1
|
Laakso I, Tani K, Gomez-Tames J, Hirata A, Tanaka S. Small effects of electric field on motor cortical excitability following anodal tDCS. iScience 2024; 27:108967. [PMID: 38352229 PMCID: PMC10863330 DOI: 10.1016/j.isci.2024.108967] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Revised: 12/05/2023] [Accepted: 01/16/2024] [Indexed: 02/16/2024] Open
Abstract
The dose-response characteristics of transcranial direct current stimulation (tDCS) remain uncertain but may be related to variability in brain electric fields due to individual anatomical factors. Here, we investigated whether the electric fields influence the responses to motor cortical tDCS. In a randomized cross-over design, 21 participants underwent 10 min of anodal tDCS with 0.5, 1.0, 1.5, or 2.0 mA or sham. Compared to sham, all active conditions increased the size of motor evoked potentials (MEP) normalized to the pre-tDCS baseline, irrespective of anterior or posterior magnetic test stimuli. The electric field calculated in the motor cortex of each participant had a nonlinear effect on the normalized MEP size, but its effects were small compared to those of other participant-specific factors. The findings support the efficacy of anodal tDCS in enhancing the MEP size but do not demonstrate any benefits of personalized electric field modeling in explaining tDCS response variability.
Collapse
Affiliation(s)
- Ilkka Laakso
- Department of Electrical Engineering and Automation, Aalto University, 02150 Espoo, Finland
| | - Keisuke Tani
- Faculty of Psychology, Otemon Gakuin University, Ibaraki, Osaka 567-8502, Japan
| | - Jose Gomez-Tames
- Department of Medical Engineering, Graduate School of Engineering, Chiba University, Chiba 263-8522, Japan
| | - Akimasa Hirata
- Department of Electrical and Mechanical Engineering, Nagoya Institute of Technology, Nagoya 466-8555, Japan
- Center of Biomedical Physics and Information Technology, Nagoya Institute of Technology, Nagoya 466-8555, Japan
| | - Satoshi Tanaka
- Laboratory of Psychology, Hamamatsu University School of Medicine, Hamamatsu, Shizuoka 431-3125, Japan
| |
Collapse
|
2
|
Yu H, Chen S, Ye Z, Zhang Q, Tu Y, Hua T. Top-down influence of areas 21a and 7 differently affects the surround suppression of V1 neurons in cats. Cereb Cortex 2023; 33:11047-11059. [PMID: 37724432 DOI: 10.1093/cercor/bhad344] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Revised: 08/28/2023] [Accepted: 08/29/2023] [Indexed: 09/20/2023] Open
Abstract
Surround suppression (SS) is a phenomenon whereby a neuron's response to stimuli in its central receptive field (cRF) is suppressed by stimuli extending to its surround receptive field (sRF). Recent evidence show that top-down influence contributed to SS in the primary visual cortex (V1). However, how the top-down influence from different high-level cortical areas affects SS in V1 has not been comparatively observed. The present study applied transcranial direct current stimulation (tDCS) to modulate the neural activity in area 21a (A21a) and area 7 (A7) of cats and examined the changes in the cRF and sRF of V1 neurons. We found that anode-tDCS at A21a reduced V1 neurons' cRF size and increased their response to visual stimuli in cRF, causing an improved SS strength. By contrast, anode-tDCS at A7 increased V1 neurons' sRF size and response to stimuli in cRF, also enhancing the SS. Modeling analysis based on DoG function indicated that the increased SS of V1 neurons after anode-tDCS at A21a could be explained by a center-only mechanism, whereas the improved SS after anode-tDCS at A7 might be mediated through a combined center and surround mechanism. In conclusion, A21a and A7 may affect the SS of V1 neurons through different mechanisms.
