1
|
Maafa IM. Potential of Zinc Oxide Nanostructures in Biosensor Application. BIOSENSORS 2025; 15:61. [PMID: 39852112 PMCID: PMC11763625 DOI: 10.3390/bios15010061] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2024] [Revised: 01/13/2025] [Accepted: 01/14/2025] [Indexed: 01/26/2025]
Abstract
The burgeoning field of biosensors has seen significant advancements with the induction of zinc oxide (ZnO) nanostructures, because of their unique structural, electrical, and optical properties. ZnO nanostructures provide numerous benefits for biosensor applications. Their superior electron mobility enables effective electron transfer between the bioreceptor and transducer, enhancing sensitivity and reducing detection limits. Furthermore, ZnO's biocompatibility and non-toxicity make it ideal for in vivo applications, reducing the chances of adverse biological responses. This review paper explores the prospects of ZnO nanostructures in the development of biosensors, focusing on their morphological and structural characteristics. Various synthesis techniques, that include sol-gel, sputtering, and chemical vapor deposition, were successfully employed to prepare different ZnO nanostructures, like nanorods, nanotubes, and nanowires. The various findings in this field underscore the efficacy of ZnO nanostructures in enhancing the specificity and sensitivity of biosensors, presenting a promising avenue for the advancement of point-of-care diagnostic devices.
Collapse
Affiliation(s)
- Ibrahim M Maafa
- Department of Chemical Engineering, College of Engineering and Computer Sciences, Jazan University, Jazan 45142, Saudi Arabia
| |
Collapse
|
2
|
Kumar P, S Dkhar D, Chandra P, Kayastha AM. Watermelon Derived Urease Immobilized Gold Nanoparticles-Graphene Oxide Transducer for Direct Detection of Urea in Milk Samples. ACS APPLIED BIO MATERIALS 2024; 7:6357-6370. [PMID: 39331047 DOI: 10.1021/acsabm.4c00846] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/28/2024]
Abstract
Urea contamination in milk poses significant health risks, including kidney failure, urinary tract obstruction, fluid loss, shock, and gastrointestinal bleeding. This highlights the need for sensitive, rapid, and reliable methods to detect traces amount of urea in milk. In this study, we designed an electrochemical transducer for urea detection by utilizing purified watermelon urease (Urs), gold nanoparticles (AuNPs), and graphene oxide (GO). The nanomaterials and biosensor probe were characterized using UV-vis spectroscopy, XPS, TEM, XRD, FTIR, AFM, CV, EIS, and DPV. The engineered probe (GCE/AuNPs/GO/Urs) demonstrated a broad linear detection range of 5 to 90 mg/dL and a low limit of detection (LOD) of 0.037 (±0.012) mg/dL (RSD < 3.7%). The biosensor was tested for potential interferents that may be present in adulterated milk and an exceptionally low coefficient of selectivity (ksel <0.1) was obtained. Evaluation of milk samples from a local dairy farm showed good recovery rates from 93.13% to. 98.79% (RSD < 4.28%, n = 3), indicating reliable detection capabilities. Stability tests confirmed the sensor's reproducibility and consistent performance. Additionally, a comparison study of the system was carried out using the purified watermelon urease and the commercially available urease. Herein, the results obtained using the sensor probe was finally validated with the gold standard method.
