1
|
Elancheziyan M, Lee S, Yoon TH, Singh M, Lee D, Won K. Disposable electrochemical sensors based on reduced graphene oxide/polyaniline/poly(alizarin red S)-modified integrated carbon electrodes for the detection of ciprofloxacin in milk. Mikrochim Acta 2024; 191:507. [PMID: 39098931 DOI: 10.1007/s00604-024-06578-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2024] [Accepted: 07/16/2024] [Indexed: 08/06/2024]
Abstract
An electrochemical sensor based on an electroactive nanocomposite was designed for the first time consisting of electrochemically reduced graphene oxide (ERGO), polyaniline (PANI), and poly(alizarin red S) (PARS) for ciprofloxacin (CIPF) detection. The ERGO/PANI/PARS-modified screen-printed carbon electrode (SPCE) was constructed through a three-step electrochemical protocol and characterized using FTIR, UV-visible spectroscopy, FESEM, CV, LSV, and EIS. The new electrochemical CIPF sensor demonstrated a low detection limit of 0.0021 μM, a broad linear range of 0.01 to 69.8 μM, a high sensitivity of 5.09 μA/μM/cm2, and reasonable selectivity and reproducibility. Moreover, the ERGO/PANI/PARS/SPCE was successfully utilized to determine CIPF in milk with good recoveries and relative standard deviation (< 5%), which were close to those with HPLC analysis.
Collapse
Affiliation(s)
- Mari Elancheziyan
- Department of Chemical and Biochemical Engineering, College of Engineering, Dongguk University-Seoul, 30 Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea
| | - Sooyeon Lee
- Department of Chemical and Biochemical Engineering, College of Engineering, Dongguk University-Seoul, 30 Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea
| | - Tae Hyun Yoon
- Department of Chemical and Biochemical Engineering, College of Engineering, Dongguk University-Seoul, 30 Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea
| | - Manisha Singh
- Department of Chemical and Biochemical Engineering, College of Engineering, Dongguk University-Seoul, 30 Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea
| | - Dogyeong Lee
- Department of Chemical and Biochemical Engineering, College of Engineering, Dongguk University-Seoul, 30 Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea
| | - Keehoon Won
- Department of Chemical and Biochemical Engineering, College of Engineering, Dongguk University-Seoul, 30 Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea.
| |
Collapse
|
2
|
Wang J, Xu Q, Yang Y, Liu J, Kong W, Shi L. An electrochemical sensor founded on heterogeneous MXene & MOF composite for tanshinol sensing. Talanta 2024; 268:125344. [PMID: 37918243 DOI: 10.1016/j.talanta.2023.125344] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Revised: 10/23/2023] [Accepted: 10/25/2023] [Indexed: 11/04/2023]
Abstract
A new kind of electrochemical sensor based on the MXene & MOF composite-modified carbon cloth was prepared firstly by self-assembly through hydrogen bonds, and then by air-annealing process for detection. The preparation processing introduced chemical bonds between MXene and MOF, which remarkably enhanced the electron transfer ability. Accordingly, combing the unique features of MXene and MOF themselves, the novel electrochemical sensor exhibited exceptional performance to detect tanshinol. Via differential pulse voltammetry, we could obtain a linear tanshinol concentration range of 0.08-8 μM and the limit of detection is 0.034 μM. Furthermore, this developed electrochemical sensor could determine concentrations of tanshinol in real Chinese herbal samples, confirming its practicability and reliability.
Collapse
Affiliation(s)
- Jing Wang
- Key Laboratory of Chinese Medicine Resources Conservation, State Administration of Traditional Chinese Medicine of the People's Republic of China, Engineering Research Center of Chinese Medicine Resource of Ministry of Education, Institute of Medicinal Plant Development, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, 100193, China
| | - Qingbin Xu
- Key Laboratory of Chinese Medicine Resources Conservation, State Administration of Traditional Chinese Medicine of the People's Republic of China, Engineering Research Center of Chinese Medicine Resource of Ministry of Education, Institute of Medicinal Plant Development, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, 100193, China
| | - Yang Yang
- Key Laboratory of Chinese Medicine Resources Conservation, State Administration of Traditional Chinese Medicine of the People's Republic of China, Engineering Research Center of Chinese Medicine Resource of Ministry of Education, Institute of Medicinal Plant Development, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, 100193, China
| | - Jinxin Liu
- Key Laboratory of Chinese Medicine Resources Conservation, State Administration of Traditional Chinese Medicine of the People's Republic of China, Engineering Research Center of Chinese Medicine Resource of Ministry of Education, Institute of Medicinal Plant Development, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, 100193, China.
| | - Weijun Kong
- School of Traditional Chinese Medicine, Capital Medical University, Beijing, 100069, China.
| | - Linchun Shi
- Key Laboratory of Chinese Medicine Resources Conservation, State Administration of Traditional Chinese Medicine of the People's Republic of China, Engineering Research Center of Chinese Medicine Resource of Ministry of Education, Institute of Medicinal Plant Development, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, 100193, China.
| |
Collapse
|
3
|
Mǎgeruşan L, Pogǎcean F, Soran ML, Pruneanu SM. Graphene-Based Electrochemical Sensing Platform for Rapid and Selective Ferulic Acid Quantification. Int J Mol Sci 2023; 24:16937. [PMID: 38069263 PMCID: PMC10707139 DOI: 10.3390/ijms242316937] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Revised: 11/27/2023] [Accepted: 11/28/2023] [Indexed: 12/18/2023] Open
Abstract
Due to the multitude of physiological functions, ferulic acid (FA) has a wide range of applications in the food, cosmetic, and pharmaceutical industries. Thus, the development of rapid, sensitive, and selective detection tools for its assay is of great interest. This study reports a new electroanalytical approach for the quantification of ferulic acid in commercial pharmaceutical samples using a sulphur-doped graphene-based electrochemical sensing platform. The few-layer graphene material (exf-SGR) was prepared by the electrochemical oxidation of graphite, at a low applied bias (5 V), in an inorganic salt mixture of Na2S2O3/(NH4)2SO4 (0.3 M each). According to the morpho-structural characterization of the material, it appears to have a high heteroatom doping degree, as proved by the presence of sulphur lines in the XRD pattern, and the C/S ratio was determined by XPS investigations to be 11.57. The electrochemical performances of a glassy carbon electrode modified with the exf-SGR toward FA detection were tested by cyclic voltammetry in both standard laboratory solutions and real sample analysis. The developed modified electrode showed a low limit of detection (30.3 nM) and excellent stability and reproducibility, proving its potential applicability as a viable solution in FA qualitative and quantitative analysis.
