1
|
Hagberg GE, Eckstein K, Tuzzi E, Zhou J, Robinson S, Scheffler K. Phase-based masking for quantitative susceptibility mapping of the human brain at 9.4T. Magn Reson Med 2022; 88:2267-2276. [PMID: 35754142 PMCID: PMC7613679 DOI: 10.1002/mrm.29368] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Revised: 05/05/2022] [Accepted: 05/31/2022] [Indexed: 12/15/2022]
Abstract
PURPOSE To develop improved tissue masks for QSM. METHODS Masks including voxels at the brain surface were automatically generated from the magnitude alone (MM) or combined with test functions from the first (PG) or second (PB) derivative of the sign of the wrapped phase. Phase images at 3T and 9.4T were simulated at different TEs and used to generate a mask, PItoh , with between-voxel phase differences less than π. MM, PG, and PB were compared with PItoh . QSM were generated from 3D multi-echo gradient-echo data acquired at 9.4T (21 subjects aged: 20-56y), and from the QSM2016 challenge 3T data using different masks, unwrapping, background removal, and dipole inversion algorithms. QSM contrast was quantified using age-based iron concentrations. RESULTS Close to air cavities, phase wraps became denser with increasing field and echo time, yielding increased values of the test functions. Compared with PItoh , PB had the highest Dice coefficient, while PG had the lowest and MM the highest percentage of voxels outside PItoh. Artifacts observed in QSM at 9.4T with MM were mitigated by stronger background filters but yielded a reduced QSM contrast. With PB, QSM contrast was greater and artifacts diminished. Similar results were obtained with challenge data, evidencing larger effects of mask close to air cavities. CONCLUSION Automatic, phase-based masking founded on the second derivative of the sign of the wrapped phase, including cortical voxels at the brain surface, was able to mitigate artifacts and restore QSM contrast across cortical and subcortical brain regions.
Collapse
Affiliation(s)
- Gisela E. Hagberg
- Department for Biomedical Magnetic Resonance, University Hospital Tübingen, Tübingen, Germany
- High Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Korbinian Eckstein
- High Field MR Centre, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
- High Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Elisa Tuzzi
- Department for Biomedical Magnetic Resonance, University Hospital Tübingen, Tübingen, Germany
- High Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Jiazheng Zhou
- Department for Biomedical Magnetic Resonance, University Hospital Tübingen, Tübingen, Germany
- High Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Simon Robinson
- Department of Neurology, Medical University of Graz, Graz, Austria
- High Field MR Centre, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
- Centre for Advanced Imaging, The University of Queensland, Brisbane, Australia
| | - Klaus Scheffler
- Department for Biomedical Magnetic Resonance, University Hospital Tübingen, Tübingen, Germany
- High Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| |
Collapse
|
2
|
Murdoch R, Stotesbury H, Hales PW, Kawadler JM, Kölbel M, Clark CA, Kirkham FJ, Shmueli K. A Comparison of MRI Quantitative Susceptibility Mapping and TRUST-Based Measures of Brain Venous Oxygen Saturation in Sickle Cell Anaemia. Front Physiol 2022; 13:913443. [PMID: 36105280 PMCID: PMC9465016 DOI: 10.3389/fphys.2022.913443] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Accepted: 06/15/2022] [Indexed: 11/13/2022] Open
Abstract
In recent years, interest has grown in the potential for magnetic resonance imaging (MRI) measures of venous oxygen saturation (Yv) to improve neurological risk prediction. T2-relaxation-under-spin-tagging (TRUST) is an MRI technique which has revealed changes in Yv in patients with sickle cell anemia (SCA). However, prior studies comparing Yv in patients with SCA relative to healthy controls have reported opposing results depending on whether the calibration model, developed to convert blood T2 to Yv, is based on healthy human hemoglobin (HbA), bovine hemoglobin (HbBV) or sickle hemoglobin (HbS). MRI Quantitative Susceptibility Mapping (QSM) is an alternative technique that may hold promise for estimating Yv in SCA as blood magnetic