1
|
Su L, Liu W, Wang Y, Jiang Y, Li Z, Wang M, Liu G. Corrosion behavior, antibacterial properties and in vitro and in vivo biocompatibility of biodegradable Zn-5Cu-xMg alloy for bone-implant applications. BIOMATERIALS ADVANCES 2024; 165:214000. [PMID: 39208498 DOI: 10.1016/j.bioadv.2024.214000] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/27/2024] [Revised: 08/10/2024] [Accepted: 08/17/2024] [Indexed: 09/04/2024]
Abstract
Reasonable optimization of degradation rate, antibacterial performance and biocompatibility is crucial for the development of biodegradable zinc alloy medical implant devices with antibacterial properties. In this study, various amounts of Mg elements were incorporated into Zn5Cu alloy to modulate the degradation rate, antibacterial properties and biocompatibility. The effects of Mg contents on the microstructure, corrosion behavior, antibacterial properties and biocompatibility of Zn-5Cu-xMg alloy were extensively investigated. The results revealed that with an increase of Mg content, the amount of Mg2Zn11 phase increased and its galvanic effect with the Zn matrix was enhanced, which accelerated the corrosion process and led to higher corrosion rate and high degradation rate of the alloy. Additionally, there was an increased release of Mg2+ and Zn2+ ions from the alloy which imparted excellent resistance against Escherichia coli and Staphylococcus aureus bacteria and improved biocompatibility, subcutaneous antibacterial and immune microenvironment regulation properties. Zn-5Cu-2 Mg exhibited superior antibacterial ability, cell compatibility, proliferation effect, subcutaneous antibacterial and immune microenvironment regulation performances, which can work as a promising candidate of biodegradable antibacterial medical implants.
Collapse
Affiliation(s)
- Lin Su
- School of Materials Science and Engineering, Central South University, Changsha 410083, China
| | - Wenbin Liu
- Department of Orthopaedics, The Third Xiangya Hospital, Central South University, 138 Tongzipo Road, Changsha 410008, China; Hunan Engineering Research Center of Biomedical Metal and Ceramic Implants, Changsha, China
| | - Yanggang Wang
- School of Materials Science and Engineering, Central South University, Changsha 410083, China
| | - Yanbin Jiang
- School of Materials Science and Engineering, Central South University, Changsha 410083, China; State Key Lab for Powder Metallurgy, Central South University, Changsha 410083, China.
| | - Zhou Li
- School of Materials Science and Engineering, Central South University, Changsha 410083, China; State Key Lab for Powder Metallurgy, Central South University, Changsha 410083, China
| | - Meng Wang
- School of Materials Science and Engineering, Central South University, Changsha 410083, China
| | - Gengyan Liu
- Department of Orthopaedics, The Third Xiangya Hospital, Central South University, 138 Tongzipo Road, Changsha 410008, China.
| |
Collapse
|
2
|
Palai D, Roy T, De A, Mukherjee S, Bandyopadhyay S, Dhara S, Das S, Das K. Study on the Bioactivity Response of the Newly Developed Zn-Cu-Mn/Mg Alloys for Biodegradable Implant Application. ACS Biomater Sci Eng 2024. [PMID: 39230934 DOI: 10.1021/acsbiomaterials.4c00082] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/05/2024]
Abstract
Scaffolds play a crucial role in bone tissue engineering to support the defect area through bone regeneration and defect reconstruction. Promising tissue regeneration without negative repercussions and avoidance of the lifelong presence inside the body make bioresorbable metals prosper in the field of regenerative medicine. Recently, Zn and its alloys have emerged as promising biodegradable materials for their moderate degradation rate and satisfactory biocompatibility. Nevertheless, it is very challenging for cells to adhere and grow over the Zn surface alone, which influences the tissue-implant integration. In this study, an attempt has been made to systematically investigate the bioactivity responses in terms of in vitro hemocompatibility, cytotoxicity, antibacterial activity, and in vivo biocompatibility of newly developed Zn-2Cu-0.5Mn/Mg alloy scaffolds with different surface roughness. The rough surface of Zn-2Cu-0.5Mg shows the highest degradation rate of 0.16 mm/yr. The rough surface exhibits a prominent role in the adsorption of protein, further enhancing cell adhesion. Concentration-dependent alloy extract shows the highest cell proliferation for 12.5% of the extract with a maximum cell viability of 101% in Zn-2Cu-0.5Mn and 108% in Zn-2Cu-0.5Mg after 3 d. Acceptable hemolysis percentages (less than 5%) with promising anticoagulation properties are observed for all of the conditions. Enhanced antibacterial (Staphylococcus aureus and Escherichia coli) activity due to a significant effect of ions illustrates the maximum killing effect on the bacterial colony for the rough Zn-2Cu-0.5Mg alloy. In addition, it is observed that for rough Zn-2Cu-0.5Mn/Mg alloys, the inflammatory response is minimal after subcutaneous implantation, and neo-bone tissue forms in the defect areas of the rat femur with satisfactory biosafety response. The osseointegration property of the Zn-2Cu-0.5Mg alloy is comparable to that of the Zn-2Cu-0.5Mn alloy. Therefore, the rough surface of the Zn-2Cu-0.5Mg alloy has the potential to enhance biocompatibility and promote better osseointegration activity with host tissues for various biomedical applications.
