
|
5
|
Andrei M, Galateanu B, Hudita A, Costache M, Osiceanu P, Calderon Moreno JM, Drob SI, Demetrescu I. Electrochemical comparison and biological performance of a new CoCrNbMoZr alloy with commercial CoCrMo alloy. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2015; 59:346-355. [PMID: 26652383 DOI: 10.1016/j.msec.2015.10.031] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/27/2015] [Revised: 09/20/2015] [Accepted: 10/11/2015] [Indexed: 12/21/2022]
Abstract
A new CoCrNbMoZr alloy, with Nb and Zr content is characterized from the point of view of surface features, corrosion resistance and biological performance in order to be proposed as dental restorative material. Its properties are discussed in comparison with commercial Heraenium CE alloy based on Co, Cr and Mo as well. The microstructure of both alloys was revealed by scanning electron microscopy (SEM). The composition and thickness of the alloy native passive films were identified by X-ray photoelectron spectroscopy (XPS). The surface characteristics were analyzed by atomic force microscopy (AFM) and contact angle techniques. The quantity of ions released from alloys in artificial saliva was evaluated with inductively coupled plasma-mass spectroscopy (ICP-MS) measurements. The electrochemical stability was studied in artificial Carter-Brugirard saliva, performing open circuit potentials, polarization resistances and corrosion currents and rates. The biological performance of the new alloy was tested in vitro in terms of human adipose stem cells (hASCs) morphology, viability and proliferation status. The new alloy is very resistant to the attack of the aggressive ions from the artificial saliva. The surface properties, the roughness and wettabiliy sustain the cell behavior. The comparison of the new alloy behavior with that of existing commercial CoCrMo alloy showed the superior properties of the new metallic biomaterial.
Collapse
Affiliation(s)
- M Andrei
- Department of General Chemistry, University Politehnica Bucharest, Spl. Independentei 313, 060042 Bucharest, Romania
| | - B Galateanu
- Department of Biochemistry and Molecular Biology, University of Bucharest, 91-95 Spl. Independentei, Bucharest 050095, Romania; Institute of Life Sciences, Vasile Goldis Western University of Arad, 86 Rebreanu, 310414 Arad, Romania
| | - A Hudita
- Department of General Chemistry, University Politehnica Bucharest, Spl. Independentei 313, 060042 Bucharest, Romania
| | - M Costache
- Department of Biochemistry and Molecular Biology, University of Bucharest, 91-95 Spl. Independentei, Bucharest 050095, Romania
| | - P Osiceanu
- Institute of Physical Chemistry "Ilie Murgulescu" of Romanian Academy, Spl. Independentei 202, 060021 Bucharest, Romania
| | - J M Calderon Moreno
- Institute of Physical Chemistry "Ilie Murgulescu" of Romanian Academy, Spl. Independentei 202, 060021 Bucharest, Romania
| | - S I Drob
- Institute of Physical Chemistry "Ilie Murgulescu" of Romanian Academy, Spl. Independentei 202, 060021 Bucharest, Romania.
| | - I Demetrescu
- Department of General Chemistry, University Politehnica Bucharest, Spl. Independentei 313, 060042 Bucharest, Romania
| |
Collapse
|
6
|
In situ electrochemical study of the interaction of cells with thermally treated titanium. Biointerphases 2015; 10:021006. [PMID: 25947388 DOI: 10.1116/1.4919778] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Micromotion and fretting wear between bone and Ti-based alloys in stem and dental implants breaks the passive film and exposes the metal to the action of the complex surrounding medium, generating substantial amounts of debris and continuous Ti ion release. In this work, oxidation treatments at low temperatures (277 °C, 5 h) have been used to promote the formation of wear-corrosion resistant titanium oxide on the Ti surface. The objective of this paper has been the study of the influence of live cells on the protectiveness of the oxide formed at these low temperatures. The interaction of cells with the modified surface has been studied by scanning electron microscopy, electrochemical impedance spectroscopy, polarization curves, and x-ray photoelectron spectroscopy (XPS). The chemical composition of the thermally treated Ti surface is mainly TiO2 as anatase-rich titanium dioxide with a low concentration of hydroxyl groups and a low mean nanoroughness that could promote good cell adhesion. The electrochemical results indicate that the cells alter the overall resistance of the thermally treated Ti surfaces by decreasing the oxide resistance with time. At the same time, the anodic current increases, which is associated with cathodic control, and is probably due to the difficulty of access of oxygen to the Ti substrate. XPS reveals the presence of proteins on the surface of the treated specimens in contact with the cells and a decrease in the Ti signal associated with the extracellular matrix on the surface and the reduction of the oxide thickness.
Collapse
|
7
|
Dumitriu C, Stoian AB, Titorencu I, Pruna V, Jinga VV, Latonen RM, Bobacka J, Demetrescu I. Electrospun TiO2 nanofibers decorated Ti substrate for biomedical application. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2014; 45:56-63. [DOI: 10.1016/j.msec.2014.08.055] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2014] [Revised: 07/22/2014] [Accepted: 08/29/2014] [Indexed: 12/17/2022]
|