susceptibility is linearly dependent upon Yv, and no significant difference has been found between the magnetic susceptibility of HbA and HbS. Therefore, the aim of this study was to compare estimates of Yv using QSM and TRUST with five published calibration models in healthy controls and patients with SCA. 17 patients with SCA and 13 healthy controls underwent MRI. Susceptibility maps were calculated from a multi-parametric mapping acquisition and Yv was calculated from the mean susceptibility in a region of interest in the superior sagittal sinus. TRUST estimates of T2, within a similar but much smaller region, were converted to Yv using five different calibration models. Correlation and Bland-Altman analyses were performed to compare estimates of Yv between TRUST and QSM methods. For each method, t-tests were also used to explore group-wise differences between patients with SCA and healthy controls. In healthy controls, significant correlations were observed between QSM and TRUST measures of Yv, while in SCA, there were no such correlations. The magnitude and direction of group-wise differences in Yv varied with method. The TRUST-HbBV and QSM methods suggested decreased Yv in SCA relative to healthy controls, while the TRUST-HbS (p < 0.01) and TRUST-HbA models suggested increased Yv in SCA as in previous studies. Further validation of all MRI measures of Yv, relative to ground truth measures such as O15 PET and jugular vein catheterization, is required in SCA before QSM or TRUST methods can be considered for neurological risk prediction.
Collapse
Affiliation(s)
- Russell Murdoch
- Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom
| | - Hanne Stotesbury
- Developmental Neurosciences, UCL Great Ormond Street Institute of Child Health, London, United Kingdom
| | - Patrick W. Hales
- Developmental Neurosciences, UCL Great Ormond Street Institute of Child Health, London, United Kingdom
| | - Jamie M. Kawadler
- Developmental Neurosciences, UCL Great Ormond Street Institute of Child Health, London, United Kingdom
| | - Melanie Kölbel
- Developmental Neurosciences, UCL Great Ormond Street Institute of Child Health, London, United Kingdom
| | - Christopher A. Clark
- Developmental Neurosciences, UCL Great Ormond Street Institute of Child Health, London, United Kingdom
| | - Fenella J. Kirkham
- Developmental Neurosciences, UCL Great Ormond Street Institute of Child Health, London, United Kingdom
- Clinical and Experimental Sciences, University of Southampton, Southampton, United Kingdom
| | - Karin Shmueli
- Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom
| |
Collapse
|
3
|
Biondetti E, Karsa A, Grussu F, Battiston M, Yiannakas MC, Thomas DL, Shmueli K. Multi-echo quantitative susceptibility mapping: how to combine echoes for accuracy and precision at 3 Tesla. Magn Reson Med 2022; 88:2101-2116. [PMID: 35766450 PMCID: PMC9545116 DOI: 10.1002/mrm.29365] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Revised: 04/29/2022] [Accepted: 05/27/2022] [Indexed: 12/04/2022]
Abstract
Purpose To compare different multi‐echo combination methods for MRI QSM. Given the current lack of consensus, we aimed to elucidate how to optimally combine multi‐echo gradient‐recalled echo signal phase information, either before or after applying Laplacian‐base methods (LBMs) for phase unwrapping or background field removal. Methods Multi‐echo gradient‐recalled echo data were simulated in a numerical head phantom, and multi‐echo gradient‐recalled echo images were acquired at 3 Tesla in 10 healthy volunteers. To enable image‐based estimation of gradient‐recalled echo signal noise, 5 volunteers were scanned twice in the same session without repositioning. Five QSM processing pipelines were designed: 1 applied nonlinear phase fitting over TEs before LBMs; 2 applied LBMs to the TE‐dependent phase and then combined multiple TEs via either TE‐weighted or SNR‐weighted averaging; and 2 calculated TE‐dependent susceptibility maps via either multi‐step or single‐step QSM and then combined multiple TEs via magnitude‐weighted averaging. Results from different pipelines were compared using visual inspection; summary statistics of susceptibility in deep gray matter, white matter, and venous regions; phase noise maps (error propagation theory); and, in the healthy volunteers, regional fixed bias analysis (Bland–Altman) and regional differences between the means (nonparametric tests). Results Nonlinearly fitting the multi‐echo phase over TEs before applying LBMs provided the highest regional accuracy of χ and the lowest phase noise propagation compared to averaging the LBM‐processed TE‐dependent phase. This result was especially pertinent in high‐susceptibility venous regions. Conclusion For multi‐echo QSM, we recommend combining the signal phase by nonlinear fitting before applying LBMs. Click here for author‐reader discussions