Collapse
Affiliation(s)
- Lidia Mǎgeruşan
- National Institute for Research and Development of Isotopic and Molecular Technologies, Donat Street, No. 67-103, 400293 Cluj-Napoca, Romania; (F.P.); (M.-L.S.); (S.-M.P.)
| | | | | | | |
Collapse
|
4
|
David IG, Popa DE, Buleandra M, Codreanu SN, Croitoru L, Iordache LA, Noor H. Voltammetric Investigation of Ferulic Acid at Disposable Pencil Graphite Electrode. MICROMACHINES 2023; 14:1951. [PMID: 37893389 PMCID: PMC10609049 DOI: 10.3390/mi14101951] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Revised: 10/12/2023] [Accepted: 10/17/2023] [Indexed: 10/29/2023]
Abstract
Ferulic acid (FA), a monohydroxycinnamic acid, is an antioxidant with multiple beneficial effects on human health, presenting also importance in the food and cosmetics industry. Its electrochemical behavior was investigated at the disposable and cost-effective pencil graphite electrode (PGE). Cyclic voltammetry emphasized its pH-dependent, diffusion-controlled oxidation. Using the optimized conditions (HB type PGE, Britton Robinson buffer pH 4.56) differential pulse and square-wave voltammetric techniques were applied for its quantitative determination in the range 4.00 × 10-7-1.00 × 10-3 mol/L FA. The developed methods were employed for the rapid and simple assessment of the FA content from a commercially available powder designed for cosmetic use.
Collapse
Affiliation(s)
- Iulia Gabriela David
- Department of Analytical Chemistry and Physical Chemistry, Faculty of Chemistry, University of Bucharest, Panduri Av. 90-92, District 5, 050663 Bucharest, Romania; (M.B.); (S.N.C.); (L.C.); (L.A.I.)
| | - Dana Elena Popa
- Department of Analytical Chemistry and Physical Chemistry, Faculty of Chemistry, University of Bucharest, Panduri Av. 90-92, District 5, 050663 Bucharest, Romania; (M.B.); (S.N.C.); (L.C.); (L.A.I.)
| | - Mihaela Buleandra
- Department of Analytical Chemistry and Physical Chemistry, Faculty of Chemistry, University of Bucharest, Panduri Av. 90-92, District 5, 050663 Bucharest, Romania; (M.B.); (S.N.C.); (L.C.); (L.A.I.)
| | - Silvia Nicoleta Codreanu
- Department of Analytical Chemistry and Physical Chemistry, Faculty of Chemistry, University of Bucharest, Panduri Av. 90-92, District 5, 050663 Bucharest, Romania; (M.B.); (S.N.C.); (L.C.); (L.A.I.)
| | - Lorelei Croitoru
- Department of Analytical Chemistry and Physical Chemistry, Faculty of Chemistry, University of Bucharest, Panduri Av. 90-92, District 5, 050663 Bucharest, Romania; (M.B.); (S.N.C.); (L.C.); (L.A.I.)
| | - Laura Andreea Iordache
- Department of Analytical Chemistry and Physical Chemistry, Faculty of Chemistry, University of Bucharest, Panduri Av. 90-92, District 5, 050663 Bucharest, Romania; (M.B.); (S.N.C.); (L.C.); (L.A.I.)
| | - Hassan Noor
- Department of Surgery, Faculty of Medicine, “Lucian Blaga” University Sibiu, Lucian Blaga Street 25, 550169 Sibiu, Romania;
- European Hospital Medlife-Polisano, Strada Izvorului 1A, 550169 Sibiu, Romania
| |
Collapse
|
5
|
Electrochemical Characterization of the Antioxidant Properties of Medicinal Plants and Products: A Review. Molecules 2023; 28:molecules28052308. [PMID: 36903553 PMCID: PMC10004803 DOI: 10.3390/molecules28052308] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Revised: 02/19/2023] [Accepted: 02/28/2023] [Indexed: 03/06/2023] Open
Abstract
Medicinal plants are an important source of bioactive compounds with a wide spectrum of practically useful properties. Various types of antioxidants synthesized in plants are the reasons for their application in medicine, phytotherapy, and aromatherapy. Therefore, reliable, simple, cost-effective, eco-friendly, and rapid methods for the evaluation of antioxidant properties of medicinal plants and products on their basis are required. Electrochemical methods based on electron transfer reactions are promising tools to solve this problem. Total antioxidant parameters and individual antioxidant quantification can be achieved using suitable electrochemical techniques. The analytical capabilities of constant-current coulometry, potentiometry, various types of voltammetry, and chrono methods in the evaluation of total antioxidant parameters of medicinal plants and plant-derived products are presented. The advantages and limitations of methods in comparison to each other and traditional spectroscopic methods are discussed. The possibility to use electrochemical detection of the antioxidants via reactions with oxidants or radicals (N- and O-centered) in solution, with stable radicals immobilized on the electrode surface, via oxidation of antioxidants on a suitable electrode, allows the study of various mechanisms of antioxidant actions occurring in living systems. Attention is also paid to the individual or simultaneous electrochemical determination of antioxidants in medicinal plants using chemically modified electrodes.