Collapse
Affiliation(s)
- Debajyoti Palai
- Department of Metallurgical and Materials Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Trina Roy
- School of Medical Science and Technology, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Amiyangshu De
- Advanced Technology Development Centre, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Sayan Mukherjee
- School of Medical Science and Technology, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Sharba Bandyopadhyay
- Department of Electronics and Electrical Communication Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Santanu Dhara
- School of Medical Science and Technology, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Siddhartha Das
- Department of Metallurgical and Materials Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Karabi Das
- Department of Metallurgical and Materials Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| |
Collapse
|
3
|
Palai D, Siva Prasad P, Satpathy B, Das S, Das K. Development of Zn-2Cu- xMn/Mg Alloys for Orthopedic Applications: Mechanical Performance to In Vitro Degradation under Different Physiological Environments. ACS Biomater Sci Eng 2023; 9:6058-6083. [PMID: 37774322 DOI: 10.1021/acsbiomaterials.3c00641] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/01/2023]
Abstract
Zinc (Zn) and its alloys are considered futuristic biodegradable materials for their acceptable mechanical properties, suitable corrosion rate, and good biocompatibility. In this study, we report newly developed biodegradable Zn-2Cu-xMn/Mg (x = 0, 0.1, and 0.5) alloys, aiming to achieve good mechanical strength with excellent elongation, desirable wear resistance, and suitable corrosion rate. The effect of Mn/Mg addition on the structural, mechanical, wear, and degradation behaviors of the Zn-2Cu-xMn/Mg alloys was thoroughly investigated. Degradation and tribological behaviors of the alloys were explored in the presence of simulated body fluid (SBF), Dulbecco's modified Eagle medium (DMEM), and DMEM with a 10% fetal bovine serum (FBS) solution. Alloy elements and hot rolling improve their mechanical properties significantly due to precipitation hardening, grain refinement, and solid solution strengthening owing to the formation of MnZn13 and Mg2Zn11 phases. Among all the alloys, the Zn-2Cu-0.5Mn alloy achieved the highest ultimate tensile strength (UTS) of ∼405 MPa and yield strength (YS) of ∼293 MPa with an excellent elongation of ∼51%. The corrosion behavior of the alloys as determined by a potentiodynamic polarization study under different solutions follows the sequence Zn-2Cu < Zn-2Cu-0.5Mn < Zn-2Cu-0.1Mn < Zn-2Cu-0.1Mg < Zn-2Cu-0.5Mg. The corrosion rate by immersion testing for 30 and 90 days also follows the same sequence. The corrosion rate in different solutions follows the order SBF > DMEM + 10%FBS > DMEM. The addition of Mn/Mg also improves the wear resistance and slows the wear rate under wet conditions. The bending test results also indicate the highest bending strength of ∼375 MPa for the Zn-2Cu-0.5Mn alloy, among all the alloys. The bending and tensile strengths deteriorate continuously after the immersion for 30 and 90 days in the solution of SBF, DMEM, and DMEM + 10%FBS. Therefore, the Zn-2Cu-xMn/Mg (x = 0.1 and 0.5) alloys can be considered potential biodegradable implant materials.