Collapse
Affiliation(s)
- Emma Biondetti
- Institute for Advanced Biomedical Technologies, Department of Neuroscience, Imaging and Clinical Sciences, "D'Annunzio University" of Chieti-Pescara, Chieti, Italy.,Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom
| | - Anita Karsa
- Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom
| | - Francesco Grussu
- NMR Research Unit, Queen Square MS Centre, Department of Neuroinflammation, UCL Queen Square Institute of Neurology, University College London, London, United Kingdom.,Radiomics Group, Vall d'Hebron Institute of Oncology, Barcelona, Spain
| | - Marco Battiston
- NMR Research Unit, Queen Square MS Centre, Department of Neuroinflammation, UCL Queen Square Institute of Neurology, University College London, London, United Kingdom
| | - Marios C Yiannakas
- NMR Research Unit, Queen Square MS Centre, Department of Neuroinflammation, UCL Queen Square Institute of Neurology, University College London, London, United Kingdom
| | - David L Thomas
- Dementia Research Centre, UCL Queen Square Institute of Neurology, University College London, London, United Kingdom.,Wellcome Centre for Human Neuroimaging, UCL Queen Square Institute of Neurology, University College London, London, United Kingdom
| | - Karin Shmueli
- Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom
| |
Collapse
|
4
|
Berg RC, Preibisch C, Thomas DL, Shmueli K, Biondetti E. Investigating the effect of flow compensation and quantitative susceptibility mapping method on the accuracy of venous susceptibility measurement. Neuroimage 2021; 240:118399. [PMID: 34273528 DOI: 10.1016/j.neuroimage.2021.118399] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Revised: 06/15/2021] [Accepted: 07/13/2021] [Indexed: 11/25/2022] Open
Abstract
Quantitative susceptibility mapping (QSM) is a promising non-invasive method for obtaining information relating to oxygen metabolism. However, the optimal acquisition sequence and QSM reconstruction method for reliable venous susceptibility measurements are unknown. Full flow compensation is generally recommended to correct for the influence of venous blood flow, although the effect of flow compensation on the accuracy of venous susceptibility values has not been systematically evaluated. In this study, we investigated the effect of different acquisition sequences, including different flow compensation schemes, and different QSM reconstruction methods on venous susceptibilities. Ten healthy subjects were scanned with five or six distinct QSM sequence designs using monopolar readout gradients and different flow compensation schemes. All data sets were processed using six different QSM pipelines and venous blood susceptibility was evaluated in whole-brain segmentations of the venous vasculature and single veins. The quality of vein segmentations and the accuracy of venous susceptibility values were analyzed and compared between all combinations of sequences and reconstruction methods. The influence of the QSM reconstruction method on average venous susceptibility values was found to be 2.7-11.6 times greater than the influence of the acquisition sequence, including flow compensation. The majority of the investigated QSM reconstruction methods tended to underestimate venous susceptibility values in the vein segmentations that were obtained. In summary, we found that multi-echo gradient-echo acquisition sequences without full flow compensation yielded venous susceptibility values comparable to sequences with full flow compensation. However, the QSM reconstruction method had a great influence on susceptibility values and thus needs to be selected carefully for accurate venous QSM.