Collapse
|
6
|
Sun W, Sahin NE, Sun D, Wu X, Munoz C, Thakare J, Aulich T, Zhang J, Hou X, Oncel N, Pierce D, Zhao JX. One-Pot Synthesis of Ruthenium-Based Nanocatalyst Using Reduced Graphene Oxide as Matrix for Electrochemical Synthesis of Ammonia. ACS APPLIED MATERIALS & INTERFACES 2023; 15:1115-1128. [PMID: 36575897 DOI: 10.1021/acsami.2c18413] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Conventional ammonia production consumes significant energy and causes enormous carbon dioxide (CO2) emissions globally. To lower energy consumption and mitigate CO2 emissions, a facile, environmentally friendly, and cost-effective one-pot method for the synthesis of a ruthenium-based nitrogen reduction nanocatalyst has been developed using reduced graphene oxide (rGO) as a matrix. The nanocatalyst synthesis was based on a single-step simultaneous reduction of RuCl3 into ruthenium-based nanoparticles (Ru-based NPs) and graphene oxide (GO) into rGO using glucose as the reducing agent and stabilizer. The obtained ruthenium-based nanocatalyst with rGO as a matrix (Runano-based/rGO) has shown much higher catalytic activity at lower temperatures and pressures for ammonia synthesis than conventional iron catalysts. The rGO worked as a promising promoter for the electrochemical synthesis of ammonia due to its excellent electrical and thermal conductivity. The developed Runano-based/rGO nanocatalyst was characterized using transmission electron microscopy (TEM), high-resolution transmission electron microscopy (HRTEM), scanning electron microscopy (SEM), energy-dispersive spectroscopy (EDS), ultraviolet-visible (UV-vis) absorption spectroscopy, X-ray diffraction (XRD), Fourier-transform infrared spectroscopy (FT-IR), dynamic light scattering (DLS), inductively coupled plasma mass spectrometry (ICP-MS), and X-ray photoelectron spectroscopy (XPS). The results demonstrated that the size of the Ru-based NPs on the surface of rGO was 1.9 ± 0.2 nm and the ruthenium content was 25.03 wt %. Bulk electrolysis measurements were conducted on thin-layer electrodes at various cathodic potentials in a N2-saturated 0.1 M H2SO4 electrolyte at room temperature. From the chronoamperometric measurements, the maximum faradic efficiency (F.E.) of 2.1% for ammonia production on the nanostructured Runano-based/rGO electrocatalyst was achieved at a potential of -0.20 V vs reversible hydrogen electrode (RHE). This electrocatalyst has attained a superior ammonia production rate of 9.14 μg·h-1·mgcat.-1. The results demonstrate the feasibility of reducing N2 into ammonia under ambient conditions and warrant further exploration of the nanostructured Runano-based/rGO for electrochemical ammonia synthesis.
Collapse
|
7
|
Nanomaterials-based electrochemical sensors for the detection of natural antioxidants in food and biological samples: research progress. Mikrochim Acta 2022; 189:318. [PMID: 35931898 DOI: 10.1007/s00604-022-05403-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Accepted: 07/02/2022] [Indexed: 10/16/2022]
Abstract
Antioxidants are healthy substances that are beneficial to the human body and exist mainly in natural and synthetic forms. Among many kinds of antioxidants, the natural antioxidants have great applications in many fields such as food chemistry, medical care, and clinical application. In recent years, many efforts have been made for the determination of natural antioxidants. Nano-electrochemical sensors combining electrochemistry and nanotechnology have been widely used in the determination of natural antioxidants due to their unique advantages. Therefore, a large number of nanomaterials such as metal oxide, carbon materials, and conducting polymer have attracted much attention in the field of electrochemical sensors due to their good catalytic effect and stable performance. This review mainly introduces the construction of electrochemical sensors based on different nanomaterials, such as metallic nanomaterials, metal oxide nanomaterials, carbon nanomaterials, metal-organic frameworks, polymer nanomaterials, and other nanocomposites, and their application to the detection of natural antioxidants, including ascorbic acid, phenolic acids, flavonoid, tryptophan, citric acid, and other natural antioxidants. In the end, the limitations of the existing nano-sensing technology, the latest development trend, and the application prospect for various natural antioxidant substances are summarized and analyzed. We expect that this review will be helpful to researchers engaged in electrochemical sensors.
Collapse
|
8
|
Shao Y, Dong Y, Fan L, Xu W, Bin L, Wang L, Li D, Zhao S. A highly sensitive aptasensor based on 3D-rGO/AuNPs for Hg2+ determination using HCR amplification strategy triggered by T-Hg2+-T. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107290] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
9
|
Ziyatdinova GK, Zhupanova AS, Budnikov HC. Electrochemical Sensors for the Simultaneous Detection of Phenolic Antioxidants. JOURNAL OF ANALYTICAL CHEMISTRY 2022. [DOI: 10.1134/s1061934822020125] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
10
|
A molecularly imprinted polymer on reduced graphene oxide-gold nanoparticles modified screen-printed electrode for selective determination of ferulic acid in orange peels. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106339] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
11
|
Ziyatdinova GK, Guss EV, Morozova EV, Budnikov HC. An Electrode Based on Electropolymerized Sunset Yellow for the Simultaneous Voltammetric Determination of Chlorogenic and Ferulic Acids. JOURNAL OF ANALYTICAL CHEMISTRY 2021. [DOI: 10.1134/s1061934821030163] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
12
|
Moradi M, Azizi‐Lalabadi M, Motamedi P, Sadeghi E. Electrochemical determination of T 2 toxin by graphite/polyacrylonitrile nanofiber electrode. Food Sci Nutr 2021; 9:1171-1179. [PMID: 33598201 PMCID: PMC7866594 DOI: 10.1002/fsn3.2097] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2020] [Revised: 11/26/2020] [Accepted: 12/18/2020] [Indexed: 01/20/2023] Open
Abstract
Fabricating graphite electrode corrected with nanofiber by electrospinning as a considerable procedure for utilization in the fluid materials, milk, and syrup for detection of T2 mycotoxin is a significant technique. The modern biosensor was fabricated at normal degrees of room and utilized via buffer Britton-Robinson (B-R) in pH = 5 to refine the chemico-mechanical specifications. The electrochemical manner of the modified surface was surveyed using the scanning electron microscopy (SEM), cyclic voltammetry (CV), square wave voltammetry (SQWV), electrochemical impedance spectroscopy (EIS), and differential pulse voltammetry (DPV). The corrected electrode displayed a linear reply to T2 toxin in two distinct concentration ranges of 30-100 nM with correlation coefficients of 0.99. The greatest signals in the square wave spectrums for the B-R buffer created on the uttermost signals of the obtained streams were pH = 5 and 0.5 M of KNO3 for T2 toxin. The modified electrode has a big signal, broad dynamic concentration and high sensitivity and selectivity.