Collapse
Affiliation(s)
- Prince Kumar
- School of Biotechnology, Institute of Science, Banaras Hindu University, Varanasi 221005, Uttar Pradesh, India
| | - Daphika S Dkhar
- Laboratory of Bio-Physio Sensors and Nanobioengineering, School of Biochemical Engineering, Indian Institute of Technology (BHU), Varanasi 221005, Uttar Pradesh, India
| | - Pranjal Chandra
- Laboratory of Bio-Physio Sensors and Nanobioengineering, School of Biochemical Engineering, Indian Institute of Technology (BHU), Varanasi 221005, Uttar Pradesh, India
| | - Arvind M Kayastha
- School of Biotechnology, Institute of Science, Banaras Hindu University, Varanasi 221005, Uttar Pradesh, India
| |
Collapse
|
3
|
Keles G, Sifa Ataman E, Taskin SB, Polatoglu İ, Kurbanoglu S. Nanostructured Metal Oxide-Based Electrochemical Biosensors in Medical Diagnosis. BIOSENSORS 2024; 14:238. [PMID: 38785712 PMCID: PMC11117604 DOI: 10.3390/bios14050238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2024] [Revised: 05/03/2024] [Accepted: 05/07/2024] [Indexed: 05/25/2024]
Abstract
Nanostructured metal oxides (NMOs) provide electrical properties such as high surface-to-volume ratio, reaction activity, and good adsorption strength. Furthermore, they serve as a conductive substrate for the immobilization of biomolecules, exhibiting notable biological activity. Capitalizing on these characteristics, they find utility in the development of various electrochemical biosensing devices, elevating the sensitivity and selectivity of such diagnostic platforms. In this review, different types of NMOs, including zinc oxide (ZnO), titanium dioxide (TiO2), iron (II, III) oxide (Fe3O4), nickel oxide (NiO), and copper oxide (CuO); their synthesis methods; and how they can be integrated into biosensors used for medical diagnosis are examined. It also includes a detailed table for the last 10 years covering the morphologies, analysis techniques, analytes, and analytical performances of electrochemical biosensors developed for medical diagnosis.
Collapse
Affiliation(s)
- Gulsu Keles
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, 06560 Ankara, Türkiye;
| | - Elif Sifa Ataman
- Bioengineering Department, Manisa Celal Bayar University, 45140 Manisa, Türkiye; (E.S.A.); (S.B.T.)
| | - Sueda Betul Taskin
- Bioengineering Department, Manisa Celal Bayar University, 45140 Manisa, Türkiye; (E.S.A.); (S.B.T.)
| | - İlker Polatoglu
- Bioengineering Department, Manisa Celal Bayar University, 45140 Manisa, Türkiye; (E.S.A.); (S.B.T.)
| | - Sevinc Kurbanoglu
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, 06560 Ankara, Türkiye;
| |
Collapse
|
4
|
Sanko V, Şenocak A, Oğuz Tümay S, Demirbas E. A novel comparative study for electrochemical urea biosensor design: effect of different ferrite nanoparticles (MFe2O4, M: Cu, Co, Ni, Zn) in urease immobilized composite system. Bioelectrochemistry 2022; 149:108324. [DOI: 10.1016/j.bioelechem.2022.108324] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2022] [Revised: 11/07/2022] [Accepted: 11/08/2022] [Indexed: 11/13/2022]
|
5
|
Valiūnienė A, Kavaliauskaitė G, Virbickas P, Ramanavičius A. Prussian blue based impedimetric urea biosensor. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115473] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
6
|
Polyvinyl alcohol as a crucial omissible polymer to fabricate an impedimetric glucose biosensor based on hierarchical 3D-NPZnO/chitosan. Carbohydr Polym 2021; 266:118105. [DOI: 10.1016/j.carbpol.2021.118105] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2020] [Revised: 03/04/2021] [Accepted: 04/21/2021] [Indexed: 12/31/2022]
|
7
|
Mikani M, Rahmanian R. Sensitive Biosensor Based on Urease/In2O5Sn Nano-Coated Fluorinated SnO2 for Urea Detection in Blood Serum. JOURNAL OF ANALYTICAL CHEMISTRY 2021. [DOI: 10.1134/s1061934821080116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
8
|
Singh S, Sharma M, Singh G. Recent advancements in urea biosensors for biomedical applications. IET Nanobiotechnol 2021; 15:358-379. [PMID: 34694714 PMCID: PMC8675831 DOI: 10.1049/nbt2.12050] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Revised: 01/06/2021] [Accepted: 02/14/2021] [Indexed: 12/22/2022] Open
Abstract
The quick progress in health care technology as a recurrent measurement of biochemical factors such as blood components leads to advance development and growth in biosensor technology necessary for effectual patient concern. The review wok of authors present a concise information and brief discussion on the development made in the progress of potentiometric, field effect transistor, graphene, electrochemical, optical, polymeric, nanoparticles and nanocomposites based urea biosensors in the past two decades. The work of authors is also centred on different procedures/methods for detection of urea by using amperometric, potentiometric, conductometric and optical processes, where graphene, polymer etc. are utilised as an immobilised material for the fabrication of biosensors. Further, a comparative revision has been accomplished on various procedures of urea analysis using different materials-based biosensors, and it discloses that electrochemical and potentiometric biosensor is the most promise one among all, in terms of rapid response time, extensive shelf life and resourceful design.