Collapse
Affiliation(s)
- Ronja C Berg
- Technical University of Munich, School of Medicine, Klinikum rechts der Isar, Department of Diagnostic and Interventional Neuroradiology, Munich, Germany.
| | - Christine Preibisch
- Technical University of Munich, School of Medicine, Klinikum rechts der Isar, Department of Diagnostic and Interventional Neuroradiology, Munich, Germany; Technical University of Munich, School of Medicine, Klinikum rechts der Isar, TUM Neuroimaging Center, Ismaninger Str. 22, 81675 Munich, Germany; Technical University of Munich, School of Medicine, Klinikum rechts der Isar, Clinic for Neurology, Ismaninger Str. 22, 81675 Munich, Munich, Germany.
| | - David L Thomas
- Department of Brain Repair and Rehabilitation, UCL Queen Square Institute of Neurology, University College London, London WC1N 3AR, United Kingdom; Dementia Research Centre, UCL Queen Square Institute of Neurology, University College London, London WC1N 3AR, United Kingdom; Wellcome Centre for Human Neuroimaging, UCL Queen Square Institute of Neurology, University College London, London WC1N 3AR, United Kingdom.
| | - Karin Shmueli
- Department of Medical Physics and Biomedical Engineering, University College London, London WC1E 6BT, United Kingdom.
| | - Emma Biondetti
- Department of Medical Physics and Biomedical Engineering, University College London, London WC1E 6BT, United Kingdom; Institut du Cerveau - ICM, Centre de NeuroImagerie de Recherche - CENIR, Team "Movement Investigations and Therapeutics" (MOV'IT), INSERM U 1127, CNRS UMR 7225, Sorbonne Université, Paris, France.
| |
Collapse
|
5
|
Rustenhoven J, Tanumihardja C, Kipnis J. Cerebrovascular Anomalies: Perspectives From Immunology and Cerebrospinal Fluid Flow. Circ Res 2021; 129:174-194. [PMID: 34166075 DOI: 10.1161/circresaha.121.318173] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Appropriate vascular function is essential for the maintenance of central nervous system homeostasis and is achieved through virtue of the blood-brain barrier; a specialized structure consisting of endothelial, mural, and astrocytic interactions. While appropriate blood-brain barrier function is typically achieved, the central nervous system vasculature is not infallible and cerebrovascular anomalies, a collective terminology for diverse vascular lesions, are present in meningeal and cerebral vasculature supplying and draining the brain. These conditions, including aneurysmal formation and rupture, arteriovenous malformations, dural arteriovenous fistulas, and cerebral cavernous malformations, and their associated neurological sequelae, are typically managed with neurosurgical or pharmacological approaches. However, increasing evidence implicates interacting roles for inflammatory responses and disrupted central nervous system fluid flow with respect to vascular perturbations. Here, we discuss cerebrovascular anomalies from an immunologic angle and fluid flow perspective. We describe immune contributions, both common and distinct, to the formation and progression of diverse cerebrovascular anomalies. Next, we summarize how cerebrovascular anomalies precipitate diverse neurological sequelae, including seizures, hydrocephalus, and cognitive effects and possible contributions through the recently identified lymphatic and glymphatic systems. Finally, we speculate on and provide testable hypotheses for novel nonsurgical therapeutic approaches for alleviating neurological impairments arising from cerebrovascular anomalies, with a particular emphasis on the normalization of fluid flow and alleviation of inflammation through manipulations of the lymphatic and glymphatic central nervous system clearance pathways.