Collapse
Affiliation(s)
- Mona Moradi
- Department of Chemical Engineering‐ Food SciencesKermanshah Science and Research BranchIslamic Azad UniversityKermanshahIran
| | - Maryam Azizi‐Lalabadi
- Research Center for Environmental Determinants of Health (RCEDH)Kermanshah University of Medical SciencesKermanshahIran
| | - Parisa Motamedi
- Research Center for Environmental Determinants of Health (RCEDH)Kermanshah University of Medical SciencesKermanshahIran
| | - Ehsan Sadeghi
- Research Center for Environmental Determinants of Health (RCEDH)Kermanshah University of Medical SciencesKermanshahIran
| |
Collapse
|
13
|
Bounegru AV, Apetrei C. Development of a Novel Electrochemical Biosensor Based on Carbon Nanofibers-Gold Nanoparticles-Tyrosinase for the Detection of Ferulic Acid in Cosmetics. SENSORS (BASEL, SWITZERLAND) 2020; 20:E6724. [PMID: 33255463 PMCID: PMC7727797 DOI: 10.3390/s20236724] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Revised: 11/21/2020] [Accepted: 11/23/2020] [Indexed: 01/16/2023]
Abstract
The present paper deals with the electrochemical behavior of three types of sensors based on modified screen-printed electrodes (SPEs): a sensor based on carbon nanofibers (CNF/SPE), a sensor based on nanofibers of carbon modified with gold nanoparticles (CNF-GNP/SPE) and a biosensor based on nanofibers of carbon modified with gold nanoparticles and tyrosinase (CNF-GNP-Ty/SPE). To prepare the biosensor, the tyrosinase (Ty) was immobilized on the surface of the electrode already modified with carbon nanofibers and gold nanoparticles, by the drop-and-dry technique. The electrochemical properties of the three electrodes were studied by cyclic voltammetry in electroactive solutions, and the position and shape of the active redox peaks are according to the nature of the materials modifying the electrodes. In the case of ferulic acid, a series of characteristic peaks were observed, the processes being more intense for the biosensor, with the higher sensitivity and selectivity being due to the immobilization of tyrosinase, a specific enzyme for phenolic compounds. The calibration curve was subsequently created using CNF-GNP-Ty/SPE in ferulic acid solutions of various concentrations in the range 0.1-129.6 μM. This new biosensor allowed low values of the detection threshold and quantification limit, 2.89 × 10-9 mol·L-1 and 9.64 × 10-9 mol·L-1, respectively, which shows that the electroanalytical method is feasible for quantifying ferulic acid in real samples. The ferulic acid was quantitatively determined in three cosmetic products by means of the CNF-GNP-Ty/SPE biosensor. The results obtained were validated by means of the spectrometric method in the infrared range, the differences between the values of the ferulic acid concentrations obtained by the two methods being under 5%.
Collapse
Affiliation(s)
| | - Constantin Apetrei
- Department of Chemistry, Physics and Environment, Faculty of Sciences and Environment, “Dunărea de Jos” University of Galaţi, 47 Domnească Street, 800008 Galaţi, Romania;
| |
Collapse
|
14
|
Wada R, Takahashi S, Muguruma H. New perspective on ECE mechanism of monohydroxycinnamic acid oxidation with carbon nanotube electrode. Electrochim Acta 2020. [DOI: 10.1016/j.electacta.2020.136964] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
15
|
Forzato C, Vida V, Berti F. Biosensors and Sensing Systems for Rapid Analysis of Phenolic Compounds from Plants: A Comprehensive Review. BIOSENSORS 2020; 10:E105. [PMID: 32846992 PMCID: PMC7557957 DOI: 10.3390/bios10090105] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/13/2020] [Revised: 08/18/2020] [Accepted: 08/21/2020] [Indexed: 01/18/2023]
Abstract
Phenolic compounds are secondary metabolites frequently found in plants that exhibit many different effects on human health. Because of the relevant bioactivity, their identification and quantification in agro-food matrices as well as in biological samples are a fundamental issue in the field of quality control of food and food supplements, and clinical analysis. In this review, a critical selection of sensors and biosensors for rapid and selective detection of phenolic compounds is discussed. Sensors based on electrochemistry, photoelectrochemistry, fluorescence, and colorimetry are discussed including devices with or without specific recognition elements, such as biomolecules, enzymes and molecularly imprinted materials. Systems that have been tested on real matrices are prevalently considered but also techniques that show potential development in the field.
Collapse
Affiliation(s)
| | | | - Federico Berti
- Dipartimento di Scienze Chimiche e Farmaceutiche, Università degli Studi di Trieste, via Giorgieri 1, 34127 Trieste, Italy; (C.F.); (V.V.)
| |
Collapse
|
16
|
Voltammetric determination of phentolamine mesylate in pharmaceutical formulations at poly (4-aminobenzene sulfonic acid)-modified glassy carbon electrode. CHEMICAL PAPERS 2020. [DOI: 10.1007/s11696-020-01250-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
17
|
An ultrasensitive electroanalytical sensor based on MgO/SWCNTs- 1-Butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide paste electrode for the determination of ferulic acid in the presence sulfite in food samples. Microchem J 2020. [DOI: 10.1016/j.microc.2019.104572] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
18
|
Zhang C, Ren J, Xing Y, Cui M, Li N, Liu P, Wen X, Li M. Fabrication of hollow ZnO-Co3O4 nanocomposite derived from bimetallic-organic frameworks capped with Pd nanoparticles and MWCNTs for highly sensitive detection of tanshinol drug. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2020; 108:110214. [DOI: 10.1016/j.msec.2019.110214] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2019] [Revised: 09/05/2019] [Accepted: 09/16/2019] [Indexed: 12/31/2022]
|
19
|
Wang L, Peng X, Fu H, Huang C, Li Y, Liu Z. Recent advances in the development of electrochemical aptasensors for detection of heavy metals in food. Biosens Bioelectron 2019; 147:111777. [PMID: 31634804 DOI: 10.1016/j.bios.2019.111777] [Citation(s) in RCA: 121] [Impact Index Per Article: 20.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2019] [Revised: 10/05/2019] [Accepted: 10/08/2019] [Indexed: 01/12/2023]
Abstract
Heavy metal contamination in environment and food has attracted intensive attention from the public since it poses serious threats to ecological system and human health. Traditional detection methods for heavy metals such as atomic absorption spectrometry have a fairly low detection limit, but the methods have many limitations and disadvantages. Therefore, it is of significance to develop a rapid technology for real-time and online detection of heavy metals. The electrochemical aptasensor-based technology is promising in the detection of heavy metals with advantages of high sensitivity, specificity, and accuracy. Although its development is rapid, more researches should be carried out before this technology can be used for on-site detection. In this review, the origin, basic principles and development of electrochemical aptasensors are introduced. The applications of nanomaterials and electrochemical aptasensors for the detection of heavy metals (mainly mercury, lead, cadmium, and arsenic) are summarized. The research and application tendency of electrochemical aptasensors for detection of heavy metals are prospected.