Collapse
Affiliation(s)
- Hao Yu
- College of Life Sciences, Anhui Normal University, Beijing East Road, Jinghu District, Wuhu, Anhui 241000, China
- School of Basic Medical Sciences, Wannan Medical College, West Wenchang Road, Yijiang District, Wuhu, Anhui, China
| | - Shunshun Chen
- College of Life Sciences, Anhui Normal University, Beijing East Road, Jinghu District, Wuhu, Anhui 241000, China
| | - Zheng Ye
- College of Life Sciences, Anhui Normal University, Beijing East Road, Jinghu District, Wuhu, Anhui 241000, China
| | - Qiuyu Zhang
- College of Life Sciences, Anhui Normal University, Beijing East Road, Jinghu District, Wuhu, Anhui 241000, China
| | - Yanni Tu
- College of Life Sciences, Anhui Normal University, Beijing East Road, Jinghu District, Wuhu, Anhui 241000, China
| | - Tianmiao Hua
- College of Life Sciences, Anhui Normal University, Beijing East Road, Jinghu District, Wuhu, Anhui 241000, China
| |
Collapse
|
3
|
Lavezzi GD, Galan SS, Andersen H, Tomer D, Cacciamani L. The Effects of tDCS on Object Perception: A Systematic Review and Meta-Analysis. Behav Brain Res 2022; 430:113927. [DOI: 10.1016/j.bbr.2022.113927] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Revised: 04/21/2022] [Accepted: 05/11/2022] [Indexed: 11/02/2022]
|
4
|
Skocypec RM, Peterson MA. Semantic Expectation Effects on Object Detection: Using Figure Assignment to Elucidate Mechanisms. Vision (Basel) 2022; 6:vision6010019. [PMID: 35324604 PMCID: PMC8953613 DOI: 10.3390/vision6010019] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Revised: 03/02/2022] [Accepted: 03/15/2022] [Indexed: 11/16/2022] Open
Abstract
Recent evidence suggesting that object detection is improved following valid rather than invalid labels implies that semantics influence object detection. It is not clear, however, whether the results index object detection or feature detection. Further, because control conditions were absent and labels and objects were repeated multiple times, the mechanisms are unknown. We assessed object detection via figure assignment, whereby objects are segmented from backgrounds. Masked bipartite displays depicting a portion of a mono-oriented object (a familiar configuration) on one side of a central border were shown once only for 90 or 100 ms. Familiar configuration is a figural prior. Accurate detection was indexed by reports of an object on the familiar configuration side of the border. Compared to control experiments without labels, valid labels improved accuracy and reduced response times (RTs) more for upright than inverted objects (Studies 1 and 2). Invalid labels denoting different superordinate-level objects (DSC; Study 1) or same superordinate-level objects (SSC; Study 2) reduced accuracy for upright displays only. Orientation dependency indicates that effects are mediated by activated object representations rather than features which are invariant over orientation. Following invalid SSC labels (Study 2), accurate detection RTs were longer than control for both orientations, implicating conflict between semantic representations that had to be resolved before object detection. These results demonstrate that object detection is not just affected by semantics, it entails semantics.
Collapse
Affiliation(s)
- Rachel M. Skocypec
- Visual Perception Lab, Department of Psychology, School of Mind, Brain and Behavior, University of Arizona, Tucson, AZ 85721, USA
- Cognitive Science Program, School of Mind, Brain and Behavior, University of Arizona, Tucson, AZ 85721, USA
- Correspondence: (R.M.S.); (M.A.P.)
| | - Mary A. Peterson
- Visual Perception Lab, Department of Psychology, School of Mind, Brain and Behavior, University of Arizona, Tucson, AZ 85721, USA
- Cognitive Science Program, School of Mind, Brain and Behavior, University of Arizona, Tucson, AZ 85721, USA
- Correspondence: (R.M.S.); (M.A.P.)