Collapse
Affiliation(s)
- Saravjeet Singh
- Department of Biomedical EngineeringDeenbandhu Chhotu Ram University of Science and TechnologyMurthalSonepatIndia
| | - Minakshi Sharma
- Department of ZoologyMaharishi Dayanand UniversityRohtakHaryanaIndia
| | - Geeta Singh
- Department of Biomedical EngineeringDeenbandhu Chhotu Ram University of Science and TechnologyMurthalSonepatIndia
| |
Collapse
|
9
|
Dimensionally Stable Anode Based Sensor for Urea Determination via Linear Sweep Voltammetry. SENSORS 2021; 21:s21103450. [PMID: 34063448 PMCID: PMC8156184 DOI: 10.3390/s21103450] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Revised: 05/11/2021] [Accepted: 05/13/2021] [Indexed: 11/25/2022]
Abstract
Urea is an added value chemical with wide applications in the industry and agriculture. The release of urea waste to the environment affects ecosystem health despite its low toxicity. Online monitoring of urea for industrial applications and environmental health is an unaddressed challenge. Electroanalytical techniques can be a smart integrated solution for online monitoring if sensors can overcome the major barrier associated with long-term stability. Mixed metal oxides have shown excellent stability in environmental conditions with long lasting operational lives. However, these materials have been barely explored for sensing applications. This work presents a proof of concept that demonstrates the applicability of an indirect electroanalytical quantification method of urea. The use of Ti/RuO2-TiO2-SnO2 dimensional stable anode (DSA®) can provide accurate and sensitive quantification of urea in aqueous samples exploiting the excellent catalytic properties of DSA® on the electrogeneration of active chlorine species. The cathodic reduction of accumulated HClO/ClO− from anodic electrogeneration presented a direct relationship with urea concentration. This novel method can allow urea quantification with a competitive LOD of 1.83 × 10−6 mol L−1 within a linear range of 6.66 × 10−6 to 3.33 × 10−4 mol L−1 of urea concentration.
Collapse
|
10
|
Botewad SN, Gaikwad DK, Girhe NB, Thorat HN, Pawar PP. Urea biosensors: A comprehensive review. Biotechnol Appl Biochem 2021; 70:485-501. [PMID: 33847399 DOI: 10.1002/bab.2168] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Accepted: 04/02/2021] [Indexed: 01/11/2023]
Abstract
Present study is specially designed for the recent advances in biosensors to detect and quantify urea concentration. Urea (carbamide) is an organic compound made up of the carbonyl (C=O) functional group with two -NH2 groups having chemical formula CO (NH2 )2 . In nature, urea is found everywhere as the result of various processes, and in the human body, urea is an end product of nitrogen metabolism. An excessive concentration of urea in the human body is responsible for different critical diseases such as indigestion, acidity, ulcers, cancer, malfunctioning of kidneys, renal failure, urinary tract obstruction, dehydration, shock, burns, gastrointestinal bleeding, and so on. Moreover, below the normal level may cause hepatic failure, nephritic syndrome, cachexia, and so on. As well as in various fields such as fishery, dairy, food preservation, agriculture, and so on, urea is normally found and its detection is necessary. In urea biosensors, enzyme urease (Urs) is used as a bioreceptor element and retains its long last activity is the critical issue in front of the researcher. During recent decades, different nanoparticles (zinc oxide, nickel oxide, iron oxide, titanium dioxide, tin(IV) oxide, etc.), conducting polymer (polyaniline, polypyrrole, etc.), conducting polymer-nanoparticles composites, carbon materials (carbon nanotubes, graphene oxide, reduced graphene oxide graphene), and so on are used in urea biosensors. The main emphasis of the present study is to provide cumulative and comprehensive information about the sensing parameters of urea biosensors based on the materials used for enzyme immobilization. Besides this special task, this review provides a fruitful discussion on the basics of biosensors briefly for new and upcoming researchers. Thus, the present study may act as a gift for a large audience that come from different fields and are working in biosensors research.