Collapse
Affiliation(s)
- Liyuan Wang
- College of Food Science and Engineering, National Engineering Laboratory for Deep Process of Rice and Byproducts, Central South University of Forestry and Technology, Changsha, 41004, China
| | - Xianglian Peng
- College of Food Science and Engineering, National Engineering Laboratory for Deep Process of Rice and Byproducts, Central South University of Forestry and Technology, Changsha, 41004, China.
| | - Hongjun Fu
- College of Food Science and Engineering, National Engineering Laboratory for Deep Process of Rice and Byproducts, Central South University of Forestry and Technology, Changsha, 41004, China
| | - Chao Huang
- College of Environmental Science and Engineering, Central South University of Forestry and Technology, Changsha, 410004, China
| | - Yaping Li
- College of Food Science and Engineering, National Engineering Laboratory for Deep Process of Rice and Byproducts, Central South University of Forestry and Technology, Changsha, 41004, China
| | - Zhiming Liu
- College of Environmental Science and Engineering, Central South University of Forestry and Technology, Changsha, 410004, China; Department of Biology, Eastern New Mexico University, Portales, NM, 88130, USA
| |
Collapse
|
20
|
Badea M, di Modugno F, Floroian L, Tit DM, Restani P, Bungau S, Iovan C, Badea GE, Aleya L. Electrochemical strategies for gallic acid detection: Potential for application in clinical, food or environmental analyses. THE SCIENCE OF THE TOTAL ENVIRONMENT 2019; 672:129-140. [PMID: 30954811 DOI: 10.1016/j.scitotenv.2019.03.404] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/20/2019] [Revised: 03/10/2019] [Accepted: 03/25/2019] [Indexed: 04/15/2023]
Abstract
Polyphenols are important to human health thus making it interesting and necessary to identify and assess methods for their detection. Gallic acid (GA) is a well-known antioxidant compound, found in tea leaves, various fruits, fruit seeds and in fruit-derived foods and beverages. In this study, to electrochemically detect this compound and assess the potential for GA detection, different analytical conditions at pH values of 5.8, 7 and 8 were tried. Two types of device were used for GA detection: (1) Lazar ORP-146C reduction-oxidation microsensors, coupled with a Jenco device, for estimation of antioxidant capacities of different electroactive media, and (2) screen-printed carbon sensors coupled with a mobile PalmSens device using differential pulse voltammetry (qualitative and quantitative GA determination). These proposed methods were validated by analysing some real samples: wine, green tea, apple juice and serum fortified with GA. Detection was evaluated in terms of specific calibration curves, with low limit of detection (LOD) and limit of quantification (LOQ), low response time, and high sensitivities. The analytical characteristics obtained recommend these methods to be tested on more other types of real samples. Our proposed methods, used in the established conditions of pH, may have further application in other clinical, food or environmental samples analyses in which the results of total antioxidants contents are usually expressed in GA equivalents.
Collapse
Affiliation(s)
- Mihaela Badea
- Department of Fundamental, Prophylactic and Clinical Disciplines, Faculty of Medicine, Transilvania University of Brasov, Brasov 500039, Romania.
| | - Federico di Modugno
- Department of Pharmacological and Biomolecular Sciences, Faculty of Pharmacology Science, Universita Degli Studi di Milano, Milan 20133, Italy.
| | - Laura Floroian
- Department of Automation and Information Technology, Faculty of Electrical Engineering and Computer Sciences, Transylvania University of Brasov, Brasov 500039, Romania.
| | - Delia Mirela Tit
- Department of Pharmacy, Faculty of Medicine and Pharmacy, University of Oradea, Oradea 410028, Romania
| | - Patrizia Restani
- Department of Pharmacological and Biomolecular Sciences, Faculty of Pharmacology Science, Universita Degli Studi di Milano, Milan 20133, Italy.
| | - Simona Bungau
- Department of Pharmacy, Faculty of Medicine and Pharmacy, University of Oradea, Oradea 410028, Romania
| | - Ciprian Iovan
- Department of Preclinical Disciplines, Faculty of Medicine and Pharmacy, University of Oradea, Oradea 410028, Romania.
| | - Gabriela Elena Badea
- Department of Chemistry, Faculty of Sciences, University of Oradea, Oradea 410087, Romania.
| | - Lotfi Aleya
- Laboratoire Chrono-environnement, Université de Franche-Comté, Besançon, France.
| |
Collapse
|
21
|
A voltammetric carbon paste sensor modified with NiO nanoparticle and ionic liquid for fast analysis of p-nitrophenol in water samples. J Mol Liq 2019. [DOI: 10.1016/j.molliq.2019.04.084] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
22
|
Synergistical accumulation for electrochemical sensing of 1-hydroxypyrene on electroreduced graphene oxide electrode. Talanta 2019; 192:387-394. [PMID: 30348407 DOI: 10.1016/j.talanta.2018.08.042] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2018] [Revised: 08/03/2018] [Accepted: 08/12/2018] [Indexed: 12/27/2022]
|
23
|
Izadyar A, Hershberger JC, Rogers R. Voltammetric Assessment of Ions Transfer at Ionophore-Graphene Based Polymeric Membranes. ELECTROANAL 2018. [DOI: 10.1002/elan.201800535] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Anahita Izadyar
- Department of Chemistry and Physics; Arkansas State University; PO Box 419 State University, AR 72467 USA
| | - John C. Hershberger
- Department of Chemistry and Physics; Arkansas State University; PO Box 419 State University, AR 72467 USA
| | - Robert Rogers
- Department of Chemistry and Physics; Arkansas State University; PO Box 419 State University, AR 72467 USA
| |
Collapse
|
24
|
A novel electrochemical sensor based on poly(p-aminobenzene sulfonic acid)-reduced graphene oxide composite film for the sensitive and selective detection of levofloxacin in human urine. J Electroanal Chem (Lausanne) 2018. [DOI: 10.1016/j.jelechem.2018.04.008] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
25
|
Erady V, Mascarenhas RJ, Satpati AK, Detriche S, Mekhalif Z, Dalhalle J, Dhason A. Sensitive detection of Ferulic acid using multi-walled carbon nanotube decorated with silver nano-particles modified carbon paste electrode. J Electroanal Chem (Lausanne) 2017. [DOI: 10.1016/j.jelechem.2017.10.045] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
|
26
|