Collapse
Affiliation(s)
- Justin Rustenhoven
- Center for Brain Immunology and Glia (J.R., J.K.), Washington University in St. Louis, St Louis, MO.,Department of Pathology and Immunology, School of Medicine (J.R., J.K.), Washington University in St. Louis, St Louis, MO
| | | | - Jonathan Kipnis
- Center for Brain Immunology and Glia (J.R., J.K.), Washington University in St. Louis, St Louis, MO.,Department of Pathology and Immunology, School of Medicine (J.R., J.K.), Washington University in St. Louis, St Louis, MO
| |
Collapse
|
6
|
Sun T, Qu F, Yadav B, Subramanian K, Jiang L, Haacke EM, Qian Z. Estimating cerebral venous oxygenation in human fetuses with ventriculomegaly using quantitative susceptibility mapping. Magn Reson Imaging 2021; 80:21-25. [PMID: 33845161 DOI: 10.1016/j.mri.2021.04.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Revised: 03/02/2021] [Accepted: 04/05/2021] [Indexed: 11/15/2022]
Abstract
RATIONALE AND OBJECTIVES The goal of this study was to estimate venous blood oxygen saturation (SvO2) in the superior sagittal sinus (SSS) in fetal brains with ventriculomegaly (VM) using quantitative susceptibility mapping (QSM). MATERIALS AND METHODS A radiofrequency spoiled gradient echo sequence was used to evaluate data on 19 fetuses with VM (gestational age(GA): median = 29.9 weeks (range 23 to 37.3 weeks)) and 20 healthy fetuses (GA: median = 30.9 (range 22.7 to 38.7 weeks)) at 1.5 T. Susceptibility weighted images encompassing the entire fetal brain were acquired within 1 min. An iterative, geometry constraint-based thresholded k-space division algorithm was used for generating QSM data of the fetal brain. The venous oxygen saturation was calculated using the magnetic susceptibility of the SSS obtained from the QSM data. Mixed-model analysis of variance and interobserver variability assessment were used to analyze the results. RESULTS The median SvO2 values in the entire VM cohort as well as for second and third trimester fetuses (with interquartile range) were: 67.8% (63.2%, 73.6%), 73.1% (69.1%, 77.3%) and 63.8% (59.4%, 68.1%), respectively. The corresponding median SvO2 value in the healthy control group was: 65.3% (58.3%, 68.2%), 67.5% (61.7%, 69.2%) and 60.8% (53.6%, 68.2%), respectively. However, the difference of SvO2 between VM and control groups was not significant at the p = 0.05 level (p = 0.076). The SvO2 was found decreasing significantly with GA in the healthy control group (p < 0.05). CONCLUSIONS We report for the first time the estimation of cerebral SvO2 in human fetuses with VM using QSM. This measure of oxygen saturation might be beneficial in assessing and monitoring the metabolic status of the fetus in various clinical conditions.
Collapse
Affiliation(s)
- Taotao Sun
- Department of Radiology, International Peace Maternity and Child Health Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China; Shanghai Key Laboratory of Embryo Original Diseases, Shanghai, China; Department of Radiology, Shandong Medical Imaging Research Institute, Shandong University, Jinan, Shandong, China
| | - Feifei Qu
- Department of Radiology, Wayne State University School of Medicine, Detroit, MI, USA
| | - Brijesh Yadav
- Department of Radiology, Wayne State University School of Medicine, Detroit, MI, USA; Department of Biomedical Engineering, College of Engineering, Wayne State University, Detroit, MI, USA
| | | | - Ling Jiang
- Department of Radiology, International Peace Maternity and Child Health Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China; Shanghai Key Laboratory of Embryo Original Diseases, Shanghai, China
| | - E Mark Haacke
- Department of Radiology, Wayne State University School of Medicine, Detroit, MI, USA; Department of Biomedical Engineering, College of Engineering, Wayne State University, Detroit, MI, USA; The MRI Institute for Biomedical Research, Bingham Farms, MI, USA.
| | - Zhaoxia Qian
- Department of Radiology, International Peace Maternity and Child Health Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China; Shanghai Key Laboratory of Embryo Original Diseases, Shanghai, China.