Collapse
Affiliation(s)
- Sunil N Botewad
- Department of Physics, Dr. Babasaheb Ambedkar Marathwada University, Aurangabad, Maharashtra, India
| | | | - Nitin B Girhe
- Jawahar Science, Commerce and Arts College, Andoor, Tq. Tuljapur District, Osmanabad, India
| | - Hanuman N Thorat
- Department of Physics, Dr. Babasaheb Ambedkar Marathwada University, Aurangabad, Maharashtra, India
| | - Pravina P Pawar
- Department of Physics, Dr. Babasaheb Ambedkar Marathwada University, Aurangabad, Maharashtra, India
| |
Collapse
|
11
|
Abebe B, Ravikumar C, Zereffa EA, Naveen Kumar A, Murthy HCA. Photocatalytic and superior ascorbic acid sensor activities of PVA/Zn-Fe-Mn ternary oxide nanocomposite. INORG CHEM COMMUN 2021. [DOI: 10.1016/j.inoche.2020.108343] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
12
|
Alizadeh M, Azar PA, Mozaffari SA, Karimi-Maleh H, Tamaddon AM. A DNA Based Biosensor Amplified With ZIF-8/Ionic Liquid Composite for Determination of Mitoxantrone Anticancer Drug: An Experimental/Docking Investigation. Front Chem 2020; 8:814. [PMID: 33195033 PMCID: PMC7606923 DOI: 10.3389/fchem.2020.00814] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2020] [Accepted: 08/03/2020] [Indexed: 12/16/2022] Open
Abstract
An ultrasensitive DNA electrochemical biosensor based on the carbon paste electrode (CPE) amplified with ZIF-8 and 1-butyl-3-methylimidazolium methanesulfonate (BMIMS) was fabricated in this research. The DNA/BMIMS/ZIF-8/CPE was used for the selective determination of a mitoxantrone anticancer drug in aqueous solution, resulting in a good catalytic effect and a powerful ability for determining mitoxantrone. Also, the interaction of the mitoxantrone anticancer drug with guanine bases of ds-DNA was used as a powerful strategy in the suggested biosensor, which was confirmed with docking investigation. Docking study of mitoxantrone into the ds-DNA sequence showed the intercalative binding mode of mitoxantrone into the nitrogenous-based pairs of ds-DNA. The effective factors such as ds-DNA concentration, temperature, buffer types, and incubation time were also optimized for the fabricated mitoxantrone biosensor. The results showed that, under optimum conditions (T = 25°C; incubation time=12 min; pH= 4.8 acetate buffer solution and [DNA] = 50 mg/L), the DNA/BMIMS/ZIF-8/CPE could be used in mitoxantrone assay in a concentration ranging from 8.0 nM to 110 μM with a detection limit of 3.0 nM. In addition, recovery data between 99.18 and 102.08% were obtained for the determination of mitoxantrone in the injection samples using DNA/ZIF-8/BMIMF/CPE as powerful biosensors.
Collapse
Affiliation(s)
- Marzieh Alizadeh
- Department of Chemistry, Science and Research Branch, Islamic Azad University, Tehran, Iran
| | - Parviz Aberoomand Azar
- Department of Chemistry, Science and Research Branch, Islamic Azad University, Tehran, Iran
| | - Sayed Ahmad Mozaffari
- Department of Chemical Technologies, Iranian Research Organization for Science and Technology (IROST), Tehran, Iran
| | - Hassan Karimi-Maleh
- Laboratory of Nanotechnology, Department of Chemical Engineering, Quchan University of Technology, Quchan, Iran
| | - Ali-Mohammad Tamaddon
- Center for Nanotechnology in Drug Delivery, School of Pharmacy, Shiraz University of Medical Sciences, Shiraz, Iran
| |
Collapse
|
13
|
Ollé EP, Farré-Lladós J, Casals-Terré J. Advancements in Microfabricated Gas Sensors and Microanalytical Tools for the Sensitive and Selective Detection of Odors. SENSORS (BASEL, SWITZERLAND) 2020; 20:E5478. [PMID: 32987904 PMCID: PMC7583964 DOI: 10.3390/s20195478] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/17/2020] [Revised: 09/14/2020] [Accepted: 09/21/2020] [Indexed: 12/15/2022]
Abstract
In recent years, advancements in micromachining techniques and nanomaterials have enabled the fabrication of highly sensitive devices for the detection of odorous species. Recent efforts done in the miniaturization of gas sensors have contributed to obtain increasingly compact and portable devices. Besides, the implementation of new nanomaterials in the active layer of these devices is helping to optimize their performance and increase their sensitivity close to humans' olfactory system. Nonetheless, a common concern of general-purpose gas sensors is their lack of selectivity towards multiple analytes. In recent years, advancements in microfabrication techniques and microfluidics have contributed to create new microanalytical tools, which represent a very good alternative to conventional analytical devices and sensor-array systems for the selective detection of odors. Hence, this paper presents a general overview of the recent advancements in microfabricated gas sensors and microanalytical devices for the sensitive and selective detection of volatile organic compounds (VOCs). The working principle of these devices, design requirements, implementation techniques, and the key parameters to optimize their performance are evaluated in this paper. The authors of this work intend to show the potential of combining both solutions in the creation of highly compact, low-cost, and easy-to-deploy platforms for odor monitoring.