Qi Y, Bai J, Ding X, Zhang HM. Electrochemically Prepared Three-dimensional Porous Nitrogen-doped Graphene Modified Electrode for Non-enzymatic Detection of Hydrogen Peroxide. ELECTROANAL 2017. [DOI: 10.1002/elan.201700142] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Yamin Qi
- School of Chemistry and Chemical Engineering; Beijing Institute of Technology; Beijing 100081 China
| | - Jie Bai
- Department of Chemical and Biochemical Engineering; College of Chemistry and Chemical Engineering; Xiamen University; Xiamen 361005 Fujian China
| | - Xiaoteng Ding
- School of Chemistry and Chemical Engineering; Beijing Institute of Technology; Beijing 100081 China
| | - Hui-Min Zhang
- School of Chemistry and Chemical Engineering; Beijing Institute of Technology; Beijing 100081 China
| |
Collapse
|
27
|
Ya Y, Jiang C, Mo L, Li T, Xie L, He J, Tang L, Ning D, Yan F. Electrochemical Determination of Carbendazim in Food Samples Using an Electrochemically Reduced Nitrogen-Doped Graphene Oxide-Modified Glassy Carbon Electrode. FOOD ANAL METHOD 2016. [DOI: 10.1007/s12161-016-0708-y] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
|
28
|
Zeng Y, Zhu Z, Du D, Lin Y. Nanomaterial-based electrochemical biosensors for food safety. J Electroanal Chem (Lausanne) 2016. [DOI: 10.1016/j.jelechem.2016.10.030] [Citation(s) in RCA: 101] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
29
|
Ma X, Chen M, Wu Y, Li X, Zhang S. Studies on the Electrochemical Behavior of Chlorogenic Acid and Its Interaction with DNA at a Graphene Modified Electrode. INT J ELECTROCHEM SC 2016; 11:8499-8511. [DOI: 10.20964/2016.10.38] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2025]
|
30
|
Raj M, Gupta P, Thapliyal N, Goyal RN. A Novel Hybrid Nano-composite Grafted Electrochemically Reduced Graphene Oxide Based Sensor for Sensitive Determination of Efavirenz. ELECTROANAL 2016. [DOI: 10.1002/elan.201600397] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Mamta Raj
- Department of Chemistry; Indian Institute of Technology Roorkee; Roorkee - 247667 India
| | - Pankaj Gupta
- Department of Chemistry; Indian Institute of Technology Roorkee; Roorkee - 247667 India
| | - Neeta Thapliyal
- Department of Pharmaceutical Chemistry, College of Health Sciences; University of KwaZulu-Natal; Durban 4000 South Africa
| | - Rajendra N. Goyal
- Department of Chemistry; Indian Institute of Technology Roorkee; Roorkee - 247667 India
| |
Collapse
|
31
|
Ferreira Garcia L, Ribeiro Souza A, Sanz Lobón G, Dos Santos WTP, Alecrim MF, Fontes Santiago M, de Sotomayor RLÁ, de Souza Gil E. Efficient Enzyme-Free Biomimetic Sensors for Natural Phenol Detection. Molecules 2016; 21:molecules21081060. [PMID: 27529208 PMCID: PMC6273866 DOI: 10.3390/molecules21081060] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2016] [Revised: 08/04/2016] [Accepted: 08/09/2016] [Indexed: 12/05/2022] Open
Abstract
The development of sensors and biosensors based on copper enzymes and/or copper oxides for phenol sensing is disclosed in this work. The electrochemical properties were studied by cyclic and differential pulse voltammetry using standard solutions of potassium ferrocyanide, phosphate/acetate buffers and representative natural phenols in a wide pH range (3.0 to 9.0). Among the natural phenols herein investigated, the highest sensitivity was observed for rutin, a powerful antioxidant widespread in functional foods and ubiquitous in the plant kingdom. The calibration curve for rutin performed at optimum pH (7.0) was linear in a broad concentration range, 1 to 120 µM (r = 0.99), showing detection limits of 0.4 µM. The optimized biomimetic sensor was also applied in total phenol determination in natural samples, exhibiting higher stability and sensitivity as well as distinct selectivity for antioxidant compounds.
Collapse
Affiliation(s)
- Luane Ferreira Garcia
- Faculdade de Farmácia, Universidade Federal de Goiás, Goiânia, GO 74690-970, Brazil.
| | | | - Germán Sanz Lobón
- Instituto de Química, Universidade Federal de Goiás, Goiânia, GO 74690-970, Brazil.
| | - Wallans Torres Pio Dos Santos
- Departamento de Farmácia, Universidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM), Diamantina, MG 74690-970, Brazil.
| | | | | | | | - Eric de Souza Gil
- Faculdade de Farmácia, Universidade Federal de Goiás, Goiânia, GO 74690-970, Brazil.
| |
Collapse
|
32
|
Synergetic accumulation and simultaneous determination of naphthol isomers on electrochemically reduced graphene oxide modified electrode. J Electroanal Chem (Lausanne) 2016. [DOI: 10.1016/j.jelechem.2016.03.023] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
33
|
Tiwari JN, Vij V, Kemp KC, Kim KS. Engineered Carbon-Nanomaterial-Based Electrochemical Sensors for Biomolecules. ACS NANO 2016; 10:46-80. [PMID: 26579616 DOI: 10.1021/acsnano.5b05690] [Citation(s) in RCA: 278] [Impact Index Per Article: 30.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
The study of electrochemical behavior of bioactive molecules has become one of the most rapidly developing scientific fields. Biotechnology and biomedical engineering fields have a vested interest in constructing more precise and accurate voltammetric/amperometric biosensors. One rapidly growing area of biosensor design involves incorporation of carbon-based nanomaterials in working electrodes, such as one-dimensional carbon nanotubes, two-dimensional graphene, and graphene oxide. In this review article, we give a brief overview describing the voltammetric techniques and how these techniques are applied in biosensing, as well as the details surrounding important biosensing concepts of sensitivity and limits of detection. Building on these important concepts, we show how the sensitivity and limit of detection can be tuned by including carbon-based nanomaterials in the fabrication of biosensors. The sensing of biomolecules including glucose, dopamine, proteins, enzymes, uric acid, DNA, RNA, and H2O2 traditionally employs enzymes in detection; however, these enzymes denature easily, and as such, enzymeless methods are highly desired. Here we draw an important distinction between enzymeless and enzyme-containing carbon-nanomaterial-based biosensors. The review ends with an outlook of future concepts that can be employed in biosensor fabrication, as well as limitations of already proposed materials and how such sensing can be enhanced. As such, this review can act as a roadmap to guide researchers toward concepts that can be employed in the design of next generation biosensors, while also highlighting the current advancements in the field.