| |
Collapse
|
5
|
Gardi AZ, Vogel AK, Dharia AK, Krishnan C. Effect of conventional transcranial direct current stimulation devices and electrode sizes on motor cortical excitability of the quadriceps muscle. Restor Neurol Neurosci 2021; 39:379-391. [PMID: 34657855 DOI: 10.3233/rnn-211210] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND There is a growing concern among the scientific community that the effects of transcranial direct current stimulation (tDCS) are highly variable across studies. The use of different tDCS devices and electrode sizes may contribute to this variability; however, this issue has not been verified experimentally. OBJECTIVE To evaluate the effects of tDCS device and electrode size on quadriceps motor cortical excitability. METHODS The effect of tDCS device and electrode size on quadriceps motor cortical excitability was quantified across a range of TMS intensities using a novel evoked torque approach that has been previously shown to be highly reliable. In experiment 1, anodal tDCS-induced excitability changes were measured in twenty individuals using two devices (Empi and Soterix) on two separate days. In experiment 2, anodal tDCS-induced excitability changes were measured in thirty individuals divided into three groups based on the electrode size. A novel Bayesian approach was used in addition to the classical hypothesis testing during data analyses. RESULTS There were no significant main or interaction effects, indicating that cortical excitability did not differ between different tDCS devices or electrode sizes. The lack of pre-post time effect in both experiments indicated that cortical excitability was minimally affected by anodal tDCS. Bayesian analyses indicated that the null model was more favored than the main or the interaction effects model. CONCLUSIONS Motor cortical excitability was not altered by anodal tDCS and did not differ by devices or electrode sizes used in the study. Future studies should examine if behavioral outcomes are different based on tDCS device or electrode size.
Collapse
Affiliation(s)
- Adam Z Gardi
- NeuRRo Lab, Department of Physical Medicine and Rehabilitation, Michigan Medicine, Ann Arbor, MI, USA
| | - Amanda K Vogel
- NeuRRo Lab, Department of Physical Medicine and Rehabilitation, Michigan Medicine, Ann Arbor, MI, USA
| | - Aastha K Dharia
- NeuRRo Lab, Department of Physical Medicine and Rehabilitation, Michigan Medicine, Ann Arbor, MI, USA
| | - Chandramouli Krishnan
- NeuRRo Lab, Department of Physical Medicine and Rehabilitation, Michigan Medicine, Ann Arbor, MI, USA.,Michigan Robotics Institute, University of Michigan, Ann Arbor, MI, USA.,School of Kinesiology, University of Michigan, Ann Arbor, MI, USA.,Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
| |
Collapse
|
6
|
A Novel Highly Durable Carbon/Silver/Silver Chloride Composite Electrode for High-Definition Transcranial Direct Current Stimulation. NANOMATERIALS 2021; 11:nano11081962. [PMID: 34443793 PMCID: PMC8400871 DOI: 10.3390/nano11081962] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Revised: 07/21/2021] [Accepted: 07/27/2021] [Indexed: 11/29/2022]
Abstract
High-definition transcranial direct current stimulation (HD-tDCS) is a promising non-invasive neuromodulation technique, which has been widely used in the clinical intervention and treatment of neurological or psychiatric disorders. Sintered Ag/AgCl electrode has become a preferred candidate for HD-tDCS, but its service life is very short, especially for long-term anodal stimulation. To address this issue, a novel highly durable conductive carbon/silver/silver chloride composite (C/Ag/AgCl) electrode was fabricated by a facile cold rolling method. The important parameters were systematically optimized, including the conductive enhancer, the particle size of Ag powder, the C:Ag:PTFE ratio, the saline concentration, and the active substance loading. The CNT/Ag/AgCl-721 electrode demonstrated excellent specific capacity and cycling performance. Both constant current anodal polarization and simulated tDCS measurement demonstrated that the service life of the CNT/Ag/AgCl-721 electrodes was 15-16 times of that of sintered Ag/AgCl electrodes. The much longer service life can be attributed to the formation of the three-dimensional interpenetrating conductive network with CNT doping, which can maintain a good conductivity and cycling performance even if excessive non-conductive AgCl is accumulated on the surface during long-term anodal stimulation. Considering their low cost, long service life, and good skin tolerance, the proposed CNT/Ag/AgCl electrodes have shown promising application prospects in HD-tDCS, especially for daily life scenarios.
Collapse
|