Collapse
Affiliation(s)
- Enric Perarnau Ollé
- Department of Mechanical Engineering, Polytechnical University of Catalonia (UPC), MicroTech Lab, Colom street 11, 08222 Terrassa, Spain; (J.F.-L.); (J.C.-T.)
- SEAT S.A., R&D Department in Future Urban Mobility Concepts, A-2, Km 585, 08760 Martorell, Spain
| | - Josep Farré-Lladós
- Department of Mechanical Engineering, Polytechnical University of Catalonia (UPC), MicroTech Lab, Colom street 11, 08222 Terrassa, Spain; (J.F.-L.); (J.C.-T.)
| | - Jasmina Casals-Terré
- Department of Mechanical Engineering, Polytechnical University of Catalonia (UPC), MicroTech Lab, Colom street 11, 08222 Terrassa, Spain; (J.F.-L.); (J.C.-T.)
| |
Collapse
|
14
|
Nogueira Pedroza Dias Mello HJ, Bueno PR, Mulato M. Comparing glucose and urea enzymatic electrochemical and optical biosensors based on polyaniline thin films. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2020; 12:4199-4210. [PMID: 32789344 DOI: 10.1039/d0ay01018a] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Analytical sensors that can detect chemical (including biological) analytes are becoming increasingly widespread within the field of analytical chemistry. More than this, in a world tending towards the 'internet-of-things', the miniaturization of such devices is becoming increasingly urgent. Accordingly, electrochemical methods that are simultaneously multiplexable and effective at a miniature scale are receiving much attention. In the present work, we compare the label-free electrochemical response of enzymatic biosensors with the response of their optical counterpart. As a proof-of-concept we compare the electrochemical impedimetric response and the first time described capacitive response of enzymatic biosensors to their optical reflectance response (measured in the visible region using a portable handset spectrophotometer). The target was the detection of glucose and urea. The chemical platform of the sensors was composed of enzymatically functionalized polyaniline thin films. Sensitivity, linearity, and the limit of detection were analyzed for both electrochemical and optical instrumental settings. We found that the impedimetric/capacitive electrochemical setup produced a response that was of a similar quality to the optical response (sensitivities of 10.7 ± 0.7, 7.4 ± 0.7 and 4.3 ± 0.2% per decade for impedimetric, capacitive and optical glucose biosensors, respectively) with a broader linear range (10-4 to 10-1 mol L-1 for both glucose and urea biosensors) and similar limit-of-detection in the range of 1 μmol L-1 within a relevant and practical diagnosis range for biomedical applications.
Collapse
Affiliation(s)
- Hugo José Nogueira Pedroza Dias Mello
- Department of Physics, Faculty of Philosophy, Sciences and Letters at Ribeirao Preto, University of Sao Paulo - USP, 14040-901, Ribeirao Preto, SP, Brazil.
