1
|
Fuchs C, Dessain Q, Delinte N, Dausort M, Macq B. Sparse Blind Spherical Deconvolution of diffusion weighted MRI. Front Neurosci 2024; 18:1385975. [PMID: 38846718 PMCID: PMC11155299 DOI: 10.3389/fnins.2024.1385975] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2024] [Accepted: 04/19/2024] [Indexed: 06/09/2024] Open
Abstract
Diffusion-weighted magnetic resonance imaging provides invaluable insights into in-vivo neurological pathways. However, accurate and robust characterization of white matter fibers microstructure remains challenging. Widely used spherical deconvolution algorithms retrieve the fiber Orientation Distribution Function (ODF) by using an estimation of a response function, i.e., the signal arising from individual fascicles within a voxel. In this paper, an algorithm of blind spherical deconvolution is proposed, which only assumes the axial symmetry of the response function instead of its exact knowledge. This algorithm provides a method for estimating the peaks of the ODF in a voxel without any explicit response function, as well as a method for estimating signals associated with the peaks of the ODF, regardless of how those peaks were obtained. The two stages of the algorithm are tested on Monte Carlo simulations, as well as compared to state-of-the-art methods on real in-vivo data for the orientation retrieval task. Although the proposed algorithm was shown to attain lower angular errors than the state-of-the-art constrained spherical deconvolution algorithm on synthetic data, it was outperformed by state-of-the-art spherical deconvolution algorithms on in-vivo data. In conjunction with state-of-the art methods for axon bundles direction estimation, the proposed method showed its potential for the derivation of per-voxel per-direction metrics on synthetic as well as in-vivo data.
Collapse
Affiliation(s)
- Clément Fuchs
- Institute of Information and Communication Technologies, Electronics and Applied Mathematics (ICTEAM), UCLouvain, Louvain-la-Neuve, Belgium
| | - Quentin Dessain
- Institute of Information and Communication Technologies, Electronics and Applied Mathematics (ICTEAM), UCLouvain, Louvain-la-Neuve, Belgium
- Institute of NeuroScience, UCLouvain, Brussels, Belgium
| | - Nicolas Delinte
- Institute of Information and Communication Technologies, Electronics and Applied Mathematics (ICTEAM), UCLouvain, Louvain-la-Neuve, Belgium
- Institute of NeuroScience, UCLouvain, Brussels, Belgium
| | - Manon Dausort
- Institute of Information and Communication Technologies, Electronics and Applied Mathematics (ICTEAM), UCLouvain, Louvain-la-Neuve, Belgium
| | - Benoît Macq
- Institute of Information and Communication Technologies, Electronics and Applied Mathematics (ICTEAM), UCLouvain, Louvain-la-Neuve, Belgium
| |
Collapse
|
2
|
Moeller S, Pisharady Kumar P, Andersson J, Akcakaya M, Harel N, Ma RE, Wu X, Yacoub E, Lenglet C, Ugurbil K. Diffusion Imaging in the Post HCP Era. J Magn Reson Imaging 2020; 54:36-57. [PMID: 32562456 DOI: 10.1002/jmri.27247] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2020] [Revised: 05/11/2020] [Accepted: 05/13/2020] [Indexed: 02/06/2023] Open
Abstract
Diffusion imaging is a critical component in the pursuit of developing a better understanding of the human brain. Recent technical advances promise enabling the advancement in the quality of data that can be obtained. In this review the context for different approaches relative to the Human Connectome Project are compared. Significant new gains are anticipated from the use of high-performance head gradients. These gains can be particularly large when the high-performance gradients are employed together with ultrahigh magnetic fields. Transmit array designs are critical in realizing high accelerations in diffusion-weighted (d)MRI acquisitions, while maintaining large field of view (FOV) coverage, and several techniques for optimal signal-encoding are now available. Reconstruction and processing pipelines that precisely disentangle the acquired neuroanatomical information are established and provide the foundation for the application of deep learning in the advancement of dMRI for complex tissues. Level of Evidence: 3 Technical Efficacy Stage: Stage 3.