Collapse
Affiliation(s)
- Jitendra N Tiwari
- Center for Superfunctional Materials, Department of Chemistry, Ulsan National Institute of Science and Technology (UNIST) , Ulsan 689-798, Korea
| | - Varun Vij
- Center for Superfunctional Materials, Department of Chemistry, Ulsan National Institute of Science and Technology (UNIST) , Ulsan 689-798, Korea
| | - K Christian Kemp
- Center for Superfunctional Materials, Department of Chemistry, Ulsan National Institute of Science and Technology (UNIST) , Ulsan 689-798, Korea
| | - Kwang S Kim
- Center for Superfunctional Materials, Department of Chemistry, Ulsan National Institute of Science and Technology (UNIST) , Ulsan 689-798, Korea
| |
Collapse
|
34
|
Sun B, Gou Y, Xue Z, Zheng X, Ma Y, Hu F, Zhao W. Protections of bovine serum albumin protein from damage on functionalized graphene-based electrodes by flavonoids. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2016; 62:197-205. [PMID: 26952415 DOI: 10.1016/j.msec.2016.01.043] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/20/2015] [Revised: 12/08/2015] [Accepted: 01/15/2016] [Indexed: 01/07/2023]
Abstract
A sensitive electrochemical sensor based on bovine serum albumin (BSA)/poly (diallyldimethylammonium chloride) (PDDA) functionalized graphene nanosheets (PDDA-G) composite film modified glassy carbon electrode (BSA/PDDA-G/GCE) had been developed to investigate the oxidative protein damage and protections of protein from damage by flavonoids. The performance of this sensor was remarkably improved due to excellent electrical conductivity, strong adsorptive ability, and large effective surface area of PDDA-G. The BSA/PDDA-G/GCE displayed the greatest degree of BSA oxidation damage at 40 min incubation time and in the pH 5.0 Fenton reagent system (12.5 mM FeSO4, 50 mM H2O2). The antioxidant activities of four flavonoids had been compared by fabricated sensor based on the relative peak current ratio of SWV, because flavonoids prevented BSA damage caused by Fenton reagent and affected the BSA signal in a solution containing Co(bpy)3(3+). The sensor was characterized by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and scanning electron microscopy (SEM). UV-vis spectrophotometry and FTIR were also used to investigate the generation of hydroxyl radical and BSA damage, respectively. On the basis of results from electrochemical methods, the order of the antioxidant activities of flavonoids is as follows: (+)-catechin>kaempferol>apigenin>naringenin. A novel, direct SWV analytical method for detection of BSA damage and assessment of the antioxidant activities of four flavonoids was developed and this electrochemical method provided a simple, inexpensive and rapid detection of BSA damage and evaluation of the antioxidant activities of samples.
Collapse
Affiliation(s)
- Bolu Sun
- School of Pharmacy, Lanzhou University, Lanzhou 730000, China
| | - Yuqiang Gou
- Lanzhou Military Command Center for Disease Prevention and Control, Lanzhou 730000, China
| | - Zhiyuan Xue
- School of Pharmacy, Lanzhou University, Lanzhou 730000, China
| | - Xiaoping Zheng
- School of Pharmacy, Lanzhou University, Lanzhou 730000, China
| | - Yuling Ma
- School of Pharmacy, Lanzhou University, Lanzhou 730000, China
| | - Fangdi Hu
- School of Pharmacy, Lanzhou University, Lanzhou 730000, China.
| | - Wanghong Zhao
- Department of Stomatology, Nanfang Hospital, Southern Medical University, Guangzhou 51515, China.
| |
Collapse
|
35
|
Lee SC, Patil UM, Kim SJ, Ahn S, Kang SW, Jun SC. All-solid-state flexible asymmetric micro supercapacitors based on cobalt hydroxide and reduced graphene oxide electrodes. RSC Adv 2016. [DOI: 10.1039/c6ra06034j] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
All-solid-state flexible asymmetric micro supercapacitor was prepared based on Co(OH)2 and electrochemically reduced graphene oxide via photolithography and electrodeposition.
Collapse
Affiliation(s)
- Su Chan Lee
- Nano-Electro Mechanical Device Laboratory
- School of Mechanical Engineering
- Yonsei University
- Seoul 120-749
- South Korea
| | - U. M. Patil
- Nano-Electro Mechanical Device Laboratory
- School of Mechanical Engineering
- Yonsei University
- Seoul 120-749
- South Korea
| | - Sun Jun Kim
- Nano-Electro Mechanical Device Laboratory
- School of Mechanical Engineering
- Yonsei University
- Seoul 120-749
- South Korea
| | - Seokhoon Ahn
- Institute of Advanced Composite Materials
- Korea Institute of Science and Technology
- Jellabuk-do 565-905
- South Korea
| | | | - Seong Chan Jun
- Nano-Electro Mechanical Device Laboratory
- School of Mechanical Engineering
- Yonsei University
- Seoul 120-749
- South Korea
| |
Collapse
|
36
|
Zhang P, Gou YQ, Gao X, Bai RB, Chen WX, Sun BL, Hu FD, Zhao WH. The pharmacokinetic study of rutin in rat plasma based on an electrochemically reduced graphene oxide modified sensor. J Pharm Anal 2015; 6:80-86. [PMID: 29403966 PMCID: PMC5762451 DOI: 10.1016/j.jpha.2015.12.003] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2015] [Revised: 12/18/2015] [Accepted: 12/21/2015] [Indexed: 01/15/2023] Open
Abstract
An electrochemical method based on a directly electrochemically reduced graphene oxide (ERGO) film coated on a glassy carbon electrode (GCE) was developed for the rapid and convenient determination of rutin in plasma. ERGO was modified on the surface of GCE by one-step electro-deposition method. Electrochemical behavior of rutin on ERGO/GCE indicated that rutin underwent a surface-controlled quasi-reversible process and the electrochemical parameters such as charge transfer coefficient (α), electron transfer number (n) and electrode reaction standard rate constant (ks) were 0.53, 2 and 3.4 s−1, respectively. The electrochemical sensor for rutin in plasma provided a wide linear response range of 4.70×10−7−1.25×10−5 M with the detection limit (s/n=3) of 1.84×10−8 M. The assay was successfully used to the pharmacokinetic study of rutin. The pharmacokinetic parameters such as elimination rate half-life (t1/2), area under curve (AUC), and plasma clearance (CL) were calculated to be 3.345±0.647 min, 5750±656.0 µg min/mL, and 5.891±0.458 mL/min/kg, respectively. The proposed method utilized a small sample volume of 10 μL and had no complicated sample pretreatment (without deproteinization), which was simple, eco-friendly, and time- and cost-efficient for rutin pharmacokinetic studies.