| | | | | |
Collapse
|
15
|
Alizadeh M, Azar PA, Mozaffari SA, Karimi-Maleh H, Tamaddon AM. Evaluation of Pt,Pd-Doped, NiO-Decorated, Single-Wall Carbon Nanotube-Ionic Liquid Carbon Paste Chemically Modified Electrode: An Ultrasensitive Anticancer Drug Sensor for the Determination of Daunorubicin in the Presence of Tamoxifen. Front Chem 2020; 8:677. [PMID: 32974271 PMCID: PMC7466574 DOI: 10.3389/fchem.2020.00677] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2020] [Accepted: 06/30/2020] [Indexed: 12/11/2022] Open
Abstract
Measuring the concentration of anticancer drugs in pharmacological and biological samples is a very useful solution to investigate the effectiveness of these drugs in the chemotherapy process. A Pt,Pd-doped, NiO-decorated SWCNTs (Pt,Pd-NiO/SWCNTs) nanocomposite was synthesized using a one-pot procedure and combining chemical precipitation and ultrasonic sonochemical methods and subsequently characterized by TEM and EDS analysis methods. The analyses results showed the high purity and good distribution of elements and the ~10-nm diameter of the Pt,Pd-NiO nanoparticle decorated on the surface of the SWCNTs with a diameter of about 20-30 nm. Using a combination of Pt,Pd-NiO/SWCNTs and 1-butyl-2,3-dimethylimidazolium tetrafluoroborate (1B23DTFB) in a carbon paste (CP) matrix, Pt,Pd-NiO/SWCNTs/1B23DTFB/CP was fabricated as a highly sensitive analytical tool for the electrochemical determination of daunorubicin in the concentration range of 0.008-350 μM with a detection limit of 3.0 nM. Compared to unmodified CP electrodes, the electro-oxidation process of daunorubicin has undergone significant improvements in current (about 9.8 times increasing in current) and potential (about 110 mV) decreasing in potential). It is noteworthy that the designed sensor can well measure daunorubicin in the presence of tamoxifen (two breast anticancer drugs with a ΔE = 315 mV. According to the real sample analysis data, the Pt,Pd-NiO/SWCNTs/1B23DTFB/CP has proved to be a promising methodology for the analysis and measuring of daunorubicin and tamoxifen in real (e.g., pharmaceutical) samples.
Collapse
Affiliation(s)
- Marzieh Alizadeh
- Department of Chemistry, Science and Research Branch, Islamic Azad University, Tehran, Iran
| | - Parviz Aberoomand Azar
- Department of Chemistry, Science and Research Branch, Islamic Azad University, Tehran, Iran
| | - Sayed Ahmad Mozaffari
- Thin Layer and Nanotechnology Laboratory, Department of Chemical Technologies, Iranian Research Organization for Science and Technology (IROST), Tehran, Iran
| | - Hassan Karimi-Maleh
- Laboratory of Nanotechnology, Department of Chemical Engineering, Quchan University of Technology, Quchan, Iran
| | - Ali-Mohammad Tamaddon
- Center for Nanotechnology in Drug Delivery, School of Pharmacy, Shiraz University of Medical Sciences, Shiraz, Iran
| |
Collapse
|
16
|
Naderi Asrami P, Aberoomand Azar P, Saber Tehrani M, Mozaffari SA. Glucose Oxidase/Nano-ZnO/Thin Film Deposit FTO as an Innovative Clinical Transducer: A Sensitive Glucose Biosensor. Front Chem 2020; 8:503. [PMID: 32760694 PMCID: PMC7374262 DOI: 10.3389/fchem.2020.00503] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Accepted: 05/15/2020] [Indexed: 11/29/2022] Open
Abstract
In the present research, a new biocompatible electrode is proposed as a rapid and direct glucose biosensing technique that improves on the deficiencies of fast clinical devices in laboratory investigations. Nano-ZnO (nanostructured zinc oxide) was sputtered by reactive direct current magnetron sputtering system on a precovered fluorinated tin oxide (FTO) conductive layer. Spin-coated polyvinyl alcohol (PVA) at optimized instrumental deposition conditions was applied to prepare the effective medium for glucose oxidase enzyme (GOx) covalent immobilization through cyanuric chloride (GOx/nano-ZnO/PVA/FTO). The electrochemical behavior of glucose on the fabricated GOx/nano-ZnO/PVA/FTO biosensor was investigated by I-V techniques. In addition, field emission scanning electron microscopy and electrochemical impedance spectroscopy were applied to assess the morphology of the modified electrode surface. The I-V results indicated good sensitivity for glucose detection (0.041 mA per mM) within 0.2-20 mM and the limit of detection was 2.0 μM. We believe that such biodevices have good potential for tracing a number of biocompounds in biological fluids along with excellent accuracy, selectivity, and precise analysis. The fast response time of the fabricated GOx/nano-ZnO/PVA/FTO biosensor (less than 3 s) could allow most types of real-time analysis.