Collapse
Affiliation(s)
- Debajyoti Palai
- Department of Metallurgical and Materials Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - P Siva Prasad
- Department of Metallurgical and Materials Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Bangmaya Satpathy
- Department of Metallurgical and Materials Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Siddhartha Das
- Department of Metallurgical and Materials Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Karabi Das
- Department of Metallurgical and Materials Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| |
Collapse
|
4
|
Heiss A, Thatikonda VS, Richter A, Schmitt LY, Park D, Klotz UE. Development, Processing and Aging of Novel Zn-Ag-Cu Based Biodegradable Alloys. MATERIALS (BASEL, SWITZERLAND) 2023; 16:3198. [PMID: 37110036 PMCID: PMC10141850 DOI: 10.3390/ma16083198] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/26/2023] [Revised: 04/08/2023] [Accepted: 04/14/2023] [Indexed: 06/19/2023]
Abstract
The use of biodegradable materials for implants is a promising strategy to overcome known long-term clinical complications related to permanent implants. Ideally, biodegradable implants support the damaged tissue for a certain period and then degrade, while the physiological function of the surrounding tissue is restored. Although Mg-based alloys nearly ideally lend themselves to biodegradable implants, a few critical shortcomings promoted the development of alternative alloy systems. Due to their reasonably good biocompatibility, moderate corrosion rate without hydrogen evolution and adequate mechanical properties, increasing attention has been paid to Zn alloys. In this work, precipitation-hardening alloys in the system Zn-Ag-Cu were developed relying on thermodynamic calculations. After casting the alloys, their microstructures were refined by thermomechanical treatment. The processing was tracked and directed, respectively, by routine investigations of the microstructure, associated with hardness assessments. Although microstructure refinement increased the hardness, the material proved to be susceptible to aging as the homologous temperature of zinc is at 0.43 Tm. Besides mechanical performance and corrosion rate, long-term mechanical stability is another crucial factor that must be taken into consideration to ensure the safety of the implant and thus requires a profound understanding of the aging process.
Collapse
Affiliation(s)
- Alexander Heiss
- Department of Physical Metallurgy, Research Institute for Precious Metals and Metals Chemistry (fem), Katharinenstrasse 17, 73525 Schwaebisch Gmuend, Germany
| | - Venkat Sai Thatikonda
- Department of Physical Metallurgy, Research Institute for Precious Metals and Metals Chemistry (fem), Katharinenstrasse 17, 73525 Schwaebisch Gmuend, Germany
- Department of Precision-Optics-Materials-Environment, University of Applied Sciences, 07745 Jena, Germany
| | - Andreas Richter
- Department of Physical Metallurgy, Research Institute for Precious Metals and Metals Chemistry (fem), Katharinenstrasse 17, 73525 Schwaebisch Gmuend, Germany
| | - Lisa-Yvonn Schmitt
- Department of Physical Metallurgy, Research Institute for Precious Metals and Metals Chemistry (fem), Katharinenstrasse 17, 73525 Schwaebisch Gmuend, Germany
| | - Daesung Park
- Physikalisch-Technische Bundesanstalt (PTB), 38116 Braunschweig, Germany
- Laboratory of Emerging Nanometrology (LENA), 38106 Braunschweig, Germany
| | - Ulrich E. Klotz
- Department of Physical Metallurgy, Research Institute for Precious Metals and Metals Chemistry (fem), Katharinenstrasse 17, 73525 Schwaebisch Gmuend, Germany
| |
Collapse
|
5
|
Liu Q, Li A, Liu S, Fu Q, Xu Y, Dai J, Li P, Xu S. Cytotoxicity of Biodegradable Zinc and Its Alloys: A Systematic Review. J Funct Biomater 2023; 14:206. [PMID: 37103296 PMCID: PMC10144193 DOI: 10.3390/jfb14040206] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 03/18/2023] [Accepted: 03/27/2023] [Indexed: 04/28/2023] Open
Abstract
Zinc-based biodegradable metals (BMs) have been developed for biomedical implant materials. However, the cytotoxicity of Zn and its alloys has caused controversy. This work aims to investigate whether Zn and its alloys possess cytotoxic effects and the corresponding influence factors. According to the guidelines of the PRISMA statement, an electronic combined hand search was conducted to retrieve articles published in PubMed, Web of Science, and Scopus (2013.1-2023.2) following the PICOS strategy. Eighty-six eligible articles were included. The quality of the included toxicity studies was assessed utilizing the ToxRTool. Among the included articles, extract tests were performed in 83 studies, and direct contact tests were conducted in 18 studies. According to the results of this review, the cytotoxicity of Zn-based BMs is mainly determined by three factors, namely, Zn-based materials, tested cells, and test system. Notably, Zn and its alloys did not exhibit cytotoxic effects under certain test conditions, but significant heterogeneity existed in the implementation of the cytotoxicity evaluation. Furthermore, there is currently a relatively lower quality of current cytotoxicity evaluation in Zn-based BMs owing to the adoption of nonuniform standards. Establishing a standardized in vitro toxicity assessment system for Zn-based BMs is required for future investigations.