Collapse
Affiliation(s)
- Pei Zhang
- School of Pharmacy, Lanzhou University, Lanzhou 730000, China
| | - Yu-Qiang Gou
- Lanzhou Military Command Center for Disease Prevention and Control, Lanzhou 730020, China
| | - Xia Gao
- School of Pharmacy, Lanzhou University, Lanzhou 730000, China
| | - Rui-Bin Bai
- School of Pharmacy, Lanzhou University, Lanzhou 730000, China
| | - Wen-Xia Chen
- School of Pharmacy, Lanzhou University, Lanzhou 730000, China
| | - Bo-Lu Sun
- School of Pharmacy, Lanzhou University, Lanzhou 730000, China
| | - Fang-Di Hu
- School of Pharmacy, Lanzhou University, Lanzhou 730000, China
| | - Wang-Hong Zhao
- Department of Stomatology, Nanfang Hospital, Southern Medical University, Guangzhou 510000, China
| |
Collapse
|
37
|
Ambolikar AS, Guin SK, Kasar U, Kamat J. Electrochemistry of actinide on electrochemically reduced graphene oxide: Electrocatalysis of Np(VI)O22+/Np(V)O2+ in nitric acid solution. Electrochim Acta 2015. [DOI: 10.1016/j.electacta.2015.10.094] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
38
|
Abdel-Hamid R, Newair EF. Voltammetric Determination of Ferulic Acid Using Polypyrrole-Multiwalled Carbon Nanotubes Modified Electrode with Sample Application. NANOMATERIALS 2015; 5:1704-1715. [PMID: 28347090 PMCID: PMC5304804 DOI: 10.3390/nano5041704] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/26/2015] [Accepted: 10/12/2015] [Indexed: 11/16/2022]
Abstract
A polypyrrole-multiwalled carbon nanotubes modified glassy carbon electrode-based sensor was devised for determination of ferulic acid (FA). The fabricated sensor was prepared electrochemically using cyclic voltammetry (CV) and characterized using CV and scanning electron microscope (SEM). The electrode shows an excellent electrochemical catalytic activity towards FA oxidation. Under optimal conditions, the anodic peak current correlates linearly to the FA concentration throughout the range of 3.32 × 10−6 to 2.59 × 10−5 M with a detection limit of 1.17 × 10−6 M (S/N = 3). The prepared sensor is highly selective towards ferulic acid without the interference of ascorbic acid. The sensor applicability was tested for total content determination of FA in a commercial popcorn sample and showed a robust functionality.
Collapse
Affiliation(s)
- Refat Abdel-Hamid
- Unit of Electrochemistry Applications (UEA), Chemistry Department, Faculty of Science, Sohag University, Sohag 82524, Egypt.
| | - Emad F Newair
- Unit of Electrochemistry Applications (UEA), Chemistry Department, Faculty of Science, Sohag University, Sohag 82524, Egypt.
| |
Collapse
|
39
|
Dago À, Navarro J, Ariño C, Díaz-Cruz JM, Esteban M. Carbon nanotubes and graphene modified screen-printed carbon electrodes as sensitive sensors for the determination of phytochelatins in plants using liquid chromatography with amperometric detection. J Chromatogr A 2015; 1409:210-7. [PMID: 26212803 DOI: 10.1016/j.chroma.2015.07.057] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2014] [Revised: 07/02/2015] [Accepted: 07/14/2015] [Indexed: 01/09/2023]
Abstract
Nanomaterials are of great interest for the development of electrochemical sensors. Multi-walled carbon nanotubes and graphene were used to modify the working electrode surface of different screen-printed carbon electrodes (SPCE) with the aim of improving the sensitivity of the SPCE and comparing it with the conventional glassy carbon electrode. To assay the usability of these sensors, a HPLC methodology with amperometric detection was developed to analyze several phytochelatins in plants of Hordeum vulgare and Glycine max treated with Hg(II) or Cd(II) giving detection limits in the low μmolL(-1) range. Phytochelatins are low molecular weight peptides with the general structure γ-(Glu-Cys)n-Gly (n=2-5) which are synthesized in plants in the presence of heavy metal ions. These compounds can chelate heavy metal ions by the formation of complexes which, are transported to the vacuoles, where the toxicity is not threatening. For this reason phytochelatins are essential in the detoxification of heavy metal ions in plants. The developed HPLC method uses a mobile phase of 1% of formic acid in water with KNO3 or NaCl (pH=2.00) and 1% of formic acid in acetonitrile. Electrochemical detection at different carbon-based electrodes was used. Among the sensors tested, the conventional glassy carbon electrode offers the best sensitivity although modification improves the sensitivity of the SPCE. Glutathione and several isoforms of phytochelatin two were found in plant extracts of both studied species.
Collapse
Affiliation(s)
- Àngela Dago
- Departament de Química Analítica, Facultat de Química, Universitat de Barcelona (UB), Martí i Franquès, 1-11, E-08028 Barcelona, Spain
| | - Javier Navarro
- Departament de Química Analítica, Facultat de Química, Universitat de Barcelona (UB), Martí i Franquès, 1-11, E-08028 Barcelona, Spain
| | - Cristina Ariño
- Departament de Química Analítica, Facultat de Química, Universitat de Barcelona (UB), Martí i Franquès, 1-11, E-08028 Barcelona, Spain.
| | - José Manuel Díaz-Cruz
- Departament de Química Analítica, Facultat de Química, Universitat de Barcelona (UB), Martí i Franquès, 1-11, E-08028 Barcelona, Spain
| | - Miquel Esteban
- Departament de Química Analítica, Facultat de Química, Universitat de Barcelona (UB), Martí i Franquès, 1-11, E-08028 Barcelona, Spain
| |
Collapse
|
40
|
Vilian ATE, Chen SM. Preparation of carbon nanotubes decorated with manganese dioxide nanoparticles for electrochemical determination of ferulic acid. Mikrochim Acta 2014. [DOI: 10.1007/s00604-014-1431-2] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|