Collapse
Affiliation(s)
- Padideh Naderi Asrami
- Department of Chemistry, Science and Research Branch, Islamic Azad University, Tehran, Iran
| | - Parviz Aberoomand Azar
- Department of Chemistry, Science and Research Branch, Islamic Azad University, Tehran, Iran
| | - Mohammad Saber Tehrani
- Department of Chemistry, Science and Research Branch, Islamic Azad University, Tehran, Iran
| | - Sayed Ahmad Mozaffari
- Thin Layer and Nanotechnology Laboratory, Institute of Chemical Technology, Iranian Research Organization for Science and Technology (IROST), Tehran, Iran
| |
Collapse
|
17
|
Anodic characteristics and electrochemical machining of two typical γ-TiAl alloys and its quantitative dissolution model in NaNO3 solution. Electrochim Acta 2020. [DOI: 10.1016/j.electacta.2019.135429] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
|
18
|
Alev-Tuzuner B, Beyler-Cigil A, Vezir Kahraman M, Yarat A. PEG-based hydrogel-coated test strip for on-site urea determination. INT J POLYM MATER PO 2018. [DOI: 10.1080/00914037.2018.1482460] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Burcin Alev-Tuzuner
- Department of Basic Medical Sciences, Biochemistry, Faculty of Dentistry, Marmara University, Maltepe, Turkey, Istanbul
| | - Asli Beyler-Cigil
- Department of Chemistry, Faculty of Arts and Sciences, Marmara University, Goztepe, Turkey Istanbul
- Department of Chemistry, Faculty of Arts and Sciences, Amasya University, Amasya, Turkey
| | - Memet Vezir Kahraman
- Department of Chemistry, Faculty of Arts and Sciences, Marmara University, Goztepe, Turkey Istanbul
| | - Aysen Yarat
- Department of Basic Medical Sciences, Biochemistry, Faculty of Dentistry, Marmara University, Maltepe, Turkey, Istanbul
| |
Collapse
|
19
|
Water-based synthesis of ZnO nanoparticles via decomposition of a ternary zinc complex containing Schiff-base, chelating, and Phen ligands. J CHIN CHEM SOC-TAIP 2018. [DOI: 10.1002/jccs.201800055] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
20
|
Ghayedi Karimi K, Mozaffari SA, Ebrahimi M. Spin-coated ZnO-graphene nanostructure thin film as a promising matrix for urease immobilization of impedimetric urea biosensor. J CHIN CHEM SOC-TAIP 2018. [DOI: 10.1002/jccs.201800031] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Affiliation(s)
| | - Sayed Ahmad Mozaffari
- Thin Layer and Nanotechnology Laboratory, Department of Chemical Technology; Iranian Research Organization for Science and Technology (IROST); Tehran Iran
| | - Mahmoud Ebrahimi
- Department of Chemistry, Mashhad Branch; Islamic Azad University; Mashhad Iran
| |
Collapse
|
21
|
Selvarajan S, Suganthi A, Rajarajan M. A simple sonochemical approach to fabricate a urea biosensor based on zinc phthalocyanine/graphene oxide/urease bioelectrode. ULTRASONICS SONOCHEMISTRY 2018; 42:183-192. [PMID: 29429660 DOI: 10.1016/j.ultsonch.2017.11.030] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2017] [Revised: 11/20/2017] [Accepted: 11/21/2017] [Indexed: 06/08/2023]
Abstract
A novel zinc phthalocyanine/graphene oxide (ZnPh/GO) nanocomposite modified glassy carbon electrode (GCE) was prepared by using sonochemical approach and simple drop casting method. Urease (Urs) was used as the specific enzyme for urea detection and was physically immobilized onto the surface of ZnPh/GO nanocomposite. The fabricated ZnPh/GO/Urs matrix was successfully characterized by UV-vis-spectroscopy, FT-IR spectroscopy, scanning electron microscopy (SEM), raman spectrum, thermogravimetric analysis, cyclic voltammetric (CV) and amperometric techniques. The electrocatalytic performance of the ZnPh/GO/Urs electrode was investigated by urea biosensor. Our results demonstrate that the modified electrode has excellent electrocatalytic activity towards the sensing of urea in 0.1 M phosphate buffer solution (PBS, pH 7.2). The biosensor tolerated a wide linear concentration range for urea from 0.4 to 22 μM (R2 = 0.991), with a detection limit of 0.034 µM (S/N = 3). The ZnPh/GO/Urs bioectrode has several excellent properties, including a fast response time, high reproducibility and stability.