| |
Collapse
|
7
|
Karsa A, Punwani S, Shmueli K. An optimized and highly repeatable MRI acquisition and processing pipeline for quantitative susceptibility mapping in the head-and-neck region. Magn Reson Med 2020; 84:3206-3222. [PMID: 32621302 DOI: 10.1002/mrm.28377] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2019] [Revised: 05/06/2020] [Accepted: 05/23/2020] [Indexed: 02/11/2024]
Abstract
PURPOSE Quantitative Susceptibility Mapping (QSM) is an emerging technique sensitive to disease-related changes including oxygenation. It is extensively used in brain studies and has increasing clinical applications outside the brain. Here we present the first MRI acquisition protocol and QSM pipeline optimized for the head-and-neck region together with a repeatability analysis performed in healthy volunteers. METHODS We investigated both the intrasession and the intersession repeatability of the optimized method in 10 subjects. We also implemented two, Tikhonov-regularisation-based susceptibility calculation techniques that were found to have higher contrast-to-noise than existing methods in the head-and-neck region. Repeatability was evaluated by calculating the distributions of susceptibility differences between repeated scans and the corresponding minimum detectable effect sizes (MDEs). RESULTS Deep brain regions had higher QSM repeatability than neck regions. As expected, intrasession repeatability was generally better than intersession repeatability. Susceptibility maps calculated using projection onto dipole fields for background field removal were more repeatable than using the Laplacian boundary value method in the head-and-neck region. Small (short-axis diameter <5 mm) lymph nodes had the lowest repeatability (MDE = 0.27 ppm) as imperfect segmentation included some of the surrounding paramagnetic fatty fascia, highlighting the importance of accurate region delineation. MDEs in the larger lymph nodes (0.16 ppm), submandibular glands (0.10 ppm), and especially the parotid glands (0.06 ppm) were much lower, comparable to those of the brain regions. CONCLUSIONS The high repeatability of the acquisition and pipeline optimized for QSM will facilitate clinical studies in the head-and-neck region.
Collapse
Affiliation(s)
- Anita Karsa
- Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom
- Centre for Medical Imaging, University College London, London, United Kingdom
| | - Shonit Punwani
- Centre for Medical Imaging, University College London, London, United Kingdom
| | - Karin Shmueli
- Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom
- Centre for Medical Imaging, University College London, London, United Kingdom
| |
Collapse
|
8
|
Yanagihara TK, Wang TJC. Commentary: Stagnant Venous Outflow Predicts Brain Arteriovenous Malformation Obliteration After Gamma Knife Radiosurgery Without Prior Intervention. Neurosurgery 2020; 87:E119-E120. [PMID: 31792535 DOI: 10.1093/neuros/nyz518] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2019] [Accepted: 10/01/2019] [Indexed: 11/13/2022] Open
Affiliation(s)
- Ted K Yanagihara
- Department of Radiation Oncology, University of North Carolina, Chapel Hill, North Carolina
| | - Tony J C Wang
- Department of Radiation Oncology, Columbia University Irving Medical Center, New York, New York
| |
Collapse
|
9
|
|
10
|
Biondetti E, Karsa A, Thomas DL, Shmueli K. Investigating the accuracy and precision of TE-dependent versus multi-echo QSM using Laplacian-based methods at 3 T. Magn Reson Med 2020; 84:3040-3053. [PMID: 32491224 DOI: 10.1002/mrm.28331] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2019] [Revised: 03/19/2020] [Accepted: 04/29/2020] [Indexed: 12/14/2022]
Abstract
PURPOSE Multi-echo gradient-recalled echo acquisitions for QSM enable optimizing the SNR for several tissue types through multi-echo (TE) combination or investigating temporal variations in the susceptibility (potentially reflecting tissue microstructure) by calculating one QSM image at each TE (TE-dependent QSM). In contrast with multi-echo QSM, applying Laplacian-based methods (LBMs) for phase unwrapping and background field removal to single TEs could introduce nonlinear temporal variations (independent of tissue microstructure) into the measured susceptibility. Here, we aimed to compare the effect of LBMs on the QSM susceptibilities in TE-dependent versus multi-echo QSM. METHODS TE-dependent recalled echo data simulated in a numerical head phantom and gradient-recalled echo images acquired at 3 T in 10 healthy volunteers. Several QSM pipelines were tested, including four distinct LBMs: sophisticated harmonic artifact reduction for phase data (SHARP), variable-radius sophisticated harmonic artifact reduction for phase data (V-SHARP), Laplacian boundary value background field removal (LBV), and one-step total generalized variation (TGV). Results from distinct pipelines were compared using visual inspection, summary statistics of susceptibility in deep gray matter/white matter/venous regions of interest, and, in the healthy volunteers, regional susceptibility bias analysis and nonparametric tests. RESULTS Multi-echo versus TE-dependent QSM had higher regional accuracy, especially in high-susceptibility regions and at shorter TEs. Everywhere except in the veins, a processing pipeline incorporating TGV provided the most temporally stable TE-dependent QSM results with an accuracy similar to multi-echo QSM. CONCLUSIONS For TE-dependent QSM, carefully choosing LBMs can minimize the introduction of LBM-related nonlinear temporal susceptibility variations.