Collapse
Affiliation(s)
- Qian Liu
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou 510280, China
| | - An Li
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou 510280, China
| | - Shizhen Liu
- The School of Computing Science, University of Glasgow, Glasgow G12 8RZ, UK
| | - Qingyun Fu
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou 510280, China
| | - Yichen Xu
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, Department of Oral Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
| | - Jingtao Dai
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou 510280, China
| | - Ping Li
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou 510280, China
| | - Shulan Xu
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou 510280, China
| |
Collapse
|
6
|
Abstract
Vascular transplantation is an effective and common treatment for cardiovascular disease (CVD). However, the low biocompatibility of implants is a major problem that hinders its clinical application. Surface modification of implants with extracellular matrix (ECM) coatings is an effective approach to improve the biocompatibility of cardiovascular materials. The complete ECM seems to have better biocompatibility, which may give cardiovascular biomaterials a more functional surface. The use of one or several ECM proteins to construct a surface allows customization of coating composition and structure, possibly resulting in some unique functions. ECM is a complex three-dimensional structure composed of a variety of functional biological macromolecules, and changes in the composition will directly affect the function of the coating. Therefore, understanding the chemical composition of the ECM and its interaction with cells is beneficial to provide new approaches for coating surface modification. This article reviews novel ECM coatings, including coatings composed of intact ECM and biomimetic coatings tailored from several ECM proteins, and introduces new advances in coating fabrication. These ECM coatings are effective in improving the biocompatibility of vascular grafts.
Collapse
|
7
|
Tong X, Zhu L, Wu Y, Song Y, Wang K, Huang S, Li Y, Ma J, Wen C, Lin J. A biodegradable Fe/Zn-3Cu composite with requisite properties for orthopedic applications. Acta Biomater 2022; 146:506-521. [PMID: 35523413 DOI: 10.1016/j.actbio.2022.04.048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Revised: 04/28/2022] [Accepted: 04/28/2022] [Indexed: 11/01/2022]
Abstract
Zinc (Zn)-based metals and alloys are emerging as promising biodegradable implant materials due to their inherent biodegradability and good biocompatibility. However, this class of materials exhibits low mechanical strength and a slow degradation rate, which hinders their clinical application. Here we report the development of a new biodegradable Fe/Zn-3Cu composite fabricated by infiltration casting of a Zn-3Cu alloy into an Fe foam followed by hot-rolling. Our results indicate that the hot-rolled (HR) Fe/Zn-3Cu composite exhibited an α-Zn matrix phase, a secondary CuZn5 phase, and an α-Fe phase. The HR Fe/Zn-3Cu composite exhibited an ultimate tensile strength of 269 MPa, a tensile yield strength of 210 MPa, and an elongation of 27%. The HR Fe/Zn-3Cu composite showed a degradation rate of 228 µm/year after immersion in Hanks' solution for 30 d The diluted extract of the HR Fe/Zn-3Cu composite exhibited a higher cell viability than that of the HR Zn-3Cu alloy in relation to MC3T3-E1 and MG-63 cells. Furthermore, the HR Fe/Zn-3Cu composite showed significantly better antibacterial ability than that of the HR Zn-3Cu alloy in relation to S. aureus. Overall, the HR Fe/Zn-3Cu composite can be anticipated to be a promising biodegradable implant material for bone-fixation applications. STATEMENT OF SIGNIFICANCE: This work reports a new biodegradable Fe/Zn-3Cu composite fabricated by infiltration casting and followed by hot-rolling for biodegradable bone-fixation application. Our findings demonstrated that the hot-rolled (HR) Fe/Zn-3Cu composite exhibited an ultimate tensile strength of 269.1 MPa, a tensile yield strength of 210.3 MPa, and an elongation of 26.7%. HR Fe/Zn-3Cu composite showed a degradation rate of 227.6 µm/a, higher than HR Zn-3Cu alloy after immersion in Hanks' solution for 30 d The diluted extracts of the HR Fe/Zn-3Cu composite exhibited a higher cell viability than HR Zn-3Cu alloy toward MC3T3-E1 cells. Furthermore, the HR Fe/Zn-3Cu composite showed significantly better antibacterial ability than the HR Zn-3Cu alloy toward S. aureus.