Collapse
Affiliation(s)
- Sekar Selvarajan
- PG & Research Department of Chemistry, Thiagarajar College, Madurai 625 009, Tamil Nadu, India
| | - Ayyadurai Suganthi
- PG & Research Department of Chemistry, Thiagarajar College, Madurai 625 009, Tamil Nadu, India; Mother Teresa Women's University, Kodaikanal 624 102, Tamil Nadu, India.
| | | |
Collapse
|
22
|
Moharamzadeh MR, Salar Amoli H, Rahmanian R, Mozaffari SA. Cu 2+
-doped ITO as a Novel Efficient, Transparent, and Fast-Response Transducer for Ammonia Sensing. J CHIN CHEM SOC-TAIP 2018. [DOI: 10.1002/jccs.201700319] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Affiliation(s)
- Mohamad Reza Moharamzadeh
- Thin Layer and Nanotechnology Lab, Department of Chemical Technology; Iranian Research Organization for Science and Technology (IROST), P.O. Box 33535-111; Tehran I. R. Iran
| | - Hossein Salar Amoli
- Thin Layer and Nanotechnology Lab, Department of Chemical Technology; Iranian Research Organization for Science and Technology (IROST), P.O. Box 33535-111; Tehran I. R. Iran
| | - Reza Rahmanian
- Young Researchers and Elite Club, North Tehran Branch; Islamic Azad University; Tehran Iran
| | - Seyed Ahmad Mozaffari
- Thin Layer and Nanotechnology Lab, Department of Chemical Technology; Iranian Research Organization for Science and Technology (IROST), P.O. Box 33535-111; Tehran I. R. Iran
| |
Collapse
|
23
|
Naderi Asrami P, Saber Tehrani M, Aberoomand Azar P, Mozaffari SA. Impedimetric glucose biosensor based on nanostructure nickel oxide transducer fabricated by reactive RF magnetron sputtering system. J Electroanal Chem (Lausanne) 2017. [DOI: 10.1016/j.jelechem.2017.07.052] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
24
|
Gasparotto G, Costa JPC, Costa PI, Zaghete MA, Mazon T. Electrochemical immunosensor based on ZnO nanorods-Au nanoparticles nanohybrids for ovarian cancer antigen CA-125 detection. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2017; 76:1240-1247. [DOI: 10.1016/j.msec.2017.02.031] [Citation(s) in RCA: 51] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2016] [Revised: 11/30/2016] [Accepted: 02/07/2017] [Indexed: 10/20/2022]
|
25
|
Yang G, Liang B, Zhu Q, Hu Y, Ye X. Comprehensive Study of the Effects of Nanopore Structures on Enzyme Activity for the Enzyme Based Electrochemical Biosensors Based on Molecular Simulation. J Phys Chem A 2016; 120:10043-10056. [DOI: 10.1021/acs.jpca.6b10206] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Guang Yang
- Biosensor National Special Laboratory, College of Biomedical Engineering and Instrument Science, ‡Cyrus Tang Center for Sensor Materials and Applications, and §State Key Laboratory of CAD & CG, Zhejiang University, Hangzhou 310027, P. R. China
| | - Bo Liang
- Biosensor National Special Laboratory, College of Biomedical Engineering and Instrument Science, ‡Cyrus Tang Center for Sensor Materials and Applications, and §State Key Laboratory of CAD & CG, Zhejiang University, Hangzhou 310027, P. R. China
| | - Qin Zhu
- Biosensor National Special Laboratory, College of Biomedical Engineering and Instrument Science, ‡Cyrus Tang Center for Sensor Materials and Applications, and §State Key Laboratory of CAD & CG, Zhejiang University, Hangzhou 310027, P. R. China
| | - Yichuan Hu
- Biosensor National Special Laboratory, College of Biomedical Engineering and Instrument Science, ‡Cyrus Tang Center for Sensor Materials and Applications, and §State Key Laboratory of CAD & CG, Zhejiang University, Hangzhou 310027, P. R. China
| | - Xuesong Ye
- Biosensor National Special Laboratory, College of Biomedical Engineering and Instrument Science, ‡Cyrus Tang Center for Sensor Materials and Applications, and §State Key Laboratory of CAD & CG, Zhejiang University, Hangzhou 310027, P. R. China
| |
Collapse
|