Collapse
Affiliation(s)
- Emma Biondetti
- Centre de NeuroImagerie de Recherche (CENIR), Team "Movement Investigations and Therapeutics", Institut du Cerveau (ICM), Inserm U 1127, CNRS UMR 7225, Sorbonne Université, Paris, France.,Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom
| | - Anita Karsa
- Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom
| | - David L Thomas
- Dementia Research Centre, UCL Queen Square Institute of Neurology, University College London, London, United Kingdom.,Wellcome Centre for Human Neuroimaging, UCL Queen Square Institute of Neurology, University College London, London, United Kingdom
| | - Karin Shmueli
- Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom
| |
Collapse
|
11
|
Tao Q, Zhang L, Han X, Chen H, Ji X, Zhang X. Magnetic Susceptibility Difference-Induced Nucleus Positioning in Gradient Ultrahigh Magnetic Field. Biophys J 2019; 118:578-585. [PMID: 31952800 PMCID: PMC7004839 DOI: 10.1016/j.bpj.2019.12.020] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2019] [Revised: 12/07/2019] [Accepted: 12/18/2019] [Indexed: 01/18/2023] Open
Abstract
Despite the importance of magnetic properties of biological samples for biomagnetism and related fields, the exact magnetic susceptibilities of most biological samples in their physiological conditions are still unknown. Here we used superconducting quantum interferometer device to detect the magnetic properties of nonfixed, nondehydrated live cell and cellular fractions at a physiological temperature of 37°C (310 K). It is obvious that there are paramagnetic components within human nasopharyngeal carcinoma CNE-2Z cells. More importantly, the magnetic properties of the cytoplasm and nucleus are different. Although within a single cell, the magnetic susceptibility difference between cellular fractions (nucleus and cytoplasm) could only cause ∼41-130 pN forces to the nucleus by gradient ultrahigh magnetic fields of 13.1-23.5 T (92-160 T/m), these forces are enough to cause a relative position shift of the nucleus within the cell. This not only demonstrates the importance of magnetic susceptibility in the biological effects of magnetic field but also illustrates the potential application of high magnetic fields in biomedicine.
Collapse
Affiliation(s)
- Qingping Tao
- High Magnetic Field Laboratory, Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China; Science Island Branch of Graduate School, University of Science and Technology of China, Hefei, China
| | - Lei Zhang
- High Magnetic Field Laboratory, Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China.
| | - Xuyao Han
- School of Pharmacy, Anhui Medical University, Hefei, Anhui Province, China
| | - Hanxiao Chen
- High Magnetic Field Laboratory, Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China; Science Island Branch of Graduate School, University of Science and Technology of China, Hefei, China
| | - Xinmiao Ji
- High Magnetic Field Laboratory, Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China
| | - Xin Zhang
- High Magnetic Field Laboratory, Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China; Science Island Branch of Graduate School, University of Science and Technology of China, Hefei, China; Institutes of Physical Science and Information Technology, Anhui University, Hefei, China.
| |
Collapse
|