1
|
Martinez-Quiroga V, Freixa J, Reventos F. Kv-scaling in thermal hydraulics: Background, applications and forthcoming uses. NUCLEAR ENGINEERING AND DESIGN 2023. [DOI: 10.1016/j.nucengdes.2022.112141] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
|
2
|
RELAP5 Foresight Thermal-Hydraulic Analysis of Hypothesis Passive Safety Injection System under LOCA for an Existing NPP in China. SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS 2020. [DOI: 10.1155/2020/8844910] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Qinshan nuclear power plant is the first large Chinese-designed nuclear power station based on pressurized water reactor, and the second generation main stream active safety injection system is adopted for Qinshan nuclear power plant. In this paper, a novel passive safety injection system (PSIS) has been proposed for ocean-based Qinshan Phase One nuclear power plant to replace the original active one. The PSIS contains high-pressure, medium-pressure, and lower-pressure safety injection systems, and a two-stage automatic depressurization system. To evaluate the system performance, small-break LOCA has been investigated using RELAP5. Various break sizes and locations including 2-inch, 10-inch cold leg break, and double-ended direct vessel injection line break were analyzed. Key safety parameters such as safe injection mass flow rates, coolant level of the core, system pressure, and fuel cladding temperature were monitored during the accident process. The results illustrate that the performance of the safety injection system can guarantee the effective core cooling and submerged under different LOCA even with only half of the safety injection system, which can fulfill the single failure criteria. The thermal-hydraulic analysis for the Qinshan passive safety injection system is significant to master the related technologies for Chinese engineer and develop the Chinese-designed third-generation nuclear power plants, and the PSIS can guarantee the reactor submerged under LOCA even plus the station block out accident.
Collapse
|
3
|
Querol A, Gallardo S, Verdú G. Analysis of the Core Exit Temperature and the Peak Cladding Temperature During a SBLOCA: Application to a Scaled-Up Model. JOURNAL OF NUCLEAR ENGINEERING AND RADIATION SCIENCE 2016. [DOI: 10.1115/1.4031016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
During loss-of-coolant accidents (LOCAs), operators may start accident management (AM) actions when the core exit temperature (CET) measured by thermocouples exceeds a certain value. However, a significant time delay and temperature discrepancy in the superheat detection were observed in several facilities. This work is focused on clarifying CET thermocouple responses versus peak cladding temperature (PCT) and studying if the same physical phenomena are reproduced in two TRACE5 models with different geometry (a large-scale test facility (LSTF) and a scaled-up LSTF) during a pressure vessel (PV) upper head small break LOCA (SBLOCA). Results obtained show that the delay between the core uncover and the CET excursion is reproduced in both cases.
Collapse
Affiliation(s)
- Andrea Querol
- Instituto de Seguridad Industrial, Radiofísica y Medioambiental (ISIRYM), Universitat Politècnica de València, Camino de Vera s/n, Valencia 46022, Spain e-mail:
| | - Sergio Gallardo
- Instituto de Seguridad Industrial, Radiofísica y Medioambiental (ISIRYM), Universitat Politècnica de València, Camino de Vera s/n, Valencia 46022, Spain e-mail:
| | - Gumersindo Verdú
- Instituto de Seguridad Industrial, Radiofísica y Medioambiental (ISIRYM), Universitat Politècnica de València, Camino de Vera s/n, Valencia 46022, Spain e-mail:
| |
Collapse
|