1
|
Effects of inclination and flow velocity on steam condensation consisting of air on tube bundle external surfaces. PROGRESS IN NUCLEAR ENERGY 2021. [DOI: 10.1016/j.pnucene.2021.103722] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
2
|
Numerical investigations on steam condensation in the presence of air on external surfaces of 3 × 3 tube bundles. PROGRESS IN NUCLEAR ENERGY 2019. [DOI: 10.1016/j.pnucene.2018.10.021] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
3
|
Fernández-Cosials K, Jiménez G, Serrano C, Ibáñez L, Peinado Á. Analysis of Inertization Strategies for the Filtered Containment Venting System in Cofrentes Nuclear Power Plant. JOURNAL OF NUCLEAR ENGINEERING AND RADIATION SCIENCE 2018. [DOI: 10.1115/1.4038595] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
During a severe accident (SA) in a nuclear power plant (NPP), there are several challenges that need to be faced. To coup with a containment overpressure, the venting action will lower the pressure but it will release radioactivity to the environment. In order to reduce the radioactivity released, a filtered containment venting system (FCVS) can be used to retain iodine and aerosols radioactive releases coming from the containment atmosphere. However, during a SA, large quantities of hydrogen can also be generated. Hydrogen reacts violently with oxygen and its combustion could impair systems, components, or structures. For this reason, to protect the integrity of the FCVS against hydrogen explosions, an inertization system is found necessary. This system should create an inert atmosphere previous to any containment venting that impedes the contact of hydrogen and oxygen. In this paper, the inertization system for Cofrentes NPP is presented. It consists of a nitrogen injection located in three different points. A computational model of the FCVS as well as the inertization system has been created. The results show that if the nitrogen sweeps and the containment venting are properly synchronized, the hydrogen risk could be reduced to a minimum and therefore, the integrity of the FCVS would be preserved.
Collapse
Affiliation(s)
- Kevin Fernández-Cosials
- Energy Engineering Department, Universidad Politécnica de Madrid, Madrid 28006, Spain e-mail:
| | - Gonzalo Jiménez
- Energy Engineering Department, Universidad Politécnica de Madrid, Madrid 28006, Spain e-mail:
| | | | | | | |
Collapse
|
4
|
Prabhakar A, Agrawal N, Raghavan V, Das SK. An experimental study on the effect of coaxial circular disk obstacle on helium jet distribution inside the unventilated enclosure of AIHMS facility. ANN NUCL ENERGY 2018. [DOI: 10.1016/j.anucene.2018.02.047] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
5
|
Zhang H, Li Y, Xiao J, Jordan T. Large eddy simulation of turbulent flow using the parallel computational fluid dynamics code GASFLOW-MPI. NUCLEAR ENGINEERING AND TECHNOLOGY 2017. [DOI: 10.1016/j.net.2017.08.003] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
6
|
Liu Q, Morooka S. Recent activities in the field of thermal hydraulic researches. J NUCL SCI TECHNOL 2014. [DOI: 10.1080/00223131.2014.924887] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|