Collapse
Affiliation(s)
- Steen Moeller
- Center for Magnetic Resonance Research; Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA
| | - Pramod Pisharady Kumar
- Center for Magnetic Resonance Research; Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA
| | - Jesper Andersson
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
| | - Mehmet Akcakaya
- Center for Magnetic Resonance Research; Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA.,Electrical and Computer Engineering, University of Minnesota, Minneapolis, Minnesota, USA
| | - Noam Harel
- Center for Magnetic Resonance Research; Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA
| | - Ruoyun Emily Ma
- Center for Magnetic Resonance Research; Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA
| | - Xiaoping Wu
- Center for Magnetic Resonance Research; Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA
| | - Essa Yacoub
- Center for Magnetic Resonance Research; Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA
| | - Christophe Lenglet
- Center for Magnetic Resonance Research; Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA
| | - Kamil Ugurbil
- Center for Magnetic Resonance Research; Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA
| |
Collapse
|
3
|
Moeller S, Ramanna S, Lenglet C, Pisharady PK, Auerbach EJ, Delabarre L, Wu X, Akcakaya M, Ugurbil K. Self-navigation for 3D multishot EPI with data-reference. Magn Reson Med 2020; 84:1747-1762. [PMID: 32115756 DOI: 10.1002/mrm.28231] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2019] [Revised: 02/01/2020] [Accepted: 02/04/2020] [Indexed: 02/03/2023]
Abstract
PURPOSE In this study, we sought to develop a self-navigation strategy for improving the reconstruction of diffusion weighted 3D multishot echo planar imaging (EPI). We propose a method for extracting the phase correction information from the acquisition itself, eliminating the need for a 2D navigator, further accelerating the acquisition. METHODS In-vivo acquisitions at 3T with 0.9 mm and 1.5 mm isotropic resolutions were used to evaluate the performance of the self-navigation strategy. Sensitivity to motion was tested using a large difference in pitch position of the head. Using a multishell diffusion weighted acquisition, tractography results were obtained at (0.9 mm)3 to validate the quality with conventional acquisition. RESULTS The use of 3D multislab EPI with self-navigation enables 3D diffusion-weighted spin echo EPI acquisitions that have the same efficiency as 2D single-shot acquisition. For matched acquisition time the image signal-to-noise ratio (SNR) between 3D and 2D acquisition is shown to be comparable for whole-brain coverage with (1.5 mm)3 resolution and for (0.9 mm)3 resolution the 3D acquisition has higher SNR than what can be obtained with 2D acquisitions using current state-of-art multiband techniques. The self-navigation technique was shown to be stable under inter-volume motion. In tractography analysis, the higher resolution afforded by our technique enabled clear delineation of the tapetum and posterior corona radiata. CONCLUSION The proposed self-navigation approach utilized a self-consistent phase in 3D diffusion weighted acquisitions. Its efficiency and stability were demonstrated for a plurality of common acquisitions. The proposed self-navigation approach allows for faster acquisition of 3D multishot EPI desirable for large field of view and/or higher resolution.
Collapse
Affiliation(s)
- Steen Moeller
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, MN, USA.,Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, USA
| | - Sudhir Ramanna
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, MN, USA.,Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, USA
| | - Christophe Lenglet
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, MN, USA.,Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, USA
| | - Pramod K Pisharady
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, MN, USA.,Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, USA
| | - Edward J Auerbach
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, MN, USA.,Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, USA
| | - Lance Delabarre
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, MN, USA.,Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, USA
| | - Xiaoping Wu
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, MN, USA.,Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, USA
| | - Mehmet Akcakaya
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, MN, USA.,Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, USA
| | - Kamil Ugurbil
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, MN, USA.,Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, USA
| |
Collapse
|
4
|
De Luca A, Leemans A, Bertoldo A, Arrigoni F, Froeling M. A robust deconvolution method to disentangle multiple water pools in diffusion MRI. NMR IN BIOMEDICINE 2018; 31:e3965. [PMID: 30052293 PMCID: PMC6221109 DOI: 10.1002/nbm.3965] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2018] [Revised: 05/30/2018] [Accepted: 05/31/2018] [Indexed: 05/06/2023]
Abstract
The diffusion-weighted magnetic resonance imaging (dMRI) signal measured in vivo arises from multiple diffusion domains, including hindered and restricted water pools, free water and blood pseudo-diffusion. Not accounting for the correct number of components can bias metrics obtained from model fitting because of partial volume effects that are present in, for instance, diffusion tensor imaging (DTI) and diffusion kurtosis imaging (DKI). Approaches that aim to overcome this shortcoming generally make assumptions about the number of considered components, which are not likely to hold for all voxels. The spectral analysis of the dMRI signal has been proposed to relax assumptions on the number of components. However, it currently requires a clinically challenging signal-to-noise ratio (SNR) and accounts only for two diffusion processes defined by hard thresholds. In this work, we developed a method to automatically identify the number of components in the spectral analysis, and enforced its robustness to noise, including outlier rejection and a data-driven regularization term. Furthermore, we showed how this method can be used to take into account partial volume effects in DTI and DKI fitting. The proof of concept and performance of the method were evaluated through numerical simulations and in vivo MRI data acquired at 3 T. With simulations our method reliably decomposed three diffusion components from SNR = 30. Biases in metrics derived from DTI and DKI were considerably reduced when components beyond hindered diffusion were taken into account. With the in vivo data our method determined three macro-compartments, which were consistent with hindered diffusion, free water and pseudo-diffusion. Taking free water and pseudo-diffusion into account in DKI resulted in lower mean diffusivity and higher fractional anisotropy values in both gray and white matter. In conclusion, the proposed method allows one to determine co-existing diffusion compartments without prior assumptions on their number, and to account for undesired signal contaminations within clinically achievable SNR levels.
Collapse
Affiliation(s)
- Alberto De Luca
- PROVIDI Lab, Image Sciences InstituteUMC Utrecht and Utrecht Universitythe Netherlands
| | - Alexander Leemans
- PROVIDI Lab, Image Sciences InstituteUMC Utrecht and Utrecht Universitythe Netherlands
| | | | - Filippo Arrigoni
- Neuroimaging LabScientific Institute, IRCCS Eugenio MedeaBosisio PariniItaly
| | - Martijn Froeling
- Radiology DepartmentUMC Utrecht and Utrecht Universitythe Netherlands
| |
Collapse
|