Collapse
|
8
|
Fabrication and characterization of biodegradable Zn-Cu-Mn alloy micro-tubes and vascular stents: microstructure, texture, mechanical properties and corrosion behavior. Acta Biomater 2022; 151:647-660. [DOI: 10.1016/j.actbio.2022.07.049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Revised: 07/21/2022] [Accepted: 07/26/2022] [Indexed: 11/20/2022]
|
9
|
Tong X, Zhu L, Wang K, Shi Z, Huang S, Li Y, Ma J, Wen C, Lin J. Impact of gadolinium on mechanical properties, corrosion resistance, and biocompatibility of Zn-1Mg-xGd alloys for biodegradable bone-implant applications. Acta Biomater 2022; 142:361-373. [PMID: 35189378 DOI: 10.1016/j.actbio.2022.02.015] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Revised: 02/10/2022] [Accepted: 02/13/2022] [Indexed: 02/03/2023]
Abstract
Zinc (Zn) and its alloys are currently regarded as one of the promising families of biodegradable metals for implant applications owing to their suitable biodegradability and biofunctionality. However, the inadequate mechanical properties of as-cast (AC) pure Zn restricted the practical clinical bone-implant applications due to its coarse grain size and hexagon close-packed crystal structure. Here, the impact of gadolinium (Gd) on the mechanical properties, corrosion resistance, hemolysis percentage, anticoagulant activity, and cytotoxicity of AC and hot-rolled (HR) Zn-1Mg-xGd (x = 0.1, 0.2, and 0.3) (wt.%) alloys were investigated for biodegradable bone-implant applications. Tensile testing showed that the HR Zn-1Mg-0.3Gd alloy exhibited the highest tensile strength of 288.1 MPa, tensile yield strength of 250.9 MPa, and elongation of 13.2%. Electrochemical corrosion and immersion tests revealed that the corrosion rates of both AC and HR specimens increased with increasing Gd content in Hanks' solution, and the HR Zn-1Mg-xGd specimens exhibited higher corrosion rates compared to their AC counterparts. The HR Zn-1Mg-xGd specimens showed an increasing hemolysis percentages and decreasing activated partial thromboplastin time (APTT) values with increasing Gd addition. The alloy extracts of HR samples at ≤ 25% concentration exhibited no cytotoxicity toward MG-63 cells, and the HR Zn-1Mg-0.3Gd alloy displayed the highest cell viability among all three alloy extracts at 12.5% concentration. Overall, the HR Zn-1Mg-0.3Gd can be considered a promising biodegradable implant material for bone-implant materials owing to its high mechanical strength and ductility, suitable degradation rate, and satisfying biocompatibility. STATEMENT OF SIGNIFICANCE: In this work, Zn-1Mg-xGd (x = 0.1, 0.2, and 0.3 wt.%) alloys were developed by alloying with gadolinium (Gd) and hot-rolling, and their mechanical properties, corrosion behavior, hemolysis percentage, anticoagulant activity, and cytotoxicity were investigated for biodegradable implant application. Our findings demonstrated that the hot-rolled Zn-1Mg-0.3Gd alloy exhibit the highest ultimate tensile strength of 288.1 MPa, yield strength of 250.9 MPa, and elongation of 13.2%. Hot-rolled Zn-1Mg-xGd alloys show slowly increasing hemolysis percentages and decreasing activated partial thromboplastin time (APTT) values with increasing Gd addition. Extracts of hot-rolled Zn-1Mg-xGd alloys at a concentration of ≤ 25% show no cytotoxicity towards MG-63 cells, and Zn-1Mg-0.3Gd exhibit good cytocompatibility among all three alloys at a concentration of 12.5%.
Collapse
|